SPARK MINDA Anti Theft Car Immobilizer User Manual
- June 22, 2024
- SPARK MINDA
Table of Contents
**SPARK MINDA Anti Theft Car Immobilizer User Manual
**
KIT Configuration
Immobilizer
Lock set with Antenna
**Transponder Keys
Fuel Tank Cap
**
Dimensions
System Block Diagram
Immobilizer system is used to provide additional security above a mechanical
lock. It incorporates a transponder which is embedded in the Key of the
vehicle lock. It has a unique ID. This ID is communicated to Engine ECU by
Immobilizer Unit. If the ID matches only then the Engine ECU allows the
vehicle to Start.
This product is belong to category :
Inductive communication equipment at distance from the line λ At a distance 2
π (denoted by m for high frequency wavelengths), the electric field intensity
is less or equal to 15u V/m devices.
Specification
- Environment : IP 67 Protected
- Rated Voltage : 12V D C
- Operating Voltage : 6. 0 V-16 V D C
- Operating Temp : -20°C – +80°C
- Storage Temp : -40°C – +85°C
- Combined Unit : Switch Assy. Lock with Antenna. Transponder Key. Immobilizer.
- Operating Current : Less than 200mA (IGN ON)
- Quiescent Current : Less than 150µA (IGN OFF)
- LF carrier frequency : 125 KHz
- Communication with Engine ECU : CAN with 500kbps
- Coupler : 8-Pole Connector
Transponder
- Make : NXP
- Part number : PCF7938XA ( Passive device, no external battery required for powering up )
- Secret Key : 96-Bit
- Encryption algorithm : HITAG-III
- Unique ID : 32-Bit
LF Antenna
- Description : LF antenna is design based on mechanical lockset requirement, transponder key distance from the antenna should not more than 30mm because antenna magnetic field range is 30mm. Immobilizer should energize the antenna so antenna inductance & resistance tuned based on 125KHz resonance frequency.
- Make : Minda
- Inductance : 500uH ± 5% @125KHz (On Lock)
- Resistance at 26°C : 7.5 Ohm ± 5%
CE Statement :
Hereby, Minda Corporation Ltd. declares that the radio equipment Immobilizer is in compliance with Directive 2014/53/EU. The full test of the EU declaration of conformity is available at the following internet address: https://sparkminda.com/
This radio equipment operates with the following frequency bands and maximum power: RFID 125KHz: 12.93 dBµA /m@3m Distance
A minimum separation distance of 20cm must be maintained between the user’s body and the device, including the antenna during body-worn operation to comply with the RF exposure requirements in Europe.
WARNING
Do not ingest the battery, Chemical Burn Hazard
(The remote control supplied with) This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
Keep new and used batteries away from children.
If the battery compartment does not close securely, stop using the product and keep it away from children.
If you think batteries might have been swallowed or placed inside any part of
the body, seek immediate medical attention.
WARNING
-
Replacement of a battery with an incorrect type that can defeat a safeguard;
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
Leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas
A battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas -
exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
-
CAUTION For coin/button battery used, please refer for further information to the user manual
FCC Regulations:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions : (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution:
➢ Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
ISED Notice
-
* This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
- this device may not cause interference, and
- this device must accept any interference, including interference that may cause undesired operation of the device.
- This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested built-in radios.
- The County Code Selection feature is disabled for products marketed in the US/ Canada.
Radiation Exposure Statement:
This equipment complies with I C radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.