DALC NET LINE-4CC-DMX Lighting Unit
Specifications
Product Code | LINE-4CC-DMX |
---|---|
Supply Voltage | 12-24-48 VDC |
LED Output | 4 x 0.9 A (total max 3.6 A) |
Product Description
LINE-4CC-DMX is a dimmer device with various features including PWM Frequency,
Dimming Curve, Power-ON Levels, and DMX Personality.
It offers Opto-Isolated DMX Input, Soft ON/OFF, Soft brightness dimming, and
operates within an extended temperature range. The product undergoes a 100%
Functional test.
Technical Specifications
Efficiency at Full Load | > 95% |
---|---|
Power Consumption in Standby Mode | < 0.5 W |
Installation
ATTENTION! Installation and maintenance should always be done without voltage. Prior to connecting the device to the power supply, ensure the power source voltage is disconnected from the system. Installation should be performed by qualified personnel following regulations, legislation, and standards.
- Load Connection: Connect the LED load positive to the L terminal with the + symbol, and the negatives to L1, L2, L3, and L4 terminals with the – symbol.
FAQ
-
What is the maximum dimming resolution of LINE-4CC-DMX?
The dimming resolution is 16 bit. -
What are the protection features of LINE-4CC-DMX?
The device includes Input Fuse Protection, Over Voltage Protection, Under Voltage Protection, and Reverse Voltage Polarity.
FEATURES
- DIMMER LED DMX
- Power Input: 12-24-48 Vdc
- Constant Current Output for dimmable spotlights and LED modules
- WHITE, SINGLE COLOR, TUNABLE WHITE, RGB, and RGB+W Light Control
- Remote control via BUS (DMX512-A+RDM)
- Device configuration via Dalcnet LightApp© mobile application
- Constant voltage outputs for R-L-C loads
- PWM modulation can be set from 300 to 3400 Hz
- Parameters can be set from mobile application and via RDM:
- PWM Frequency
- Dimming Curve
- Power-ON Levels
- DMX Personality
- Operating hours and ignition cycles parameters
- Ingress Protection
- Opto-Isolated DMX Input
- Soft ON/OFF
- Soft brightness dimming
- Extended temperature range
- 100% Functional test
PRODUCT DESCRIPTION
LINE-4CC-DMX is a PWM (Pulse With Modulation) Constant Current (CC) LED dimmer
with 4 output channels and remotely controllable via DMX (Digital Multiplex)
digital protocol. It can be connected to a constant voltage (12 ÷ 48) Vdc SELV
power supply and is suitable for driving loads such as Spotlight and white,
single-colour, Tunable White, RGB and RGB+W constant current LED modules.
LINE-4CC-DMX can deliver a maximum output current of 900 mA per channel and
has the following protections: over-power protections, reverse polarity
protection, and input fuse protection.
Through the Dalcnet LightApp© mobile application and smartphone equipped with
Near Field Communication (NFC) technology, it is possible to configure
multiple parameters including modulation frequency, adjustment curve and
maximum/minimum brightness levels when the device is switched off. Dalcnet
LightApp© can be downloaded free of charge from the Apple APP Store and Google
Play Store.
⇢ For the up-to-date manual, please consult our website
www.dalcnet.com or QR Code.
PRODUCT CODE
CODE| SUPPLY VOLTAGE| LED OUTPUT| N° OF CHANNELS|
REMOTE CONTROL (BUS)| APP CONFIG.
---|---|---|---|---|---
LINE-4CC- DMX| 12-24-48 VDC| 4 x 0.9 A (tot. max 3.6 A) 1| 4|
DMX512-RDM| LightApp©
Table 1: Product code
PROTECTIONS
The following table shows the types of incoming protections present on the device.
ACRONYM | DESCRIPTION | TERMINAL | PRESENT |
---|---|---|---|
IFP | Input Fuse Protection2 | DC IN | ✔ |
OVP | Over Voltage Protection2 | DC IN | ✔ |
UVP | Under Voltage Protection | DC IN | ✔ |
RVP | Reverse Voltage Polarity2 | DC-IN | ✔ |
Table 2: Protection & Detection Features
REFERENCE STANDARDS
LINE-4CC-DMX complies with the regulations shown in the table below.
STANDARD | TITLE |
---|---|
EN 55015 | Limits and methods of measurement of radio disturbance |
characteristics of electrical lighting and similar equipment
EN 61547| Equipment for general lighting purposes – EMC immunity
requirement
EN 61347-1| Lamp Controlgear – Part 1: General and safety requirement
EN 61347-2-13| Lamp controlgear – Part 2-13: Particular requirement for
d.c. or a.c. supplied electronic Controlgear for LED modules
ANSI E1.11| Entertainment Technology – USITT DMX512-A – Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment
and Accessories
ANSI E1.20| Entertainment Technology-RDM-Remote Device Management over
USITT DMX512 Networks
Table 3: Reference standards
- The maximum total output current depends on the operating conditions and ambient temperature of the system. For the correct configuration, check the maximum power that can be delivered in the §Technical Specifications section and in the §Thermal Characterization.
- Protections refer to the control logic of the board.
TECHNICAL SPECIFICATIONS
| Parametri| | Valori
---|---|---|---
INPUT| Nominal Supply Voltage (Vin)| (12, 24, 48) Vdc
Power Supply Range (Vmin ÷ Vmax)| (10,8 ÷ 52,8) Vdc
Efficiency at full load| > 95%
Power consumption in standby mode| < 0,5 W
OUTPUT| Output Voltage| = Vin
Output Current 3 (max)| 4x 0,9 A| 3,6 A (total)
** Rated Power Output| @12 Vdc| 4x 10,8 W| 43,2 W (total)
@24 Vdc| 4x 21,6 W| 86,4 W (total)
@48 Vdc| 4x 43,2 W| 172,8 W (total)
Type of Load| R-L-C
DIMMING| Dimming Curves 4| Linear – Quadratic – Exponential
Dimming Method| Pulse With Modulation (PWM)
PWM Frequency 4| 307 – 667 – 1333 – 2000 – 3400 Hz
Dimming Resolution| 16 bit
Dimming range| (1 ÷ 100)5 %
ENVIRONMENTAL**| Storage Temperature (Tstock_min ÷ Tstock_max)| (-40 ÷
+60) °C
Working ambient temperature (Tamb_min ÷ Tamb_max)3, 6| (-10 ÷ +60) °C
(-10 ÷ +45) °C for currents (750 ÷ 900) mA
Maximum temperature at Tc point| 80 °C
Connector Type| Push-in terminals
Wiring Section| Solid size| 0,2 ÷ 1,5 mm2
Stranded size| 24 ÷ 16 AWG
Stripping| 9 ÷ 10 mm
Protection class| IP20
Casing Material| Plastic
Packaging units (piece/units)| 1pz
Mechanical Dimensions| 186 x 29 x 21 mm
Package Dimensions| 197 x 34 x 29 mm
Weight| 80g
Table 4: Technical specifications
POSITIONING OF THE TC POINT
The figure below shows the positioning of the maximum temperature point (Tc point, highlighted in red) reached by the electronics inside the enclosure. It is located on the front side (Top) near the LED output connector.
Figure 1: Tc point positioning
- These maximum current values can only be applied under conditions of adequate ventilation. For the full range of values, refer to the §Thermal Characterization of the manual.
- The parameters are configured using LightApp©.
- Measured on a linear dimming curve at 3.4 kHz. This value depends on the type of connected load.
- Tamb_max: depends on ventilation conditions.
INSTALLATION
ATTENTION! Installation and maintenance must always be carried out in the
absence of voltage.
Before proceeding with the connection of the device to the power supply, make
sure that the voltage of the power source is disconnected from the system.
The device should only be connected and installed by qualified personnel. All
applicable regulations, legislation, standards, and building codes must be
adhered to. Incorrect installation of the device may cause irreparable damage
to the device and connected loads.
The following paragraphs show the diagrams of the dimmer’s connection to the
remote control, the load and the supply voltage. It is recommended to follow
these steps to install the product safely:
- Load Connection: Connect the LED load positive to the “L” terminal with the “+” symbol, while the LED load negatives to the “L1”, “L2”, “L3” and “L4” terminals with the “-” symbol.
- Remote Control Connection: Connect the DATA+, DATA- and COM data bus signals respectively to the “DMX” terminals with the “D+” “D-” “COM” symbols.
- Power connection: Connect a 12-24-48 Vdc constant voltage SELV power supply (depending on the nameplate data of the LED load) to the “+” and “-” terminals of the DC IN terminal.
LOAD CONNECTION
LINE-4CC-DMX has 4 output channels that can be driven independently (e.g. for
single-color LED spotlights) or depending on the RGB value or white light
temperature (e.g. for RGB, RGB+W and Tunable-White LED modules).
The DMX protocol provides for different configurations called Personality7,
depending on the type of LED load and the light characteristics to be
obtained.
For each Personality there is therefore a dedicated connection diagram,
depending on the type of LED load. LINE-4CC-DMX supports up to 9 Personalities
distributed over 4 connection schemes, shown below.
DIAGRAM FOR WHITE OR SINGLE-COLOR LED LOADS
The following connection diagram (Figure 2) is suitable for the DMX
Personalities §Dimmer and §Macro Dimmer and allows you to drive up to 4 white
or single-color LED loads.
- In the context of the DMX protocol, the term “Personality” refers to a specific set of channels and functions that a DMX device may have. Each Personality defines a different configuration of channels and functions for the device (e.g. one Personality may include channels for controlling light intensity, color, or temperature, while another may only include channels for intensity and color). This allows light operators to select the configuration that best suits their needs.
DIAGRAM FOR TUNABLE-WHITE + TUNABLE-WHITE LED LOADS
This connection diagram is suitable for driving up to 2 Tunable-White LED
loads8, which can be configured using the DMX Personality §Tunable White.
DIAGRAM FOR RGB LED LOADS
Figure 4 shows the connection diagram suitable for driving a single RGB LED
load, configurable through the DMX Personalities §RGB, §M+RGB+S, and §Smart
HSI RGB and RGBW.
- “Tunable-White” refers to the ability of a lighting fixture to vary the color temperature of white independently of its light intensity.
DIAGRAM FOR RGBW LED LOADS
Figure 5 shows the connection diagram indicated to drive a single RGBW LED
load, whose parameters are configurable through the Personality §RGBW,
§M+RGBW+S, §Smart HSI RGB and RGBW
REMOTE CONTROL CONNECTION
LINE-4CC-DMX can be controlled remotely via DMX512-RDM digital bus by means of
a two-wire cable, twisted and shielded, with a nominal impedance of 110 Ω.
Control is done by means of a DMX512-RDM Master that provides commands to
devices in the DMX network and receives response messages from Slave devices
if they support RDM (Remote Device Management) functionality.
To connect LINE-4CC-DMX to the DMX network, simply connect the bus cables to
the terminals of the “DMX” terminal: since no other topologies are possible
other than Bus-wiring, the polarity of the “COM”, “D+” and “D-” signals must
be respected during the connection.
The most commonly used connectors are 3-pole and 5-pole XLR, where one pin is
the cable shield (ground) and 2 pins are used for DMX signal transmission. In
the case of 5-pole XLR, the other 2 pins are reserved for a secondary DMX
balanced line9.
Signal Description| Pin# (3-Pin XLR)| Pin# (5-Pin XLR)|
DMX512 Function
---|---|---|---
Common Reference| 1| 1| Data-Link Common
Primary Data-Link| 2| 2| Data 1-
3| 3| Data 1+
Secondary Data-Link9| –| 4| Data 2-
–| 5| Data 2+
Table 5: Pin out 3-pin and 5-pin XLR connectors
- Optional, refer to chapter §4.8 of ANSI E1.11.
DMX CABLING TOPOLOGIES
The DMX protocol requires a single wiring topology, namely Bus-wiring, shown
as an example in Figure 7.
POWER SUPPLY CONNECTION
LINE-4CC-DMX can be powered by a constant voltage SELV power supply at 12 Vdc,
24 Vdc or 48 Vdc, depending on the operating voltage of the LED load. Once the
load and remote control (DMX bus) are connected, connect the power supply to
the “+” and “-” terminals of the DC IN terminal.
REMOTE CONTROL: DMX512+RDM
The DMX512 protocol (or DMX), is a digital communication standard used
primarily for controlling stage lighting in the entertainment industry and
allows numerous lights and effects to be controlled from a control room.
Recently, it has also been introduced in architectural lighting. The DMX512 is
based on the physical RS-485 protocol: an RS485 industrial line, i.e. a
shielded bipolar cable with a nominal impedance of 110Ω, is therefore used to
connect a DMX512 controller to compatible equipment; data is transmitted in
differential form at 5 V, with a transmission rate of 250 kb/s.
RDM FEATURES AND PARAMETERS
The Remote Device Management (RDM) extension offers a significant improvement
by introducing two-way communication between lighting controllers and
connected compatible RDM devices. It allows devices to be controlled and
communicated in both directions, making it easy to install and configure the
devices and enabling intelligent management from the control console through
the information sent by the RDM devices. Some of the benefits of RDM include:
- Remote access to driver address settings from the command console (or DMX controller)
- Automatic device search: The controller can search the DMX universe for all connected devices and route them automatically
- Status communication, faults, temperature, etc.: RDM devices can send information about their operating status and any faults to the console
LINE-4CC-DMX natively supports the RDM functionality of the DMX protocol with the following commands.
Std.| RDM Parameter ID| Value| Required| Supported|
Get/Set
---|---|---|---|---|---
E1.20| DISC_UNIQUE_BRANCH| 0x0001| ✔| ✔| –
DISC_MUTE| 0x0002| ✔| ✔| –
DISC_UN_MUTE| 0x0003| ✔| ✔| –
SUPPORTED_PARAMETERS| 0x0050| ✔| ✔| G
PARAMETER_DESCRIPTION| 0x0051| ✔| ✔| G
DEVICE_INFO| 0x0060| ✔| ✔| G
PRODUCT_DETAIL_ID_LIST| 0x0070| –| ✔| G
DEVICE_MODEL_DESCRIPTION| 0x0080| –| ✔| G
MANUFACTURER_LABEL| 0x0081| –| ✔| G
DEVICE LABEL| 0x0082| –| ✔| G+S
SOFTWARE_VERSION_LABEL| 0x00C0| ✔| ✔| G
BOOT_SOFWARE_VERSION_ID| 0x00C1| –| ✔| G
BOOT_SOFWARE_VERSION_LABEL| 0x00C2| –| ✔| G
DMX_PERSONALITY| 0x00E0| –| ✔| G+S
DMX_PERSONALITY_DECRIPTION| 0x00E1| –| ✔| G
DMX_START_ADDRESS| 0x00F0| ✔| ✔| G+S
SLOT_INFO| 0x0120| –| ✔| G
SLOT_DESCRIPTION| 0x0121| –| ✔| G
DEFAULT_SLOT_VALUE| 0x0122| –| ✔| G
DEVICE_HOURS| 0x0400| –| ✔| G+S
LAMP_ON_MODE| 0x0404| –| ✔| G+S
DEVICE_POWER_CYCLES| 0x0405| –| ✔| G10
IDENTIFY_DEVICE| 0x1000| ✔| ✔| G+S
E1.37-1| DIMMER_INFO| 0x0340| –| ✔| G
MINIMUM_LEVEL| 0x0341| –| ✔| G+S
MAXIMUM_LEVEL| 0x0342| –| ✔| G+S
CURVE| 0x0343| –| ✔| G+S
CURVE_DESCRIPTION| 0x0344| –| ✔| G
MODULATION_FREQUENCY| 0x0347| –| ✔| G+S
MODULATION_FREQUENCY_DESCRIPTION| 0x0348| –| ✔| G
Table 6: RDM Parameters
- For this model, “Set” mode is not supported.
CHANNEL MAPPING: DMX PERSONALITIES
The DMX protocol provides for different configurations called Personalities,
depending on the light characteristics to be obtained through the LED module
connected to the outputs.
Each Personality is composed of a defined number of 8-bit channels, whose
values can be set in the range (0 ÷ 255), each of which represents a light
characteristic (e.g. brightness, color, saturation, etc.) to be modulated on
the LED load.
DIMMER
The Personality “Dimmer” allows you to adjust the light intensity for each
channel independently. For the permissible load type and the corresponding
connection diagram, refer to the paragraph §Diagram for White or Single-Color
LED Loads.
MACRO DIMMER
The Personality “Macro Dimmer” allows a single intensity adjustment for all 5
channels. The connection diagram and the type of LED load that can be used
with this configuration can be found in the paragraph §Diagram for White or
Single-Color LED Loads.
TUNABLE WHITE
With Personality “Tunable White”, the intensity and temperature values are
adjusted via two independent DMX channels. The connection diagram and the type
of LED load allowed for this Personality can be found in the paragraph
§Diagram for Tunable-White + Tunable-White LED Loads.
RGB
Through the Personality “RGB” it is possible to adjust the intensity of the
Red-Green-Blue primary colors through three independent DMX channels. For the
permissible load type and connection diagram, refer to the paragraph §Diagram
for RGB LED Load.
M+RGB+S
The Personality “M+RGB+S” has 5 DMX channels, one of which is for adjusting
the light intensity (Master dimmer), 3 channels for adjusting the three
primary colors Red-Green-Blue and one channel for adjusting the Strobe effect.
The permissible load type and connection diagram can be found in the paragraph
§Diagram for RGB LED Load.
RGBW
Similar to the “RGB” Personality, the “RGBW” allows the adjustment of the
intensity of the Red-Green-Blue primary colors through three independent DMX
channels and in addition the adjustment of the white light on a dedicated DMX
channel. This configuration can be used with an RGBW LED load, the connection
diagram of which is defined in the paragraph §Diagram for RGBW LED Load.
M+RGBW+S
The Personality M+RGBW+S has 6 DMX channels, one of which is for adjusting the
light intensity (Master dimmer), 3 channels for adjusting the three primary
colors Red-Green-Blue, one channel for adjusting the amount of white light and
one channel for adjusting the Strobe effect. This Personality can be used with
an RGBW LED load, the connection diagram of which is defined in the paragraph
§Diagram for RGBW LED Load.
SMART HSI RGB AND RGBW
The Personality “Smart HSI RGB” and “Smart HSI RGBW” allow, by means of 6 DMX
channels, the adjustment of the light intensity (Master dimmer), the
correction of the color temperature, the Hue value (Hue), the timing of the
Hue Rotation Rainbow time, the Saturation (Saturation) and the adjustment of
the Strobe effect. The connection diagrams and LED loads that can be used with
these configurations can be found in the paragraphs §Diagram for RGB LED Load
(for “Smart HSI RGB”) and §Diagram for RGBW LED Load (for “Smart HSI RGBW”).
FLICKER PERFORMANCE
LINE-4CC-DMX, thanks to the dimming frequency of 3.4kHz, allows to reduce the
phenomenon of flickering (Flicker).
Depending on eye sensitivity and the type of activity, flickering can affect a
person’s well-being even if the fluctuations in luminance are beyond the
threshold perceptible to the human eye.
The graph shows the phenomenon of flickering as a function of frequency,
measured over the entire dimming range.
The reported results highlight the low-risk zone (yellow) and the no-
observable zone (green), defined by the IEEE 1789-2015 standard11.
THERMAL CHARACTERIZATION
Figure 10 shows the maximum output current values that can be provided by the LINE-4CC-DMX as a function of the operating temperature12 (or ambient temperature, TA) of the work, summarized below:
- TA = (-10 ÷ +60) °C ⇢ IOUT-CH ≤ 0.9 A
These maximum current values can only be applied under suitable ventilation conditions.
DIMMING CURVES
Figure 11 shows the dimming curves supported by the LINE-4CC-DMX dimmer. Curve selection can be done using the Dalcnet LightApp© (see §Control Settings section of this manual).
MECHANICAL DIMENSIONS
Figure Figure 12 details the mechanical measurements and the overall dimensions [mm] of the outer casing.
- Institute of Electrical and Electronics Engineers (IEEE). IEEE std 1789: Recommended Practices for Current Modulation in High-Brightness LEDs to Mitigate Spectator Health Risks.
- In the event that the product is installed inside an electrical panel and/or junction box, TA refers to the temperature inside the panel/box.
TECHNICAL NOTES
INSTALLATION
WARNING! Installation and maintenance should always be carried out in the
absence of DC voltage.
Before proceeding with the installation, adjustment and connection of the
device to the power supply, make sure that the voltage is disconnected from
the system.
The device should only be connected and installed by qualified personnel. All
applicable regulations, legislation, standards, and building codes in force in
the respective countries must be adhered to. Incorrect installation of the
device may cause irreparable damage to the device and connected loads.
Maintenance must only be carried out by qualified personnel in compliance with
current regulations.
The product must be installed inside an electrical panel and/or junction box
that is protected against overvoltage.
The external power supply must be protected. The product must be protected by
a properly sized circuit breaker with overcurrent protection.
Keep 230Vac (LV) circuits and non-SELV circuits separate from SELV safety
ultra-low voltage circuits and any product connections. It is absolutely
forbidden to connect, for any reason, directly or indirectly, the 230Vac mains
voltage to the product (BUS terminals included).
The product must be installed in a vertical or horizontal position, i.e. with
the faceplate/label/top cover facing up or vertically. No other positions are
allowed. The bottom position, i.e. with the faceplate/label/top cover facing
downwards, is not allowed.
During installation, it is recommended to reserve adequate space around the
device to facilitate its accessibility in case of future maintenance or
updates (e.g. via smartphone, NFC).
Use in thermally harsh environments may limit the output power of the product.
For devices embedded within luminaires, the TA ambient temperature range is a
guideline to be carefully observed for the optimal operating environment.
However, the integration of the device within the luminaire must always ensure
proper thermal management (e.g. correct mounting of the device, proper
ventilation, etc.) so that the temperature at the TC point does not exceed its
maximum limit under any circumstances. Proper operation and durability are
only guaranteed if the maximum temperature of the TC point is not exceeded
under the conditions of use.
POWER AND LOAD
The device must be powered only with SELV type power supplies with limited
current at constant voltage, short-circuit protection and suitably sized power
according to the specifications indicated in the product data sheet. No other
types of power supply are permitted.
Size the power of the power supply with reference to the load connected to the
device. If the power supply is oversized compared to the maximum current
drawn, insert an overcurrent protection between the power supply and the
device.
Connecting to an unsuitable power supply may cause the device to operate
outside of the specified design limits, voiding its warranty.
In the case of power supplies equipped with earth terminals, it is mandatory
to connect ALL the protection earth points (PE= Protection Earth) to a state-
of-the-art and certified earthing system.
The power cables of the device must be correctly sized with reference to the
connected load and must be isolated from any wiring or equal to non-SELV
voltage. It is recommended not to exceed 10m of connection between the power
source and the product. Use double-insulated cables. If you want to use
connection cables between the power source and the product longer than 10m,
the installer must ensure the correct operation of the system. In any case,
the connection between the power supply and the product must not exceed 30m.
The device has been designed to work with LED loads only. Connecting and
powering unsuitable loads may cause the device to operate outside of the
specified design limits, voiding its warranty. In general, the operating
conditions of the device should never exceed the specifications indicated in
the product data sheet.
Observe the intended polarity between the LED module and the device. Any
polarity reversal results in no light emission and can often damage the LED
modules.
It is recommended that the connection cables between the product and the LED
module be less than 3m long. Cables must be properly sized and should be
insulated from any non-SELV wiring or parts. It is recommended to use double-
insulated cables. If you want to use connection cables between the product and
the LED module longer than 3m, the installer must ensure the correct operation
of the system. In any case, the connection between the product and the LED
module must not exceed 30m.
It is not allowed to connect different types of loads in the same output
channel.
REMOTE CONTROL
The length and type of cables connecting to the buses must comply with the
specifications of the respective protocols and current regulations. They must
be isolated from any non-SELV wiring or live parts. It is recommended to use
double-insulated cables.
All devices and control signals connected to the buses must be of the SELV
type (the connected devices must be SELV or otherwise provide a SELV signal).
NFC (NEAR FIELD COMMUNICATION) WARNINGS
The NFC antenna is located inside the device, the contact surface of which is
indicated with the symbol Position your smartphone so that its NFC antenna is
in contact with the symbol on the device.
The location of the NFC sensor on the smartphone is dependent on the make and
model of the smartphone itself. Therefore, it is recommended to refer to your
smartphone’s manual or the manufacturer’s website to accurately determine
where the NFC sensor is located. In most cases, the NFC reader is located on
the back side near the top of the smartphone.
NFC technology works optimally with non-metallic materials. Therefore, it is
not recommended to place the device near metal objects or reflective surfaces
when using NFC.
For reliable communication, make sure that the contact surface is not covered
or that it is free of metal objects, wiring, or other electronic devices. Any
impediments could affect the quality of communication.
NFC technology works at a short distance, generally within a few centimetres.
Make sure your device and smartphone are close enough to allow communication.
During firmware update and configuration, you should maintain stable contact
(possibly without movement) between your smartphone and the device for the
entire duration of the process (typically between 3 and 60 seconds). This
ensures that the update goes smoothly and that the device is ready to use
after the process is complete.
LEGAL NOTES
TERMS OF USE
Dalcnet Srl (hereinafter referred to as “the Company”) reserves the right to
make changes to this device, in whole or in part, without prior notice to the
customer. Such changes may affect technical aspects, functionality, design, or
any other element of the device. The company is not required to notify you of
such changes and that your continued use of the device will constitute your
acceptance of the changes.
The company is committed to ensuring that any changes do not compromise the
essential functionality of the device and that they comply with applicable
laws and regulations. In the event of substantial changes, the company
undertakes to provide clear and timely information on the same.
The customer is advised to periodically consult the
www.dalcnet.com website or other official sources to
check for any updates or changes to the device.
SYMBOLS
| All products are manufactured in compliance with European
Regulations, as reported in the Declaration of Conformity.
---|---
| Independent Power Supply Unit: Lamp power supply unit, consisting
of one or more separate elements, designed so that they can be mounted
separately on the outside of a luminaire, with protection in accordance with
the marking and without the use of additional enclosures.
SELV| “Very Low Safety Voltage” in a circuit isolated from the mains
supply by insulation not less than that between the primary and secondary
circuits of a safety isolation transformer according to IEC 61558-2-6.
**| At the end of its useful life, the product described in this data sheet
is classified as waste from electronic equipment and cannot be disposed of as
unsorted municipal solid waste.
Warning!** Improper disposal of the product may cause serious harm to the
environment and human health. For proper disposal, inquire about the
collection and treatment methods provided by the local authorities.
LIGHTAPP
LightApp© is the official Dalcnet application through which it is possible to
configure, in addition to the functions of the LINE-4CC-DMX, also all the
different Dalcnet products equipped with NFC technology.
Dalcnet LightApp© can be downloaded free of charge from the Apple App Store
and Google Play Store.
START-UP AND FIRST INSTALLATION
START SCREEN – CONFIGURE
SETTINGS
On this screen, the app waits for the device parameters to be read.
To read the parameters, simply bring the back of the smartphone close to the
device’s label. The read-sensitive zone of the smartphone may vary depending
on the model.
Once the connection is established, a quick loading screen will appear. You
must remain in position with your smartphone until the parameters are fully
loaded.
iOS variant: To read the parameters, you need to press the SCAN button at the
top right. A pop-up will appear indicating when your smartphone is ready to
scan. Move the smartphone closer to the device and remain in place until the
parameters are fully loaded.
On the Settings page, you can:
- Setting the language of the app (Italian or English)
- View the app version
- Enable password saving on your smartphone
- Setting the Password for Writing Parameters
- View your saved passwords
- View the references of the distribution company (Dalcnet Srl)
FIRMWARE
On the firmware page, you can update the firmware of your device.
The requested file must be of type .bin.
Once the file has been uploaded, simply follow the on-screen instructions.
ATTENTION:
- The upload procedure is irrevocable. Once the upload has started, it will not be possible to pause it.
- If the procedure is interrupted, the firmware will be corrupted and you will need to repeat the loading procedure.
- At the end of the firmware load, all previously set parameters will be reset to factory defaults.
If the update is successful and the loaded version is different from the previous one, the device will flash 10 times on the connected load.
LOADING PARAMETERS
IMPORTANT: The parameters must be written when the device is switched OFF
(without input power).
READ
With the app in READ mode, the smartphone will scan the device and show its
current configuration on the screen.
WRITE
In WRITE mode, the smartphone will write the parameter configuration set on
the screen to the device.
In normal mode (Write All switched OFF) the app writes only the parameters
that have changed since the previous read. In this mode, the write will only
be successful if the serial number of the device matches the one previously
read.
In Write All mode, all parameters are written. In this mode, the write will
only be successful if the device model matches the one previously read.
It is recommended to activate the Write All mode only when you need to
replicate the same configuration on many examples of the same model.
WRITE PROTECTION
By means of the padlock button it is possible to set a lock when writing
parameters. A screen will appear for entering a 4-character password. Once
this password has been written into the device, all subsequent parameter
changes can only be made if the correct password is written on the app’s
Settings page.
To remove the password lock, simply press the lock key and leave the Password
field blank.
WRITE ERROR
After writing the parameters, if the load connected to the device flashes
continuously at a frequency of 2 times per second when it is turned ON again,
it means that the writing was not successful. Therefore, you will need to
perform the following steps:
- Turn OFF the device.
- Perform a parameter rewrite.
- Wait for the write to be successful or for no error messages to appear.
- Turn the device back ON.
If that doesn’t work, you can perform a factory reset by quickly turning the device OFF and ON 6 times.
PRODUCT INFORMATION
On the Product Information screen, you can view a variety of information about
the product you are about to configure.
Product Name: User-settable field for easy identification (e.g. Office,
Meeting Room, Lobby, etc.). By default, the product name is the same as the
Model field.
Model: the model of the device (non-editable field).
Serial Number: uniquely identifies the device (non-editable field).
Firmware Version: identifies the firmware version currently loaded on the
device (non-editable field).
CONTROL SETTINGS
On the Control Settings screen, you can configure the different parameters for the driver’s operation mode.
- PWM Frequency: Sets the frequency13 of the PWM modulation of the output.
- Dimming Curve: Sets the adjustment curve of the device for operation with the local control. For details on the different curves that can be set, see the §Dimming Curves of this manual.
- Minimum Level: sets the minimum level of light intensity that can be reached via DMX remote control.
- Maximum Level: sets the maximum level of light intensity that can be reached via DMX remote control.
- Control Type: allows you to select the DMX Control Map (see next paragraph).
- In the case of applications under severe thermal conditions, it is advisable to lower the PWM frequency to a minimum (307 Hz).
CONTROL TYPES
Within the “Control Type” configuration you can select the DMX512+RDM Channel Maps available for LINE-4CC-DMX:
- Macro Dimmer
- Tunable White
- Smart HSI RGB and RGBW
- RGB
- RGBW
- M+RGB+S
- M+RGBW+S
- Dimmer
The parameters that can be set for each type of control are shown in the following paragraphs.
DMX ADDRESSING
For each type of control, the DMX address of the device can be defined within the range (0 ÷ 512).
POWER-ON SETTINGS
Depending on the type of control selected (“Smart HSI-RGB” in the example
image) for each output channel it is possible to set the initial switch-on
level: during power-up and in the absence of the DMX signal, the device will
bring the outputs to the levels set in this section.
It is also possible to set the memorization of the last level available during
the shutdown phase (e.g. in case of power failure), by selecting the “Last
Level” option: in this case, during the switch-on and in the absence of the
DMX signal, the device will bring the outputs to the levels stored during the
shutdown phase.
For more information on output channel configurations and levels, refer to the
“DMX512-RDM Channel Maps” section of this manual.
DALCNET S.r.l.
36077 Altavilla Vicentina (VI) – Italy Via Lago di Garda, 22
Tel. +39 0444 1836680
www.dalcnet.com
info@dalcnet.com