About

The Invitation Lithium Legion application can be downloaded to smartphones from the Apple App Store and Google Play for free. It is designed to work with SNELL, SNOWBELT, and SOL* batteries. If using on SOL batteries, this will have limited functionality, but no less then the original app. This app is not designed to work with SNELL or SNARLS.

The application integrates Bluetooth technology with the MS software to view, monitor, manage, and control individual and/or multiple batteries. The Legion app is required if setting up SNELL batteries in multiple systems or in parallel and/or series systems.
QR Code


Tips

  • If using a SNELL battery or SNOWBELT device, ensure the battery is turned on
  • Ensure phone Bluetooth is turned on
  • SOL Batteries will have limited functionality
  • Not intended for SNELL and SNARLS batteries
  • Allow location services
  • Only one phone can be connected to a battery/system at a time
  • Ensure the battery is not in sleep mode
  • Password to change battery name: 1234
  • Original battery name can be found on the silver sticker – SPBXXXXXXXXXXXX
  • If batteries or cells become out of balance, perform at least two full discharge and charge cycles (0%-100%) before contacting customer service. A difference of 3% per battery and 300mV per cell is acceptable.

Home Screen

Home Screen

  1. Select this to view more options eg. language, unit, app version, company information
  2. Select this to monitor a single battery
  3. Select this to set up and monitor multiple batteries in a wireless system
  4. Select this to set up and monitor multiple batteries in a wired system via CAN bus
  5. Select this to monitor the Invitation Golf Cart batteries via the Bluetooth module SNOWBELT
  6. *If monitoring a SNL battery, the user will only be able to use the ‘Invitation Battery’ function with limited functionality

Invicta Battery Function

Search interface

  • Support fuzzy search device, use this to find your battery
  • Displays Bluetooth name, signal strength, (SOC, address available SNLX batteries only)

Device Overview Page
Invitation Battery Function

  1. Page
    Device name – click three dots to change. Password is 1234
    Info – General monitoring information
    Log – Recorded protections
    Details – Current protections and cell information

  2. SOC of equipment:
    SOC <20%: icon in red
    SOC >20%: icon is green

  3. The health status of the device

  4. Current status of the device:
    Standby: No identification
    Charging: Lightning symbol flashing
    During Discharge: the lightning sign remains on

  5. The usable time of the device

  6. Current: positive charging value, negative discharging value

  7. Capacity: Equipment design capacity

  8. Voltage: Current voltage of the device

  9. Power: Power = Voltage x Current

  10. Temperature: device average temperature

  11. Number of cycles

Invicta Battery Function cont.

Log Page
Invitation Battery Function cont

  1. This will show recent protections. Logs are recorded for a limited time and will reset.

Details Page
Invitation Battery Function cont

  1. This will show current protections as red.
    HV – High Voltage
    LV – Low Voltage
    COC – Charge Over Current
    DOC – Discharge Over Current
    DLT – Discharge Low Temp.
    CLT – Charge Low Temp.
    DHT – Discharge High Temp.
    CHT – Charge High Temp.

  2. Cell voltage – 300mV difference is acceptable. If difference is more, perform full discharge and charge cycle (0%-100%) at least two times before contacting customer service.

Important! Read Before Setting Up A Series or Parallel System

Important Information

  1. Refer to the battery manual before setting up in series and/or parallel
  2. Before connecting in series or parallel, ensure the batteries are off.
  3. Once the batteries are off, connect the battery leads in a series and/or parallel configuration
  4. Connect your accessories and check all connections are secure.
  5. It is prefered to use Wired System Connection where possible
  6. Bluetooth System can be used for Parallel or Series, not both
  7. Wired System can be used for Parallel and/or Series
    Read Before Setting
    Series example: 2 x 12V.8100Ah
    System voltage : 12.8*2=25.6V
    System capacity : 100Ah
    Read Before Setting
    Parallel example: 2 x 12.8V100Ah
    System voltage: 12.8V
    System capacity : 100Ah + 100Ah = 200Ah

Max Bluetooth Configuration S = Series / P = Parallel
12V System
1S + 16P
2S 1P
3S 1P
4S 1P

Max Wired Configuration S = Series / P = Parallel
12V System
1S + 16P
2S 4P
3S 4P
4S 4P

BT System Connection

Setup
BT System Connection

Use this system to connect and monitor multiple batteries in series or parallel via a inter-battery Bluetooth connection. The user can set up multiple systems and monitor individual batteries in the system. Users can also connect and monitor multiple batteries via a wired connection, and is the preferred method if possible. See Wired System Connection for this method

To set up a BT system please follow the steps below.
BT System Connection

  1. Before connecting in series or parallel, ensure the batteries are off.

  2. Once the batteries are off, connect the battery leads in a series or parallel configuration

  3. Connect your accessories and check all connections are secure

  4. Turn the batteries on and wait 10 seconds for power to be supplied

  5. Open Invicta Legion Application and click BT System connection

  6. Click the + sign and set the system name, voltage platform, series or parallel connection and quantity of batteries in the system.
    BT System Connection

  7. Select the corresponding battery name to the corresponding position in the system

  8. Ensure battery one is in the first position, battery two is in the second position etc.

  9. For example – in a four battery system, do not place battery three in the first position.

  10. Press save. To change or remove the system, press Reconfigure or Release.

  11. Attention third party installers – After testing on your phone, it is important to release the network and set it up on the customers phone during hand over.

Wired System Connection

Setup
Use this system to connect and monitor multiple batteries in series and/or parallel via a wired/CAN bus connection. This is the preferred method when possible.

To set up a Wired system please follow the steps below.

  1. Before connecting in series or parallel, ensure the batteries are off.

  2. Once the batteries are off, connect the battery leads in a series and/or parallel configuration
    Wired System Connection
    Series example : 2 x 12V.8100Ah
    System voltage : 12.8*2=25.6V
    System capacity: 100Ah
    Wired System Connection
    Parallel example : 2 x 12.8V100Ah
    System voltage: 12.8V
    System capacity : 100Ah + 100Ah = 200Ah

  3. Connect your accessories and check all connections are secure. If using a communication device, connect to Link-In on Battery 1. Only use approved Invitation Link Cables for connection to devices

  4. Connect inter-battery Link cables. Only use approved Invicta Link Cables for inter-battery connection.

  5. Battery 1 – Link Out > Battery 2 – Link In

  6. Battery 2 – Link Out > Battery 3 – Link In etc.
    **Wired System Connection cont.

**

  1. Turn the batteries on in sequence and wait 10 seconds for power to be supplied. Press and hold reset button for 20 sec. on Battery 1. Wait for lights to run and stop.
    This will take approx 2 min.

  2. Open Invicta Legion Application and click Wired System connection

  3. Click the + sign and set the system name, voltage platform, series or parallel connection and quantity of batteries in the system.
    Max Configuration – S = Series / P = Parallel

    12V System| 24V System| 36V System| 48V System
    1S + 16P| 1S 4P| 1S 4P| 1S 4P
    2S 4P|
    3S 4P
    4S 4P

Wired System Connection cont.

  1. Press Select Master Battery
  2. Select Master Batter (Battery 1)
  3. Ensure the corresponding battery name is connected to the corresponding position in the system
  4. Ensure battery one (Master) is in the first position, battery two is in the second position etc.
  5. For example – in a four battery system, do not place battery three in the first position.
  6. Press save. To change or remove the system, press Reconfigure or Release.
  7. Attention third party installers – After testing on your phone, it is important to release the network and set it up on the customers phone during hand over.

Golf Cart/Motive Module

Golf Cart/Motive Monitoring
Golf Cart/Motive Module
Golf Cart/Motive Module
Golf Cart/Motive Module

  1. Ensure the battery/s are in the off position before configuration
  2. Connect the battery and module as per the instructions.
  3. Important tip – ensure battery is setup in parallel configuration (do not series or parallel master slave)
  4. Important tip – ensure the resistor cable is connected on the battery (not the module)
  5. Once all connections are secured, turn the battery/s on. Wait 2 minutes, blue light on module will be active
  6. Open Golf Cart/Motive Module function
  7. Select the module
  8. Check Log page – this will show any protections
  9. Check Details page – this has individual battery information. Click battery to view battery information

SPB logo

SPB Sydney Office : 2/28 Prime Drive, Seven Hills New South Wales, 2147
SPB Melbourne Office : 3/35 Dunlap Road, Gravel, Melbourne, VIC, 3170
SPB National Head Office: 1 Ant Road, Yatala, Brisbane, QLD 4207
T 1300 001 772 E info@spb.net.au W spb.net.au

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals