WINIX HR900 Air Purifier User Manual
- June 3, 2024
- WINIX
Table of Contents
- WINIX HR900 Air Purifier User Manual
- SPECIFICATIONS
- MODEL PART DIAGRAM
- WHERE TO USE
- 5-STAGE AIR PURIFICATION
- INSTALLING THE PET FILTER
- INITIAL OPERATION
- REPLACING FILTERS
- CONTROL PANEL
- MAINTENANCE
- CLEANING CARE
- SAFETY AND CAUTIONS
- SAFETY INSTRUCTIONS
- TWO YEARS WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WINIX HR900 Air Purifier User Manual
HR900
SPECIFICATIONS
MODEL PART DIAGRAM
WHERE TO USE
Allow 12 ~ 18 in. of space between TVs, radios, and other electronics
Electromagnetic interference from certain electronics may cause product
malfunction.
Place indoors away from direct sunlight
Direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal noise and vibrations.
Allow at least 12 ~ 18 in. from walls for maximum air flow
5-STAGE AIR PURIFICATION
Air Purification means it removes inanimate particles
INSTALLING THE PET FILTER
For optimal performance, only genuine Winix filters should be used with your Winix Air Purifier
- Remove the front panel by grasping the upper edges and gently pulling the front panel toward yourself. The latch at the lower edge of the panel must be released from its position.
- Press the tabs on the top edge of the Pre-Filter to remove it.
- Remove the liner around the outside of the Pre-Filter to reveal the adhesive tape.
- Attach the Pet Filter to the front of the Pre-Filter. Press the adhesive tape around the edge of the Pet Filter to adhere it to the Pet Filter.
- Insert the Pre-Filter. Insert the bottom tabs into the slots on both sides of the lower part of the unit. Rotate the top of the filter upward and snap the upper tabs into the slots securing the Pre-Filter in place.
- Replace the front panel by first inserting the latch at the bottom edge into the base of the unit, then rotate the panel upward toward the top of the unit until it magnetically snaps closed.
Filter Replacement Period
www.winixamerica.com l info@winixinc.com
INITIAL OPERATION
-
Remove the front panel by grasping its upper edge and gently pulling forward.
-
Remove the Pre-Filter, then the plastic bag of filters behind it.
-
Remove filters from protective plastic bag.
-
Install the filters until they fit securely in place.
04. True HEPA Filter (back)
03. Washable AOC™ Carbon Filter (middle)
02. Pre-Filter (front) -
After filters are installed, close the front panel.
-
Insert the power cord into an electrical outlet.
REPLACING FILTERS
CONTROL PANEL
01. Smart Sensor
Detects the amount of odorous gas in the environment. When in Auto mode, the
fan speed adjusts according to the detected amount of gas.
0 2. Filter Replacement Indicator
LED light indicates when it is time to change the filter.
03. Filter Reset Button
After replacing the filters, turn the unit on and use a thin object, such as a
paper clip, to press the Filter Reset Button for 5 seconds.
04. Fan Speed Indicator
Indicates the current fan speed.
05. PlasmaWave® Indicator
Indicates whether PlasmaWave® is enabled or disabled.
06. Timer Indicator
If timer has been set, the LED light indicates the set time of operation.
07. Child Lock Indicator
LED light indicates whether Child Lock Mode is enabled or disabled.
08. Light Sensor
Detects the amount of ambient light in the environment.
09. Power Button
Turns the unit on or off.
• During the first 4 minutes of powering up, the Air Quality light will flash
as the Smart Sensors measure the air quality in the environment, after which
normal detect will begin.
10. Mode Button
Press to cycle through to set the mode of operation (Auto, Sleep). The unit
will default to Auto with PlasmaWave® enabled when first powered on.
Auto Mode:
• Auto Mode automatically adjusts fan speeds according to your indoor air
quality. The fan speed will adjust to low when air quality is good, medium
when fair, and to high when poor.
Sleep Mode:
- When Sleep Mode is activated, the Air Quality Indicator LED light is disabled.
- Fan speed will automatically set to minimum speed (lower than ‘Low’) which will be nearly silent.
- When Sleep Mode is active, PlasmaWave® will be disabled, but it can be turned back on.
Manual Mode (Setting fan speed):
Users can opt to manually set the fan speed to Low, Medium, High, or Turbo.
- Press the Mode Button to select the desired fan speed.
- The Mode LED light will indicate the selected fan speed and operation will begin.
11. PlasmaWave® Button
Enables or disables PlasmaWave®.
- Press the PlasmaWave® button when the unit is on to enable or disable this feature.
- PlasmaWave® works to remove harmful airborne contaminants.
“When the unit is running, you may hear a chirping or buzzing sound. The sound is from large particles passing through PlasmaWave®, it is normal and does not signify product failure.”
12. Timer Button & Air Quality LED Light
- Press to cycle through and set desired length of operation. (1hr, 4hr, 8hr, [NO TIMER])
- To turn the Air Quality LED light on or off, press and hold the Timer Button for 3 seconds.
- When on, the LED light will indicate the current indoor air quality according to three levels. BLUE(good), AMBER (fair), RED (poor).
13. Child Lock
Press and hold the Child Lock Button for 3 seconds to enable or disable the
feature.
- When the Child Lock indicator is lit, the feature is enabled.
- When Child Lock is enabled, the control panel is locked and the settings cannot be changed.
- To disable, press and hold the Child Lock Button again for 3 seconds.
MAINTENANCE
When to Replace Filters
- When the Check Filter Indicator LED is on, it is time to replace the True HEPA Filter and Washable AOC™ Carbon Filter.
- Intervals between filter replacement may vary depending on environment.
- Filter performance may decrease after each wash and depending on contamination level prior to washing.
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean the Pre-Filter
- If it is excessively soiled, rinse in room temperature water.
- Do not use detergent or soap.
- Allow the filter to dry for 24 hours or more before using.
- Intervals between filter cleaning may vary depending on the air quality in the environment.
To clean the Washable AOCTM Carbon Filter, remove from unit and rinse under lightly running room temperature water.
- Do not use detergent or soap.
- Allow the filter to dry for 24 hours or more before using.
- Do not use hot water over 104 oF.
Cleaning the Smart Sensor:
-
Use a damp cotton swab to wipe the lens and intake area of the Smart Sensor.
• To clean the sensor area, use only water. Do not use volatile substances such as alcohol or acetone. -
Wipe away any remaining moisture with a dry cotton swab.
Cleaning the Exterior & Interior:
-
Open the front panel and clean the interior with a vacuum cleaner.
• A handheld vacuum or hose attachment will work best. -
Dampen a cloth with room temperature water and wipe down the interior and exterior of the unit.
-
Wipe the unit down with a clean, dry cloth.
• Ensure no moisture remains before plugging the unit back in.
- For optimal performance, clean every 1 – 2 months.
NOT I C E
- When cleaning the unit, always unplug the power cord first and then wait until the unit has cooled down.
- Never disassemble, repair, or modify the unit yourself.
- Do not use flammable sprays or liquid detergents.
- Do not allow children to clean or maintain the unit.
- Before cleaning or maintaining, ensure unit is unplugged.
- Do not use benzene, alcohol, or other volatile fluids, which may cause damage or discoloration.
SAFETY AND CAUTIONS
- Before operating this equipment, carefully read and follow these safety cautions.
- Ensure filters are inserted before running unit.
- Running the unit without filters can shorten the lifespan of the unit and cause electric shock or injury.
- Be sure foreign objects are NOT inserted into the vents on the unit.
- Objects can include pins, rods, and coins.
- Do not touch any part of the interior of the unit with wet hands.
- The high voltage may cause electric shock.
- Ensure unit intake and outlet vents do not become blocked.
- Blockage may lead to increased internal termperatures, causing product failure and deformation.
- Do not use the unit as a step stool or place heavy objects on the unit.
- Personal injury may occur or product failure and deformation.
WARNING
Follow these instructions to reduce the risk of serious injury or death and to
reduce risk of damaging the unit.
- If the power cord is damaged, it must be replaced by a special cord. Reassembly is available from the manufacturer or its service agent.
- This appliance is not intended for use by a person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge of the unit, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- This unit is not intended to be used to preserve documents or art conservation.
Do not pull on the power cord when unplugging the unit.
Do not tie or knot the power cord when unit is in operation.
If the unit becomes submerged in water, unplug it and contact customer
service.
Do not unplug or move the unit while in operation.
Do not plug additional appliances into the same outlet or power supply.
Do not touch the plug with wet hands.
Unplug the unit when not in operation for extended periods of time.
Do not place around heating elements.
Do not use around mist or fumes from industrial oil or around large quantities
of metallic dust.
The cord can become damaged by forcefully bending, pulling, twisting,
bundling, pinching or placing heavy objects on it.
Do not install in any sort of motor or transport vehicle (trucks, boats,
ships, etc.).
Do not place in an area with excessive amounts of noxious gases.
Do not place near any flammable materials (aerosols, fuel, gases, etc.).
Do not have the unit facing into wind or drafts.
Do not place below any electrical outlet.
Do not place in excessively humid areas where the unit may become wet.
Do not place unit closer than 12 inches from the wall during operation. It may
cause condensation on the wall and the surrounding area.
SAFETY INSTRUCTIONS
Thank you for purchasing a Winix air purifier. This product is for household use only.
IMPORTANT CAUTIONS FOR USING YOUR AIR PURIFIER:
WARNING: Follow the instructions in this manual to reduce the risk of electric
shock, short circuit, and/or fire.
-
Do not repair or modify the unit yourself.
-
All repairs should be completed by a qualified Winix technician.
-
The plug for this unit is polarized with one blade wider than the other. Do not force the plug into an electrical outlet. Do not alter the plug in any way. If the plug does not fit into the outlet, reverse the plug. If it still does not fit, contact a qualified technician to install a proper outlet.
-
Do not use if the power cord or plug is damaged or the connection to the wall outlet is loose.
-
Use AC 120 V only.
-
Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
-
Periodically remove dust from the power plug. This will reduce the risk of shock due to humidity build up.
-
Remove the power plug from the outlet before cleaning the unit. When removing the power plug, grasp by holding the plug itself, never hold by the cord.
-
If the power plug is damaged, it must be replaced by the manufacturer or a qualified technician.
-
Remove the power plug from the outlet when not in use.
-
Do not handle the power plug with wet hands.
-
Do not operate the unit when using indoor smoke-generating insecticides.
-
Do not clean unit with benzene or paint thinner. Do not spray insecticides on the unit.
-
Do not use the unit where it is humid or where the unit may become wet, such as the bathroom.
-
Do not insert fingers or foreign objects into air intake or outlet.
-
Do not use the unit near flammable gases.
Do not use near cigarettes, incense, or other spark-creating items. -
Unit will not remove carbon monoxide emitted from heating appliances or other sources.
IMPORTANT PRECAUTIONS FOR USING YOUR AIR PURIFIER:
- Do not block the intake or outlet vents.
- Do not use near hot objects, such as a stove.
- Do not use where the unit may come into contact with steam.
- Do not use the unit on its side.
- Keep away from products that generate oily residue, such as a deep fryer.
- Do not use detergent to clean the unit.
- Do not operate without a filter.
- Do not wash and reuse the True HEPA Filter or the Carbon Filter.
- Hold the handle on the back of the unit to transport.
- Do not hold by the front panel.
- Do not stick any small objects into the air outlet vents or fan.
TWO YEARS WARRANTY
The terms of the warranty are as follows:
- This product is manufactured under stringent quality control and inspections.
- The warranty will be voided if product failure is a result of negligence or misuse by the consumer.
- A proof of purchase must be presented upon claiming a Product Warranty.
- Store the proof of purchase in a safe place or register your product on winixamerica.com to upload your proof of purchase
- This warranty is valid only in the USA and Canada.
- for more information visit
https://winixamerica.com/terms-and-conditions/
After purchase, be sure to complete all of the above information.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Read More About This Manual & Download PDF:
References
- Winix Air Purifiers - Healthy Home Appliances - Improve Your Indoor Air Quality
- Winix Air Purifiers - Healthy Home Appliances - Improve Your Indoor Air Quality
- Terms and Conditions - Warranty, Returns, Exchanges - Winix America Inc
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>