Specifications
-
Model Numbers: KSTAP08MFC, KSTAP10MFC, KSTAP13MFC,
KSTAP13MFHC -
Compressor Manufacturer: Highly Meizhi Rechi
-
Refrigerant: R410A, R22
-
Oil Used: Ester Oil Vg68, SUNISO 4GSD, NMOC Ze-Gles RB68EP
-
Power Cord Length: 4.3′ (131cm)
-
Clearance Required: at least 23.6″ (60cm) from walls and
furniture
Product Usage Instructions
Air Conditioner Safety
Always read and obey all safety messages to avoid harm or damage
to people or properties.
Warnings
-
Warning: Indicates the possibility of death or
serious injury. -
Caution: Indicates the possibility of injury
or damage to properties.
Precautions
Failure to follow precautions could result in electrical shock,
fire, or personal injury:
-
The plug must be plugged into a properly installed and grounded
3-prong outlet. -
Do not use an extension cord.
-
Do not use an adapter.
-
Do not remove the ground prong.
Installation
Before starting the unit, observe all governing codes and
ordinances. Check the installation location:
-
Ensure a ground electrical outlet located near the
product. -
Provide free movement of air in the room to be cooled.
-
Allow at least 23.6″ (60cm) clearance from walls and
furniture.
Operation
Follow these steps for proper operation:
- Plug into a grounded 3-prong outlet.
- Do not remove the ground prong.
- Avoid using an extension cord or adapter.
Note:
Cabinet louvers must not be obstructed. Do not place the unit in
front of drapes or curtains as they may block the air intake.
FAQ
Q: What should I do if I need to dispose of the air
conditioner?
A: Consult with your local dealer or recycling center for
environmentally responsible disposal information.
Q: What type of oil is used in the compressor?
A: The compressor uses Ester Oil Vg68, SUNISO 4GSD, or NMOC
Ze-Gles RB68EP or equivalent oils based on the manufacturer’s
recommendations.
“`
INSTALLATION & OPERATIONS MANUAL
MOBILE ROOM AIR CONDITIONER
KSTAP08MFC KSTAP10MFC
KSTAP13MFC KSTAP13MFHC
REFERENCE
CONTENTS
Air Conditioner Safety ………………………………………………………… 2 Parts Description
……………………………………………………………….. 6 Control Panel ……………………………………………………………………. 7
Operation …………………………………………………………………………. 10 Accessories
……………………………………………………………………… 11 Installation ……………………………………………………………………….. 12
Maintenance …………………………………………………………………….. 17 Troubleshooting
………………………………………………………………… 18
Note: The descriptions in this user manual (text and figures) may vary
slightly from the model you purchased.
– 1 –
AIR CONDITIONER SAFETY
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages to avoid harm or damage to people, properties, etc.
WARNING
This symbol indicates
the possibility of death
or serious injury.
CAUTION
This symbol indicates
the possibility of injury or
damage to properties
WARNING
· This appliance is not intended for use by persons (including children) with
reduced physical, sensory, or mental capabilities or lack experience and
knowledge, unless they have been given supervision or instruction concerning
the use of appliance by a person responsible for their safety.
· This unit is designed for indoor use only. · The air conditioner must be
grounded. Incomplete grounding may
result in electric shocks. · The unit must be placed on the horizontal ground
to prevent tilting
and sliding. · A grounded breaker (check the product rating) time-delay fuse
or
circuit breaker with rated capacity must be installed to avoid possible
electric shocks. · Do not install the air conditioner in a place where there
is flammable gas or liquid. · If the power supply cord is damaged, it must be
replaced by the manufacturer or its service agent or a similar qualified
person. · The specification of the fuse are printed on the circuit board,
115V/Hz. · Do not touch the louvers. · Do not attempt to repair the air
conditioner by yourself. · In a lightning storm, please cut off the primary
power supply switch in order to prevent the machine from damage.
-2-
AIR CONDITIONER SAFETY
· Do not use a liquid or corrosive detergent to clean the appliance and do not
splash water or other liquids onto it, otherwise it may damage the plastic
components, even causing electric shocks.
· Do not operate the unit in a wet room such as the bathroom or laundry rooms.
· Do not touch the unit with wet or damp hands or when barefoot. · If your air
conditioner is not fitted with a supply cord and a plug,
an all-pole switch must be installed in the fixed wiring, and the distance
between contact should be no less than 3.0 mm (do not use an extension cord.)
· Do not pull the unit by the cord. · Do not remove any part of the unit
unless instructed by an authorized technician. · Do not move the unit until
the power has been cut off. · Do not operate the unit with a damaged plug or a
loose socket. · Reset your power supply cord by pressing RESET button on the
LCDI plug.
-3-
AIR CONDITIONER SAFETY
WARNING
Failure to follow the below precaution could result in electrical shock, fire,
or personal injury. 1. The plug must be plugged into an outlet that is
properly
installed and grounded to a 3 prong outlet. 2. Do not use an extension cord.
3. Do not use an adapter. 4. Do not remove the ground prong.
CAUTION
· Do not block the air inlet or air outlet, otherwise the cooling capacity
will be weakened, which could cause the system to stop operating.
· Close the windows and doors, otherwise the cooling capacity will be
weakened.
· If the air filter is very dirty, the cooling capacity will be weakened.
Please be sure to clean the air filter regularly.
Notice for R410A Models
Refrigerant leakage contributes to climate change. Refrigerant with lower
global warming potential (GWP) would contribute less to global warming than a
refrigerant with higher GWP, if leaked to the atmosphere. This appliance
contains a refrigerant fluid with a GWP equal to [2088]. This means that if a
1 kg of this refrigerant fluid would be leaks to the atmosphere, the impact on
global warming would be [2088] times higher than 1 kg of CO , over a period of
100 years. Never try to interfere with the refrigerant circuit or disassemble
the product by yourself, always ask a professional.
-4-
AIR CONDITIONER SAFETY
WARNING
1. When you need to dispose of the unit, consult with your local dealer or
local recycling center for information on how to dispose of the unit in an
environmentally responsible manner.
2. Please recycle or dispose of the packing material for product in an
environmentally responsible manner.
The oil of compressor used as below table:
Compressor Manufacturer or Trade mark
Refrigerant
The name of oil
Highly Meizhi Rechi
R410A R22
R410A R22
R410A
68HES-H or equivalent DIAMOND MS-56 or NM56EP or equivalent
ESTER OIL Vg68
SUNISO 4GSD or NM56EP or equivalent
NMOC Ze-Gles RB68EP or equivalent
-5-
FRONT VIEW
PARTS DESCRIPTION
REAR VIEW
NOTE: The descriptions in this user manual are text and figures,
and may be slightly different to the promotion information and actual
appliance. Please refer to the real appliance purchased. Thank you. The
working temperature range of the air conditioner is 16~35ºC (60~95ºF) under
cooling mode; 5~27ºC (41~80ºF) under heating mode.
-6-
CONTROL PANEL
There are four kinds of control panels, Fig A, Fig B, Fig C, and Fig D. The
actual shape shall prevail.
-7-
CONTROL PANEL
-8-
CONTROL PANEL
button
the
button, the timer
b.
button to
the
time.
time
other
the
press the timer button, there no
or
time is the
be
When the
is
the unit
the
the
button
the
press it
Note: With the unit on, press this button to set off timer.
With the unit off, press this button to set on timer.
button
this button, the
be time press
– 9 –
OPERATION
WARNING Failure to follow the below precaution could result in electrical
shock, fire, or personal injury. 1. Plug into a ground 3 prong outlet. 2. Do
not remove ground prong 3. Do not use an extension cord 4. Do not user an
adapter.
Before starting the unit
Observe all governing codes and ordinances. Check the location where the air
conditioner will be installed. Make sure you have everything necessary for
correct installation. The location should provide:
1. Ground electrical outlet located near the product. The power cord length
is 4.3′ (131cm). 2. Free movement of air in room to be cooled. 3. A large
enough opening for the air conditioner, installation parts are supplied for
double-hung windows. 4. Allow at least 23.6″ (60cm) clearance from walls and
furniture.
Note: Cabinet louvers mush not be obstructed. Do not place the unit in front
of drapes or curtains; they may block the air intake.
Heating operation mode (Cooling only model has no heating function)
1. Press the MODE button in a sequence until the heat indicator is lighted.
2. Press the “+” and “-” buttons to set your desired temperature. 3. Press the
FAN button to select the fan speed.
Cooling operation mode
1. Press the MODE button in a sequence until the cool indicator is lighted.
2. Press the “+” and “-” buttons to set your desired temperature. 3. Press the
FAN button to select the fan speed.
Drying operation mode
1. Press the MODE button in a sequence until the dry indicator is lighted. 2.
The fan will run at a fixed speed at this operation mode. 3. Close any windows
and doors for the best dehumidifying effect.
Note: The setting temperature and fan speed can not be adjusted. The setting
temperature is 25º (77º F) and the fan speed is low.
Fan operation mode
1. Press the MODE button in a sequence until the fan indicator is lighted. 2.
Press the FAN button to select the fan speed.
Note: The setting temperature can not be adjusted.
Auto-restart function:
If power to the unit is interrupted, the unit will restart itself in its last
used mode/ settings once power is restored. The compressor will restart after
4 minutes.
1. To set the “Auto-restart function”: Press the sleep button 10 times within
5 seconds, a buzzer will sound 4 times.
2. To cancel the “Auto-restart function”: Press the sleep button 10 times
within 5 seconds, a buzzer will sound 2 times.
– 10 –
ACCESSORIES
Parts
Parts Name
Adapter A, Exhaust duct, Adapter B (flat mouth), Window Slider Kit
Quantity 1 set
Type A Screws (#) Type B Screws (#) Security Bracket (#)
2pc
1/2″ screws 4pc 3/4″ screws 2pc
1pc
Type A foam seal (adhesive) (#)
2pc
Type B foam seal (non-adhesive) (#)
Adapter B (round mouth) (#), Wall exhaust Adapter (#)
Drain hose
1pc 1 set 1pc
Remote controller and Battery
1pc
Expansion screw sleeve (#),
4pc
Type C Screws (#)
4pc
NOTE: Optional parts (#), some models without.
Note: The descriptions in this manual (text and figures) may vary slightly from the model you purchased.
– 11 –
INSTALLATION
*If the unit you have bought has the pump drain outlet, as shown below, please drain in this way: Remove the pump drain from the back of the unit, attach the drain hose to the hole. Place the other end of the hose in the drainage way, or other drainage area such as a window.
Note: Make sure the hose is secure and there are no leaks. Direct the hose
towards the drain, making sure that there are no kinks that will stop the
water flow. Place the end of the hose into the drain, and make sure that the
end of the hose is down to let the water flow smoothly.
- When the water level of the bottom tray reaches predetermined level, the digital display area shows “P1” and the WATER FULL indicator light illuminates. Carefully move the unit to a drain location, remove the bottom drain plug, and restart the machine until the P1 symbol disappears. If the error repeats, call for service.
Note: Be sure to reinstall the bottom drain plug before using the unit.
– 12 –
INSTALLATION
Install the exhaust duct into the wall
1. Prepare a hole in the wall. Install the wall exhaust adapter onto the wall
by using 4 expansion screw sleeves and type C screws, be sure to fix
thoroughly.
2. Connect the exhaust duct to the wall exhaust adapter. (Fig. G)
Note: 1. The duct can be compressed to 27cm minimum and extended to 150cm maximum. It is better to keep the duct length to a minimum length. 2. Stretching or bending the duct excessively will affect the cooling efficiency. (As the following fig. shows)
No!
Yes!
Water drainage
- During dehumidifying mode, remove the upper drain plug from the back of the unit. Attach the drain hose to the hole. Place the other end of the hose in the drain or other drain location.
– 13 –
INSTALLATION
3. Carefully lower the window. Secure the vent panel in place with 4 type B
screws, plus one screw for each extension.
4. Cut the foam seal B (non-adhesive) to the window width. Stuff the foam
seal B between the glass and the window to prevent air and insects from
getting into the room.
5. Install the security bracket with a type B screw as shown.
Install the exhaust duct into the window Remove the unit with the packed
exhaust duct next to the window and then connect the adapter B (flat mouth) of
the exhaust duct with the window. (Fig. E)
– 14 –
INSTALLATION
2. Connect the exhaust duct to the Air outlet connector on the back of the
unit. Slide in the adapter A downwards until it is locked in place. (Fig. C)
Install the Window Slider Kit
1. Cut the foam seal (adhesive type) to the proper length and attach it to
the window sash.
2. Attach the Window Slider Kit to the window sash. Adjust the length of the
Window Slider Kit: loosen screw A to adjust the length of the Window Slider
Kit, then tighten the screw when the length is suitable. Note: the length of
the Window Slider Kit is 67.5 cm to 120 cm. – 15 –
INSTALLATION
Observe all governing codes and ordinances. Check the location where the air
conditioner will be installed. Ensure everything necessary for the correct
installation is available. 1. Install the portable air conditioner in a flat
and open location where the air outlets
will not be obstructed. 2. Keep the minimum clearance from walls or other
obstacles, as shown. 3. A level floor is required with maximum gradient of 10
degrees with the horizontal
plane is require to place the unit.
Unit Placement
1. Install the mobile air conditioner in a flat and open location where the
air outlets will not be obstructed.
2. Keep the minimum clearance from walls or other obstacles, as shown.
3. A level floor is required with maximum gradient of 10 degrees with the
horizontal plane is required to place the unit.
Note: 1. The air conditioner should not be used in the laundry
room or other confined space. 2. The plug should be accessible after the unit
is positioned.
Duct mount instruction
· In cooling, heating, and drying mode, the exhaust duct needs to be
installed. While in fan mode, the exhaust duct is not needed.
· According to the actual needs, the exhaust duct can be moderately compressed
and tensed, but cannot be arbitrarily stretched and bent.
· The exhaust duct can be connected with Windows or installed into the wall.
With the actual needs, you can make the installation with accessories of the
unit.
1. Install the adapter A and adapter B (flat mouth or round mouth) into the
exhaust duct as shown in Fig. A or Fig. B.
– 16 –
MAINTENANCE
WARNING Before cleaning the air conditioner, it must be shut down and the
electricity must be
cut off for more than 5 minutes, otherwise there might be the risk of electric
shocks. Do not use gasoline, benzene, thinner, liquid insecticide, or any
other chemicals on
the air conditioner, as these substances may adversely impact the unit and may
form cracks, or result deformation of plastic parts. Never attempt to clean
the unit by pouring water directly over any of the surface areas, as this will
cause deterioration of electrical components and wiring insulation.
Clean the Unit
When cleaning the exterior of the unit, use a warm, damp towel.
Clean the Air Filter
1. Remove the air filter Take out the upper air filter and the lower air
filter. Note: There are two types about the low air intake grille, please
refer to Fig. 1 or Fig. 2. If the low air intake with a screw, please remove
the screw at first.
2. Clean the air filter Use a vacuum cleaner to clean the air filter. If the
air filter is very dirty, wash it in warm water (below 104F (40C) with a mild
detergent, and then dry the filter in a shaded area.
3. Reinstall the dried filer in reverse order of removal. Put the filter
cover back to its place.
Note: If you do not use the unit for a long time, please pull out the rubber
plug to drain the inside water out referring to the right figure.
– 17 –
TROUBLESHOOTING
First, try the solutions suggested here to possibly avoid the cost of a service call.
Air Condition Will Not Operate
Causes
Solutions
· The power switch is released. · Power supply failure · The fuse is burnt. ·
It doesn’t reach the setting time for
starting up.
· Switch on the power. · Wait for the recovery of power supply. · Replace the fuse by a professional. · Wait or reset the original setting.
Unit Doesn’t Start When Pressing ON/OFF Button
Causes
Solutions
· It has not been four minutes after switch · Wait four minutes.
off.
· Reset the setting temperature.
· Room temperature is lower than the setting
temperature under cooling mode or higher
than setting temperature under heating
mode (if applicable).
There is Air Flow But No Cooling Effect
Causes
Solutions
· Mistakes in temperature setting. · The air filter is blocked by dust. · The
air inlet or outlet of machine is
blocked. · Turn the air conditioner on in a very
hot room. · Cooling capacity is insufficient. · The doors or windows are open.
· Set a proper temperature, setting temperature should be lower than ambient
temperature.
· Clean the air filter. · Remove the obstruction. · Allow additional time to
remove stored
heat from walls, ceiling, floor, and furniture. · Reconfirm that the cooling
capacity purchased is the correct size for the room square footage. · Close
the doors and windows.
Air Condition Will Not Operate
Causes
Solutions
· The ground is not level or flat enough. · Place the unit on a flat, level ground if possible.