Installation Instructions
Remove the mounting plate [A] from the canopy [D] by unscrewing the mounting screws [E]. Retain mounting screws for later use.
- Wrap ground wire from the outlet box around the green ground screw and thread into the hole provided on the mounting plate.
- Attach ground wire from the outlet box under the cupped washer and green ground screw, then thread into the mounting plate. Connect fixture ground wire to outlet box ground wire using a wire connector after completing the steps.
- Refer to the chart provided for correct wire connections. Connect Black or Red Supply Wire to Black, and White Supply Wire to White as instructed.
- Push canopy [D] against the wall, aligning the mounting screw holes in the mounting plate with those in the canopy. Secure by screwing two mounting screws [E] into the holes.
Glass Shade Installation
- Carefully rotate the glass shade into the fixture clockwise until snug. Do not over-tighten. Repeat for any remaining glass shades.
FAQ
- Q: Where can I find warranty information for the product?
- A: For warranty information, please visit kichler.com/warranty or contact 866-558-5706 during business hours (M-F 9 am to 5pm EST).
FIXTURE DIAGRAM
PARTS LIST
- [A] Mounting Plate
- [B] Outlet Box (not supplied)
- [C] Plate Mounting Screw (2)
- [D] Canopy
- [E] Mounting Screw (2)
- [F] Glass Shade (2
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before
starting and during the installation.
WARNING
- This fixture is intended for installation under the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
DIMMING
- This LED fixture is compatible with most standard incandescent dimmers, LED dimmers, and electronic low-voltage dimmers.
- For optimal performance, an electronic low-voltage dimmer should be used.
- See kichler.com/dimming for a list of compatible dimmers.
CLEANING
- Always be certain that the electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION INSTRUCTIONS
-
Remove the mounting plate[A] from the canopy[D] by unscrewing mounting screws[E]. Retain mounting screws.
-
Attach the mounting plate[A] to the outlet box[B] using the plate mounting screws[C].
NOTE: The mounting plate should be installed with the flat side of the mounting plate against the wall.
NOTE: This fixture can be installed vertically or horizontally.
For VERTICAL installation, the mounting plate should be installed with the mounting screw holes (in the bent flanges at the outer edge of the mounting plate) at the 12 and 6 o’clock position.
For HORIZONTAL installation, the mounting plate should be installed with the mounting screw holes (in the bent flanges at the outer edge of the mounting plate) at the 9 and 3 o’clock position. -
Grounding instructions: (See Illus. a or b).
- On fixtures where the mounting plate is provided with a hole and two raised dimples, wrap ground wire from the outlet box around the green ground screw, and thread it into the hole.
- On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread into the mounting plate.
If the fixture is provided with ground wire, connect the fixture ground wire to the outlet box ground wire with a wire connector after following the above steps. Never connect ground wire to black or white power supply wires .
-
Push canopy[D] to the wall, carefully aligning the mounting screw holes in the mounting plate with the mounting screw holes in the canopy.
Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
*Note: When parallel wire (SPT 1 & SPT 2) is used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|
NOTE: Make sure all wires are inside the canopy and do not get pinched between the mounting plate and canopy or wall and canopy of the fixture.
-
Screw two (2) mounting screws[E] into holes in the canopy and mounting plate to attach the fixture to the wall. Tighten to secure.
NOTE: For VERTICAL installation, install one (1) at the top and one (1) at the bottom of the canopy. For HORIZONTAL installation, install one (1) on the left side and one (1) on the right side of the canopy. -
Carefully rotate the glass shade into the fixture (clockwise) until snug. DO NOT OVERTIGHTEN. Repeat for the remaining glass shade.
FCC STATEMENT
FCC INFORMATION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CONTACT
- © 2023 Kichler Lighting LLC. All rights reserved.
- For warranty information please visit: kichler.com/warranty.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>