DALC NET DIM Converter Casambi Instruction Manual

June 12, 2024
DALC NET

DALC NET DIM Converter Casambi Instruction Manual
Converter Casambi

FEATURES

  • Input DC: 12/24/48 Vdc (Supply Voltage range 10,8Vdc – 52,8Vdc)
  • N°4 Low voltage “Relay Driver” output to command external power relays
  • N°4 Analog output 0-10V / 1-10V to command Power Supplies with DIM Function or Led Driver and Dimming device 0/1-10V
  • Remote Command: CASAMBI APP
  • Local Commands: n° 4 Push Buttons N.O.
  • Conversion from Casambi signal to 0/1-10V command
  • Extended temperature range: min: -25°C .. max: +60°C
  • 100% functional test – 5 Years warranty

→ For the whole and updated Device Manual refer to producer’s website: http://dalcnet.com

PRODUCT CODE DIMMER CONVERTER

CODE Power Supply Output Channel Command
ADC1248-4CH-CASAMBI 12/24/48 V DC 4x 0-10V / 1-10V4x Relay Driver 4 Analog4
Relay Driver CASAMBI APP4x N.O. Push buttons

PROTECTIONS

OTP| Over temperature protection1|
---|---|---
OVP| Over voltage protection2|
UVP| Under voltage protection2|
RVP| Reverse polarity protection2|
IFP| Input fuse protection2|
SCP| Short circuit protection|
CLP| Current limit protection|

TYPE OF PROFILE

Type| I SI Profile I| I Name of prone| Description
---|---|---|---
DIMMER| 4050| DIM CONVERTER| *1(1 Master Dimmer end n4 independent channels.
9mutuneous output control 0/1-10Y & relay dnver
CONVERTER| 111119 I| I CH DRIVER RELAY| NM Channels for ON/OFF control of Ocher Relay outputs only
**

REFRENCE STANDARDS

EN 61347-1 Lamp controlgear – Part 1: General and safety requirements
EN 55015 Limits and methods of measurement of radio disturbance

characteristics of electrical lighting and similar equipment
EN 61547| Equipment for general lighting purposes – EMC immunity requirements

TECHNICAL SPECIFICATION

  FEATURES DIMMER CONVERTER
Supply Voltage “Vin” Min: 10,8 Vdc .. Max: 53,5 Vdc
Analog Output 4 0/1-10V output
Realy Driver Output 4 Relay Driver Output
Output status 1 channel status LED indicate whether a load is On or OFF
Thermal shutdown 150°C3
Storage Temperature Min: -40 .. Max:+60 °C
Ambient Temperature3 Min: -40 .. Max:+60 °C
Protection grade IP10
Wiring Buttons & Bus 1.5 mm2 solid – 1 mm2 stranded – 30/14 AWG
Wiring Power, Out relay driver & Out 0/1-10V 2.5 mm2 solid – 1.5 mm2

stranded – 30/12 AWG
| Mechanical Dimension| 106 x 91 x 62 mm – DIN RAIL 6M
| Packaging Dimension| 156 x 124 x 71 mm
| Weight| 205g
FEATURES RELAY DRIVER OUTPUT|
Output Voltage| =Vin4|
Output Current| Max 500mA per channel5|
FEATURES ANALOG OUTPUT 0/1-10V|
0-10V – Sink or Source Current| 10mA/ch6|
1-10V – Sink or Source Current| 10mA/ch6|

INSTALLATION

Installation

MECHANICAL DIMENSION (without connectors)

DIMENSION

SETUP INSTALLATION

LOCAL COMMAND – Connection and functions of the N.O. push button with and without memory
Buttons

Input Function Output 0/1-10V Driver Relay output
Variation of output 0/1-10V Relay output OFF Relay output ON
IN1 Variation OUT 1
IN2 Variation OUT 2 Single Click

Long Click (>1s)

| : ON / OFF

: Analog output variation 0/1-10V

| Click OFF| Click ON
IN3| Variation OUT 3| Click OFF| Click ON
IN4| Variation OUT 4| | | Click OFF| Click ON

REMARKS: For the control with the Push Buttons N.O. see the documentations in the website: http://www.casambi.com
For the length of the cables see the Technical Note

DIM CONVERTER OUTPUT – Type of output connection.

For each single analog output (0/1-10V) is associated a single Relay Driver output.

  • The analog output L1+,L1- ⇢ “OUT 0/1-10V” ; Is associated with Relay Driver output L1+,L1- ⇢ “OUT DRIVER RELE’ ”
  • The analog output L2+,L2- ⇢ “OUT 0/1-10V” ; Is associated with Relay Driver output L2+,L2- ⇢ “OUT DRIVER RELE’ ”
  • The analog output L3+,L3- ⇢ “OUT 0/1-10V” ; Is associated with Relay Driver output L3+,L3- ⇢ “OUT DRIVER RELE’ ”
  • The analog output L4+,L4- ⇢ “OUT 0/1-10V” ; Is associated with Relay Driver output L4+,L4- ⇢ “OUT DRIVER RELE’ ”
ANALOG OUTPUT 0-10V 1-10V

The 4 analog output are Sink / Source. It is possible to control device with command input both 0-10V that 1-10V. It is possible to control either devices with 0-10V input command, and devices with 1-10V in command.

Example: The four analog output command the power supply with DIM FUNCTION, Led Driver with 0/1-10V command or dimmable devices 0/1-10V, as LED driver Dalcnet.

Example of application

Connection

Thanks to DIM CONVERTER CASAMBI is possible to command the power supplies with DIM Function (with 0/1-10V command) to dim the load connected to it. The command to manage the outputs of DIM CONVERTER could be analog (Push buttons N.O.) or from Casambi command. Moreover, thanks to the low voltage Relay Driver outputs, it is possible to connect the power Relay. The Power Relay allow to control the power lines (230Vac) for switching on/off the power supplies controlled by the associated analog outputs.
Note: The Power Relays are not supplied with DIM CONVERTER CASAMBI. The switching voltage to relay, must be dimensioned to the power supply of Device “DIM CONVERTER CASAMBI”.

TECHNICAL NOTE:

Installation:

  • Installation and maintenance must be performed only by qualified personnel in compliance with current regulations.
  • The product must be installed inside an electrical panel protected against overvoltages.
  • The product must be installed in a vertical or horizontal position with the cover / label upwards or vertically; Other positions are not permitted. It is not permitted to bottom-up position (with the cover / label down).
  • Keep separated the circuits at 230V (LV) and the circuits not SELV from circuits to low voltage (SELV) and from any connection with this product. It is absolutely forbidden to connect, for any reason whatsoever, directly or indirectly, the 230V mains voltage to the bus or to other parts of the circuit.

Power supply:

  • For the power supply use only a SELV power supplies with limited current, short circuit protection and the power must be dimensionedcorrectly. In case of using power supply with ground terminals, all points of the protective earth (PE = Protection Earth) must be connected to a valid and certified protection earth.
  • The connection cables between the power source “low voltage” and the product must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Use double insulated cables.
  • Dimension the power supply for the load connected to the device. If the power supply is oversized compared with the maximum absorbed current, insert a protection against over-current between the power supply and the device.

Command:

  • The length of the connection cables between the local commands (N.O. Push button or other) and the product must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Use double insulated shielded and twisted cables.
  • All the product and the control signal connect at the local command (N.O. Push button or other) must be SELV (the devices connected must be SELV or supply a SELV signal)

Outputs:

  • The length of the connection cables between the product and the LED module must be less than 10m; the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV. Is preferable to use shielded and twisted cables.

WARNING: For optional functionality of the Bluetooth signal, do not put the device into metal or aluminium boxes and do not shield the device.
As any other Bluetooth product, should not be placed in a metal enclosure or next to large metal structures. Metal will effectively block all radio signal which are crucial to the operation of the product.

DALCNET S.r.l, Registered office: Via Lago di Garda, 22 – 36077 Altavilla Vicentina (VI) – Italy
Headquarters: Via Lago di Garda, 22 – 36077 Altavilla Vicentina (VI) – Italy
VAT: IT04023100235 – Tel. +39 0444 1836680 – www.dalcnet.com[email protected]