Fantech RN1 – 4.5 Inline Radon Fan (169 CFM) Instruction Manual
- June 3, 2024
- fantech
Table of Contents
Fantech RN1 – 4.5 Inline Radon Fan (169 CFM)
THIS BOX INCLUDES
- Inline Radon Fan Rn, 1 pc
- Operation and Installation Manual, 1 pc
DO NOT CONNECT POWER SUPPLY until fan is completely installed. Make sure electrical service to the fan is in the locked OFF position.
- These fans have rotating parts and safety precaution should be exercised during installation, operation and maintenance.
- WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS – OBSERVE THE FOLLOWING:
- Use this unit in the manner intended by the manufacturer. If you have any questions, contact your manufacturer’s representative or contact us directly.
- CAUTION: Before installation, servicing or cleaning unit, switch power off at service panel and lock the service disconnection means to prevent power from being switched on accidentally. When the service disconnection means cannot be locked, securely fasten a prominent warning device, such as tag, to the panel.
- Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire- rated construction.
- The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local code authorities.
- When cutting or drilling into wall and ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- WARNING! Check voltage at the fan to see if it corresponds to the motor name plate.
- For radon mitigation use only. DO NOT use to exhaust hazardous or explosive materials and vapors.
- Do not use these fans with any solid state speed control device.
GUARDS MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PERSONNEL OR WITHIN SEVEN (7) FEET OF WORKING LEVEL OR WHEN DEEMED ADVISABLE FOR SAFETY.
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.
DIMENSIONS
Model/Modèle | A | B | C | D |
---|---|---|---|---|
Rn1 | 4 15/32 (114) | 10 (254) | 1 1/4 (32) | 9 1/4 (235) |
Rn2 | 4 15/32 (114) | 10 (254) | 1 1/4 (32) | 9 1/4 (235) |
Rn3 | 5 7/8 (149) | 11 1/2 (292) | 1 1/4 (32) | 9 1/4 (235) |
Dimensions in inches (mm). Dimensions en pouces (mm)
INSTALLATION
The Rn1, Rn2, and Rn3 are designed for use with 3″ and 4″ schedule 40 PVC
pipe, when appropriate LDVI™ coupling is used.
Prior to installation, the suction pipe should be terminated at the exterior
wall. The suction pipe should be installed with slight incline to drain water
from the fan.
Radon fans are to be installed in the vertical orientation ONLY.
DO NOT connect fan directly to building structure
| CFM @ Static Pressure|
---|---|---
| Voltage| Max Amp| Max Watts| Phase| RPM| CFM/Watts| Energy Star| | Max
0.00| 0.20| 0.50| 1.00| 1.50| 2.00
Rn1| 120| 0.17| 19.7| 1| 3100| 7.30| Yes| 160| 130| 80| –| –| –| 0.89
Rn2| 120| 0.48| 58.0| 1| 2700| 2.59| No| 160| 150| 120| 80| 40| –| 1.97
Rn3| 120| 1.20| 141.2| 1| 2700| 2.42| No| 370| 340| 280| 180| 120| 50| 2.36
WIRING DIAGRAM
There are typically three wires to be connected to an electrical fan; Load, Neutral and Ground. Load provides power to the fan, Neutral is for returning current and closing the electrical circuit, and Ground is for an additional path to safely return current to the ground, in case of an accidental electrical short in the fan and/or discharging of fan metal components. Fantech radon fans are permanently connected appliances employing a reinforced polymeric construction. The non-conductive construction functions as a “Double Insulated” protective System (Complies with Standard for Double Insulation Systems for Use in Electrical Equipment, UL 1097), thus eliminating the need for a grounding conductor. All Fantech radon fans are tested and reviewed by Underwriter Laboratories, a 3rd party independent safety governing body, and deemed suitable for outdoor use (Standard for Safety-Electric Fans, UL 507). Please contact Fantech Technical Support if additional information is needed regarding this matter.
WARRANTY
Five (5) Year Warranty
This warranty supersedes all prior warranties
DURING ENTIRE WARRANTY PERIOD:
Fantech will repair or replace any part which has a factory defect in
workmanship or material. Product may need to be returned to the Fantech
factory, together with a copy of the bill of sale and identified with RMA
number.
FOR FACTORY RETURN YOU MUST:
- Have a Return Materials Authorization (RMA) number. This may be obtained by calling Fantech either in the USA at 1.800.747.1762 or in CANADA at 1.800.565.3548. Please have bill of sale available.
- The RMA number must be clearly written on the outside of the car-ton, or the carton will be refused.
- All parts and/or product will be repaired/replaced and shipped back to buyer; no credit will be issued.
OR
The Distributor may place an order for the warranty part and/or product and is
invoiced. The Distributor will receive a credit equal to the invoice only
after product is returned prepaid and verified to be defective.
FANTECH WARRANTY TERMS DO NOT PROVIDE FOR REPLACEMENT WITHOUT CHARGE PRIOR TO
INSPECTION FOR A DEFECT. REPLACEMENTS ISSUED IN ADVANCE OF DEFECT INSPECTION
ARE INVOICED, AND CREDIT IS PENDING INSPECTION OF RETURNED MATERIAL. DEFECTIVE
MATERIAL RETURNED BY END USERS SHOULD NOT BE REPLACED BY THE DISTRIBUTOR
WITHOUT CHARGE TO THE
Limitation of Warranty and Liability
This warranty does not apply to any Fantech product or part which has failed as a result of faulty installation or abuse, incorrect electrical con-nections or alterations made by others, or use under abnormal operating conditions or misapplication of the product or parts. We will not approve for payment any repair not made by us or our authorized agent without prior written consent. The foregoing shall constitute our sole and exclu-sive warranty and our sole exclusive liability, and is in lieu of any other warranties, whether written, oral, implied or statutory. There are no warranties which extend beyond the description on the page hereof. In no event, whether as a result of breach of contract, or warranty or alleged
Warning
Fantech products are designed and manufactured to provide reliable per-
formance, but they are not guaranteed to be 100% free from defects. Even
reliable products will experience occasional failures and this possi-bility
should be recognized by the user. If these products are used in a END USER, AS
CREDIT TO DISTRIBUTOR’S ACCOUNT WILL BE PENDING INSPECTION AND VERIFICATION OF
ACTUAL DEFECT BY FANTECH.
THE FOLLOWING WARRANTIES DO NOT APPLY
- Damages from shipping, either concealed or visible. Claim must be filed with freight company.
- Damages resulting from improper wiring or installation.
- Damages or failure caused by acts of God, or resulting from improper consumer procedures, such as:
- Improper maintenance
- Misuse, abuse, abnormal use, or accident, and
- Incorrect electrical voltage or current.
- Removal or any alteration made on the Fantech label control number or date of manufacture.
- Any other warranty, expressed, implied or written, and to any conse-quential or incidental damages, loss or property, revenues, or profit, or costs of removal, installation or reinstallation, for any breach of warranty.
WARRANTY VALIDATION
- The user must keep a copy of the bill of sale to verify purchase date.
- These warranties give you specific legal rights, and are subject to an applicable consumer protection legislation. You may have additional rights which vary from state to state.negligence, defect incorrect advice or other causes, shall Fantech be lia-ble for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of equipment or any other associ-ated equipment, cost of capital, cost of substitute equipment, facilities or services, downtime costs, or claims of customers of purchase for such damages. Fantech neither assumes or authorizes any person to assume for it any other liability in connection with the sale of product(s) or part(s). Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclu-sions may not apply to you.
- life support ventilation system where failure could result in loss or injury, the user should provide adequate backup ventilation, supplementary nat-ural ventilation, failure alarm system, or acknowledge willingness to accept the risk of such loss or injury.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>