Keystone KSTAP08MFC Mobile Room Air Conditioner Instruction Manual

June 28, 2024
Keystone

KSTAP08MFC Mobile Room Air Conditioner

“`html

Specifications

  • Model Numbers: KSTAP08MFC, KSTAP10MFC, KSTAP13MFC,
    KSTAP13MFHC

  • Compressor Manufacturer: Highly Meizhi Rechi

  • Refrigerant: R410A, R22

  • Oil Used: Ester Oil Vg68, SUNISO 4GSD, NMOC Ze-Gles RB68EP

  • Power Cord Length: 4.3′ (131cm)

  • Clearance Required: at least 23.6″ (60cm) from walls and
    furniture

Product Usage Instructions

Air Conditioner Safety

Always read and obey all safety messages to avoid harm or damage
to people or properties.

Warnings

  • Warning: Indicates the possibility of death or
    serious injury.

  • Caution: Indicates the possibility of injury
    or damage to properties.

Precautions

Failure to follow precautions could result in electrical shock,
fire, or personal injury:

  1. The plug must be plugged into a properly installed and grounded
    3-prong outlet.

  2. Do not use an extension cord.

  3. Do not use an adapter.

  4. Do not remove the ground prong.

Installation

Before starting the unit, observe all governing codes and
ordinances. Check the installation location:

  • Ensure a ground electrical outlet located near the
    product.

  • Provide free movement of air in the room to be cooled.

  • Allow at least 23.6″ (60cm) clearance from walls and
    furniture.

Operation

Follow these steps for proper operation:

  1. Plug into a grounded 3-prong outlet.
  2. Do not remove the ground prong.
  3. Avoid using an extension cord or adapter.

Note:

Cabinet louvers must not be obstructed. Do not place the unit in
front of drapes or curtains as they may block the air intake.

FAQ

Q: What should I do if I need to dispose of the air

conditioner?

A: Consult with your local dealer or recycling center for
environmentally responsible disposal information.

Q: What type of oil is used in the compressor?

A: The compressor uses Ester Oil Vg68, SUNISO 4GSD, or NMOC
Ze-Gles RB68EP or equivalent oils based on the manufacturer’s
recommendations.

“`

INSTALLATION & OPERATIONS MANUAL
MOBILE ROOM AIR CONDITIONER

KSTAP08MFC KSTAP10MFC

KSTAP13MFC KSTAP13MFHC
REFERENCE

CONTENTS
Air Conditioner Safety ………………………………………………………… 2 Parts Description ……………………………………………………………….. 6 Control Panel ……………………………………………………………………. 7 Operation …………………………………………………………………………. 10 Accessories ……………………………………………………………………… 11 Installation ……………………………………………………………………….. 12 Maintenance …………………………………………………………………….. 17 Troubleshooting ………………………………………………………………… 18
Note: The descriptions in this user manual (text and figures) may vary slightly from the model you purchased.
– 1 –

AIR CONDITIONER SAFETY

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages to avoid harm or damage to people, properties, etc.

WARNING
This symbol indicates
the possibility of death
or serious injury.

CAUTION
This symbol indicates
the possibility of injury or
damage to properties

WARNING
· This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack experience and knowledge, unless they have been given supervision or instruction concerning the use of appliance by a person responsible for their safety.
· This unit is designed for indoor use only. · The air conditioner must be grounded. Incomplete grounding may
result in electric shocks. · The unit must be placed on the horizontal ground to prevent tilting
and sliding. · A grounded breaker (check the product rating) time-delay fuse or
circuit breaker with rated capacity must be installed to avoid possible electric shocks. · Do not install the air conditioner in a place where there is flammable gas or liquid. · If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. · The specification of the fuse are printed on the circuit board, 115V/Hz. · Do not touch the louvers. · Do not attempt to repair the air conditioner by yourself. · In a lightning storm, please cut off the primary power supply switch in order to prevent the machine from damage.

-2-

AIR CONDITIONER SAFETY
· Do not use a liquid or corrosive detergent to clean the appliance and do not splash water or other liquids onto it, otherwise it may damage the plastic components, even causing electric shocks.
· Do not operate the unit in a wet room such as the bathroom or laundry rooms.
· Do not touch the unit with wet or damp hands or when barefoot. · If your air conditioner is not fitted with a supply cord and a plug,
an all-pole switch must be installed in the fixed wiring, and the distance between contact should be no less than 3.0 mm (do not use an extension cord.) · Do not pull the unit by the cord. · Do not remove any part of the unit unless instructed by an authorized technician. · Do not move the unit until the power has been cut off. · Do not operate the unit with a damaged plug or a loose socket. · Reset your power supply cord by pressing RESET button on the LCDI plug.
-3-

AIR CONDITIONER SAFETY
WARNING
Failure to follow the below precaution could result in electrical shock, fire, or personal injury. 1. The plug must be plugged into an outlet that is properly
installed and grounded to a 3 prong outlet. 2. Do not use an extension cord. 3. Do not use an adapter. 4. Do not remove the ground prong.
CAUTION
· Do not block the air inlet or air outlet, otherwise the cooling capacity will be weakened, which could cause the system to stop operating.
· Close the windows and doors, otherwise the cooling capacity will be weakened.
· If the air filter is very dirty, the cooling capacity will be weakened. Please be sure to clean the air filter regularly.
Notice for R410A Models
Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [2088]. This means that if a 1 kg of this refrigerant fluid would be leaks to the atmosphere, the impact on global warming would be [2088] times higher than 1 kg of CO , over a period of 100 years. Never try to interfere with the refrigerant circuit or disassemble the product by yourself, always ask a professional.
-4-

AIR CONDITIONER SAFETY
WARNING
1. When you need to dispose of the unit, consult with your local dealer or local recycling center for information on how to dispose of the unit in an environmentally responsible manner.
2. Please recycle or dispose of the packing material for product in an environmentally responsible manner.

The oil of compressor used as below table:

Compressor Manufacturer or Trade mark

Refrigerant

The name of oil

Highly Meizhi Rechi

R410A R22
R410A R22
R410A

68HES-H or equivalent DIAMOND MS-56 or NM56EP or equivalent
ESTER OIL Vg68
SUNISO 4GSD or NM56EP or equivalent
NMOC Ze-Gles RB68EP or equivalent

-5-

FRONT VIEW

PARTS DESCRIPTION

REAR VIEW

NOTE: The descriptions in this user manual are text and figures,
and may be slightly different to the promotion information and actual appliance. Please refer to the real appliance purchased. Thank you.
The working temperature range of the air conditioner is 16~35ºC (60~95ºF) under cooling mode; 5~27ºC (41~80ºF) under heating mode.
-6-

CONTROL PANEL
There are four kinds of control panels, Fig A, Fig B, Fig C, and Fig D. The actual shape shall prevail.
-7-

CONTROL PANEL
-8-

CONTROL PANEL

button

the

button, the timer

b.

button to

the

time.

time

other

the

press the timer button, there no

or

time is the

be

When the

is

the unit

the

the

button

the

press it

Note: With the unit on, press this button to set off timer.

With the unit off, press this button to set on timer.

button

this button, the

be time press

– 9 –

OPERATION
WARNING Failure to follow the below precaution could result in electrical shock, fire, or personal injury. 1. Plug into a ground 3 prong outlet. 2. Do not remove ground prong 3. Do not use an extension cord 4. Do not user an adapter.
Before starting the unit
Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. The location should provide:
1. Ground electrical outlet located near the product. The power cord length is 4.3′ (131cm). 2. Free movement of air in room to be cooled. 3. A large enough opening for the air conditioner, installation parts are supplied for
double-hung windows. 4. Allow at least 23.6″ (60cm) clearance from walls and furniture.
Note: Cabinet louvers mush not be obstructed. Do not place the unit in front of drapes or curtains; they may block the air intake.
Heating operation mode (Cooling only model has no heating function)
1. Press the MODE button in a sequence until the heat indicator is lighted. 2. Press the “+” and “-” buttons to set your desired temperature. 3. Press the FAN button to select the fan speed.
Cooling operation mode
1. Press the MODE button in a sequence until the cool indicator is lighted. 2. Press the “+” and “-” buttons to set your desired temperature. 3. Press the FAN button to select the fan speed.
Drying operation mode
1. Press the MODE button in a sequence until the dry indicator is lighted. 2. The fan will run at a fixed speed at this operation mode. 3. Close any windows and doors for the best dehumidifying effect.
Note: The setting temperature and fan speed can not be adjusted. The setting temperature is 25º (77º F) and the fan speed is low.
Fan operation mode
1. Press the MODE button in a sequence until the fan indicator is lighted. 2. Press the FAN button to select the fan speed.
Note: The setting temperature can not be adjusted.
Auto-restart function:
If power to the unit is interrupted, the unit will restart itself in its last used mode/ settings once power is restored. The compressor will restart after 4 minutes.
1. To set the “Auto-restart function”: Press the sleep button 10 times within 5 seconds, a buzzer will sound 4 times.
2. To cancel the “Auto-restart function”: Press the sleep button 10 times within 5 seconds, a buzzer will sound 2 times.
– 10 –

ACCESSORIES

Parts

Parts Name
Adapter A, Exhaust duct, Adapter B (flat mouth), Window Slider Kit

Quantity 1 set

Type A Screws (#) Type B Screws (#) Security Bracket (#)

2pc
1/2″ screws 4pc 3/4″ screws 2pc
1pc

Type A foam seal (adhesive) (#)

2pc

Type B foam seal (non-adhesive) (#)
Adapter B (round mouth) (#), Wall exhaust Adapter (#)
Drain hose

1pc 1 set 1pc

Remote controller and Battery

1pc

Expansion screw sleeve (#),

4pc

Type C Screws (#)

4pc

NOTE: Optional parts (#), some models without.

Note: The descriptions in this manual (text and figures) may vary slightly from the model you purchased.

– 11 –

INSTALLATION
*If the unit you have bought has the pump drain outlet, as shown below, please drain in this way: Remove the pump drain from the back of the unit, attach the drain hose to the hole. Place the other end of the hose in the drainage way, or other drainage area such as a window.
Note: Make sure the hose is secure and there are no leaks. Direct the hose towards the drain, making sure that there are no kinks that will stop the water flow. Place the end of the hose into the drain, and make sure that the end of the hose is down to let the water flow smoothly.

  • When the water level of the bottom tray reaches predetermined level, the digital display area shows “P1” and the WATER FULL indicator light illuminates. Carefully move the unit to a drain location, remove the bottom drain plug, and restart the machine until the P1 symbol disappears. If the error repeats, call for service.
    Note: Be sure to reinstall the bottom drain plug before using the unit.
    – 12 –

INSTALLATION
Install the exhaust duct into the wall
1. Prepare a hole in the wall. Install the wall exhaust adapter onto the wall by using 4 expansion screw sleeves and type C screws, be sure to fix thoroughly.
2. Connect the exhaust duct to the wall exhaust adapter. (Fig. G)

Note: 1. The duct can be compressed to 27cm minimum and extended to 150cm maximum. It is better to keep the duct length to a minimum length. 2. Stretching or bending the duct excessively will affect the cooling efficiency. (As the following fig. shows)

No!

Yes!

Water drainage

  • During dehumidifying mode, remove the upper drain plug from the back of the unit. Attach the drain hose to the hole. Place the other end of the hose in the drain or other drain location.

– 13 –

INSTALLATION
3. Carefully lower the window. Secure the vent panel in place with 4 type B screws, plus one screw for each extension.
4. Cut the foam seal B (non-adhesive) to the window width. Stuff the foam seal B between the glass and the window to prevent air and insects from getting into the room.
5. Install the security bracket with a type B screw as shown.
Install the exhaust duct into the window Remove the unit with the packed exhaust duct next to the window and then connect the adapter B (flat mouth) of the exhaust duct with the window. (Fig. E)
– 14 –

INSTALLATION
2. Connect the exhaust duct to the Air outlet connector on the back of the unit. Slide in the adapter A downwards until it is locked in place. (Fig. C)
Install the Window Slider Kit
1. Cut the foam seal (adhesive type) to the proper length and attach it to the window sash.
2. Attach the Window Slider Kit to the window sash. Adjust the length of the Window Slider Kit: loosen screw A to adjust the length of the Window Slider Kit, then tighten the screw when the length is suitable. Note: the length of the Window Slider Kit is 67.5 cm to 120 cm. – 15 –

INSTALLATION
Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Ensure everything necessary for the correct installation is available. 1. Install the portable air conditioner in a flat and open location where the air outlets
will not be obstructed. 2. Keep the minimum clearance from walls or other obstacles, as shown. 3. A level floor is required with maximum gradient of 10 degrees with the horizontal
plane is require to place the unit.
Unit Placement
1. Install the mobile air conditioner in a flat and open location where the air outlets will not be obstructed.
2. Keep the minimum clearance from walls or other obstacles, as shown.
3. A level floor is required with maximum gradient of 10 degrees with the horizontal plane is required to place the unit.
Note: 1. The air conditioner should not be used in the laundry
room or other confined space. 2. The plug should be accessible after the unit is positioned.
Duct mount instruction
· In cooling, heating, and drying mode, the exhaust duct needs to be installed. While in fan mode, the exhaust duct is not needed.
· According to the actual needs, the exhaust duct can be moderately compressed and tensed, but cannot be arbitrarily stretched and bent.
· The exhaust duct can be connected with Windows or installed into the wall. With the actual needs, you can make the installation with accessories of the unit.
1. Install the adapter A and adapter B (flat mouth or round mouth) into the exhaust duct as shown in Fig. A or Fig. B.
– 16 –

MAINTENANCE
WARNING Before cleaning the air conditioner, it must be shut down and the electricity must be
cut off for more than 5 minutes, otherwise there might be the risk of electric shocks. Do not use gasoline, benzene, thinner, liquid insecticide, or any other chemicals on
the air conditioner, as these substances may adversely impact the unit and may form cracks, or result deformation of plastic parts. Never attempt to clean the unit by pouring water directly over any of the surface areas, as this will cause deterioration of electrical components and wiring insulation.
Clean the Unit
When cleaning the exterior of the unit, use a warm, damp towel.
Clean the Air Filter
1. Remove the air filter Take out the upper air filter and the lower air filter. Note: There are two types about the low air intake grille, please refer to Fig. 1 or Fig. 2. If the low air intake with a screw, please remove the screw at first.
2. Clean the air filter Use a vacuum cleaner to clean the air filter. If the air filter is very dirty, wash it in warm water (below 104F (40C) with a mild detergent, and then dry the filter in a shaded area.
3. Reinstall the dried filer in reverse order of removal. Put the filter cover back to its place.
Note: If you do not use the unit for a long time, please pull out the rubber plug to drain the inside water out referring to the right figure.
– 17 –

TROUBLESHOOTING

First, try the solutions suggested here to possibly avoid the cost of a service call.

Air Condition Will Not Operate

Causes

Solutions

· The power switch is released. · Power supply failure · The fuse is burnt. · It doesn’t reach the setting time for
starting up.

· Switch on the power. · Wait for the recovery of power supply. · Replace the fuse by a professional. · Wait or reset the original setting.

Unit Doesn’t Start When Pressing ON/OFF Button

Causes

Solutions

· It has not been four minutes after switch · Wait four minutes.

off.

· Reset the setting temperature.

· Room temperature is lower than the setting

temperature under cooling mode or higher

than setting temperature under heating

mode (if applicable).

There is Air Flow But No Cooling Effect

Causes

Solutions

· Mistakes in temperature setting. · The air filter is blocked by dust. · The air inlet or outlet of machine is
blocked. · Turn the air conditioner on in a very
hot room. · Cooling capacity is insufficient. · The doors or windows are open.

· Set a proper temperature, setting temperature should be lower than ambient temperature.
· Clean the air filter. · Remove the obstruction. · Allow additional time to remove stored
heat from walls, ceiling, floor, and furniture. · Reconfirm that the cooling capacity purchased is the correct size for the room square footage. · Close the doors and windows.

Air Condition Will Not Operate

Causes

Solutions

· The ground is not level or flat enough. · Place the unit on a flat, level ground if possible.

– 18 –

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals