VALLOX 096 MV Ceiling Mounting Plate Instruction Manual

June 1, 2024
VALLOX

VALLOX-logo

VALLOX 096 MV Ceiling Mounting Plate

VALLOX-096-MV-Ceiling-Mounting-Plate-product

Specifications

  • Model: Vallox 096 MV
  • Document: D4533
  • Valid from: 16.04.2024
  • Updated: 01.02.2024

Product Usage Instructions

Fastening the Ceiling Mounting Plate

  1. Fasten the M8 thread bars on the rafter frames or other frame structures and secure the nuts onto the bars.
  2. Lift the ceiling mounting plate in place.
  3. Push a rubber damper and a washer to each thread bar.
  4. Adjust the nuts to ensure the ceiling mounting plate is level.

Installation Process

  1. Ensure that the end of the thread bar is 5 mm or less below the fastening nut.
  2. Do not overtighten the ceiling mounting plate to the ceiling; leave nuts above the plate to prevent lifting during unit mounting.
  3. Check condensate insulation rings are in place below the ceiling mounting plate.

Attaching the Ventilation Unit

  1. Remove the door from the unit before attaching it to the ceiling mounting plate.
  2. Lift the unit close to the ceiling mounting plate and feed cables through the hole in the plate.
  3. Make a service door in the ceiling for cable access, approximately 500 mm from the ceiling mounting plate.

Locking the Ventilation Unit

  1. Lift the unit against the ceiling mounting plate and release the locking levers by turning them towards the center of the unit.
  2. If needed, guide mounting hooks on the plate to grooves on the unit’s side panels.

Frequently Asked Questions (FAQ)

Q: How do I ensure that the ceiling mounting plate is securely attached?

A: Tighten the upper nut of the thread bars adequately to prevent the ceiling mounting plate from rising upwards.

Q: Can I detach the ventilation unit from the ceiling mounting plate?

A: Yes, you can detach the unit by following the specified steps, including removing the door, lifting the unit upwards, and unlocking the operating levers.

Installation instructions

  1. Fasten the M8 thread bars on the rafter frames or other frame structures and fasten the nuts onto the bars (1).
  2. Lift the ceiling mounting plate in place.
  3. Push a rubber damper (3) and a washer (2) to each thread bar.
  4. Adjust the nuts so that the ceiling mounting plate is level.
    • NOTE! The end of the thread bar must be 5 mm or less below the fastening nut. Do not fasten the ceiling mounting plate too tight to the ceiling.
    • There must be nuts (1) above the ceiling mounting plate to prevent the plate from lifting when the unit is being mounted. Pull from the operating levers (A) to ensure that the sliding bars move and restore to their original position.
    • The upper edge of the ceiling mounting plate can be installed against the ceiling. Alternatively, a concealed mounting method can be used, in which case the ceiling can be 30 mm below the upper edge.
  5. Check that the condensate insulation rings (at least exhaust air and outdoor air duct) are in place in the outlet collars below the ceiling mounting plate.
  6. Pull the operating levers (A) out and lock them by turning them towards the outer sides of the unit.
  7. Remove the door before installing the ventilation unit to the ceiling mounting plate.VALLOX-096-MV-Ceiling-Mounting-Plate-fig-1
  8. Lift the ventilation unit close to the ceiling mounting plate and feed the cables and the connection box through the hole in the ceiling mounting plate on top of the ceiling.
    • NOTE! Remember to make a service door in the ceiling so that the cables and the connection box can be accessed. The distance between the service door and the ceiling mounting plate should be around 500 mm. Alternatively, the cables can be fed between the ceiling mounting plate and the ventilation unit to therear wall.
  9. Lift the ventilation unit against the ceiling mounting plate and release the locking of the levers (A) by turning them towards the center of the unit; the levers will lock the unit to the ceiling mounting plate. Where needed, guide the mounting hooks on the ceiling mounting plate (B) to the grooves on the side panels of the ventilation unit. In the locked position, the levers are at the same level as the front edge of the ceiling mounting plate.
  10. Where required, the unit can be detached from the ceiling mounting plate. Remove the door of the unit, lift the unit slightly upwards, pull out both operating levers (A) and lock them (see section 6).
  11. Nut M8
  12. Washer
  13. Vibration rubber damper
  14. Thread bar M8
  • There is a gap of about 2 mm at the edges between the ceiling mounting plate and the 096 unit.
  • NOTE Installing the ventilation unit to the ceiling mounting plate. See the ventilation unit manual.
  • NOTE Tighten the upper nut of the thread bars adequately so that the ceiling mounting plate cannot rise upwards.

Dimension

Dimensions and duct outletsVALLOX-096-MV-Ceiling-Mounting-Plate-
fig-3

Duct outlets

  1. Supply air from the unit to the apartment
  2. Extract air from the apartment to the unit
  3. Exhaust air flowing outdoors from the unit
  4. Outdoor air to the unit
    • 10   mm Distance from the finished rear wall
    • Recommended distance from the finished side wall VALLOX-096-MV-Ceiling-Mounting-Plate-fig-5
    • max. 30 mm
    • Concealed installation of the ceiling mounting plate on the ceilingVALLOX-096-MV-Ceiling-Mounting-Plate-fig-6
  • www.vallox.com
  • Vallox Oy 9-11 | 32200 LOIMAA | FINLAND
  • © Vallox – All rights reserved

Documents / Resources

| VALLOX 096 MV Ceiling Mounting Plate [pdf] Instruction Manual
096 MV Ceiling Mounting Plate, 096 MV, Ceiling Mounting Plate, Mounting Plate, Plate
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals