FORTINET FAP234G Wireless Access Point User Guide
- June 24, 2024
- FORTINET
Table of Contents
- FAP234G Wireless Access Point
- Before you begin
- Package Contents
- FortiAP 234G
- Wall Installation
- Pole Installation
- Waterproof Cabling
- Interfaces
- Cautions and Warnings
- FR380143AM. The antenna information is provided in the antenna test report.
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QuickStart Guide
QuickStart Guide
FortiAP 234G
FAP-234G
FAP234G Wireless Access Point
This guide covers: FAP-234G
December 7, 2023
Copyright© 2023 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®,
FortiCare® and FortiGuard®, and certain other marks are registered trademarks
of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet
names herein may also be registered and/or common law trademarks of Fortinet.
All other product or company names may be trademarks of their respective
owners. Performance and other metrics contained herein were attained in
internal lab tests under ideal conditions, and actual performance and other
results may vary. Network variables, different network environments and other
conditions may affect performance results. Nothing herein represents any
binding commitment by Fortinet, and Fortinet disclaims all warranties, whether
express or implied, except to the extent Fortinet enters a binding written
contract, signed by Fortinet’s General Counsel, with a purchaser that
expressly warrants that the identified product will perform according to
certain expressly-identified performance metrics and, in such event, only the
specific performance metrics expressly identified in such binding written
contract shall be binding on Fortinet. For absolute clarity, any such warranty
will be limited to performance in the same ideal conditions as in Fortinet’s
internal lab tests. In no event does Fortinet make any commitment related to
future deliverables, features or development, and circumstances may change
such that any forward-looking statements herein are not accurate. Fortinet
disclaims in full any covenants, representations, and guarantees pursuant
hereto, whether express or implied. Fortinet reserves the right to change,
modify, transfer, or otherwise revise this publication without notice, and the
most current version of the publication shall be applicable. For Product
License Agreement / EULA and Warranty Terms, visit
https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
Before you begin
Register your device to access FortiGuard updates, cloud management, firmware
upgrades, technical support and warranty coverage.
https://support.fortinet.com
Default Logins
The Essentials
https://192.168.1.2
Username: admin
Password: leave blank
https://fortilan.forticloud.com
Username: user-defined
Password: user-defined
Admin Guide
For up-to-date FortiAP setup and configuration information, such as creating a
FortiAP profile, visit https://docs.fortinet.com/product/fortiap
Customer Service
For contracts, licensing, product registration and account management, contact
FortiCare Support at https://www.fortinet.com/support/contact
Self-service Resources
Access our knowledge base, forums, videos and technical experts at
https://www.fortinet.com/support/support-services/forticare-support
Thank you for choosing Fortinet
Package Contents
FortiAP 234G
FAP-234G
Setup Options
Power the device with the provided 802.3af/at PoE injector or FortiGate PoE
port.
PoE Installation
FortiLAN Cloud
Note: Use your FortiCloud credentials to log in, then click Inventory, Import AP Key and enter the Cloud Key on the device sticker
Direct Connection
Note: To self-configure,
preauthorize the FortiAP on your FortiGate Otherwise once connected, wait for
the FortiAP to appear on the Managed FortiAP page in FortiOS.
Network Connection
Note: Connect to the FortiAP using 192.168.1.2 with username admin and
set a password. Specify the FortiGate IP using:
cfg -a AC_IPADDR=0.0.0.0 cfg -c
where 0.0.0.0 is the FortiGate IP.c
Wall Installation
Your device mounts on a wall using the provided wall mount bracket and screws.
- Mark the location of the mounting bolts using the wall mount bracket
- Drill holes and hammer the bolts into the drilled holes
- Attach the wall mount bracket to the device using the provided mounting screws
- Secure the device on the wall using the mounting bolts
Pole Installation
Your device comes with a pole mount bracket, straps and screws. You can mount the device to a pole vertically.
- Attach the wall mount bracket, then pole mount bracket to the device using the provided mounting screws
- Loop the pole straps through the bracket slots, then around the pole
- Tighten the straps
Waterproof Cabling
Your device comes with IP67 rated Ethernet cable glands.
- Unscrew the sealing nut from the panel connector and remove the seal and claw
- Thread the RJ45 plug through the sealing nut, then the panel connector
- Wrap the seal and claw around the cable between the sealing nut and connector
- Insert the RJ45 plug into the port and screw the panel connector onto the threads
- Slide the seal and claw along the cable into the panel connector
- Threat the coupling ring onto the panel connector and tighten it
Interfaces
-
LED STATUS
Power
Green: Powered on; connected to a controller
Amber: Powered on; not connected to a controller
Off: Powered off
LAN
Green: Connected
Blinking Green: Data activity
Off: Not connected
WiFi
Green: SSID broadcasting
Blinking Green: Data activity
Off: WiFi not broadcasting -
LAN1 / PoE RJ45) 2.5 Gbps 802.3at PoE Ethernet interface
-
LAN2 / PoE RJ45 1 Gbps Ethernet interface
-
CONSOLE RJ45 CLI management
Cautions and Warnings
Environmental specifications
Ambient operating temperature: -30°C to 60°C
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)
Safety
Warning: Equipment intended for installation in Restricted Access Location.
Caution: This equipment is to be used in a Network Environment 0 per IECTR 62101. This product is connected only to PoE networks without routing to the outside plant.
This product is intended to be supplied by a Listed Direct Plug-In Power Unit marked LPS or Class 2 and rated 54Vdc, 0.6A from PoE source.
Grounding – To prevent damage to your equipment, connections that enter from
outside the building should pass through a lightning/surge protector, and be
properly grounded. Use an electrostatic discharge workstation (ESD) and/or
wear anti-static wrist strap while you work. In addition to the grounding
terminal of the plug, on the back panel, there is another, separate terminal
for earthing.
Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received;
including interference that may cause undesired operation. This equipment has
been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in residential
installation. This equipment generates, uses, and can radiate radio frequency
energy, and if it is not installed and used in accordance with the instruction
manual, it may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment This equipment complies with FCC radiation exposure
limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 62cm between the radiator and
your body. This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
Antenna Elevation
The elevation gain shall be configured in the cases of outdoor deployment,
dipole antenna use, and transmitting power in the 5150MHz-5250MHz UNII-1 band.
It is defined as the maximum antenna gain at 30 to 150 degrees above the
horizon. FAP-234G conforms to U.S. FCC limitations that the maximum allowable
21dBm EIRP power for an elevation below 30 degrees. The maximum limits
determined in the testing to limit the EIRP below 21dBm for outdoor use in
UNII-1 band are hardcoded in the firmware. See Appendix C in FCC Report
FR380143AM. The antenna information is provided in the antenna test report.
RF variables and settings
By default two RF variables are defined for every network. One for indoor
APs and one for outdoor APs. FAP-234G within a network can be configured to
the corresponding RF settings via the FortiAP profile.
Creating a FortiAP Profile
Refer to the Configuration Guide in creating a FortiAP profile at
https://docs.fortinet.com/product/fortiap
This device meets all the other requirements specified in Part 15E, Section
15.407 of the FCC Rules. Innovation, Science and Economic Development (ISED) –
Canada
This Class B digital apparatus complies with Canadian ICES-003.
Innovation, Science and Economic Development (ISED) – Canada
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
For product
available in the USA/Canada market, only channel 1~11 can be operated.
Selection of other channels is not possible. This equipment complies with ISED
radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operat- ed with minimum distance 38cm
between the radiator & your body.
The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall
be such that the equipment still complies with the e.i.r.p. limits specified
for point-to-point and non-point-to-point operation as appropriate.
Caution: The device for the band 5150-5250 MHz is only for indoor usage
to reduce potential for harmful interference to co-channel mobile satellite
systems.
Caution: The maximum antenna gain permitted for devices in the bands
5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit; and the
maximum antenna gain permitted for devices in the band 5725-5825 MHz shall
comply with the e.i.r.p. limits specified for point-to-point and non point-to-
point operation as appropriate.
(iii) where applicable, antenna type(s), antenna models(s), and worst-case
tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask
requirement set forth in section 6.2.2.3 shall be clearly indicated..
This radio transmitter (IC: 7280B-51018E01231 / Model: FAP-234G) has been
approved by ISED to operate with the antenna types listed below with the
maximum permissible gain and required antenna impedance for each antenna type
indicated. Antenna types not included in this list, having a gain greater than
the maximum gain indicated for that type, are strictly prohibited for use with
this device. This device and it’s antennas(s) must not be co-located or
operating in conjunction with any other antenna or transmitter except in
accordance with IC multi-transmitter product procedures.
Professional Installation Instructions
-
Installation personal
This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting. -
Installation location
The product shall be installed at a location where the radiating antenna can be kept 62/38cm from nearby person in normal operation condition to meet regulatory RF exposure requirement. -
Antenna
Use only the antennas which have been approved by the applicant. The non- approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC/IC limit and is prohibited. -
Installation procedure
Please refer to user’s manual for the detail. -
Warning
Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty.
European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
Note: * Only with DFS bands certification.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including, combinations
of software, firmware and hardware) provided by Fortinet or Fortinet’s
authorized partners to the end customer directly for use within the EU or
countries that have implemented the EU Directives and/or spectrum regulation.
Any
Fortinet products not obtained directly from
Fortinet or Fortinet’s authorized partners may not comply with EU Directives
and
Fortinet makes no assurances for such products.
Note: The full declaration of conformity for this product is available at
the link below: https://site.fortinet.com/ProductRegulatory/EU
The device is restricted to indoor use only when operating in the 5150 to 5350
MHz frequency range in the following countries:
| AT| BE| Be| HR| CY| CZ| OK| UK
---|---|---|---|---|---|---|---|---
EE| Fl| FR| OE| EL| HIU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK (NI)
Compliance with 2014/53/EU Radio Equipment Directive (RED)
In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table
provides information on the frequency bands used and the maximum RF transmit
power of the product for sale in the EU:
UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to
the power listed below:
2402-2480MHz less than 20dBm
2405-2480MHz less than 20dBm
2412-2472MHz less than 20dBm
5180-5240MHz less than 23dBm
5260-5320MHz less than 23dBm
5500-5700MHz less than 30dBm
5745-5825MHz less than 14dBm
5725-5875MHz less than 30dBm
5725-5875MHz less than 13.5dBm
5955-6415MHz less than 23dBm
Note: * Only with DFS bands certification.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment
Regulations 2017
The full Declaration of Conformity for this product is available in the link
below: https://site.fortinet.com/ProductRegulatory/UK UK
References
- Global Leader of Cybersecurity Solutions and Services | Fortinet
- FortiAP / FortiWiFi 7.4
- FortiCloud
- Welcome
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>