Zaptec ZM000173-2 Pro Charging station Instruction Manual

June 20, 2024
Zaptec

Zaptec Logo Zaptec Pro →
Installer Manual

Fully charged for your next adventure

Zaptec Pro

Zaptec ZM000173 2 Pro Charging station 

A Status indicator
B RFID zone
C MID model only: display showing total energy (kWh)
D Electrical outlet EN 62196-1/2,
Mode 3 Type 2
E Self-closing protective cover
WARNING!

  • Before installing this product, it’s important to read the following safety instructions. Failure to follow and apply all the instructions and procedures covered in this manual will invalidate the guarantee and cause Zaptec Charger AS and direct partners to waive all liability and claims for compensation.
  • This equipment must only be installed, repaired, and maintained by qualified personnel.
  • Repairs must be carried out by Zaptec or a pre-approved workshop.
  • All applicable local, regional, and national laws and regulations must be followed when installing, repairing, and maintaining the product.

Install the back plate

Mount the back plate and remove the cover on the junction box.
Use existing holes! Creating new holes in the back plate will invalidate the warranty.

Zaptec ZM000173 2 Pro Charging station - Connect

Connect the back plate

To reduce the risk of leaks in outdoor installations, please connect the cable to the bottom of the junction box on the backplate. If not possible, device must be properly sealed and checked. Connect the cables in the junction box in accordance with the electrical system at the location. We recommend using a sealant such as Sikaflex.

Zaptec ZM000173 2 Pro Charging station - Connect 1

No daisy chaining is allowed. It is only allowed when installation circuit breaker is no more than 40A.

Zaptec ZM000173 2 Pro Charging station - Connect 2

Perform electrical testing
Do not insert test probes, wires or anything else into the quick-release connector on the back plate. Voltage tests should be performed directly on the terminal screws.
The backplate connector is designed for permanent connections and should not be subject to a high number of mating cycles.

Zaptec ZM000173 2 Pro Charging station - box cover

Screw on the junction box cover
Use the correct cable seal G H

  • Small cable seal: 10–16 mm.
  • Large cable seal: 16–18.5 mm.

Zaptec ZM000173 2 Pro Charging station - Remove

Remove the front cover
Place the SmartKey J all the way to the bottom of the opening at the back of the charging station, ensuring it is positioned beneath the internal clip. To remove the front cover, pull the SmartKey toward yourself and slightly upward at the end of the movement.

Install the charging station

Position the charging station on the back plate so that there is no gap between them. Tighten the charging station using the four nuts I and fit the front cover.

Zaptec ZM000173 2 Pro Charging station - charging
station

Zaptec ZM000173 2 Pro Charging station - charging
station

Power up the installation
Switch on the power supply to the installation.
The yellow status indicator means that the system is performing internal checks. Confirm that the status indicator changes from yellow to green after 2–3 minutes.

Zaptec ZM000173 2 Pro Charging station - charging station
1

To commission your Zaptec Pro installation you need to configure and activate each charging station in the Zaptec Portal and Zaptec app.
In the app: configure network settings and electric grid.
In the portal: add to installation.
Test the charging stations

  • Perform an RCD test using a testing device with a Type 2 plug. The test must be performed in accordance with the testing device’s manual.
  • Carry out a test using an electric vehicle, test load or Mode 3 test equipment.
  • Perform any other tests according to local regulations and requirements.

Zaptec ZM000173 2 Pro Charging station - charging station
2

Product specifications

General

Parameter| Test condition| Value|

Unit

---|---|---|---
Dimensions| | H: 392 W: 258 D: 112| mm
Charging mode| | Mode 3, case B|
Weight| Including backplate| 5| kg
Degree of protection| | IP54|
Mechanical strength| | IK10|
Pollution degree| Installation environment| 4|
Support for ventilation| According to EN IEC 61851-1:2019, 6.3.2.2| No|
Access| According to EN IEC 61851-1:2019, 5.4| Restricted and non-restricted access|
Maximum altitude| | 2000| m
Max noise emission| With fan running| 47.5| dBA
Input cable cross section| | 2.5 to 10| mm²
Input cable diameter| | 10 to 18.5| mm
Ambient operating temperature| | -30 to 40| °C

Electrical

Parameter Symbol Value Unit
Rated voltage Un 230/400 V
Rated current In 32 A
Rated frequency 50 Hz
Overvoltage category III
Protection class I
Protection against electric shock According to EN IEC 61851-1:2019, 8.3 and
HD 60364-4-41:2017 Reinforced insulation as fault protection (between phases
and PE)

Integrated RCCB

Parameter Symbol Value Unit
Residual operating current IΔn 0.03 A
Operating characteristics Type B
Making and breaking capacity Im and IΔm 500 A
Rated conditional short-circuit current Inc and IΔc 10 kA
Normative standard EN 62423:2012

Integrated circuit breaker

Parameter Symbol Value Unit
Manufacturer and part number Lovato P1 MB 3P C40
Rated current In 40 A
Curve C
Nominal short-circuit breaking capacity Icn 10 kA
Normative standard EN 60947-2:2017, EN 60898-1:2019

Zaptec powers any EV

Zaptec Charger AS
Vassbotnen 1
4313 Sandnes
Norway
Made in Norway
zaptec.com
© Zaptec Charger AS 21.12.2023.
All rights reserved. MA-00014-B1

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals