PRODUCT DESCRIPTION

FRONT VIEW

Front View

  1. Semi-Permanent Built-In Ionizer
  2. Air Outlet
  3. Control Panel
  4. Front Panel Casing
BACKVIEW

Back View

  1. Rear Panel Casing
  2. Carrying Handle
  3. Power Cord & Plug
  4. Air Inlet Frame
  5. Pre-Filter Screen Handle
  6. Enhanced Dual Mesh Activated Carbon Filter°
  7. Continuous Drainage Outlet
  8. Water Tank
  9. Water Level Indicator
  10. Water Tank Handle

HumiControl™ Accesso Pack (Optional)

Enhanced Dual Mesh Activated Carbon Filter

Accessory Pack

CONTROL PANEL DESCRIPTION

Control Panel Description

  1. Power Control
  2. Timer
  3. RH¾ Setting
  4. Speed
  5. Anion Mode
  6. Anion Mode On Indicator
  7. High Fan Speed Indicator
  8. Low Fan Speed Indicator
  9. RH% Display
  10. Timer On Indicator
  11. Full Tank Indicator
  12. Power/Defrost Indicator

TECHNICAL SPECIFICATIONS

  • Extraction Rate: 12 Litres / Day [30°C, 80% RH]
  • Voltage/Frequency: 220 – 240 V / 50 Hz
  • Rated Power: 156 Watts
  • Max. Power: 210 Watts
  • Humidity Setting: Available
  • Auto Humidity Sensor: Available
  • Continuous Drainage: Available
  • Running Temperature: 5°C to 35°C
  • Compressor: Reciprocating
  • Refrigerant: R134A
  • Weight: 11.4 KG
  • Dimension [W x D x H]: 300 mm x 250 mm x 463 mm
  • Tank Capacity: 2.6 Litres
  • Air Flow:
    • Low Fan 125 m3/hr
    • High Fan 150 m3/hr
  • Recommended Coverage: Dehumidifying Up to 300 ft² or 28 m²
  • Negative Ion Density: Up to 20 Million/cm³
  • Product Accessory
    • PE Hose [12 mm inner diameter)
    • HumiControl Accessory Pack (Optional) Includes 4 x Enhanced Dual Mesh Activated Carbon Filter
      [Suggested Replacement: 3 Months]

FEATURES

Auto Humidi Sensor

Inbuilt hygrostat detects the humidity level of the surrounding and compares it to the humidity level set. The compressor stops operation and unit enters economical standby mode with low fan speed operating for 3 minutes before coming to a stop when the desired humidity is achieved. Compressor and preceding fan speed setting will reactivate when humidity level of the surrounding surpasses the desired humidity level.

Continuous Dehumidification Mode

Continuous Dehumidification Mode

Under continuous dehumidification mode, unit dehumidifies continuously regardless of humidity level in the surrounding. Dehumidification stops when the water tank is full.

Semi-Permanent Built-in Ionizer

Semi-Permanent Built-in Lonizer

Unit is equipped with a semi-permanent built-in ionizer which produces million of negative ions per cm’ to freshen up the air quality while eliminating airborne allergens and germs.

Room Humidity Display

Room Humidity Display

LED displays the relative humidity level of the room/surrounding. This allows for easy reference and facilitates the adjustments accordingly to individual preference.

Timer

Timer

At On Mode, the unit can be programmed with a timer from 01 to 24 hours at an interval of 1 hour for an automatic shutoff. Timer indicator illuminates when timer function is activated.

Preferred Humidity Setting

Preferred Humidity Setting

User can set the humidity level according to individual’s desire within a range of 30% to 80% RH interval of 5% RH or Continuous Dehumidification Mode. Selected RH% level will be displayed on the LED screen.

Fan Speed Setting Option

Fan Speed Setting Option

Packed with 2 fan speed setting of Low and High to satisfy different usage requirement.

Childlock Function

Childlock Function

To guard against curious kids, unit is equipped with a Childlock function to prevent mishandling/mis-activated by young children who may change the operation unintentionally. To activate child lock function, simply press
and hold Speed button for 2 seconds.

Auto Shut Off

Auto Shut Off

Unit shuts off automatically with full water tank indicator illuminates and buzzer alarm goes off 5 times in following circumstances:

  • Water tank is full (with buzzer alarm goes off for 5 times).
  • Water tank is not placed properly.
  • Water tank is removed.
Defrost Mode

Defrost Mode

Defrost Mode will be activated automatically when room temperature drops to 4°C and below and power/defrost indicator will flashes quickly on the LED screen. Compressor shuts off and unit runs on high fan speed setting.

Pre-Filter Screen & Enhanced Dual Mesh Activated Carbon Filter

Pre-filter sieves out contaminants from the air that is drawn into the unit. This process increase the efficiency of the unit and helps to filter the air that is released back into the surroundings. Enhanced Dual Mesh Activated Carbon Filter• eliminates unpleasant odour from the air before dehumidification process begins. It is recommended to replace the Enhanced Dual Mesh Activated Carbon Filter° once every 3 months* for optimum performance.

Pre-Filter Screen & Enhanced Dual Mesh Activated Carbon
Filter

Continuous Drainage Option

Continuous drainage option allows easy removal of collected water instead of manually empty from the water tank.
Using the continuous drainage option:

  1. Turn off the power supply & unplug from the power supply.
  2. Remove the water tank from the unit.
  3. Insert the PE hose (12 mm inner diameter) through the drainage outlet. Ensure the hose must be placed in a downward angle.
  4. Place the water tank back to the unit. Always ensure the unit is placed on a stable and level surface for continuous drainage option, otherwise water will be channelled into the water tank instead. The dehumidifier is now ready for continuous drainage.

Continuous Drainage Option

USING THE NOVITA DEHUMIDIFIER

Setting Up
  1. Remove all packaging materials and place the unit on a dry, stable and level surface.
    • DO NOT remove the polystyrene from the water tank.
  2. From the back of the unit, grasp the Air Inlet Frame and pull it outwards to remove both the Air Inlet Frame and Pre-Filter Screen from the unit.
  3. To enhance the HumiControl™ experience, it is recommended to use the Enhanced Dual Mesh Activated Carbon Filter in conjunction with the dehumidification process. Remove the plastic packaging on the Enhanced Dual Mesh Activated Carbon Filter° and place it into the designated slot between the Air Inlet Frame and Pre-Filter Screen. Then proceed to re-attach the assembled Air Inlet Frame back onto the unit.
  4. Ensure there is a clearance of at least 50 cm from the air inlet and clearance of at least 10 cm from the air outlet.
  5. Connect power plug to the power supply and power on the unit. At standby mode, the unit will have its power indicator flashing slowly to indicate it is at energy-saving standby mode and accompanied with a short “beeping” sound.
Emptying Water Tank

novita Dehumidifier ND298 shuts off automatically when the water tank is full. Follow the simple steps below to empty the water tank.

  1. Remove the water tank from the unit.
    Emptying the Water Tank 01

  2. Remove the water tank cover and empty the content before placing the water tank back onto the unit.

Enhanced Dual Mesh Activated Carbon Filter Replacement

For an optimum HumiControl™ performance, it is recommended to replace the Enhanced Dual Mesh Activated Carbon Filter-0 once every 3 months* from initial usage.

  1. From the back of the unit, grasp the Air Inlet Frame and pull it outwards to remove both the Air Inlet Frame and Pre-Filter Screen from the unit.
    Enhanced Dual Mesh Activated Carbon Filter Replacement
01

  2. Hold onto the upper right-hand corner of the Air Inlet Frame and exert some pressure to press it downwards to release the Pre-Filter Screen from the catch. Repeat the step for the upper left-hand corner.
    Enhanced Dual Mesh Activated Carbon Filter Replacement
02

  3. Remove the exhausted Enhanced Dual Mesh Activated Carbon Filter from its designated slot. Proceed to assemble the new Enhanced Dual Mesh Activated Carbon Filter onto the designated slot on the Air Inlet Frame.
    Enhanced Dual Mesh Activated Carbon Filter Replacement
03

  4. Insert the bottom right-hand corner of the Pre-Filter Screen underneath the catch of the Air Inlet Frame first then repeat the step for the bottom left-hand corner.Enhanced Dual Mesh Activated Carbon Filter Replacement 04

  5. Exert some pressure to press and hold onto the upper tabs of the Pre-Filter Screen then align and slot them into the designated catch on the Air Inlet Frame. Proceed to push up the Pre-Filter Screen tabs to ensure they are securely fastened.Enhanced Dual Mesh Activated Carbon Filter Replacement 05

  6. Align and re-attach the Air Inlet Frame & Pre-Filter Screen back onto the unit.Enhanced Dual Mesh Activated Carbon Filter Replacement 06

CLEANING & MAINTENANCE

Cleanin the novita Dehumidifier

To ensure the effectiveness of the dehumidifier, it is recommended to clean & maintain the unit at least once a week.

  1. Disconnect the dehumidifier from the power supply.
  2. Use a soft cloth to gently wipe the outer case to remove dust.
  3. Remove stubborn stains with a mild household cleaner.

Cleaning Dehumidifier

Cleaning the Pre-Filter Screen

For optimum performance, it is recommended to clean the Air Inlet Frame & Pre- Filter Screen once every two (2)weeks.

  1. From the back of the unit, grasp the Air Inlet Frame and pull it outwards to remove both the Air Inlet Frame and Pre-Filter Screen from the unit.
    Cleaning Pre-Filter Screen 01

  2. Hold onto the upper right-hand corner of the Air Inlet Frame and exert some pressure to press it downwards to release the Pre-Filter Screen from the catch. Repeat the step for the upper left-hand corner.Cleaning Pre-Filter Screen 02

  3. Use a vacuum cleaner OR a brush to remove the lint collected. Use warm soapy water to wash the Pre-Filter Screen if required.Cleaning Pre-Filter Screen 03

  4. Air dry it and re-attach the Pre-Filter Screen onto the Air Inlet Frame.Cleaning Pre-Filter Screen 04

  5. Align and re-attach the assembled Air Inlet Frame and Pre-Filter Screen back onto the unit.Cleaning Pre-Filter Screen 05

TROUBLESHOOTING

CONDITION

| POSSIBLE CAUSE|

POSSIBLE SOLUTION

---|---|---
Unit cannot be switched on|

  • The power plug is not connected properly.

|

  • Insert the power plug into the main supply again.

  • The water tank is full.

|

  • Remove the water tank and empty it, then replace it into the unit again.

  • Water tank not placed properly.

|

  • Remove water tank and replace it into the unit again.

  • Power plug or cord damaged.

|

  • Contact novita Customer Care Centre.

Fan not working|

  • Motor may be malfunction.

|

  • Contact novita Customer Care Centre.

Poor performance or not dehumidify­ ing at optimum capacity|

  • Low temperature or the surrounding humidity level is too low.

|

  • Dehumidifier does not work as effectively as in low temperature. Effectiveness of dehumidifier increases as RH increases.

  • Pre-filter screen is dirty.

|

  • Clean the pre-filter screen.

  • Exceed recommended room coverage area.

|

  • Maximum room coverage area’  for ND298 to operate effectively:

    • Dehumidifying Up to 300 ft’ or 28 m2
  • Exceed extraction capacity

|

  • Maximum extraction capacity for ND298 is 12 Litres/Day at 30°C/ 80%RH.

  • The surrounding humidity level is lower than the desired humidity level set.

|

  • Set the desired RH% lower than the surrounding humidity level.

The RH% display is not showing the desired RH%set|

  • The RH% is showing the current surrounding area RH%.

|

  • Press the @RH% Setting button once to view the desired RH% set.

Excessive noise|

  • Unit is placed on uneven surface.

|

  • Move unit to a level and stable surface

  • Loose or foreign particles inside the unit.

|

  • Contact novita Customer Care Centre.

  • Sound of flowing water.

|

  • This is normal.

  • Pre-filter screen is dirty.

|

  • Clean the pre-filter screen.

Water in tank overflows|

  • Water tank may be damaged.

|

  • Replace the water tank.

  • Float for water auto-sensor is not in place.

|

  • Replace or adjust the float.

  • Internal drainage passage is blocked or obstructed.

|

  • Contact novita Customer Care Centre.

E1 error message flashes on the LED screen every 30 seconds|

  • Temperature sensor malfunction.

|

  • Contact novita Customer Care Centre.

E2 error message flashes on the LED screen every 30 seconds|

  • Humidity sensor malfunction.

|

  • Contact novita Customer Care Centre.

SAFETY INSTRUCTIONS

  1. Read the operating instructions carefully before using the dehumidifier & keep it for later reference.
  2. Persons who are not familiar with the operating instructions, as well as children & persons under the influence of medication, alcohol or drugs are not advised to operate the dehumidifier, or are only advised to operate it under supervision.
  3. DO NOT use the dehumidifier if there is any damage to the unit or power cord.
  4. Only operate the unit when it is completely assembled & on a stable and level surface. Placing the unit on uneven surfaces can result in water leakages or additional noise.
  5. DO NOT handle the unit with wet hands.
  6. Always use the correct power supply.
  7. DO NOT insert any foreign objects into any crevices of the unit.
  8. Keep the unit away from direct sunlight or heat sources.
  9. Disconnect the dehumidifier from the power supply:
    • When emptying the water tank
    • Before cleaning
    • During assembly or dismantling the unit
    • Before moving the unit
  10. Repairs of appliance should only be done by qualified service technicians. Improper repair work can cause considerable danger to the user.

Read User Manual Online (PDF format)