Specifications

  • Lamp Type: DVP050-RGBW, DVP100-RGBW, DVP170-RGBW
  • Voltage: 10-14 VAC
  • Power: 33W, 85W, 180W
  • Color Temperature: All colors and Tunable white
  • Luminous Flux: 1200 lm, 3500 lm, 7000 lm
  • Ingress Protection Rate: IP68 (measured at 3m max depth)
  • IEC Protection Class: III
  • Operating Voltage: 10-14 VAC 50/60 Hz
  • Operation Restrictions: For operation only with a safety isolation transformer, no operation on DC voltages allowed

Product Usage Instructions

Installation Instructions
The luminaire must be completely submerged in water during operation.
If replacement is needed, the luminaire must be entirely removed from the water.

Technical specifications

DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(2\)

(*) Propulsion systems remains a tolerance of +/- 10% on luminous flux measurements @ 25°C ; 12VAC

  • For operation only with a safety isolation transformer
    Minimum input voltage: 10 VAC 50/60 Hz (at lamp terminals)

  • Nominal input voltage: 12 VAC 50/60 Hz (at lamp terminals)

  • Maximum input voltage: 14 VAC 50/60 Hz (at lamp terminals)

    • IEC Protection Class III
  • Maximum water temperature: +40°C

  • Ingress protection rate: IP68

  • measured at 3m

  • max depth = 3m

Remarks

Water conditions
Prevent damage to your pool lamps and wires due to unstable water conditions.
Your local government may have enacted guidelines for your pool water conditions to apply by. If not we strongly advise the following parameter specifications to be applied:

  • pH level 6,8 – 7,6
  • Free Chlorine max. 3ppm
  • Combined chlorine max. 1 ppm
  • Water temperature max +40°C and lamps need to be kept out of ice zones

Always adhere to the instructions provided by your chemical brand/supplier for the correct use and application of pool chemicals.
Salt water pools, or pools fitted with a salt water chlorine generator contain salt in the pool water. Salt is a corrosive material. Overdosage and/or consistent levels of salt increase the possibility of deterioration of your pool lamps and cables. As a rule of thumb, a concentration of 35gr/l salt can be accepted when pH values are between 7,2-7,4.

In any case, we urge proper use, care and maintenance of your installation, in order to mini-mize the effect of corrosion and deterioration.
Please be aware that pool lamps and cables with defects caused due to abnormalities in the water condition are not covered by our factory warranty.

Installation/maintenance

The luminaire is maintenance free If the luminaire needs to be replaced, it needs to be completely removed from the water

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid hazard
VISION Pro Pool lamps must be completely submerged into water during operation. Fixing the lamps with adhesives or silicone kit into a niche is not allowed
Not following these instructions, will void warranty.

Box contents

DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(5\)

Lamp type Connection kit Cable
DVP050-RGBW 513-0480 ; 1 washer for fixnut ; blue cable gasket 1 mm2
DVP100-RGBW 513-0636 ; 2 washers for fixnut ; orange cable gasket 1,5 mm2
DVP170-RGBW 513-0393 ; 3 washers for fixnut; green cable gasket 2,5 mm2

Installation instructions

Installing faceplateDURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp-
\(6\)

Installation instructions

Installing connector DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp-
\(7\)

Connector installation

DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(8\) DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(9\)

Installation specialties

DVP050 & PZA-WG
For installations with DVP050 & PZA-WG-S or PZA-WG-G: Please make sure to only use 1 silicone washer for the Fix nut DURATECH-D

DVP050 Removal tool
When DVP050 needs to be removed from the PZA-WG wall conduits, a special tool is needed (513-0491)*

  1. Insert the tool over the lamp, straight into the wall conduit
  2.  Twist the tool counter clockwise the lamp should be snapped into the 3 hooks of the tool
  3.  Pull the lamp straight out of the wall conduit DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(11\)

Wiring instructions Setup 1

For new installations
Each lamp is connected to the transformer by a separate cable

DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(12\)

2m cable included in lamp package Separate cable ( not included )
Always use a toroïdal transformer DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp-
\(13\)

STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE

  • The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps.
    These cable lenghts are calculated with worst case voltage drops in the electrical wiring.

Wiring instructions Setup 2

For existing or other installations
All lamps are connected to the transformer via 1 cable DURATECH-DVP050
-Vision-Pro-RGBW-Pool-Lamp- \(14\)

2m cable included in lamp package Separate cable ( not included )
Always use a toroïdal transformer DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp-
\(15\)

STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE

Wiring remarks

For installations with LINK Controller or LINK Master

Third party equipment such as frequency inverters and electric motors can generate excessive noise on the 230VAC / 400VAC power line.
This noise might be injected into the adjacent 12VAC power line and disturb the power line communication towards the VISION Pro RGBW lights.

To prevent this, please take care of the following:

Keep 230VAC / 400VAC power line cables at least 50cm separated over their full length from the 12VAC power line towards any RGB lights
Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable traysDURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(16\)

(**) Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable trays

Synchronizing

With LinkTouch

+ LINK Controller (PLP-REM or PLP-REM-350)*
+ LINK Master (DLM450 or DLM600)

First make sure the LinkTouch is paired (see manual LinkTouch)
Turn the lamps on and spin the color wheel on the LinkTouch until the lamps react.
If the lamps do not react, turn them off and back on untill they react to the color wheel. As soon as the lamps follow the color wheel: wait 1 minute. The lamps are now synced.

With Transmitter

+ LINK Controller (PLP-REM or PLP-REM-350)*
Turn the lamps on and push the UP button 10 times. Wait for 20 seconds, then turn the lamps off. Repeat this process until the lamps react to the remote. As soon as the lamps follow the remote: wait 1 minute. The lamps are now synced.

Manual synchronization (without DURALINK control products)

  1. Switch ON the 12 VAC line voltage and make sure that all lamps light up.
  2. Switch OFF the 12 VAC line voltage and wait for at least 1 minute
  3. Switch ON
  4. The lamps should now all be on color program 1: Blue

*PLP-REM or PLP-REM-350 need to have firmware V6.7 (29-07-20) or newer

Color programs

RGBW LAMPS

DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(16\)

*all color programs are dimmable if  LINK Touch, LINK Contr oller or LINK Master  are used (in PLC mode)

Troubleshooting

DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(19\)

Declaraction of Conformity
Declarations of conformity covering this product are available for download from the House of Duratech website: www.duratech.be

DURATECH-DVP050-Vision-Pro-RGBW-Pool-Lamp- \(20\)

Contact details

Propulsion Systems bv Dooren 72
1785 Merchtem, Belgium
Tel +32 2 461 02 53
www.duratech.be
info@propulsionsystems.be

We reserve the rights to change all or part of the contents of this document without prior notice

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals