ANVIZ SAC921 Single-Door Access Controller User Manual
- June 16, 2024
- ANVIZ
Table of Contents
- ANVIZ SAC921 Single-Door Access Controller
- Product Usage Instructions
- Frequently Asked Questions
- Access Controller
- Wiring Diagram
- Device Management
- User Management
- Network- Internet
- Basic Setup-System info
- Device Setting
- Recognition Mode
- Time Setup
- Access Control-Normally Open Close
- Alarm Setup
- Period Setting
- Access Setup
- Card
- Firmware Upgrade
- Initialization
- FCC Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ANVIZ SAC921 Single-Door Access Controller
Specifications
- Power Input: DV12V
- Relay Output
- TCP/IP RJ45
- Reader Interface
- Alarm Interface
- Door Sensor & Exit Button
Product Usage Instructions
Device Management
- Ensure your PC is on the same network segment as the device.
- Confirm your computer’s IP address.
- Check the device’s IP address and port to match with the computer.
- Connect the device to the computer via TCP/IP.
- Open Google Chrome and visit the login page using the default IP address, username, and password.
User Management
The User Page allows you to edit user information and register users
- Add User:
- User ID: Input the user ID number as a unique identifier.
- Password: Verify the password for the user.
- Identify Mode: Support RFID Card ID + Password or RFID Card + Password.
- User Name: Input the user’s name.
- Card No: Display the user’s card number for verification.
- Group: Select the access control group for the user.
- Personnel Validity Period: Set the start and expiration date.
- Click Download to get the user EXCEL template for editing personnel information.
Network Settings
- Internet:
- Sac921 supports Ethernet (Cable) or WIFI mode. Select WAN mode for internet connection.
- Auto Mode: Automatically connects to the internet via WIFI or Ethernet (Cable).
- Ethernet:
- Activate Ethernet mode IP Setup to choose Static IP or DHCP for network information.
- WIFI:
- Select AP or WIFI AP mode for the WIFI connection.
- Manual input AP name and password.
- Communication Mode:
- Select Server or Client mode with default port 5010.
- Activate communication password for security.
Basic Setup – System Info
View hardware basic parameters including Serial Number, Firmware Version, User and Record Capacity, etc. Ethernet and WIFI MAC addresses are displayed here.
Device Setting
Configure the Device ID number and Webserver login password here.
Frequently Asked Questions
Q: How do I reset the device to factory settings?
A: To reset the device to factory settings, locate the reset button on the device and press it for at least 10 seconds until the LEDs flash. The device will then revert to its default settings.
Q: Can I use multiple access controllers in a network?
A: Yes, you can use multiple access controllers on the same network by ensuring each controller has a unique IP address and proper network configuration to avoid conflicts.
Access Controller
Sac921 Single-Door Access Controller
- Complete solution for single-door access control with multiple readers.
- Power over Ethernet variant connects directly to a building’s structured cabling.
- PoE can provide up to 1A to drive a lock (recommend 1A total
- average to allow for power spikes).
- High-speed RS-485 connectivity with downstream devices. (OSDP)
- Onboard support for 5 inputs for all power, door, and alarm sensors.
- Note: only four inputs are available on the Wiegand Reader. 1 x Door Access Control
- 3,000 Cardholders
- Storage for 100,000 offline events
- 16 Access Groups & 32 Time Zone
Wiring Diagram
Device Management
- Sac921 uses a Web Server to manage the device. Before managing the terminal please check the PC’s network is at the same network segment in the network.
- The sac921 default IP address is 192.168.0.218 / User Name: Admin / Password: 12345.
- Step one: Confirm your computer IP
Check IP &Device Connection
- Step two: Check the device IP address in the device and ensure the port is the same as the computer. In the example, the default device ip is 192.168.0.218 Step three:
- Connect the device to the computer via TCP\IP. You can confirm if TCP\IP is ok in the picture below.
- Step four: Open Google Chrome and visit the login page
- The device’s default IP address is 192.168.0.218 / User Name: Admin / Password: 12345.
User Management
The User Page to edit user information and register users.
Add User
- User ID Input user ID number as System Employee Unique Identifier Password user verify password
- Identify Mode support RFID Card, ID+Password, and RFID Card + Password
- Personnel Validity Period: Set the start date to the expiration date.
- User Name Input User Name
- Card No Display user verify card number
- Group select the access control group for the user.
- Click “Download” to download the user EXCEL template, manually edit personnel information, and support the import and export of personnel information.
Network- Internet
- Sac921 supports the “Internet” option to set up the hardware’s network work mode: Ethernet (Cable) or WIFI.
- WAN Mode: Select the internet connection mode: Ethernet (Cable) or WIFI. And the device’s DNS address.
- Auto Mode: The device is connected to WIFI or Ethernet (Cable), and the device will automatically to connect the internet in the best way.
Network- Ethernet
- Option: Active Ethernet mode
- IP Setup: Select the Static IP or DHCP to get the device network information.
- Manual input or check device network information.
Network WIFI
- WIFI Mode Select AP or WIFI AP mode Device works as WIFI AP. The device can be connected by WIFI to manage the device via the Webserver.
- AP Name Mode: Manual named the AP or user default
- Default Name: Display the AP name.
- AP Password: display the AP connection password.
WIFI Mode Select WIFI
- Option: Active the option
- SSID: Input the wifi name (SSID Name)
- WiFi Password: Input WiFi connection password. Manual input or check of device network information
Network Communication Mode
- Communication Mode Select the Server or Client mode for a device
- Port : The network communication port. Device Default port is 5010.
- Comm PW : Active the communication password
- PW Setting: Active and set device network communication password, The application software needs the password to connect with the device.
Basic Setup-System info
- The hardware’s basic parameter information,(Serial Number, Firmware Version, User, Record Capacity ect.)
- Ethernet MAC: Ethernet MAC address
- WIFI MAC: WIFI MAC address
Device Setting
- Device ID: Device ID number
Admin Password: Webserver login password
Recognition Mode
Identify Mode: Set up the device’s default verify mode. Support the RFID Card, ID+Password, Card+Password
Time Setup
- Mode: Manual and automatic
- Time Format: Setup Time Display,24 or 12
- Date Format: Setup Date Display MM-DD-YY, YY-MM-DD or DD-MM-YY
Access Control-Normally Open Close
- Normally Open/Cloud: To set the device to control access for either normally open or normally closed periods.
- Using a 7-day week as a cycle, it cycles through periods of keeping the access control either constantly open or constantly closed.
Access Control-Reader
- SAC921 access control supports the Wiegand Reader and RS485 Readers.
- Setup Readers: Reader 1 is set by default as the entry reader, while Reader 2 is set by default as the exit reader.
- Additionally, support is provided for anti-passback functionality for a single door.
- Address: Enter the actual address for the RS485 readers. Support for two RS485 readers is provided.
- Note: The SAC921 supports only one channel of standard Wiegand RFID reader and two channels of Anviz RS485 readers.
Alarm Setup
- Alarm Status: Support the alarm signal input.
- Relay Normal-Open: Upon receiving an alarm signal, the relay switches to a normally open state, for instance in the event of a fire, the door remains open.
- Relay Normal-Close: Upon receiving an alarm signal, the relay switches to a normally closed state, for example in case of theft, the door remains closed.
Period Setting
- Supports setting of 24 time periods, using a 7-day week as a cycle, to configure access control time slots.
Access Control period Group
Set up the access control time group. Each group maximum supports 4 time periods
Access Setup
- Door Sensor : Active Door sensor function
- Relay Output Delay : Setup delay time for door sensor
- Access Remote open door: Open the door with a click of a button.
Advanced Setup—Record List
Check and Search the access control records. And export as a Excel file.
Card
- Set up the RFID Card in the access control system.
- Show Mode : The Card number displayed in the system。 Support the Big Endian 4 Byte, Low Endian 4Byte.
- Identify Mode: Set up the device center to configure the card number information for comparison.
- Notice: Please keep both options with the same mode.
Firmware Upgrade
This interface supports firmware upgrades for devices. Click to select a file and upgrade the firmware.
Initialization
Initialization: Initialize the device. Please proceed with caution, as the initialization will restore all data on the device to factory settings .
Restart
Restart: restart the device without deleting any information.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference,
- this device must accept any interference received, including interference that may cause undesired operation
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with a minimum distance of
20cm between the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>