COMMSCOPE CO-115592.3-EN Coexistence Singlemode Devices Instruction Manual

June 24, 2024
CommScope

COMMSCOPE CO-115592.3-EN Coexistence Singlemode Devices Instruction

Manual

Solutions overview

Passive Optical Network (PON) standards have been designed to enable two or more PON systems to co-exist over the same Optical Distribution Network (ODN) thanks to the use of separate wavelengths for both upstream and downstream communications. That allows increased data speed and the delivery of additional services without replacing any of the existing passive fiber network infrastructure, while keeping previous services active.
CommScope’s coexistence elements support your migration to next-generation PON services while controlling costs.
Our portfolio of coexistence modules are designed to integrate into the network using fiber panels installed near the optical line terminal (OLT) or inside the optical distribution frame (ODF). They enable different generations of PON technologies such as GPON,
XGS-PON, NG-PON2, 25GS MSA, 50GPON to coexist, potentially using different optical split ratio. In addition, some modules have separate ports to enable RF video, optical time domain reflectometry (OTDR), or WDM overlays. Many modules feature an upgrade port enabling the addition of future services over unused wavelengths.
CommScope’s CEx elements are available in 2 housing styles, LGX and NG4, offering solutions for both inside plant (ISP) and outside plant (OSP) deployment.

Example application

    LGX NG4

Connectors

| LC/APC| 24| 24
SC/APC| 12| N/A
Operating Temperature| Outside Plant (OSP)-40°C to +70°C| Inside Plant (ISP)-10°C to +65°C
Test Standards| IEC 61300-2-1, -9, -21, -22, -26 and

GR-1209/GR-1221 requirements.

| GR-1209/GR-1221 and GR-63

Our LGX solutions meet Outside plant (OSP) requirements of -40°C to +70°C operating temperature environments, and are tested to IEC 61300-2-1, -9, -21, -22, -26 and GR-1209/GR-1221 requirements.
Our NG4 solutions are available with LC/APC connectors, meet inside plant (ISP) requirements of -10°C to +65°C operating temperature environments, and are tested to GR-1209/GR-1221 and GR-63 requirements.

PON standards – Overview

Standard Wavelengths (nm)
Application Standard Reference
GPON ITU-TG.984.5
XGS-PON ITU-TG.9807.1

25GS-PON

|

25GS-PON Specification 2.0 MSA

| 1260-1280 (UW0)

1290-1310 (UW1)

1284-1288 (UW3)

|

1356-1360 (DW0)

50G-PON

|

ITU-TG.9804.3

| 1260-1280 (option 1)

1290-1310 (option 2)

1284-1288 (option 3)

|

1340-1344

G.Sup.VHSP| ITU.TGsup. VHSP (draft)| Proposed 1284-1288 (option 3 from 50G)| Proposed in 1310-1340 range
NG-PON2 (TWDM PON)| ITU-TG.989.2| 1524-1544| 1596-1603

Coexistence application overview

Coexistence optical performance

CEx Configuration CEx 1 CEx 2 CEx 3 CEx 4 CEx 5

Density

(number of circuits in chosen housing and connector type)

| NG4-LC/APC| 8| 6| 6| 4| 8
LGX-LC/APC| 8| 6| 6| 4| 8
LGX-SC/APC| 4| 3| 3| 2| 4

Application

| GPON with upgrade option| GPON, XGS-PON and

upgrade option

| GPON with RF video overlay and upgrade option| GPON, XGS-PON and NGPON2| GPON and XGS-PON

combi port and upgrade option

Passbands Wavelengths

|

1

|

GPON: 1290-1500nm

|

GPON: 1290-1500nm

|

GPON: 1290-1500nm

|

GPON: 1290-1500nm

| PON (COMBI): 1260-1500nm &

1575-1581nm

2

| UPG: 1260-1280nm & 1525-1650nm| XGS-PON: 1260-1280nm

& 1575-1581nm

|

RF: 1550-1560nm

| XGS-PON: 1260-1280nm

& 1575-1581nm

| UPG: 1525-1565nm & 1596-1650nm

3

|

NA

| UPG: 1525-1560nm & 1596-1650nm| UPG: 1260-1280nm, 1525-1540nm

& 1575-1650nm

| NG-PON2: 1524-1544nm

& 1596-1603nm

|

NA

4| NA| NA| NA| UPG: 1550-1560 & 1613-1650nm| NA

Insertion Loss

| COM to 1| ≤0.8dB| ≤0.8dB| ≤0.8dB| ≤0.8dB| ≤0.8dB
COM to 2| ≤0.6dB| ≤1.2dB| ≤1.2dB| ≤1.2dB| ≤0.6dB
COM to 3| NA| ≤1.2dB| ≤1.2dB| ≤1.4dB| NA
COM to 4| NA| NA| NA| ≤1.4dB| NA
Maximum Optical Input Power| +23dBm| +23dBm| +23dBm| +23dBm| +23dBm

Isolation

| COM to 1| ≥30dB| ≥30dB| ≥30dB| ≥30dB| ≥30dB
COM to 2| ≥15dB| ≥30dB| ≥30dB| ≥30dB| ≥15dB
COM to 3| NA| ≥15dB| ≥15dB| ≥30dB| NA
COM to 4| NA| NA| NA| ≥15dB| NA
Return Loss| ≥50dB| ≥50dB| ≥50dB| ≥50dB| ≥50dB
Polarization Dependent Loss (PDL)|

≤0.3dB

|

≤0.3dB

|

≤0.3dB

|

≤ 0.3dB

|

≤0.3dB

Polarization Mode Dispersion (PMD)|

≤0.5ps/km0.5

|

≤0.5ps/km0.5

|

≤0.5ps/km0.5

|

≤0.5ps/km0.5

|

≤0.5ps/km0.5

Directivity| ≥50dB| ≥50dB| ≥50dB| ≥50dB| ≥50dB

Example application

NG4 CEx Ordering Information

MID Description Module Type
NG4-VXLFA08AAN NG4 Module, CEx 1, 8 circuits, LC/APC connectors CEx 1
NG4-VXLFB06AAN NG4 Module, CEx 2, 6 circuits, LC/APC connectors CEx 2
NG4-VXLFC06AAN NG4 Module, CEx 3, 6 circuits, LC/APC connectors CEx 3
NG4-VXLFE04AAN NG4 Module, CEx 4, 4 circuits, LC/APC connectors CEx 4
NG4-VXLFG08AAN NG4 Module, CEx 5, 8 circuits, LC/APC connectors CEx 5
TBD NG4 Module, CEx 6, 4 circuits, LC/APC connectors CEx 6
TBD NG4 Module, CEx 6b, 4 circuits, LC/APC connectors CEx 6b
TBD NG4 Module, CEx 7, 3 circuits, LC/APC connectors CEx 7
TBD NG4 Module, CEx 8, 8 circuits, LC/APC connectors CEx 8
TBD NG4 Module, CEx 8b, 6 circuits, LC/APC connectors CEx 8b

LGX CEx Ordering Information

MID Description Module Type
LX1SXA08AAN Single Width LGX Module, CEx 1, 8 circuits, LC/APC connectors

CEx 1
LX1SXA04CCN| Single Width LGX Module, CEx 1, 4 circuits, SC/APC connectors| CEx 1
LX1SXB06AAN| Single Width LGX Module, CEx 2, 6 circuits, LC/APC connectors| CEx 2
LX1SXB03CCN| Single Width LGX Module, CEx 2, 3 circuits, SC/APC connectors| CEx 2
LX1SXC06AAN| Single Width LGX Module, CEx 3, 6 circuits, LC/APC connectors| CEx 3
LX1SXC03CCN| Single Width LGX Module, CEx 3, 3 circuits, SC/APC connectors| CEx 3
LX1SXD04AAN| Single Width LGX Module, CEx 4, 4 circuits, LC/APC connectors| CEx 4
LX1SXD02CCN| Single Width LGX Module, CEx 4, 2 circuits, SC/APC connectors| CEx 4
LX1SXG08AAN| Single Width LGX Module, CEx 5, 8 circuits, LC/APC connectors| CEx 5
LX1SXG04CCN| Single Width CEx 5, 4 circuits, SC/APC connectors| CEx 5
TBD| Single Width LGX Module, CEx 6, 4 circuits, LC/APC connectors| CEx 6
TBD| Single Width LGX Module, CEx 6, 3 circuits, SC/APC connectors| CEx 6
TBD| Single Width LGX Module, CEx 6b, 4 circuits, LC/APC connectors| CEx 6b
TBD| Single Width LGX Module, CEx 6b, 2 circuits, SC/APC connectors| CEx 6b
TBD| Single Width LGX Module, CEx 7, 3 circuits, LC/APC connectors| CEx 7
TBD| Single Width LGX Module, CEx 7, 3 circuits, SC/APC connectors| CEx 7
TBD| Single Width LGX Module, CEx 8, 8 circuits, LC/APC connectors| CEx 8
TBD| Single Width LGX Module, CEx 8, 4 circuits, SC/APC connectors| CEx 8
TBD| Single Width LGX Module, CEx 8b, 6 circuits, LC/APC connectors| CEx 8b
TBD| Single Width LGX Module, CEx 8b, 3 circuits, SC/APC connectors| CEx 8b

LGX 4RU back-to-back chassi

Features

  • The LGX 4RU back-to-back chassis holds 14 single-width LGX modules per side or seven dual-width LGX modules per side
  • Maximum density of 28 single-width LGX modules or 14 dual-width LGX modules
  • 19-in. or 23-in. rack mount
  • 5-in., 5-in., or 8-in. recess mounting options
  • Dimensions (H x W x D): 9 x 17 x 15 inches
MID Description Color

FBPS-LGX-4RU-BLK

| LGX 4RU back-to-back chassis

Ships equipped with two pass-through modules (LGX-PASSTHUR-3BK)

|

Black

3RU chassis

Features:

  • Maximum density of 14 single-width LGX modules or 7 dual-width LGX modules
  • 19-in. rack mount
  • Dimensions (H x W x D): 5 x 482 x 235 mm
MID Description Color
760252747 FPS-OCM-I-F-BLK Black

LGX 1RU chassis

Features

  • Holds three single-width LGX modules
  • 19-inch rack mount
  • Dimensions (H x W x D): 7 x 18.9 x 8.9 inches / 44 x 481 x 225 mm
MID Description Color
760250917 LGX 1 RU chassis—FPS-OCM-K-F-BLK Black

NG4access® universal chassis

Features

  • Single 4 RU and 2 RU chassis for all applications
  • One single-high VAM per access tray loaded from rear side of chassis/frame
  • Up to 24 single-high VAMs per 4 RU universal Up to 12 single-high VAMs per 2 RU universal chassis.
  • Can be deployed as a standalone 19”/23” chassis in standard racks

NG4 1RU Chassis – All Front Access

Features

  • 3 trays per chassis
  • Chassis accepts single high standard NG4 modules (front connectors only)
  • 6 modules per 1RU chassis
MID Description Color
760240294 EHD-1U-NG4VAM Black

FACT NG4 Chassis

Features

  • The FACT NG4 element includes two trays
  • Each element can accommodate two single-height NG4 VAM modules
MID Description
760239975 FACT-1ENG4

EQUIPMENT PANEL FOR NG4/FACT MODULES

Features

  • 19 inch/ETSI – 2 HU Panel – full front access
  • Can accomodate up to 6 modules
MID Description
760252389 EQP-2U-6X-MOD-NG4

CommScope pushes the boundaries of communications technology with game- changing ideas and ground- breaking discoveries that spark profound human achievement. We collaborate with our customers and partners to design, create and build the world’s most advanced networks. It is our passion and commitment to identify the next opportunity and realize a better tomorrow. Discover more at commscope.com

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CommScope User Manuals

Related Manuals