Specifications

  • Model: Vallox Adjustment Damper
  • Document: D11495
  • Valid from: 01.07.2024
  • Updated: 02.06.2024

Product Information

The Vallox Adjustment Damper can be used to balance the underpressure created by cooker hood boost and general extraction. It receives information from the cooker hood about the opening of the hood damper and adjusts the supply air volume accordingly. The damper automatically opens and closes based on the status data of the cooker hood damper.

Product Usage Instructions

Installation

  1. Ensure all power sources are switched off before installation.
  2. Mount the adjustment damper in a suitable location in the ventilation system.
  3. Connect the necessary power supply as per the technical specifications.

Operation in Apartment Buildings with Central Ventilation
Ensure proper connection of intake and exhaust air according to the specified airflow rates for balanced ventilation.

Maintenance
Regularly check the adjustment damper for any debris or blockages that may affect its operation. Clean if necessary.

FAQ

  • How does the adjustment damper work with the cooker hood?
    The adjustment damper receives signals from the cooker hood to regulate the supply air volume based on the hood damper’s status.

  • Can the adjustment damper be manually controlled?
    No, the adjustment damper operates automatically based on the cooker hood’s activity.

PRODUCT DESCRIPTION

  • Vallox Adjustment Damper can be used to balance the underpressure created by cooker hood boost and general extraction. The adjustment damper receives information from the cooker hood about the opening of the hood damper and increases the supply air introduced into the home by the corresponding volume. The adjustment damper closes and opens automatically in accordance with the status data of the cooker hood damper.
  • The adjustment damper includes the actuator, and Vallox Adjustment Damper 230 V versions can be controlled directly with the Vallox X-Line KTXA and Vallox Delico KTD A cooker hoods without separate supply voltage. The Vallox Adjustment Damper 24 V versions always need an external 24 V voltage supply (either an external transformer or supply voltage from the distribution board).

PRODUCT INFORMATION

Product code| Product title| HVAC code| GTIN code
---|---|---|---
975175| Vallox Adjustment Damper 24 V / 100 mm| 8413502| 6438326001410
975180| Vallox Adjustment Damper 230 V / 100 mm| 8413500| 6438326001397
975185| Vallox Adjustment Damper 24 V / 125 mm| 8413503| 6438326001427
975190| Vallox Adjustment Damper 230 V / 125 mm| 8413501| 6438326001403

TECHNICAL SPECIFICATIONS

Material of casing and adjustment damper Galvanised steel
Tightness class according to EN 1751, class 4
Weight 100 mm = 0.5 kg / 125 mm = 0.62 kg
Actuator Vallox Adjustment Damper 230 V Belimo LM230A, 5 Nm, 12 VA

/ 1 W
Actuator Vallox Adjustment Damper 24 V| Belimo LM24A, 5 Nm, 3 VA / 2 W

DIMENSIONS

ELECTRICAL CONNECTION

ADJUSTMENT

  • The factory settings of the opening and closing angles are such that the adjustment damper opens and closes completely. However, the opening and closing angles can be adjusted.
  • The air flow is adjusted so that the air volume introduced into the room corresponds to the volume of the extract air flow from the cooker hood. Air volumes are always measured from the terminal device, and the terminal device is adjusted in accordance with ventilation in the Boost mode.
  • The At home mode air flow is adjusted when the adjustment damper is fully closed. If general extraction from the hood is to be compensated for, the adjustment damper limiter is moved so that the adjustment damper will not close completely.
  • The Boost mode air flow is adjusted when the cooker hood damper is open. The air flows are adjusted from the terminal device.

CONNECTION WITH COOKER HOOD AND CONTROL OPTIONS

Vallox Delico KTD A cooker hood and Vallox Adjustment Damper 230 V

  • LK = Vallox Delico KTD A cooker hood
  • SR= Vallox Smoke Limiter
  • VS = Vallox Adjustment Damper 230 V
  • Control of adjustment damper = Distribution box on top of the hood (on the left)
  • When Vallox Delico KTD A is connected to the joint extraction system of a multi-storey building, a smoke limiter must also be installed.
  • Vallox Smoke Limiter meets the requirements set for a choke that serves as a fire damper(max 42 l/s @ 100 pa).
  • The minimum air flow is adjusted from the cooker hood damper and the maximum air flow from the smoke limiter.

Vallox Delico KTD A cooker hood and Vallox Adjustment Damper 24 V

  • 24 V adjustment damper requires separate voltage supply (either external

  • 24 V transformer or voltage supply from distribution board)

  • 24 V adjustment damper power consumption = 2 W

  • LK = Vallox Delico KTD A cooker hood

  • SR= Vallox Smoke Limiter

  • VS = Vallox Adjustment Damper 24 V

  • Adjustment damper control = DAMP IN & DAMP OUT (status data of the hood damper)

  • When Vallox Delico KTD A is connected to the joint extraction system of a multi-storey building, a smoke limiter must also be installed.

  • Vallox Smoke Limiter meets the requirements set for a choke that serves as a fire damper (max 42 l/s @ 100 pa).

  • The minimum air flow is adjusted from the cooker hood damper and the maximum air flow from the smoke limiter.

Vallox X-Line KTXA cooker hood and Vallox Adjustment Damper 230 V

  • 230 V adjustment damper receives supply voltage directly from the cooker hood.

  • 230 V adjustment damper power consumption = 1 W.

  • LK = Vallox X-Line KTXA cooker hood

  • SR= Vallox Smoke Limiter

  • VS = Vallox Adjustment Damper 230 V Adjustment damper control = Hood damper status. L (continuous 230 V supply) must be connected from the hood.

  • When Vallox X-line KTX A is connected to the joint extraction system of a multi-storey building, a smoke limiter must also be installed.

  • Vallox Smoke Limiter meets the requirements set for a choke that serves as a fire damper (max 42 l/s @ 100 pa).

Vallox X-Line KTXA cooker hood and Vallox Adjustment Damper 24 V

  • 24 V adjustment damper requires separate voltage supply (either external

  • 24 V transformer or voltage supply from distribution board).

  • 24 V adjustment damper power consumption = 2 W.

  • LK = Vallox X-Line KTXA cooker hood

  • SR= Vallox Smoke Limiter

  • VS = Vallox Adjustment Damper 24 V

  • Adjustment damper control = Hood damper status data directs 24 V voltage to the adjustment damper.

  • When Vallox X-line KTX A is connected to the joint extraction system of a multi-storey building, a smoke limiter must also be installed.

  • Vallox Smoke Limiter meets the requirements set for a choke that serves as a fire damper (max 42 l/s @ 100 pa).

OPERATION IN MULTI-STOREY BUILDINGS, CENTRALISED VENTILATION

Cooker hood damper closed

Cooker hood damper open

Standard extraction from kitchen through cooker hood, hand dampar clacad

DECLARATION OF CONFIRMITY

ABOUT COMPANY

  • Vallox Oy
  • Myllykylantie 9-11
  • Fl-32200 LOIMAA
  • FINLAND
  • Tel. +358 10 7732 200
  • Fax. +358 10 7732 201
  • www.vallox.com
  • firstname.familyname@vallox.com
  • ALV rek .lVAT
  • Y-tunnus I Business ID:
  • KotipaikkalRegistered Domicile:
  • FI06723509
  • 0672350-9
  • Loimaa, Finland

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals