COMMSCOPE CO-115592.3-EN Coexistence Singlemode Devices Instruction Manual
- June 24, 2024
- CommScope
Table of Contents
- COMMSCOPE CO-115592.3-EN Coexistence Singlemode Devices Instruction
- Solutions overview
- Example application
- PON standards – Overview
- Coexistence application overview
- Coexistence optical performance
- Example application
- NG4 CEx Ordering Information
- LGX CEx Ordering Information
- Features
- 3RU chassis
- LGX 1RU chassis
- Features
- Features
- NG4 1RU Chassis – All Front Access
- Features
- FACT NG4 Chassis
- Features
- EQUIPMENT PANEL FOR NG4/FACT MODULES
- Features
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
COMMSCOPE CO-115592.3-EN Coexistence Singlemode Devices Instruction
Manual
Solutions overview
Passive Optical Network (PON) standards have been designed to enable two or
more PON systems to co-exist over the same Optical Distribution Network (ODN)
thanks to the use of separate wavelengths for both upstream and downstream
communications. That allows increased data speed and the delivery of
additional services without replacing any of the existing passive fiber
network infrastructure, while keeping previous services active.
CommScope’s coexistence elements support your migration to next-generation PON
services while controlling costs.
Our portfolio of coexistence modules are designed to integrate into the
network using fiber panels installed near the optical line terminal (OLT) or
inside the optical distribution frame (ODF). They enable different generations
of PON technologies such as GPON,
XGS-PON, NG-PON2, 25GS MSA, 50GPON to coexist, potentially using different
optical split ratio. In addition, some modules have separate ports to enable
RF video, optical time domain reflectometry (OTDR), or WDM overlays. Many
modules feature an upgrade port enabling the addition of future services over
unused wavelengths.
CommScope’s CEx elements are available in 2 housing styles, LGX and NG4,
offering solutions for both inside plant (ISP) and outside plant (OSP)
deployment.
Example application
LGX | NG4 |
---|
Connectors
| LC/APC| 24| 24
SC/APC| 12| N/A
Operating Temperature| Outside Plant (OSP)-40°C to +70°C| Inside Plant
(ISP)-10°C to +65°C
Test Standards| IEC 61300-2-1, -9, -21, -22, -26 and
GR-1209/GR-1221 requirements.
| GR-1209/GR-1221 and GR-63
Our LGX solutions meet Outside plant (OSP) requirements of -40°C to +70°C
operating temperature environments, and are tested to IEC 61300-2-1, -9, -21,
-22, -26 and GR-1209/GR-1221 requirements.
Our NG4 solutions are available with LC/APC connectors, meet inside plant
(ISP) requirements of -10°C to +65°C operating temperature environments, and
are tested to GR-1209/GR-1221 and GR-63 requirements.
PON standards – Overview
Standard | Wavelengths (nm) |
---|---|
Application | Standard Reference |
GPON | ITU-TG.984.5 |
XGS-PON | ITU-TG.9807.1 |
25GS-PON
|
25GS-PON Specification 2.0 MSA
| 1260-1280 (UW0)
1290-1310 (UW1)
1284-1288 (UW3)
|
1356-1360 (DW0)
50G-PON
|
ITU-TG.9804.3
| 1260-1280 (option 1)
1290-1310 (option 2)
1284-1288 (option 3)
|
1340-1344
G.Sup.VHSP| ITU.TGsup. VHSP (draft)| Proposed 1284-1288 (option 3 from 50G)|
Proposed in 1310-1340 range
NG-PON2 (TWDM PON)| ITU-TG.989.2| 1524-1544| 1596-1603
Coexistence application overview
Coexistence optical performance
CEx Configuration | CEx 1 | CEx 2 | CEx 3 | CEx 4 | CEx 5 |
---|
Density
(number of circuits in chosen housing and connector type)
| NG4-LC/APC| 8| 6| 6| 4| 8
LGX-LC/APC| 8| 6| 6| 4| 8
LGX-SC/APC| 4| 3| 3| 2| 4
Application
| GPON with upgrade option| GPON, XGS-PON and
upgrade option
| GPON with RF video overlay and upgrade option| GPON, XGS-PON and NGPON2| GPON and XGS-PON
combi port and upgrade option
Passbands Wavelengths
|
1
|
GPON: 1290-1500nm
|
GPON: 1290-1500nm
|
GPON: 1290-1500nm
|
GPON: 1290-1500nm
| PON (COMBI): 1260-1500nm &
1575-1581nm
2
| UPG: 1260-1280nm & 1525-1650nm| XGS-PON: 1260-1280nm
& 1575-1581nm
|
RF: 1550-1560nm
| XGS-PON: 1260-1280nm
& 1575-1581nm
| UPG: 1525-1565nm & 1596-1650nm
3
|
NA
| UPG: 1525-1560nm & 1596-1650nm| UPG: 1260-1280nm, 1525-1540nm
& 1575-1650nm
| NG-PON2: 1524-1544nm
& 1596-1603nm
|
NA
4| NA| NA| NA| UPG: 1550-1560 & 1613-1650nm| NA
Insertion Loss
| COM to 1| ≤0.8dB| ≤0.8dB| ≤0.8dB| ≤0.8dB| ≤0.8dB
COM to 2| ≤0.6dB| ≤1.2dB| ≤1.2dB| ≤1.2dB| ≤0.6dB
COM to 3| NA| ≤1.2dB| ≤1.2dB| ≤1.4dB| NA
COM to 4| NA| NA| NA| ≤1.4dB| NA
Maximum Optical Input Power| +23dBm| +23dBm| +23dBm| +23dBm| +23dBm
Isolation
| COM to 1| ≥30dB| ≥30dB| ≥30dB| ≥30dB| ≥30dB
COM to 2| ≥15dB| ≥30dB| ≥30dB| ≥30dB| ≥15dB
COM to 3| NA| ≥15dB| ≥15dB| ≥30dB| NA
COM to 4| NA| NA| NA| ≥15dB| NA
Return Loss| ≥50dB| ≥50dB| ≥50dB| ≥50dB| ≥50dB
Polarization Dependent Loss (PDL)|
≤0.3dB
|
≤0.3dB
|
≤0.3dB
|
≤ 0.3dB
|
≤0.3dB
Polarization Mode Dispersion (PMD)|
≤0.5ps/km0.5
|
≤0.5ps/km0.5
|
≤0.5ps/km0.5
|
≤0.5ps/km0.5
|
≤0.5ps/km0.5
Directivity| ≥50dB| ≥50dB| ≥50dB| ≥50dB| ≥50dB
Example application
NG4 CEx Ordering Information
MID | Description | Module Type |
---|---|---|
NG4-VXLFA08AAN | NG4 Module, CEx 1, 8 circuits, LC/APC connectors | CEx 1 |
NG4-VXLFB06AAN | NG4 Module, CEx 2, 6 circuits, LC/APC connectors | CEx 2 |
NG4-VXLFC06AAN | NG4 Module, CEx 3, 6 circuits, LC/APC connectors | CEx 3 |
NG4-VXLFE04AAN | NG4 Module, CEx 4, 4 circuits, LC/APC connectors | CEx 4 |
NG4-VXLFG08AAN | NG4 Module, CEx 5, 8 circuits, LC/APC connectors | CEx 5 |
TBD | NG4 Module, CEx 6, 4 circuits, LC/APC connectors | CEx 6 |
TBD | NG4 Module, CEx 6b, 4 circuits, LC/APC connectors | CEx 6b |
TBD | NG4 Module, CEx 7, 3 circuits, LC/APC connectors | CEx 7 |
TBD | NG4 Module, CEx 8, 8 circuits, LC/APC connectors | CEx 8 |
TBD | NG4 Module, CEx 8b, 6 circuits, LC/APC connectors | CEx 8b |
LGX CEx Ordering Information
MID | Description | Module Type |
---|---|---|
LX1SXA08AAN | Single Width LGX Module, CEx 1, 8 circuits, LC/APC connectors |
CEx 1
LX1SXA04CCN| Single Width LGX Module, CEx 1, 4 circuits, SC/APC connectors|
CEx 1
LX1SXB06AAN| Single Width LGX Module, CEx 2, 6 circuits, LC/APC connectors|
CEx 2
LX1SXB03CCN| Single Width LGX Module, CEx 2, 3 circuits, SC/APC connectors|
CEx 2
LX1SXC06AAN| Single Width LGX Module, CEx 3, 6 circuits, LC/APC connectors|
CEx 3
LX1SXC03CCN| Single Width LGX Module, CEx 3, 3 circuits, SC/APC connectors|
CEx 3
LX1SXD04AAN| Single Width LGX Module, CEx 4, 4 circuits, LC/APC connectors|
CEx 4
LX1SXD02CCN| Single Width LGX Module, CEx 4, 2 circuits, SC/APC connectors|
CEx 4
LX1SXG08AAN| Single Width LGX Module, CEx 5, 8 circuits, LC/APC connectors|
CEx 5
LX1SXG04CCN| Single Width CEx 5, 4 circuits, SC/APC connectors| CEx 5
TBD| Single Width LGX Module, CEx 6, 4 circuits, LC/APC connectors| CEx 6
TBD| Single Width LGX Module, CEx 6, 3 circuits, SC/APC connectors| CEx 6
TBD| Single Width LGX Module, CEx 6b, 4 circuits, LC/APC connectors| CEx 6b
TBD| Single Width LGX Module, CEx 6b, 2 circuits, SC/APC connectors| CEx 6b
TBD| Single Width LGX Module, CEx 7, 3 circuits, LC/APC connectors| CEx 7
TBD| Single Width LGX Module, CEx 7, 3 circuits, SC/APC connectors| CEx 7
TBD| Single Width LGX Module, CEx 8, 8 circuits, LC/APC connectors| CEx 8
TBD| Single Width LGX Module, CEx 8, 4 circuits, SC/APC connectors| CEx 8
TBD| Single Width LGX Module, CEx 8b, 6 circuits, LC/APC connectors| CEx 8b
TBD| Single Width LGX Module, CEx 8b, 3 circuits, SC/APC connectors| CEx 8b
LGX 4RU back-to-back chassi
Features
- The LGX 4RU back-to-back chassis holds 14 single-width LGX modules per side or seven dual-width LGX modules per side
- Maximum density of 28 single-width LGX modules or 14 dual-width LGX modules
- 19-in. or 23-in. rack mount
- 5-in., 5-in., or 8-in. recess mounting options
- Dimensions (H x W x D): 9 x 17 x 15 inches
MID | Description | Color |
---|
FBPS-LGX-4RU-BLK
| LGX 4RU back-to-back chassis
Ships equipped with two pass-through modules (LGX-PASSTHUR-3BK)
|
Black
3RU chassis
Features:
- Maximum density of 14 single-width LGX modules or 7 dual-width LGX modules
- 19-in. rack mount
- Dimensions (H x W x D): 5 x 482 x 235 mm
MID | Description | Color |
---|---|---|
760252747 | FPS-OCM-I-F-BLK | Black |
LGX 1RU chassis
Features
- Holds three single-width LGX modules
- 19-inch rack mount
- Dimensions (H x W x D): 7 x 18.9 x 8.9 inches / 44 x 481 x 225 mm
MID | Description | Color |
---|---|---|
760250917 | LGX 1 RU chassis—FPS-OCM-K-F-BLK | Black |
NG4access® universal chassis
Features
- Single 4 RU and 2 RU chassis for all applications
- One single-high VAM per access tray loaded from rear side of chassis/frame
- Up to 24 single-high VAMs per 4 RU universal Up to 12 single-high VAMs per 2 RU universal chassis.
- Can be deployed as a standalone 19”/23” chassis in standard racks
NG4 1RU Chassis – All Front Access
Features
- 3 trays per chassis
- Chassis accepts single high standard NG4 modules (front connectors only)
- 6 modules per 1RU chassis
MID | Description | Color |
---|---|---|
760240294 | EHD-1U-NG4VAM | Black |
FACT NG4 Chassis
Features
- The FACT NG4 element includes two trays
- Each element can accommodate two single-height NG4 VAM modules
MID | Description |
---|---|
760239975 | FACT-1ENG4 |
EQUIPMENT PANEL FOR NG4/FACT MODULES
Features
- 19 inch/ETSI – 2 HU Panel – full front access
- Can accomodate up to 6 modules
MID | Description |
---|---|
760252389 | EQP-2U-6X-MOD-NG4 |
CommScope pushes the boundaries of communications technology with game- changing ideas and ground- breaking discoveries that spark profound human achievement. We collaborate with our customers and partners to design, create and build the world’s most advanced networks. It is our passion and commitment to identify the next opportunity and realize a better tomorrow. Discover more at commscope.com
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>