NOVITA ND298 Dehumidifier User Manual
- June 6, 2024
- NOVITA
Table of Contents
- NOVITA ND298 Dehumidifier
- PRODUCT DESCRIPTION
- HumiControl™ Accesso Pack (Optional)
- CONTROL PANEL DESCRIPTION
- TECHNICAL SPECIFICATIONS
- FEATURES
- USING THE NOVITA DEHUMIDIFIER
- CLEANING & MAINTENANCE
- TROUBLESHOOTING
- SAFETY INSTRUCTIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NOVITA ND298 Dehumidifier
PRODUCT DESCRIPTION
FRONT VIEW
- Semi-Permanent Built-In Ionizer
- Air Outlet
- Control Panel
- Front Panel Casing
BACKVIEW
- Rear Panel Casing
- Carrying Handle
- Power Cord & Plug
- Air Inlet Frame
- Pre-Filter Screen Handle
- Enhanced Dual Mesh Activated Carbon Filter°
- Continuous Drainage Outlet
- Water Tank
- Water Level Indicator
- Water Tank Handle
HumiControl™ Accesso Pack (Optional)
Enhanced Dual Mesh Activated Carbon Filter
CONTROL PANEL DESCRIPTION
- Power Control
- Timer
- RH¾ Setting
- Speed
- Anion Mode
- Anion Mode On Indicator
- High Fan Speed Indicator
- Low Fan Speed Indicator
- RH% Display
- Timer On Indicator
- Full Tank Indicator
- Power/Defrost Indicator
TECHNICAL SPECIFICATIONS
- Extraction Rate: 12 Litres / Day [30°C, 80% RH]
- Voltage/Frequency: 220 – 240 V / 50 Hz
- Rated Power: 156 Watts
- Max. Power: 210 Watts
- Humidity Setting: Available
- Auto Humidity Sensor: Available
- Continuous Drainage: Available
- Running Temperature: 5°C to 35°C
- Compressor: Reciprocating
- Refrigerant: R134A
- Weight: 11.4 KG
- Dimension [W x D x H]: 300 mm x 250 mm x 463 mm
- Tank Capacity: 2.6 Litres
- Air Flow:
- Low Fan 125 m3/hr
- High Fan 150 m3/hr
- Recommended Coverage: Dehumidifying Up to 300 ft² or 28 m²
- Negative Ion Density: Up to 20 Million/cm³
- Product Accessory
- PE Hose [12 mm inner diameter)
- HumiControl Accessory Pack (Optional) Includes 4 x Enhanced Dual Mesh Activated Carbon Filter
[Suggested Replacement: 3 Months]
FEATURES
Auto Humidi Sensor
Inbuilt hygrostat detects the humidity level of the surrounding and compares it to the humidity level set. The compressor stops operation and unit enters economical standby mode with low fan speed operating for 3 minutes before coming to a stop when the desired humidity is achieved. Compressor and preceding fan speed setting will reactivate when humidity level of the surrounding surpasses the desired humidity level.
Continuous Dehumidification Mode
Under continuous dehumidification mode, unit dehumidifies continuously regardless of humidity level in the surrounding. Dehumidification stops when the water tank is full.
Semi-Permanent Built-in Ionizer
Unit is equipped with a semi-permanent built-in ionizer which produces million of negative ions per cm’ to freshen up the air quality while eliminating airborne allergens and germs.
Room Humidity Display
LED displays the relative humidity level of the room/surrounding. This allows for easy reference and facilitates the adjustments accordingly to individual preference.
Timer
At On Mode, the unit can be programmed with a timer from 01 to 24 hours at an interval of 1 hour for an automatic shutoff. Timer indicator illuminates when timer function is activated.
Preferred Humidity Setting
User can set the humidity level according to individual’s desire within a range of 30% to 80% RH interval of 5% RH or Continuous Dehumidification Mode. Selected RH% level will be displayed on the LED screen.
Fan Speed Setting Option
Packed with 2 fan speed setting of Low and High to satisfy different usage requirement.
Childlock Function
To guard against curious kids, unit is equipped with a Childlock function to
prevent mishandling/mis-activated by young children who may change the
operation unintentionally. To activate child lock function, simply press
and hold Speed button for 2 seconds.
Auto Shut Off
Unit shuts off automatically with full water tank indicator illuminates and buzzer alarm goes off 5 times in following circumstances:
- Water tank is full (with buzzer alarm goes off for 5 times).
- Water tank is not placed properly.
- Water tank is removed.
Defrost Mode
Defrost Mode will be activated automatically when room temperature drops to 4°C and below and power/defrost indicator will flashes quickly on the LED screen. Compressor shuts off and unit runs on high fan speed setting.
Pre-Filter Screen & Enhanced Dual Mesh Activated Carbon Filter
Pre-filter sieves out contaminants from the air that is drawn into the unit. This process increase the efficiency of the unit and helps to filter the air that is released back into the surroundings. Enhanced Dual Mesh Activated Carbon Filter• eliminates unpleasant odour from the air before dehumidification process begins. It is recommended to replace the Enhanced Dual Mesh Activated Carbon Filter° once every 3 months* for optimum performance.
Continuous Drainage Option
Continuous drainage option allows easy removal of collected water instead of
manually empty from the water tank.
Using the continuous drainage option:
- Turn off the power supply & unplug from the power supply.
- Remove the water tank from the unit.
- Insert the PE hose (12 mm inner diameter) through the drainage outlet. Ensure the hose must be placed in a downward angle.
- Place the water tank back to the unit. Always ensure the unit is placed on a stable and level surface for continuous drainage option, otherwise water will be channelled into the water tank instead. The dehumidifier is now ready for continuous drainage.
USING THE NOVITA DEHUMIDIFIER
Setting Up
- Remove all packaging materials and place the unit on a dry, stable and level surface.
- DO NOT remove the polystyrene from the water tank.
- From the back of the unit, grasp the Air Inlet Frame and pull it outwards to remove both the Air Inlet Frame and Pre-Filter Screen from the unit.
- To enhance the HumiControl™ experience, it is recommended to use the Enhanced Dual Mesh Activated Carbon Filter in conjunction with the dehumidification process. Remove the plastic packaging on the Enhanced Dual Mesh Activated Carbon Filter° and place it into the designated slot between the Air Inlet Frame and Pre-Filter Screen. Then proceed to re-attach the assembled Air Inlet Frame back onto the unit.
- Ensure there is a clearance of at least 50 cm from the air inlet and clearance of at least 10 cm from the air outlet.
- Connect power plug to the power supply and power on the unit. At standby mode, the unit will have its power indicator flashing slowly to indicate it is at energy-saving standby mode and accompanied with a short “beeping” sound.
Emptying Water Tank
novita Dehumidifier ND298 shuts off automatically when the water tank is full. Follow the simple steps below to empty the water tank.
-
Remove the water tank from the unit.
-
Remove the water tank cover and empty the content before placing the water tank back onto the unit.
Enhanced Dual Mesh Activated Carbon Filter Replacement
For an optimum HumiControl™ performance, it is recommended to replace the Enhanced Dual Mesh Activated Carbon Filter-0 once every 3 months* from initial usage.
-
From the back of the unit, grasp the Air Inlet Frame and pull it outwards to remove both the Air Inlet Frame and Pre-Filter Screen from the unit.
-
Hold onto the upper right-hand corner of the Air Inlet Frame and exert some pressure to press it downwards to release the Pre-Filter Screen from the catch. Repeat the step for the upper left-hand corner.
-
Remove the exhausted Enhanced Dual Mesh Activated Carbon Filter from its designated slot. Proceed to assemble the new Enhanced Dual Mesh Activated Carbon Filter onto the designated slot on the Air Inlet Frame.
-
Insert the bottom right-hand corner of the Pre-Filter Screen underneath the catch of the Air Inlet Frame first then repeat the step for the bottom left-hand corner.
-
Exert some pressure to press and hold onto the upper tabs of the Pre-Filter Screen then align and slot them into the designated catch on the Air Inlet Frame. Proceed to push up the Pre-Filter Screen tabs to ensure they are securely fastened.
-
Align and re-attach the Air Inlet Frame & Pre-Filter Screen back onto the unit.
CLEANING & MAINTENANCE
Cleanin the novita Dehumidifier
To ensure the effectiveness of the dehumidifier, it is recommended to clean & maintain the unit at least once a week.
- Disconnect the dehumidifier from the power supply.
- Use a soft cloth to gently wipe the outer case to remove dust.
- Remove stubborn stains with a mild household cleaner.
Cleaning the Pre-Filter Screen
For optimum performance, it is recommended to clean the Air Inlet Frame & Pre- Filter Screen once every two (2)weeks.
-
From the back of the unit, grasp the Air Inlet Frame and pull it outwards to remove both the Air Inlet Frame and Pre-Filter Screen from the unit.
-
Hold onto the upper right-hand corner of the Air Inlet Frame and exert some pressure to press it downwards to release the Pre-Filter Screen from the catch. Repeat the step for the upper left-hand corner.
-
Use a vacuum cleaner OR a brush to remove the lint collected. Use warm soapy water to wash the Pre-Filter Screen if required.
-
Air dry it and re-attach the Pre-Filter Screen onto the Air Inlet Frame.
-
Align and re-attach the assembled Air Inlet Frame and Pre-Filter Screen back onto the unit.
TROUBLESHOOTING
CONDITION
| POSSIBLE CAUSE|
POSSIBLE SOLUTION
---|---|---
Unit cannot be switched on|
- The power plug is not connected properly.
|
-
Insert the power plug into the main supply again.
-
The water tank is full.
|
-
Remove the water tank and empty it, then replace it into the unit again.
-
Water tank not placed properly.
|
-
Remove water tank and replace it into the unit again.
-
Power plug or cord damaged.
|
- Contact novita Customer Care Centre.
Fan not working|
- Motor may be malfunction.
|
- Contact novita Customer Care Centre.
Poor performance or not dehumidify ing at optimum capacity|
- Low temperature or the surrounding humidity level is too low.
|
-
Dehumidifier does not work as effectively as in low temperature. Effectiveness of dehumidifier increases as RH increases.
-
Pre-filter screen is dirty.
|
-
Clean the pre-filter screen.
-
Exceed recommended room coverage area.
|
-
Maximum room coverage area’ for ND298 to operate effectively:
- Dehumidifying Up to 300 ft’ or 28 m2
-
Exceed extraction capacity
|
-
Maximum extraction capacity for ND298 is 12 Litres/Day at 30°C/ 80%RH.
-
The surrounding humidity level is lower than the desired humidity level set.
|
- Set the desired RH% lower than the surrounding humidity level.
The RH% display is not showing the desired RH%set|
- The RH% is showing the current surrounding area RH%.
|
- Press the @RH% Setting button once to view the desired RH% set.
Excessive noise|
- Unit is placed on uneven surface.
|
-
Move unit to a level and stable surface
-
Loose or foreign particles inside the unit.
|
-
Contact novita Customer Care Centre.
-
Sound of flowing water.
|
-
This is normal.
-
Pre-filter screen is dirty.
|
- Clean the pre-filter screen.
Water in tank overflows|
- Water tank may be damaged.
|
-
Replace the water tank.
-
Float for water auto-sensor is not in place.
|
-
Replace or adjust the float.
-
Internal drainage passage is blocked or obstructed.
|
- Contact novita Customer Care Centre.
E1 error message flashes on the LED screen every 30 seconds|
- Temperature sensor malfunction.
|
- Contact novita Customer Care Centre.
E2 error message flashes on the LED screen every 30 seconds|
- Humidity sensor malfunction.
|
- Contact novita Customer Care Centre.
SAFETY INSTRUCTIONS
- Read the operating instructions carefully before using the dehumidifier & keep it for later reference.
- Persons who are not familiar with the operating instructions, as well as children & persons under the influence of medication, alcohol or drugs are not advised to operate the dehumidifier, or are only advised to operate it under supervision.
- DO NOT use the dehumidifier if there is any damage to the unit or power cord.
- Only operate the unit when it is completely assembled & on a stable and level surface. Placing the unit on uneven surfaces can result in water leakages or additional noise.
- DO NOT handle the unit with wet hands.
- Always use the correct power supply.
- DO NOT insert any foreign objects into any crevices of the unit.
- Keep the unit away from direct sunlight or heat sources.
- Disconnect the dehumidifier from the power supply:
- When emptying the water tank
- Before cleaning
- During assembly or dismantling the unit
- Before moving the unit
- Repairs of appliance should only be done by qualified service technicians. Improper repair work can cause considerable danger to the user.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>