Specifications
- Model Number: AVRX650UD
- UPC Code: 037332255365
- UPS Type: Line-Interactive
- Input Phase: Single-Phase
- Rated Input Current (Maximum Load): 3.04A
- Nominal Input Voltage(s) Supported: 220V AC; 230V AC; 240V
AC
Product Features
-
Reliable battery backup for desktop workstations and essential
home/office network components -
Backup support for power outages with varying backup time based
on load (up to 6 minutes at half load) -
4 Schuko CEE 7/7 outlets provide battery backup, surge
protection, and voltage regulation -
Automatic Voltage Regulation (AVR) corrects low- and
high-voltage conditions -
Premium protection from EMI/RFI line noise for better equipment
performance -
High efficiency (>95%) rating to save energy costs
-
Audible alarm and LED status indicators for constant
monitoring
Highlights
-
Protects equipment against blackouts, brownouts, surges, and
line noise -
Keeps AC power running during outages for safe file saves and
shutdowns -
Maintains continuous 230V output during voltage
fluctuations -
EMI/RFI filtering for improved equipment performance and
longevity -
Right-angle Schuko plug with 1.5m cord for easy connection in
tight spaces
Applications
-
Protect small network servers and network components against
power issues -
Safely shut down desktop PCs during extended power outages
Package Includes
-
AVRX650UD 230V 650VA 375W Line-Interactive UPS with 4
Outlets -
Owner’s manual
Versatile Installation Options
The ultra-compact UPS can be installed on horizontal or vertical
flat surfaces using mounting tabs on the bottom panel. The 1.5m
power cord with a right-angle Schuko CEE 7/7 plug allows easy
connection to AC outlets.
Product Usage Instructions
Initial Setup
-
Place the UPS on a stable surface near your devices.
-
Connect the UPS to a compatible AC outlet using the provided
power cord. -
Ensure the UPS is turned off before connecting any
devices.
Connecting Devices
-
Connect your essential devices to the Schuko outlets on the
UPS. -
Distribute the load evenly among the outlets for optimal
performance.
Monitoring and Maintenance
-
Regularly check the status LED to monitor the UPS
operation. -
Test the UPS periodically by simulating a power outage to
ensure proper functionality. -
Keep the UPS clean and free from dust to maintain optimal
performance.
Shutdown Procedure
-
In case of a power outage, save your work immediately upon
hearing the audible alarm. -
Shut down your devices properly to prevent data loss and
damage.
Frequently Asked Questions (FAQ)
Q: How long can the UPS provide backup power?
A: The backup time varies based on the load, but at half load
(188W), it can power devices for up to six minutes.
Q: Can the UPS correct both low and high voltage
conditions?
A: Yes, the Automatic Voltage Regulation (AVR) feature can
correct brownouts as low as 159V and overvoltages as high as 282V
back to nominal 230V power continuously.
“`
230V 650VA 375W Ultra-Compact Line-Interactive UPS – 4 Schuko Outlets, Desktop
/Wall-Mount
MODEL NUMBER: AVRX650UD
Ultra-compact UPS offers power protection for desktop workstations and other
essential home and office network components.
Features
650VA/375W/230V Battery Backup for Home and Office Workstations The AVR Series
line-interactive AVRX650UD UPS system with AVR provides reliable battery
backup and AC power protection against blackouts, brownouts, overvoltages,
surges and line noise that can damage valuable electronics or destroy data.
The 230V battery backup is ideal protection for desktop workstations and other
essential business and small-network office equipment. This UPS system is also
recommended for home networking applications, such as Wi-Fi, security cameras
and home theater components.
Reliable, Expandable Battery Backup Keeps You Operational Through Power
Outages Backup support allows you to work through short power failures and
gives you enough time to safely save files and shut down your system in case
of a prolonged blackout. Backup time varies according to load, but internal
battery should keep a half load (188W) powered as long as six minutes.
4 Schuko CEE 7/7 Outlets Protect Your Connected Components Four outlets
provide battery backup, 156 joules of surge protection and voltage regulation
for your crucial components.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and
performance problems caused by brownouts and overvoltages. The AVRX650UD can
correct brownouts as low as 159V and overvoltages as high as 282V back to
nominal 230V power continuously, all while keeping the battery fully charged
and ready to take over in case of power failure.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency
interference that can inflict hardware damage or data loss. This EMI/RFI
filtering also helps your connected components perform better and last longer.
Designed for High Efficiency to Help You Save Money and Protect the
Environment A >95% efficiency rating reduces BTU emissions, energy consumption
and, ultimately, your energy costs.
Audible Alarm and Status LED Keep You Informed Around the Clock The alarm and
LED report on/off status, battery mode operation, low-battery condition and
UPS fault.
1 / 5
Downloaded from Arrow.com.
Highlights
Protects equipment against blackouts, brownouts, transient surges and line
noise
Keeps AC power running during outages to allow time for file saves and safe
shutdown
Maintains continuous 230V nominal output during brownouts and overvoltages
EMI/RFI filtering helps your connected components perform better and last
longer
Right-angle Schuko plug with 1.5 m cord allows easy connection in confined
spaces
Applications
Protect your small network server and other network components against power
surges, line noise, brownouts, overvoltages and blackouts
Shut down desktop PCs and other equipment without data loss during long-term
power outages
Package Includes
AVRX650UD 230V 650VA 375W Line-Interactive UPS with 4 Outlets
Owner’s manual
Versatile Installation Options Give You Plenty of Choices The ultra-compact
housing features mounting tabs on the bottom panel for installing the UPS
system on any horizontal or vertical flat surface. The 1.5-meter power cord
with space-saving right-angle Schuko CEE 7/7 input connects to a compatible AC
outlet.
Specifications
OVERVIEW UPC Code UPS Type
037332255365 Line-Interactive
INPUT
Input Phase
Single-Phase
Rated input current (Maximum Load) 3.04A
Nominal Input Voltage(s) Supported 220V AC; 230V AC; 240V AC
UPS Input Connection Type
CEE 7/7 Schuko
UPS Input Cord Length (ft.)
4.92126
UPS Input Cord Length (m)
1.5
Input Frequency
50/60Hz Automatic frequency selection
OUTPUT Output Capacity (VA) Output Capacity (kVA) Output Capacity (Watts)
Output Capacity (kW) Output Capacity Details
Nominal Voltage Details Frequency Compatibility Frequency Compatibility
Details Output Voltage Regulation (Line Mode) Output Voltage Regulation
(Battery Mode) Output Receptacle Details Output AC Waveform (AC Mode) Output
AC Waveform (Battery Mode) Nominal Output Voltage(s) Supported Output
Receptacles
650 0.65 375 0.375 LINE MODE: 110% (±10%) UPS goes to FAULT MODE within 5
minutes / 120% (±10%) UPS goes to FAULT MODE immediately; BATTERY MODE: 110%
(±10%) UPS shutdown within 5 seconds 230V nominal output in battery mode 50 /
60 Hz Automatic frequency selection +10%, -18%
230V ±10% All outlets provide UPS battery backup and Automatic Voltage
Regulation Sine wave PWM sine wave
220V; 230V; 240V (4) CEE7/7
2 / 5
Downloaded from Arrow.com.
Individually Controllable Load Banks No
BATTERY Battery Type Runtime Full Load (min.) Runtime Half Load (min.) Expandable Runtime DC System Voltage (VDC) Battery Recharge Rate (Included Batteries)
Valve Regulated Lead Acid (VRLA) 12 min. (375W) 6 min. (188W) No 12
Less than 8 hours from 10% to 90%
VOLTAGE REGULATION Voltage Regulation Description
Overvoltage Correction Undervoltage Correction
Automatic voltage regulation (AVR) maintains line power operation with an
input voltage range of 159 to 282VAC (±5%)
Input voltages between 253 and 282 (±5%) are reduced by 15%
Input voltages between 159 and 207 (±5%) are boosted by 18%
USER INTERFACE, ALERTS & CONTROLS
Switches
Lighted on/off power switch
Audible Alarm
Audible alarm indicator reports POWER-FAILURE, LOW-BATTERY, OVERLOAD, FAULT and BATTERY EXPIRED status (see manual)
LED Indicators
Lighted LED power switch indicator reports POWER-FAILURE, LOW-BATTERY, OVERLOAD, FAULT and BATTERY EXPIRED status (see manual)
SURGE / NOISE SUPPRESSION EMI / RFI AC Noise Suppression AC Suppression Joule Rating AC Suppression Response Time
Yes 156 Instantaneous
PHYSICAL Primary Form Factor Installation Form Factors Supported with Included Accessories Primary UPS Depth (mm) Primary UPS Height (mm) Primary UPS Width (mm) Shipping Dimensions (hwd / in.) Shipping Weight (kg) UPS Power Module Dimensions (hwd, in.) UPS Power Module Weight (kg)
Desktop Tower; Ultra-compact desktop; Wallmount 245 91 163 9.29 x 5.43 x 12.24 4.78 3.58 x 6.42 x 9.65 4.54
3 / 5
Downloaded from Arrow.com.
UPS Power Module Weight (lbs.) Unit Dimensions (hwd / in.) Unit Weight (lbs.) Unit Weight (kg)
10 3.580 x 6.420 x 9.650 10.000 4.54
ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC Mode BTU / Hr. (Full Load) AC Mode Efficiency Rating (100% Load) Audible Noise
32° to 104°F (0° to 40°C) 5° to 113°F (-15° to 45°C ) 0 to 95%, non-condensing 63.99 >95% <40dB, 1 meter
COMMUNICATIONS
Network Management Card Description
Communications Interface
Network management not supported None
LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery Power (Setpoint)
High Voltage Transfer to Battery Power (Setpoint)
2-6 ms (typical); 10 ms (maximum) 159V (±5%) 282V (±5%)
FEATURES & SPECIFICATIONS Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features Green Energy-Saving Features Grounding Details
Cold-start operation supported Surge/noise protection Greater than 95% efficiency – GREEN UPS Yes
APPLICATIONS UPS Applications
Home/Office Desktop; Audio/Video
STANDARDS & COMPLIANCE Product Certifications Product Compliance
IEC 62040-2 RoHS; CE (Europe)
WARRANTY & SUPPORT
4 / 5
Downloaded from Arrow.com.
Product Warranty Period (International)
1000 Eaton Boulevard Cleveland, OH 44122 United States
https://tripplite.eaton.com
2-year limited warranty
© 2024 Eaton. All Rights Reserved. Eaton is a registered trademark. All other
trademarks
are the property of their respective owners.
5 / 5
Downloaded from Arrow.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>