DALC NET LINE-5CV-DMX Voltage Output For Strip LED and LED Module
Specifications:
- DC Voltage Range: 12-24-48 Vdc
- Output Voltage: 12 Vdc, 24 Vdc, 48 Vdc
- Supply Current: Max 12A
- Output Current: 5 x max 5A, max 12A Total
- Nominal Power: 60W, 144W Total; 120W, 288W Total; 240W, 576W Total
- Power Loss in Standby Mode: < 0.5W
- Type of Loads: Resistive and DC/DC Converter
- Dimming Curves: Configurable via LIGHTAPP
- Dimming Method: Pulse Width Modulation (PWM)
- PWM Frequency: Configurable via LIGHTAPP
- PWM Resolution: 16bit
- Storage Temperature: N/A
- Working Ambient Temperature: Check operating conditions
- Type of Connector: Morsetti Push-In
- Wiring Section: Solid Size and Stranded Size
- Wire Strip Length: N/A
- IP Protection Grade: N/A
- Casing Material: Plastica 1pz
- Packaging Units: 80g
- Mechanical Dimensions: 186 x 29 x 21 mm, Packaging Dimensions: 197 x 34 x 29 mm
- Weight: 80g
Product Usage Instructions
Configuration via Dalcnet LightApp:
The LINE-5CV-DMX can be configured using the Dalcnet LightApp mobile
application. Adjust parameters such as dimming frequency,dimming curve,
maximum and minimum brightness levels, etc. The LightApp is available for
download from the Apple App Store and Google Play Store.
Installation:
Refer to the wiring diagram provided in the manual for proper installation.
Ensure correct connections for the desired setup.
Setting Parameters:
Use the LightApp or RDM to set parameters like PWM Frequency,Adjustment Curve,
Power On Levels, and DMX Personality.
Operating Instructions:
- Soft On/Off Functionality: Enables gradual power transitions for smooth operation.
- Soft Brightness Dimming: Allows for gentle brightness adjustments.
- Short-Circuit Protection: Protects LED outputs from damage in case of a short circuit.
- Opto-Isolated DMX Input: Ensures safe and reliable DMX signal reception.
- Extended Temperature Range: Operates within a wide temperature range for versatile use.
- Functional Test: Perform a 100% functional test before full operation to ensure proper functionality.
FAQ:
Q: Where can I find the most up-to-date manual?
A: For the latest manual version, visit
www.dalcnet.com or scan the QR code on your device.
FEATURES
- DIMMER LED
- Power Supply: 12-24-48 Vdc
- Voltage Output for strip LED and LED module
- WHITE, MONOCOLOR, DYNAMIC WHITE, RGB, RGB+W, RGB+WW and RGB+TW Light Control
- BUS command:: DMX512-A+RDM
- Device configuration using Dalcnet LightApp mobile application
- Uscite in tensione costante per carichi R
- PWM modulation from 300 to 4000 Hz
- Parameters that can be set from APP and via RDM:
- PWM Frequency
- Adjustment curve
- Power On Levels
- Personality DMX
- Indication of operating hours and ignition cycles
- Short-circuit protection on LED outputs
- Opto-Isolated DMX Input
- Soft on/off
- Soft brightness dimming
- Extended temperature range
- 100% Functional test
PRODUCT DESCRIPTION
LINE-5CV-DMX is a 5-channel output LED dimmer, which can be controlled by
means of a DMX BUS control.
The LED dimmer is suitable for driving loads such as StripLEDs and LED
modules, White, Single-color, Dynamic White, RGB, RGB+W, RGB+WW and RGB+TW at
constant voltage. A 12-24-48 Vdc power supply can be connected.
The maximum output current is 12A. The dimmer LED has the following
protections: short-circuit protection on the LED outputs, over-power
protection, reverse polarity protection, and input fuse protection.
Through the Dalcnet LightApp mobile application, it is possible to configure
multiple parameters of the LINE-5CV-DMX such as dimming frequency, dimming
curve, max and min brightness level, etc.
LightApp can be downloaded free of charge from the Apple App Store and Google
Play Store.
⇢ For the most up-to-date manual, please visit our website: www.dalcnet.com or the QR Code directly on your device.
PRODUCT CODE
CODE| POWER SUPPLY| OUTPUT LED| N° OF CHANNEL| BUS
COMMAND| APP CONFIG
---|---|---|---|---|---
LINE-5CV-DMX| 12-24-48 VDC| 5 x 5A (max 12A)1| 5| DMX512-RDM| APP: LIGHT
APP
PROTECTIONS
OVP | Over-voltage protection2 | ✔ |
---|---|---|
RVP | Reverse polarity protection2 | ✔ |
IFP | Protection with input fuse2 | ✔ |
SCP | Short circuit protection | ✔ |
REFERENCE STANDARDS
EN 55015| Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
---|---
EN 61547| Equipment for general lighting purposes – EMC immunity
requirement
EN 61347-1| Lamp Controlgear – Part 1: General and safety requirement
EN 61347-2-13| Lamp Controlgear – Part 2-13: Particular requirement for
d.c. or a.c. supplied electronic Controlgear for LED modules
ANSI E1.11| Entertainment Technology – USITT DMX512-A – Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment
and Accessories
ANSI E1.20| Entertainment Technology-RDM-Remote Device Management over
USITT DMX512 Networks
TECHNICAL SPECIFICATIONS
LINE 5CV DMX | |
---|---|
DC voltage range | Min: 10,8Vdc – Max: 52,8Vdc |
Output voltage | =Vin |
Supply current | Max 12A |
Output current 3 | 5x max 5A |
Nominal power
| 12 Vdc| 60W| 144W Tot.
24 Vdc| 120W| 288W Tot
48 Vdc| 240W| 576W Tot.
Power loss in standby mode| < 0,5W
Type of loads 4| R
Dimming curves 5| Linear – Quadratic – Exponential
Dimming method| Pulse Width Modulation “PWM”
PWM Frequency 5| 307 – 667 – 1333 – 2000 – 4000 Hz
PWM Resolution| 16bit
Storage Temperature| Min: -40°C – Max: 60°C
Working ambient temperature, Ta 3| Min: -10°C – Max: 60°C
Type of connector| Morsetti Push-In
Wiring section| Solid Size| 0,2 ÷ 1,5 mm2 / 24 ÷ 16 AWG
Stranded Size
Wire strip length| 9 ÷ 10 mm
IP protection grade| IP20
Casing Material| Plastica
Packaging units (pieces/units)| 1pz
Mechanical dimensions| 186 x 29 x 21 mm
Packaging dimensions| 197 x 34 x 29 mm
Weight| 80g
WIRING DIAGRAM
Follow the steps below for product installation as shown in the connection diagram:
- Load connection: connect the LED load positive to terminal “L” with the “+” symbol, instead of the LED load negatives to terminals “L1”, “L2”, “L3”, “L4” and “L5” with the “-” symbol.
- DMX-RDM BUS connection: connect the DATA+, DATA- and COM signal respectively to the “DMX” terminals with the “D+” “D-” “COM” symbols. Be sure not to connect live parts to the “INPUT” terminals.
- Supply connection: connect a 12-24-48 Vdc constant voltage SELV power supply (depending on the technical characteristics of the LED load) to the DC IN terminal with the “+” and “- ” symbols.
Make sure that you are not using a power supply with a constant current output and check that the polarity of the cables is correct.
CONNECTION DIAGRAM: PERSONALITY DIMMER & MACRO DIMMER UP TO 5 WHITE OR MONOCHROME LOADS
CONNECTION DIAGRAM:
PERSONALITY DIM TO WARM & DYNAMIC WHITE UP TO 2 LOADS DIM TO WARM OR
DYNAMIC WHITE
FLICKER PERFORMANCE
Thanks to its 4kHz dimming frequency, the LINE-5CV-DMX effectively reduces the
occurrence of the Flicker phenomenon. Depending on an individual’s sensitivity
and the nature of their activities, flickering can impact one’s well-being,
even if the changes in luminance are beyond the threshold detectable by the
human eye.
The graph shows the phenomenon of Flickering in function at the frequency,
measured throughout the dimming range.
The results show the low-risk zone (yellow) and the no-effect zone (green).
Defined by IEEE 1789-20156
DIMMING CURVE
DMX+RDM BUS OPERATION
WITH THE DMX+RDM “SLAVE” BUS MODE, THE OUTPUTS ARE MANAGED VIA AN EXTERNAL DMX CONTROL.
REFERENCE STANDARDS FOR THE DMX512+RDM BUS
ANSI E1.11| Entertainment Technology – USITT DMX512-A – Asynchronous
Serial Digital Data Transmission Standard for Controlling Lighting Equipment
and Accessories
---|---
ANSI E1.20| Entertainment Technology-RDM-Remote Device Management over
USITT DMX512 Networks
PIN OUT 3 AND 5 PIN XLR CONNECTORS
USE | 3-PIN XLR Pin # | 5-PIN XLR Pin # | DMX512 Function |
---|---|---|---|
Common Reference | 1 | 1 | Data Link Common |
Primary Data Link | 2 | 2 | Data 1- |
3 | 3 | Data 1+ |
Secondary Data Link
(Optional – see clause 4.8 of ANSI E1.11)
| | 4| Data 2-
| 5| Data 2+
CHANNELS MAP DMX512-RDM
RDM SETTINGS
DMX START ADDRESS: DEVICE DMX CHANNEL SETTING.
Within the DMX START ADDRESS configuration, you can configure the DMX channel
of the device.
DMX PERSONALITY: DEVICE MAP SETTINGS
Within the DMX PERSONALITY configuration it is possible to select the various
maps of the LINE 5CV DMX, including:
- MACRO DIMMER
- DIM TO WARM
- TUNABEL WHITE
- SMART HSI RGB
- SMART HSI RGBW
- RGB
- RGBW
- MRGB+S
- MRGBW+S
- DIMMER
- SMART HSI RGBW+TW
DEVICE STATE: DEVICE OPERATION STATUS SETTINGS
Within the DEVICE STATE menu there is information on the operating hours and
the on/off cycles of the device.
These parameters are read-only and cannot be edited.
LAMP MENU : DEVICE POWER-ON STATUS SETTINGS
Within the LAMP MENU’ menu it is possible to define “LAMP ON MODE”, i.e. the
status of the outputs when the device is switched on, whether it is 100% On or
Off.
This function is only enabled in the absence of the DMX signal.
DIMMER MENU: DIMMING CURVE AND FREQUENCY SETTINGS OF THE DEVICE
Within the DIMMER MENU you can select the Linear, Quadratic or Exponential
dimming curve and the dimming frequency 307, 667, 1333, 2000 or 4000 Hz.
RDM COMMANDS
REQUESTED PARAMETERS
DISC_UNIQUE_BRANCH| ✔
DISC_MUTE| ✔
DISC_UN_MUTE| ✔
SUPPORTED_PARAMETERS| ✔
PARAMETER_DESCRIPTION| ✔
DEVICE_INVO| ✔
DMX_START_ADDRESS| ✔
IDENTIFY_DEVICE| ✔
SUPPORTED PARAMETERS
PRODUCT_DETAIL_ID_LIST| ✔
DEVICE_MODEL_DESCRIPTION| ✔
MANUFACTURER_LABEL| ✔
DEVICE LABEL| ✔
BOOT_SOFWARE_VERSION_ID| ✔
BOOT_SOFWARE_VERSION_LABEL| ✔
DMX_PERSONALITY| ✔
DMX_PERSONALITY_DECRIPTION| ✔
SLOT_INFO| ✔
SLOT_DESCRIPTION| ✔
DEFAULT_SLOT_VALUE| ✔
DEVICE_HOURS| ✔
LAMP_ON_MODE| ✔
DIMMER_INFO| ✔
CURVE| ✔
CURVE_DESCRIPTION| ✔
MODULATION_FREQUENCY| ✔
MODULATION_FREQUENCY_DESCRIPTION| ✔
MECHANICAL DIMENSIONS
TECHNICAL NOTE
iNSTALLATION
-
CAUTION: The product may only be connected and installed by a qualified electrician. All applicable regulations, legislation, and building codes must be observed. Incorrect installation of the product can cause irreparable damage to the product and the connected LEDs.
Use caution when connecting LEDs. Polarity reversal results in no light output and can often damage the LEDs. -
Maintenance must only be carried out by qualified personnel in compliance with current regulations.
The product is designed and intended to operate LED loads only. Powering non- LED loads may push the product outside its specified design limits and is, therefore, not covered by any warranty.
Operating conditions of the product may never exceed the specifications as per the product datasheet. -
The product must be installed inside a switchgear/controlgear cabinet and/or junction box protection against overvoltage.
-
The product must be installed in a vertical or horizontal position with the label/top cover facing upwards or vertically. Other positions are not permitted. The bottom position is not permitted (label/top cover facing down).
-
Keep separated 230Vac (LV) circuits and not SELV circuit from safety extra low voltage (SELV) circuit and from any connection with this product. It is absolutely forbitten to connect, for any reason whatsoever, directly or indirectly, the 230Vac mains voltage to the product (terminal block of BUS included).
-
The product must be dissipated correctly.
-
The use of the product in harsh environments could limit the output power.
-
For built-in components inside luminaires, the ta ambient temperature range is a guideline given for the optimum operating environment. However, integrator must always ensure proper thermal management (i.e. correct mounting of the device, air flow etc.) so that the tc point temperature does not exceed the tc maximum limit in any circumstance. Reliable operation and lifetime is only guaranteed if the maximum tc point temperature is not exceeded under the conditions of use.
POWER SUPPLY
-
Only use SELV power supplies with limited current for device power supply, short circuit protection and the power must be dimensioned correctly.
In the case of power supplies equipped with ground terminals, it is mandatory to connect ALL protective ground points (PE= Protection Earth) to a properly and certified protection earth. -
The connection cables between the very low voltage power source and the product must be properly dimensioned and must be insulated from any wiring or part at non-SELV voltage. Use double insulated cables.
-
Dimension the power of the power supply in relation to the load connected to the device. In case the power supply is oversized compared to the maximum absorbed current, insert a protection against over-current between the power supply and the device.
COMMANDS:
- The length of the cables connecting between the local commands (N.O. Push button or other) and the product must be less than 10m. The cables must be properly dimensioned and must be insulated from any non-SELV wiring or voltage. It is recommended to use double insulated cables, if deemed appropriate also shielded.
- All devices and control signals connected to the buses (DMX512 or other) must be of the SELV type (the connected devices must be SELV or in any case provide a SELV signal).
OUTPUTS:
- It is recommended that the length of the connection cables between the product and the LED module is less than 3m. Cables must be properly sized and should be insulated from any non-SELV wiring or parts. It is recommended to use double-insulated cables. If you want to use connection cables between the product and the LED module longer than 3m, the installer must ensure the correct operation of the system. In any case, the connection between the product and the LED module must not exceed 30m.
SYMBOLOGIES
|
All products are manufactured in compliance with European Directives, as reported in the EU Conformity Declaration.
---|---
| Independent lamp Controlgear: lamp controlgear consisting of one or more
separate elements so designed that it can be mounted separately outside a
luminaire, with protection according to the marking of the lamp controlgear
and without any additional enclosure
****| “Safety Extra Low Voltage” in a circuit which is isolated from the
mains supply by insulation not less than that between the primary and
secondary circuits of a safety isolating transformer according to IEC
61558-2-6.
| At the end of its useful life the product described in this datasheet is
classified as waste from electronic equipment, and cannot be disposed together
with the municipal undifferentiated solid waste.
Warning! Incorrect disposal of this product may cause serious damage to the environment and human health. Please be informed about the correct disposal procedures for waste collecting and processing provided by local authorities.
LIGHTAPP
START-UP AND FIRST INSTALLATION
STARTUP SCREEN
On this screen, the app waits for the device parameters to be read.
To read the parameters, simply bring the back of the smartphone close to the
device’s label. The read-sensitive zone of the smartphone may vary depending
on the model.
Once the connection is established, a quick loading screen will appear. You
must remain in position with your smartphone until the parameters are fully
loaded.
iOS variant: To read the parameters, you need to press the SCAN button at the top right. A pop-up will appear indicating when your smartphone is ready to scan. Move the smartphone closer to the device and remain in place until the parameters are fully loaded.
SETTINGS AND FIRMWARE LOADING SCREENS
SETTINGS
On the settings page you can set:
- App language
- Password: To be used for writing parameters.
FIRMWARE
On the firmware page, you can update the firmware of the device.
The requested file must be of type *.bin.
Once the file is uploaded, follow the on-screen instructions.
ATTENTION:
- Once the procedure has begun, it is irrevocable and it is not possible to pause it.
- In case of interruption the firmware would be corrupted. In this case the device will need to repeat the loading procedure.
- At the end of the firmware loading, all previously set parameters will be reset to factory values.
If the update is successful and the loaded version is different from the previous one, the device will make 10 flashes
LOADING PARAMETERS
IMPORTANT: The writing of the parameters must be done with the device off (without input power).
READ
With the app in READ mode, the smartphone will scan the device and show its
current configuration on the screen.
WRITE
With the app in WRITE mode, the smartphone will write the configuration of the
parameters set on the screen inside the device.
Write all
In normal mode (Write All Off) the app writes only the parameters that have
changed since the previous reading. In this mode, writing will only be
successful if the serial number of the device matches the one previously read.
In Write All mode, all parameters are written. In this mode, writing will be
successful only if the device model matches the one previously read.
It is recommended to activate the Write All mode only when you need to
replicate the same configuration on many other devices of the same model.
WRITE PROTECTION
Using the padlock button, you can set a block when writing parameters. A screen for entering a 4-character password will appear. Once this password has been written to the device, all subsequent parameter changes can only be made if the correct password is written to the Settings page of the app.
To remove the password lock, simply press the padlock button and leave the Password field blank.
WRITING ERROR
If, after writing the parameters, when you turn it back on, the device flashes
2 times per second continuously, it means that the writing was not successful.
Therefore, you need to perform the following steps:
- Turn off the device.
- Rewrite the parameters.
- Wait for the script to be successful or for no error messages to appear.
- Turn the device back on.
If it does not work, you can perform a factory reset by quickly turning the device off and on 6 times.
PRODUCT INFORMATION
- Product Name: User-settable field for easy identification. By default, the product name is the same as the Model field.
- Model: An immutable field. Identifies the device model.
- Serial number: This field cannot be edited. Uniquely identifies the specimen.
- Firmware version: field not editable. Identifies the firmware version currently loaded on the device.
IMPOSTAZIONI DI CONTROLLO
- PWM frequency: allows you to set the frequency of PWM modulation of the output.
- NOTE: For applications in harsh thermal conditions, it is advisable to lower the PWM frequency to a minimum (307 Hz)
- Dimming curve: For details, see the Dimming Curves section of the device manual
- Control type: Selection of the control map (see next paragraph).
CONTROL TYPES
Within the “Control Type” configuration it is possible to select the various maps of the LINE-5CV-DMX, including:
- MACRO DIMMER
- DIM TO WARM
- TUNABLE WHITE
- SMART HSI-RGB
- SMART HSI-RGBW
- RGB
- RGBW
- MRGB+S
- MRGBW+S
- DIMMER
- SMART HSI RGBW+TW
DMX ADDRESSING
For each type of control, the DMX address of the device can be defined
within the range (0 ÷ 512).
POWER-ON SETTINGS
- Depending on the type of control selected (“Smart HSI-RGB” in the example image) for each output channel it is possible to set the initial switch-on level: during power-up and in the absence of the DMX signal, the device will bring the outputs to the levels set in this section.
- It is also possible to set the memorization of the last level available during the shutdown phase (e.g. in case of power failure), by selecting the “Last Level” option: in this case, during the switch-on and in the absence of the DMX signal, the device will bring the outputs to the levels stored during the shutdown phase.
- For more information on output channel configurations and levels, refer to the “DMX512-RDM Channel Maps” section of this manual.
DALCNET S.r.l.
36077 Altavilla Vicentina (VI) – Italy
Via Lago di Garda, 22
Tel. +39 0444 1836680
www.dalcnet.com
info@dalcnet.com
Rev. 08/04/2024 – Pag. 18/18
References
- Led dimmer and RGB controller for professional lighting systems
- Led dimmer and RGB controller for professional lighting systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>