WINIX 5500-2 Air Purifier with True Hepa
Product Information
Product Specifications
- Model: [Insert Model Number]
- Dimensions: 12~18 inches (width) x [Height] x [Depth]
- Filters: Pre-Filter, Washable AOCTM Carbon Filter, True HEPA Filter
- Air Purification Stages: 4-Stage Air Purification
Product Usage Instructions
Placement
Place the air purifier indoors away from direct sunlight on a hard, flat
surface with at least 12-18 inches of space between other electronics to avoid
electromagnetic interference. Ensure there is also a minimum of 12-18 inches
of clearance from walls for optimal air flow.
Control Panel Overview
The control panel features indicators for Auto Mode, Sleep Mode, fan speed,
timer settings, filter replacement, light sensor, smart sensor, and air
quality indicator.
Initial Operation
- Remove the front panel carefully to access the filters.
- Take out the Pre-Filter and the other filters from their packaging.
- Install the filters in the correct order (Pre-Filter, Washable AOCTM Carbon Filter, True HEPA Filter).
- Close the front panel securely.
- Plug in the power cord to an electrical outlet.
Maintenance
Regular maintenance is essential for optimal performance:
- Clean the Pre-Filter every 14 days.
- Clean the Washable AOCTM Carbon Filter every 3 months.
- Replace the True HEPA Filter approximately every 12 months.
Replacing Filters
After replacing the True HEPA Filter, reset the filter life by holding down
the Filter Reset Button for at least 5 seconds while the unit is on. The
Filter Replacement Indicator will then disappear.
Frequently Asked Questions (FAQ)
-
Q: How often should I clean the Washable AOCTM Carbon Filter?
A: The Washable AOCTM Carbon Filter should be cleaned every 3 months for optimal performance. -
Q: What should I do if the Air Quality Indicator shows a red light?
A: If the Air Quality Indicator shows red (poor air quality), adjust the fan speed manually or enable Auto Mode for the unit to adjust fan speed based on detected odorous gas levels.
MODEL PART DIAGRAM
WHERE TO USE
-
Allow 12 ~ 18 in. of space between TVs, radios, and other electronics
Electromagnetic interference from certain electronics may cause product malfunction. -
Place indoors away from direct sunlight
Direct exposure may cause product malfunction or failure. -
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal noise and vibrations. -
Allow at least 12 ~ 18 in. from walls for maximum airflow
4-STAGE AIR PURIFICATION
Air Purification means it removes inanimate particles.
CONTROL PANEL
-
Auto Indicator
Indicates whether Auto Mode is enabled or disabled. -
Sleep Indicator
Indicates whether Sleep Mode is enabled or disabled. -
PlasmaWave® Indicator
Indicates whether PlasmaWave® is enabled or disabled. -
Fan Speed Indicator
Indicates the current fan speed. -
Timer Indicator
If the timer has been set, the LED light indicates the set time of operation. -
Filter Replacement Indicator
LED light indicates when it is time to change the filter. -
Light Sensor
Detects the amount of ambient light in the environment. -
Smart Sensor
Detects the amount of odorous gas in the environment. When in Auto mode, the fan speed adjusts according to the detected amount of gas. -
Power Button
- Turns the unit on or off.
- During the first 30 seconds of powering up, the Air Quality Indicator will cycle through Blue, Amber and Red colours. Smart Sensor takes approximately 4 minutes to detect the air quality in the environment before normal operation begins.
-
Mode Button
Press to cycle through to set the mode of operation (Auto, Sleep). The unit will default to Auto with PlasmaWave® enabled when first powered on.- Auto Mode:
- Auto Mode automatically adjusts fan speeds according to your indoor air quality. The fan speed will adjust to low when air quality is good, medium when fair, and to high when poor.
- Sleep Mode:
- Fan speed will automatically be set to a minimum speed (lower than ‘Low’) which will be nearly silent.
- When Sleep Mode is active, PlasmaWave® will be disabled, but it can be turned back on.
-
PlasmaWave® Button
Enables or disables PlasmaWave®.- When the unit is running, you may hear a chirping or buzzing sound. The sound is from particles passing through PlasmaWave®, it is normal and does not signify product failure.
- Press the PlasmaWave® button when the unit is on to enable or disable this feature.
-
Air Quality Indicator
Colour-coded LED light indicates one of three levels of Air Quality: Red (poor), Amber (fair), and Blue (good). -
Fan Speed Button
Enables manual operation of the unit’s fan speeds.- Press to cycle through and set the desired fan speed (Low, Medium, High, Turbo).
-
Timer Button
Press to cycle through and set the desired length of operation (1hr, 4hr, 8hr, [NO TIMER]). -
Filter Reset Button
After replacing the filter, turn on the unit and then use a thin object, such as a paper clip, to press the Filter Reset Button for 5 seconds.
INITIAL OPERATION
- Remove the front panel by grasping its upper edge and gently pulling forward.
- Remove the Pre-Filter, and then the plastic bag of filters behind it.
- Remove filters from a protective plastic bag.
- Install the filters until they fit securely in place.
- 03. True HEPA Filter (back)
- 02. Washable AOC™ Carbon Filter (middle)
- 01. Pre-Filter (front)
- After filters are installed, close the front panel.
- Insert the power cord into an electrical outlet.
MAINTENANCE
When to Replace Filters
Filter
| Indicator Light| When to Service|
When to Replace
---|---|---|---
Pre- Filter| none| Clean once every 14 days| Permanent
Washable AOC™ Carbon Filter|
Check Filter
| * Clean once every 3 months|
Last Approx. 12 months
True HEPA Filter| Can NOT be WASHED
- When the Check Filter Indicator LED is on, it is time to replace the True HEPA Filter and Washable AOC™ Carbon Filter.
- Intervals between filter replacements may vary depending on the environment.
- Use the Washable AOC™ Carbon Filter only when completely dry to avoid unpleasant odours.
- The cleaning cycle of the Washable AOC™ Carbon Filter may vary depending on the usage environment, but it can be cleaned up to four times.
Filter performance may decrease after each wash and depending on the contamination level before washing.
REPLACING FILTERS
Resetting Filter Life:
After replacing your True HEPA Filter, place the Pre-Filter back in and close
the Front Panel. While the unit is on, hold the Filter Reset Button for at
least 5 seconds until you hear the beep. After the beep, the Filter
Replacement Indicator will disappear. Your Winix True HEPA is now reset.
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean the Pre-Filter
- If it is excessively soiled, rinse in room temperature water.
- Do not use detergent or soap.
- Allow the filter to dry for 24 hours or more before using.
- Intervals between filter cleaning may vary depending on the air quality in the environment.
To clean the Washable AOC™ Carbon Filter, remove it from unit and rinse under lightly running room temperature water.
- Do not use detergent or soap. Allow the filter to dry for 24 hours or more before using. Do not use hot water over 104°F.
NOTICE
When cleaning the unit, always unplug the power cord first and then wait until
the unit has cooled down.
Cleaning the Exterior & Interior:
- Open the front panel and clean the interior with a vacuum cleaner.
- A hand vacuum or hose attachment will work best.
- Dampen a cloth with room temperature water and wipe down the interior and exterior of the unit.
- Wipe the unit down with a clean, dry cloth.
- Ensure no moisture remains before plugging the unit back in.
For optimal performance, clean every 1 – 2 months.
- Never disassemble, repair, or modify the unit yourself.
- Do not use flammable sprays or liquid detergents.
- Do not allow children to clean or maintain the unit.
- Before cleaning or maintaining, ensure the unit is unplugged.
SAFETY AND CAUTIONS
Before operating this equipment, carefully read and follow these safety cautions.
-
Ensure filters are inserted before running the unit.
Running the unit without filters can shorten the lifespan of the unit and cause electric shock or injury. -
Be sure foreign objects are NOT inserted into the vents on the unit.
Objects can include pins, rods, and coins. -
Do not touch any part of the interior of the unit with wet hands.
The high voltage may cause electric shock. -
Ensure unit intake and outlet vents do not become blocked.
Blockage may lead to increased internal temperatures causing product failure and deformation. -
Do not use the unit as a step stool or place heavy objects on the unit.
Personal injury may occur or product failure and deformation.
WARNING
Follow these instructions to reduce the risk of serious injury or death and to
reduce the risk of damaging the unit.
- If the power cord is damaged, it must be replaced by a special cord. Reassembly is available from the manufacturer or its service agent.
- This appliance is not intended for use by a person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge of the unit unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- This unit is not intended to be used to preserve documents or art conservation.
- Do not pull on the power cord when unplugging the unit.
- Do not tie or knot the power cord when the unit is in operation.
- If the unit becomes submerged in water, unplug it and contact customer service.
- Do not unplug or move the unit while in operation.
- Do not plug additional appliances into the same outlet or power supply.
- Do not touch the plug with wet hands.
- Unplug the unit when not in operation for extended periods.
- Do not place around heating elements.
- Do not use mist or fumes from industrial oil or around large quantities of metallic dust.
- The cord can become damaged by forcefully bending, pulling, twisting, bundling, pinching or placing heavy objects on it.
- Do not install in any sort of motor or transport vehicle (trucks, boats, ships, etc.).
- Do not place in an area with excessive amounts of noxious gases.
- Do not place near any flammable materials (aerosols, fuel, gases, etc.).
- Do not have the unit facing into wind or drafts.
- Do not place below any electrical outlet.
- Do not place in excessively humid areas where the unit may become wet.
- Do not place the unit closer than 12 inches from the wall during operation. It may cause condensation on the wall and the surrounding area.
SAFETY INSTRUCTIONS
Thank you for purchasing a Winix air purifier. This product is for household use only.
IMPORTANT CAUTIONS FOR USING YOUR AIR PURIFIER:
WARNING:
Follow the instructions in this manual to reduce the risk of electric shock,
short circuit, and/or fire.
- Do not repair or modify the unit yourself.
- All repairs should be completed by a qualified Winix technician.
- The plug for this unit is polarized with one blade wider than the other. Do not force the plug into an electrical outlet. Do not alter the plug in any way. If the plug does not fit into the outlet, reverse the plug. If it still does not fit, contact a qualified technician to install a proper outlet.
- Do not use it if the power cord or plug is damaged or the connection to the wall outlet is loose.
- Use AC 120 V only.
- Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
- Periodically remove dust from the power plug. This will reduce the risk of shock due to humidity build-up.
- Remove the power plug from the outlet before cleaning the unit. When removing the power plug, grasp by holding the plug itself, never hold it by the cord.
- If the power plug is damaged, it must be replaced by the manufacturer or a qualified technician.
- Remove the power plug from the outlet when not in use.
- Do not handle the power plug with wet hands.
- Do not operate the unit when using indoor smoke-generating insecticides.
- Do not clean the unit with benzene or paint thinner. Do not spray insecticides on the unit.
- Do not use the unit where it is humid or where the unit may become wet, such as in the bathroom.
- Do not insert fingers or foreign objects into the air intake or outlet.
- Do not use the unit near flammable gases. Do not use near cigarettes, incense, or other spark-creating items.
- The unit will not remove carbon monoxide emitted from heating appliances or other sources.
IMPORTANT PRECAUTIONS FOR USING YOUR AIR PURIFIER:
- Do not block the intake or outlet vents.
- Do not use near-hot objects, such as a stove.
- Do not use where the unit may come into contact with steam.
- Do not use the unit on its side.
- Keep away from products that generate oily residue, such as a deep fryer.
- Do not use detergent to clean the unit.
- Do not operate without a filter.
- Do not wash and reuse the True HEPA Filter.
- Hold the handle on the back of the unit to transport.
- Do not hold by the front panel.
- Do not stick any small objects into the air outlet vents or fan.
2-YEAR LIMITED WARRANTY
The terms of the limited warranty are as follows:
- This product is manufactured under stringent quality control and inspections.
- The limited warranty will be voided if the product failure is a result of negligence or misuse by the consumer.
- Proof of purchase must be presented upon claiming a limited warranty.
- Store the proof of purchase in a safe place or register your product on winixamerica.com to upload your proof of purchase.
- This limited warranty is valid only in the USA and Canada.
For more information visit https://winixamerica.com/terms-and-conditions/.
Product Name | Air Purifier |
---|---|
Model Name | 5500-2 |
Purchase Date | |
Warranty Period | Two (2) Years |
Place of Purchase | |
Place of Purchase tel. |
Customer
| Address|
Name|
Tel.|
After purchase, be sure to complete all of the above information.
FCC STATEMENT
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, under Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used by the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
UNIT SPECIFICATIONS
Model Name | 5500-2 | Dimensions | 15 in(W) × 8.2 in(D) × 23.6 in(H) |
---|---|---|---|
Power Voltage | AC 120 V / 60 Hz | Weight | 15 lbs |
Power Rate | 70 W | Replacement Filter | Filter H / SKU: 116130 |
Verified Room Size | 360 sq.ft. |
The exterior, design, and product specifications may be changed without prior notice to improve product performance.
The energy efficiency of this ENERGY STAR certified model is measured based on a ratio between the model’s CADR for smoke and the electrical energy it consumes, or CADR/Watt.
Contact Winix for product-related inquiries and customer service
- Dedicated Call Center: ☎ 877-699-4649
- Website: www.winixamerica.com.
To expedite service, please specify the model name and number, the nature of the problem, your contact information, and your address.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>