SANTA-FE 4042960 Smart Aire Power Damper Instruction Manual
- June 13, 2024
- SANTA-FE
Table of Contents
- SANTA-FE 4042960 Smart Aire Power Damper
- Product Usage Instructions
- SAFETY INSTRUCTIONS
- PREPARATION
- DAMPER INSTALLATION
- CONNECTING DUCTS
- DEHUMIDIFIER INSTALLATION
- WIRING DIAGRAM
- DAMPER WIRING
- AHU WIRING
- SET UP
- TESTING
- TROUBLESHOOTING
- USER INFORMATION
- FAQ
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SANTA-FE 4042960 Smart Aire Power Damper
Specifications
- Product Name : SmartAireTM Power Damper
- Manufacturer : Santa Fe Indoor Air Quality Products
- Integration: Compatible with Santa Fe line of Ultra Whole House Ventilating dehumidifiers
- Control : Integrates with dehumidifiers to control ventilation
- Power Source: Requires Class 2 transformer rated 10VA or higher
- Location: Must be mounted at least 3.3 feet (1.0 meter) away from any accessible opening of the duct
Product Usage Instructions
Safety Instructions
READ THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY BEFORE
INSTALLING AND OPERATING THIS DEVICE. PROPER ADHERENCE TO THESE INSTRUCTIONS
IS ESSENTIAL TO OBTAIN MAXIMUM BENEFIT FROM YOUR SANTA FE WHOLE-HOUSE
VENTILATING HUMIDIFIER.
WARNING! THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN SERIOUS INJURY OR DEATH.
CAUTION! THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT IN INJURY OR MATERIAL PROPERTY DAMAGE.
Follow all safety instructions provided in the manual before proceeding with the installation or operation of the SmartAireTMPower Damper.
Preparation
Before beginning the installation process, ensure that you have read and
understood the safety instructions mentioned in the manual. Make sure to have
the necessary tools and equipment ready for the installation process.
Damper Installation
- Identify the appropriate location for mounting the SmartAireTM Power Damper, ensuring it is at least 3.3 feet away from any accessible opening of the duct.
- Turn off the power to the dehumidifier and/or AHU at the service panel before starting the installation.
- Proceed with the installation as per the provided guidelines, ensuring compliance with all applicable codes and standards.
- If cutting or drilling into walls or ceilings is required, take precautions to avoid damage to electrical wiring and hidden utilities.
- Mount the damper securely and power it using a Class 2 transformer rated 10VA or higher.
Scan the QR code for videos on:
- How to install SmartAire™ Power Damper with Santa Fe Ultra70
- How to install SmartAire™ Power Damper with Santa Fe Ultra unit with dedicated ventilation duct
- How to set-up and program SmartAire™ Power Damper
The Santa Fe SmartAire™ Power Damper easily integrates with the Santa Fe line of Ultra Whole House Ventilating dehumidifiers to control the ventilation through the dehumidifier – eliminating the need for an external ventilation controller.
- Serial Number
- Install Date
- Sold By
SAFETY INSTRUCTIONS
READ THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS CARE-FULLY BEFORE INSTALLING AND OPERATING THIS DEVICE. PROPER ADHERENCE TO THESE INSTRUCTIONS IS ESSENTIAL TO OBTAIN MAXIMUM BENEFIT FROM YOUR SANTA FE WHOLE- HOUSE VENTILATING DEHUMIDIFIER.
WARNING
THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT
IN SERIOUS INJURY OR DEATH.
CAUTION
THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. FAILURE TO HEED THEM CAN RESULT
IN INJURY OR MATERIAL PROPERTY DAMAGE.
WARNING!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE
THE FOLLOWING:
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
- Before cleaning this unit, turn off the power to the dehumidifier and/or AHU at service panel.
- This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.
- Installation work must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
- When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
- When cleaning or performing installation of this unit, it is recommended to wear safety glasses and gloves.
- When applicable local regulation comprises more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.
- The unit must be mounted at least 3.3 feet (1.0 meter) away from any accessible opening of the duct.
- Must be powered using a Class 2 transformer rated 10VA or higher.
CAUTION!
- Please read specification label on product for further information and requirements.
- Do not intake air into spaces within walls or ceiling or into attics, crawl spaces, or garage. Do not attempt to recover the exhaust air from a dryer or a range hood.
- Intended for residential installation only in accordance with the requirements of NFPA 90B.
- When leaving the house for a long period of time (more than two weeks), a responsible person should regularly check if the unit operates adequately.
- At least once a year, the unit mechanical and electronic parts should be inspected by qualified service personnel.
- Since the electronic control system of the unit uses a microprocessor, it may not operate correctly because of external noise or very short power failure. If this happens, turn power off at dehumidifier and/or AHU service panel and wait approximately 10 seconds. Then, restore the power to the unit.
- Outdoor intake hood must be weather tight and comprise a bird screen.
- Should you decide to dispose of this unit or of parts of it, do so in accordance with local laws and regulations.
PREPARATION
Before you start:
Choose the best location and installation type for the SmartAire™ Power Damper
according to the current system. Ducting widely affects the performance of
this type of device. Use the shortest, straightest duct run possible to
maximize the results.
CAUTION!
DO NOT INSTALL IN AN AREA WHERE THE TEMPERATURE MAY EXCEED 160°F.
The installer shall ensure that, if necessary, an in-line heater sized
according to the required airflow and outside design heating temperature from
Manual J or ASHRAE table is installed to ensure that the air delivered to the
AHU is never below the minimum temperature allowed by the manufacturer. The
in-line heater shall have an integrated airflow sensor and an over-temperature
sensor to prevent heating in no-flow or low-flow conditions. When deciding if
a preheater is required and whether it should be installed BEFORE or AFTER the
SmartAire™ Power Damper, consider the following:
- The SmartAire™ Power Damper’s minimum operating temperature is -4°F.
- The temperature distributed to the AHU should never be below the temperature recommended by the AHU manufacturer.
- The minimum distance between the preheater and the SmartAire™ Power Damper is 12 inches.
DAMPER INSTALLATION
Always respect the orientation of the SmartAire™ Power Damper and the direction of the airflow, as indicated on the unit.
Direct-to-AHU:
-
Make a 6-inch diameter hole in the return duct of your AHU.
-
Install the seal on the SmartAire™ Power Damper port that will insert the AHU ducting. Make sure that the direction of the airflow indicated on the unit is respected.
-
Install the 3 installation brackets on the unit, as illustrated.
-
Mark and drill holes for the brackets on the AHU ducting and, using appropriate screws, secure the SmartAire™ Power Damper to the duct of the AHU, making sure it is leveled horizontally.
Use self-drilling screws (not included) to avoid marking and drilling steps. -
Follow steps on page 6 to connect the insulated duct to the SmartAire™ Power Damper.
-
Perform the electrical connection to the AHU following the wiring diagrams on pages 8 and 10.
Through a Horizontal Surface:
- Make a hole in the surface that the duct will run through. Size the hole so that the vapor barrier of the insulated ducting is not damaged, and the insulation not compressed.
- Install the 3 installation brackets on the unit, as illustrated.
- Run a piece of insulated duct through the hole and connect to the SmartAire™ Power Damper following the steps on page 6. Make sure the direction of the airflow as indicated on the unit is respected.
- Push the excess ducting on the other side of the surface and, using appropriate screws, secure the SmartAire™ Power Damper to the surface.
- Run the insulated duct to the AHU and connect to the AHU ducting, making sure that the vapor barrier sealing is leak-free.
- Follow steps on page 6 to connect the second insulated duct to the SmartAire™ Power Damper.
- Perform the connections to the AHU following the wiring diagrams on pages 8 and 10.
Mounted Under, Above or Beside a Structure:
- Install 2 installation brackets on the unit, as illustrated, according to the surface the unit will mount to.
- Using appropriate screws, secure the SmartAire™ Power Damper to the structure, making sure it is level horizontally. Make sure the direction of the airflow as indicated on the unit is respected.
- Follow steps on page 6 to connect both insulated ducts to the SmartAire™ Power Damper.
- Run the insulated duct to the AHU and connect to the AHU ducting, making sure that the vapor barrier sealing is leak-free.
- Perform the connections to the AHU following the wiring diagrams on pages 8 and 10.
CONNECTING DUCTS
CAUTION!
ALWAYS USE INSULATED DUCTING OF A MINIMUM R-4 INSULATION FACTOR.
- Slide the inner flexible duct over the port and secure it using a tie wrap.
- Pull the insulation over the flexible duct and port without compressing it.
- Use duct tape to seal the outer membrane of the insulated duct to the outer ring of the port.
WARNING!
MAKE SURE THE OUTDOOR INTAKE HOOD IS AT LEAST 18 INCHES ABOVE THE GROUND
AND 6 FEET AWAY FROM ANY OF THE FOLLOWING: DRYER EXHAUST, HIGH-EFFICIENCY
FURNACE VENT, CENTRAL VACUUM VENT, GAS METER EXHAUST, GAS BARBECUE GRILL, ANY
EXHAUST FROM A COMBUSTION SOURCE, GARBAGE BIN AND ANY OTHER SOURCE OF
CONTAMINATION.
Make sure the outdoor intake hood is easily accessible for annual maintenance. If located above the first floor, place it close to a window or balcony to allow easy access.
DEHUMIDIFIER INSTALLATION
Utilize the Santa Fe dehumidifier fan to provide fresh air ventilation in place of the air handler central fan.
- Dehumidifier fan can operate separately from dehumidifier compressor, allowing ventilation when compressor is not running.
- Dehumidifier compressor and fan will still operate based on humidistat control.
Installation Made Easy
Engineered with the end user in mind, this motorized damper from Santa Fe
offers the ultimate in installation flexibility.
- In-line Installation: Capable of being installed in the conventional in-line configuration, it can be placed on a horizontal surface or suspended beside, below, or above studs and trusses.
- Simple Wiring: A removable terminal block for easier wiring installation.
WIRING DIAGRAM
WARNING!
RISK OF ELECTRIC SHOCK. ELECTRICAL WIRING MUST BE DONE BY QUALIFIED
PERSONNEL IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS. BEFORE
CONNECTING WIRES, SWITCH OFF THE POWER TO THE AHU AT SERVICE PANEL AND LOCK
SERVICE DISCONNECTING MEANS TO PREVENT POWER FROM BEING SWITCHED ON
ACCIDENTALLY.
CAUTION!
FAULTY CONNECTIONS CAN CAUSE DAMAGE TO THE AHU, TO THE THERMOSTAT AND/OR TO
THIS UNIT. ALWAYS DOUBLE CHECK CONNECTIONS BEFORE TURNING POWER BACK ON.
DAMPER WIRING
Wiring the SmartAire™ Power Damper:
Wire according to the below diagram and set integrated switch to Off (I)
AHU WIRING
Synchronize the SmartAire™ Power Damper operation with the heating and cooling run-time to prevent unnecessary central fan operating time (refer to the dotted lines in the diagram).
SET UP
Initial Setup
- Ensure MODE knob is NOT set to Damper adjustment. 1, 2, A, B, C, D, E are OK.
- Ensure Run Time % knob is NOT set to OFF position. 50% is OK.
- Ensure Remote Switch on Terminal Block is in ON position.
- Install wired Terminal Block per diagram on page 9.
- Wait for Damper to run the initialization cycle, approximately 1 minute (fan on, damper open and close, fan will turn off).
Set Damper Open Position
- Install jumper wire between R and Y Terminal (see Figure A). This will turn the fan on and keep the fan on until the jumper wire is removed.
- Rotate MODE dial to “Damper Adjustment” position (all the way counter clockwise).
- Use Run % Knob to adjust the open position of the damper. 100% is fully Open. 20% means the damper is open 20%. Adjust while measuring the CFM until the desire CFM is met.
- Rotate MODE knob to ventilation mode desired (1,2, A, B, C, D, E). See diagram on page 14 for details on each mode.
Set Runtime Percentage
- Ensure MODE knob is not set to “Damper Adjustment”.
- Rotate Run Time % knob to the percentage you want the damper and fan to be on. 100% means continuous ventilation.
IMPORTANT! Remove jumper between R and Y after setup is complete (yellow wire in Figure A).
Now the ventilation will be called per the MODE selected and the run time selected.
TESTING
When powered ON, the SmartAire™ Power Damper performs a 30-second booting sequence followed by a 30-minute period where it stays OFF, but will activate if a heating or cooling call is sent to the AHU.
Blower Door Test (Force the Damper Closed):
If the access to the integrated switch OR to the remote switch (if applicable)
is easy, set the integrated switch OR remote switch to OFF.
If the access to the switch is not easy, such as in an attic:
- Turn OFF the power to the AHU at the service panel.
- Turn the power to the AHU back ON at the service panel.
- Wait 30 seconds for the booting sequence to execute.
- Make sure that the thermostat will not send a heating or cooling call.
- Unit is OFF with its damper closed for 30 minutes, but will activate if a heating or cooling call is sent to the AHU.
Ventilation Test (Forcing the Unit On):
- Turn OFF the power to the AHU at the service panel, and make sure that the integrated or remote switch is set to ON.
- Turn the power back ON at the service panel.
- Wait 30 seconds for the booting sequence to execute.
- Set the thermostat to send a heating or cooling call, or jump R and Y on the terminal block. This will force the ventilation ON for at least 5 minutes.
Testing Function of the SmartAire™ Power Damper:
- Set the integrated switch to ON and either:
- Wait 30 minutes for operation.
- Use a temporary jumper wire to connect R and Y for immediate operation. See yellow wire diagram below.
- The damper should then operate and the Dehumidifier fan should come on.
- Make sure to set integrated switch back to Off (I) after testing.
- Remove jumper wire after test is complete.
TROUBLESHOOTING
A LED indicator is located to the right of the terminal block on the unit and communicates the different states of the unit. Blinking patterns and ways to address them, if applicable, are as follows:
USER INFORMATION
Integrated and Remote Switches:
- This unit is equipped with an integrated ON/OFF switch. For more convenience, your SmartAire™ Power Damper can also be connected to a remote switch.
- To use a remote switch, disconnect the integrated switch and connect the remote switch in the same manner that the integrated one was connected.
User Servicing Instructions:
- Inspect the outdoor air intake at least once a year.
- These recommendations may change according to the environmental conditions in your area.
Comfort Mode:
Should the air inside your house become too humid, or if such conditions want
to be prevented, the operation mode of your SmartAire™ Power Damper can be
changed from a Code-Compliant one (modes 1 and 2) to a Comfort Mode (modes A
to E). Refer to the map below to make the right choice. When making such
change, make sure to only change the Mode and to leave the Run time % as it
was set by your installer. If in doubt, refer to your HVAC contractor.
Santa-Fe-Products.com 800.533.7533
FAQ
Q: Can the SmartAireTM Power Damper be used with other dehumidifiers?
A: The SmartAireTM Power Damper is specifically designed to integrate with the
Santa Fe line of Ultra Whole House Ventilating dehumidifiers. Its
compatibility with other dehumidifiers may vary.
Q: Is professional installation required for setting up the SmartAireTM
Power Damper?
A: Installation work must be done by a qualified person(s) in accordance with
all applicable codes and standards to ensure proper functionality and safety.
Q: How far should the SmartAireTM Power Damper be mounted from duct
openings
A: The unit must be mounted at least 3.3 feet (1.0 meters) away from any
accessible opening of the duct to ensure optimal performance.