VAN DAMME Brown Series Ecoflex Starquad LSZH Cable Owner’s Manual

July 8, 2024
VAN DAMME

VAN DAMME Brown Series Ecoflex Starquad LSZH Cable Owner’s Manual
VAN DAMME Brown Series Ecoflex Starquad LSZH Cable Owner's
Manual

Van Damme Brown Series Ecoflex is a foil screened Low Smoke Zero Halogen (LSZH) single quad and starquad multicore primarily for the installation market. As this cable is specified for installation a foil screen as opposed to braided copper is used as the cable should not have to cope with dynamic flexing.

KEY BENEFITS

  • **Low Smake Zero Halogen

**

  • **Noise Rejection

**

MATERIALS

  • **Oxygen Free Copper

**

  • **SHF1 LSZH Polymer

**

APPLICATIONS

  • Broadcast Installations

  • Live Sound Installations

  • Staduims
    Symbols

Applications

  • Microphone level signals in installation environments; particularly where high levels of RFI and EMI may be found
  • Also suitable for mixed mic/line level applications
  • Installation in public buildings, schools and colleges, government premises and marine vessels
  • Equipment rack wiring where LSZH materials have been specified and/or where starquad conductors would be advantageous

Application Notes

  • Fully tested and compliant with the following IEC standards: IEC 60332.1 Fire retardancy of a single cable; IEC 60754.1 Amount of Halogen Gas Emissions; IEC 60754.2 Degree of acidity of released gases; IEC 61034.2 Measurement of smoke density
  • Precise cable geometry and starquad construction for excellent rejection of radio frequency and electromagnetic interference (RFI and EMI)
  • BBC standard colour coding – blue & red (+ve phase) with green & white (-ve phase) opposing; pairs should be terminated as above
  • Ultra-pure oxygen free copper for outstanding sonic integrity

Mechanical Specification

Multicores

Conductor 7 x 0.12 mm bare ultra-pure oxygen-free copper
Conductor size 7 x 0.12 mm, 0.08 mm2 , AWG 28/7
Insulation Low density polyolefin
Insulation diameter 0.90 ± 0.10 mm
Colour Code Blue & Red +ve, Green & White –ve
Drain wire 7 x 0.14 mm tinned ultra-pure oxygen-free copper
Drain wire size 7 x 0.14 mm, 0.10 mm2 , AWG 27/7
Screen 24 µm Aluminium/Polyester Foil > 100% coverage
Jacket material SHF-1 LSZH thermoplastic polymer
Overall diameter 3.70 ± 0.12 mm
Cooler Ruby Red, RAL 3004

Overall Construction

Separator Soft textile tape > 125% coverage
Jacket material SHF-1 LSZH thermoplastic polymer
Colour Red Brown, RAL 8012
Bend radius 15 x overall diameter
Operating temperature -35 to +70 ⁰C

1 Pair

Conductor 7 x 0.12 mm bare ultra-pure oxygen-free copper
Conductor size 7 x 0.12 mm, 0.08 mm2 , AWG 28/7
Insulation Low density polyolefin
Insulation diameter 0.90 ± 0.10 mm
Colour Code Blue & Red +ve, Green & White –ve
Drain wire 7 x 0.14 mm tinned ultra-pure oxygen-free copper
Drain wire size 7 x 0.14 mm, 0.10 mm2 , AWG 27/7
Screen 24 µm Aluminium/Polyester Foil > 100% coverage
Jacket material SHF-1 LSZH thermoplastic polymer
Overall diameter 3.70 ± 0.12 mm
Colour Ruby Red, RAL 3004
Bend radius 15 x overall diameter
Operating temperature 35 to +70 ⁰C

Electrical Specification

Part Number Description OverallDiameter Max. ReelLength
278-801-000 Van Damme Brown Series Ecoflex LSZH single quad 3.70 mm 500 m
278-804-000 Van Damme Brown Series Ecoflex LSZH 4 way quad multicore 11.10
mm 500 m
278-808-000 Van Damme Brown Series Ecoflex LSZH 8 way quad multicore 20.00
mm 500 m

Part Numbers and Description

Part Number| Description| Overall
Diameter| Max. Reel Length
---|---|---|---
278-801-000| Van Damme Brown Series Ecoflex LSZH single quad| 3.70 mm| 500 m
278-804-000| Van Damme Brown Series Ecoflex LSZH 4 way quad multicore 11.10 mm| 11.10 mm| 500 m
278-808-000| Van Damme Brown Series Ecoflex LSZH 8 way quad multicore 20.00 mm| 20.00 mm| 500 m

Standards and Compliance

RoHS 2011/65/EU Restriction of Hazardous Substances
REACH Registration, Evaluation, Authorisation and Restriction of Chemicals
IEC 60092-360:2014 Electrical Installations in ships – Sheathing materials

for shipboard power and communication cable
IEC 60332.1| Fire retardancy of a single cable
IEC 60754.1| Amount of Halogen Gas Emissions
IEC 60754.2| Degree of acidity of released gases
IEC 61034.2| Measurement of smoke density