FOAMit SP-10N 10 Gallon Spray Unit
Product Information
Specifications
- Model: SP-10N
- Capacity: 10 Gallons
- Maximum Operating Pressure: 100 psi (6.9 bar)
- Language: English
Product Usage Instructions
Safety Precautions
Before using or servicing the unit, please ensure to read and understand all safety instructions provided in the manual:
- Always wear appropriate Personal Protective Equipment (PPE) as indicated in the Safety Data Sheet (SDS).
- Avoid contact with chemical solutions by protecting eyes, skin, and lungs against drifting spray.
- Depressurize and clean the unit after each use to prevent unexpected release of chemical solution.
- Do not operate the unit if damaged or leaking to avoid exposure to chemical solutions.
- Avoid pointing the discharge wand at yourself, others, or objects not intended to be covered with chemicals.
Chemical Handling
When handling chemical solutions, follow these precautions:
- Read and follow all chemical safety precautions and handling instructions provided by the manufacturer and SDS.
- Avoid mixing alkaline with acid to prevent chemical reactions.
- Thoroughly flush the unit with fresh water when switching between alkaline and acid solutions.
Maintenance and Servicing
To ensure proper operation and longevity of the unit:
- Do not service or modify the unit with unauthorized parts.
- Avoid using an air lubricator before the unit to prevent performance issues and damage.
- If needed, install an air dryer before the unit to prevent moisture damage to the pump.
FAQ
- Q: What should I do if I encounter a leak in the unit?
- A: Immediately stop using the unit, depressurize it, and address the leak before continuing use to avoid exposure to chemical solutions.
- Q: Can I use flammable products with this unit?
- A: No, using hydrocarbons or flammable products can lead to explosions, fire, and serious injury. Avoid using such products with this unit.
READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
Scan this code for service manual
Safety
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
- Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and\understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.
- Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the
- Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
- Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
- Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death.
- Always depressurize and clean the unit after each use. Release any remaining air pressure from the unit. Never leave the unit unattended while pressurized.
- Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injuryor death. DO NOT use a solution with a temperature above 100°F (37.8°C).
- Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.
- Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
- Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion,\ serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating the unit.
- Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death.
- Never use hydrocarbons or flammable products with the unit.
- Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to an alkaline.
NOTICE
Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.\ Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an air lubricator before the unit. Moisture in the air lines will damage the pump and diminish the pump life. The air must be filtered, clean, dry andfree of moisture. If needed, install an air dryer before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations
Service Guide
WARNING
Performing any maintenance with the unit pressurized and connected to the air supply may result in serious injury or death. Always ensure that the unit has been depressurized and disconnected from the air supply before conducting any maintenance. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
Maintaining Your Unit
To keep your unit operating properly, periodically perform the following maintenance procedures:
- Inspect the pump for wear and leaks.
- Inspect all hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured.
- Replace the filter located within the air regulator as needed. Clean by unthreading the air regulator bowl from the air regulator.
- Check the suction line and strainer for debris. Clean as needed.
- Drain your air compressor tank on a regular basis\ to help extend pump life. An air source with a high moisture content will accelerate pump wear.
Note: If your air source has a high moisture content, install a water separator to the air fitting on the backplate for more details. (Back plate assembly)
Servicing Your Unit
Most repairs on the unit can be performed with the following tools:
- Crescent wrench (2x)
- ⁷/16 in. (11 mm) open-ended wrench
- Flat head screwdriver
- Thread seal tape
-
2 Phillips head screwdriver
-
3 Phillips head screwdriver
- Hose cutters
- Knife
Troubleshooting Your Unit
If your unit is not operating properly, try using these troubleshooting tips:
Issue | Solution |
---|
Air regulator bowl or air filter has debris such as water, oil, or rust
particles| • Clean by unthreading the air regulator bowl from the air
regulator.
Pump is cycling improperly| • Ensure proper chemicals and concentrations are
being used.
• Check to ensure discharge hose is uncoiled properly, and that there are no kinks that could obstruct fluid flow.
Air passes through the pump without cycling| • The pump needs to be
replaced.
The unit operates at a reduced pressure| • Check suction line and strainer
for debris or damage. Clean or replace as needed. To prevent damage to the
unit, the strainer must always be used.
• Check the air compressor supplying the unit. If the pressure is less than 40 psi (2.8 bar), turn off the unit until the compressor can catch up.
• If the air supply is 50 psi (3.4 bar) or above, check the air gauge, which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust the pressure by turning the knob on the top of the
air regulator.
Tank Assembly
TNKA-10N-BK:
10 gallon natural tank assembly – black* lid – includes drain plug, wheels, suction valve, and backplate thumb nuts
LDA-7BK:
Lid assembly – includes 7 in. black* lid, lid flange, hinge pin, and mounting screws
Item number | Description |
---|---|
1 | LD-PIN |
2 | LD-7BK-LID |
3 | S812-FH |
4 | LD-7BK-FLNG |
Additional colors available, see datasheet for options
Item number | Description |
---|---|
5 | TNK-10N |
6 | DPA |
TNKA-10N-BK:
10-gallon natural tank assembly – black* lid – includes drain plug, wheels, suction valve, and backplate thumb nuts
BPTNA:
Backplate thumb nut assembly – includes bolt, thumb nut, and tether
Item number | Description |
---|---|
1 | BST1420118-VS |
2 | TN1420 |
VLVA-BVPVC34:
Suction valve assembly – includes 3/4 in. PVC valve, bushing, 3/4 in. hose barb elbow, and screw band clamp
Item number | Description |
---|---|
3 | BVPVC34MF |
4 | HHPB3414 |
5 | HBSSEL1438 |
WHLA-AXL14:
10 in. wheel assembly – includes 14 in. axle, axle plate, bolts, washers, and cotter pins
Item number | Description |
---|---|
6 | COT |
7 | PLSS-AXL |
– 2 holes
8| AXL14| Axle – stainless – 0.625 dia. x 14.5 in.
9| B142012-VS| ¼-20 x ½ in. bolt – stainless – truss head Phillips –
Vibra-Seal
10| W10| Wheel – non-marking – 10 in.
11
| ****
FW58
| Flat washer for 5/8 in. od pipe or axle – stainless – 0.64 in. id x 1.2 in. od x 0.05 in. thk
Back Plate Assembly
PA-SP38:
Plate assembly for portable spray and gel units with 3/8 in. hose – Santoprene pump
Additional plate assembly pump options:
- PA-SP38K: Kalrez pump
- PA-SP38V: Viton pump
Item number | Description |
---|
1
| ****
A P56
| Pump with Santoprene seals – includes hose barbs, air fitting, and exhaust
barb
| ****
B P56K
| Pump with Kalrez seals – includes hose barbs, air fitting, and exhaust barb
C P56V
| Pump with Viton seals – includes hose barbs, air fitting, and exhaust barb
2
| ****
R25
| Air regulator – two ¼ in. FPT ports – two ⅛ in. FPT ports – includes filter
and bowl
3| AG100| Air gauge – ⅛ in. NPT – 100 PSI dry model
4| H14BL-F| ¼ in. blue hose – hybrid TPE – available per ft.
5
| ****
FW12NPT
| Flat washer for 1/2 in. NPT – stainless – 0.88 in. id x 1.5 in od x
0.05 in. thk
6| HBFSS1238| Stainless steel hose barb 1/2 FPT x 3/8 barb
7| STR38-IL| In-line strainer – ⅜ barb – EPDM gasket – 20 mesh SS –
black bowl
8| H38BL-F| ⅜ in. blue hose – hybrid TPE – available per ft.
9| SSC38| Stainless screw band clamp for
⅜ in. hose
PA-SP38:
Plate assembly for portable spray and gel units with 3/8 in. hose – Santoprene pump
Additional plate assembly pump options:
- PA-SP38K: Kalrez pump
- PA-SP38V: Viton pump
Item number | Description |
---|---|
1 | SSSFN12 |
2 | SSA14BKH |
¼ NPSM
3| AP14| Air fitting ¼ MPT x plug – nickel-plated brass
4| FW12NPT| Flat washer for 1/2 in. NPT – stainless –
0.88 in. id x 1.5 in. od x 0.05 in. thk
5| HBSS1238| Stainless hose barb ½ MPT x 3/8 barb
Optional Components
WSA-20CFM:
Water separator assembly – 20 CFM – ¼ in. FPT ports – includes air plug and union fittings
Item number | Description |
---|---|
6 | SN1414 |
7 | SSU14 |
8 | WS-20CFM |
9 | AP14 |
Back Plate Sub-assemblies
RGA-R25-PSP:
Air regulator assembly for portable spray and gel units – includes air gauge, pump barb, hose, bulkhead fittings, and air plug
Item number | Description |
---|---|
1 | HBB14P |
2 | EC14 |
3 | H14BL-F |
4 | HBSSEL1814 |
5 | P14-VS |
6
|
R25
| Air regulator – two ¼ in. FPT ports – two ⅛ in. FPT ports – includes filter
and bowl
7| AG100| Air gauge – ⅛ in. NPT – 100 PSI dry model
8| SSA14BKH| Bulkhead adapter – stainless – ¼ NPT x ¼ NPSM
9| SSSFN12| Serrated flange nut – stainless – ½ in.
10| AP14| Air fitting ¼ MPT x plug – nickel- plated brass
Suction Assembly
SCTNA-PF:
Suction assembly for portable spray and gel units – includes suction valve, hose, in-line strainer, and pump hose barb – for Santoprene pump
Additional suction assembly options:
- SCTNA-PFK: Portables with Kalrez pump
- SCTNA-PFV: Portables with Viton pump
Item number | Description |
---|---|
1 | A HB5638 |
B HB5638K | |
C HB5638V | Hose barb for P56V pump – Viton o-ring |
2 | STR38-IL |
black bowl
3| SSC38| Stainless screw band clamp for
⅜ in. hose
4| H38BL-F| ⅜ in. blue hose – hybrid TPE – available per ft.
5| HBSSEL1438| Stainless hose barb ¼ MPT x ⅜ barb elbow
6| HHPB3414| Hex head poly bushing ¾ MPT x ¼ FPT
7| BVPVC34MF| Ball valve – PVC – 3/4 NPT to 3/4 FNPT EPDM seal
Hose Assembly
HA38BL-20:
Hose assembly – 20 ft. of 3/8 in. blue* hose – includes ferruled hose barb
Item number | Description |
---|---|
1 | HBSS1238 |
2 | SSC38 |
3 | H38BL-F |
Additional colors available, see datasheet for options.
Wand Assembly
PSGA384-ST:
Poly spray gun assembly for 3/8 in. hose – includes 4 in. black poly wand, ST2520SS spray tip, hose barb, andscrew band clamp
Item number | Description |
---|---|
1 | ST2520SS |
2 | PW12M14F4 |
long
3
|
PSG12
| Poly spray gun with 2x 1/2 in. straight thread – gray handle with red clip –
316SS internal spring – includes 2x o-ring
4| HBSS1238| Stainless hose barb ½ MPT x 3/8 barb
5| SSC38| Stainless screw band clamp for 3/8 in. hose
Read User Manual Online (PDF format)