Wall Switch is a wireless indoor power relay featuring a power consumption meter. The miniature body of the device is adapted for installation in a European-type socket.

Regardless of the type of electrical circuit, only a qualfiied electrician should install Wall Switch!

Wall Switch operates only within the Ajax security system (integration into third party security systems is not provided), communicating with a https://ajax.systems/products/#block2 via the protected Jeweler protocol. The communication range is up to 1,000 meters in the line of sight.

Use scenarios to program actions of https://ajax.systems/products/#block9 (Relay, Wall Switch, or Socket) in response to an alarm, Button press, or schedule. A scenario can be created remotely in the Ajax app.

How to create and configure a scenario in the Ajax security system

The Ajax security system can be connected to the central monitoring station of a security company.

Buy power relay Wall Switch

Functional Elements

Functional Elements

  1. Antenna
  2. Terminal blocks
  3. Functional button
  4. Light indicator

IN terminals:

  • L terminal — power supply phase terminal.
  • N terminal — power supply neutral terminal.

OUT terminals:

  • N terminal — connected device neutral output contact terminal.
  • L terminal — connected device phase output contact terminal.
    Functional Elements

Operating Principle

Wall Switch input terminals are connected to the grid, and the output terminals are connected to the socket or electrical appliance/system. Wall Switch closes/opens the electric circuit, controlling the power supply by the command of the security system user through the Ajax app . The state of Wall Switch contacts can be switched manually: by holding the function button for 2 seconds. To make Wall Switch react to alarm or schedule automatically, you can configure a scenario.

Wall Switch features a protection system against voltage surge beyond the range of 184V – 253V or overcurrent above 13А. In this case, the power supply is interrupted, resuming after normalizing the voltage and current values.

The maximum resistive load on the relay is 3 kW.
You can check the power usage by the electrical appliance connected via Wall Switch through the app. There is a power consumption meter.

Wall Switch, with rewire version 5.54.1.0 and higher, can operate in pulse or biostable mode. With this rewire version, you can also select the normal relay contact state:

  • Normally closed (NC) — the contacts open when the relay is activated and closed when the relay is inactive.
  • Normally open (NO) — the contacts close when the relay is activated and open when the relay is inactive.

Wall Switch, with rewire version below 5.54.1.0, only works in biostable mode with a normally open contact.

How to find out firmware version of the device?

Note icon  At low loads (up to 25 W), current and power consumption indications may be displayed incorrectly due to hardware limitations.

Connecting to the hub

Before connecting the device:

  1. Switch on the hub and check its Internet connection (the logo glows white or green).
  2.  Install the Ajax app . Create the account, add the hub to the app, and create at least one room.
  3. Make sure that the hub is not armed, and it does not update by checking its status in the Ajax app.

Only users with administrator rights can add a device to the app.

To pair Wall Switch with the hub:

  1. Click Add device in the Ajax app.

  2. Name the device, scan it, or enter the QR code manually (located on the case and packaging), select the room.
    Connection instruction

  3. Click Add — the countdown will begin.

  4. Press the functional button. If you can’t do this (the device is mounted in the wall), give Wall Switch at least 20 W load for ve seconds (by connecting and disconnecting a working kettle or lamp).

Note icon For detection and pairing to occur, the device should be located in the coverage area of the hub’s wireless network (at the same object). The connection request is transmitted only at the moment of switching on the device.

If the device failed to pair, wait 30 seconds and then retry. Wall Switch will appear in the list of hub devices.
The device statuses update depends on the ping interval set in the hub settings.
The default value is 36 seconds.

Note icon When switching on for the first time, Wall Switch contacts are open! When deleting Wall Switch from the system, contacts open!

States
  1. Devices
  2. Wall Switch
Parameter Value
Jeweller Signal Strength Signal strength between hub and device
Connection Connection status between hub and device
Routed Through ReX Displays the status of using the ReX range extender
Active State of the relay (switched on/off)
Voltage The input voltage of WallSwitch
Current The input current of WallSwitch
Power Current consumption in W
Electric energy consumed The electric power consumed by the device connected

to the relay. The counter is reset when the relay loses the power supply
Temporary deactivation| Displays the status of the device: active or completely disabled by the user
Firmware| Device firmware version
Device ID| Device identifier

Settings
  1. Devices
  2. Wall Switch
  3. Settings
Setting Value
First field Device name, can be edited

Room

| Selecting the virtual room to which the device is assigned

Relay Mode

| Selecting relay operation mode:

  • Pulse — when activated, Wall Switch generates a pulse of a given duration
  • Bastable **** — Wall Switch, when activated, changes the state of contacts to the opposite

Settings are available with firmware version
5.54.1.0 and higher

Contact status| Normal contact state

  • Normally closed
  • Normally open

Pulse duration| Selecting the pulse duration in the pulse mode:
From 0.5 to 255 seconds
Current protection| If active, power supply will be switched off if current exceeds 13 A, in the inactive state the threshold is 19,8 A (or 16 A, if continues for 5 seconds)

Voltage protection

| If active, power supply will be switched off in case of a voltage surge beyond the range of 184 – 253 V, in the inactive state — 0 – 500 V
Scenarios| Opens the menu for creating and configuring scenarios
 |
Jeweler Signal Strength Test| Switches the device to the Jeweler signal strength test mode
User Manual| Opens the Wall Switch User Manual
Temporary deactivation| Allows the user to deactivate the device without removing it from the system. The device will not execute system commands and participate in automation scenarios. All notifications and alarms of the device will be ignored

Please note that deactivated device will save it’s current state (active or inactive)

Unpair Device| Disconnects the relay from the hub and deletes its settings

Indication

The Wall Switch light indicator can light green depending on the device status.
When not paired with the hub, the light indicator blinks periodically. When the functional button is pressed, the light indicator lights up.

Functionality testing

The Ajax security system allows conducting tests for checking the functionality of connected devices.
The tests do not start immediately but within a period of 36 seconds when using default settings. The test time start depends on the settings of the detector ping interval (the Jeweler menu in the hub settings

Jeweler Signal Strength Test

Installation of the Device

Regardless of the type of electrical circuit, only a quailed electrician should install Wall Switch!

Wall Switch is designed for installation inside a socket box with the diameter 50 mm and more and the depth no less than 70 mm. The relay can also be installed within extension cords and other circuits powered by 230 V.

The communication range with the hub in the line of sight is up to 1,000 meters.
Take this into account when choosing the location for Wall Switch.

If the device has a low or unstable signal strength, use the ReX radio signal range extender

Installation process:

  1. De-energize the cable to which Wall Switch will be connected.

  2. Connect the grid wire to the Wall Switch terminals according to the following scheme:
    Installation process

  3. Connect a socket using bundled connecting wires or an electrical appliance using a wire with the scent cross-section to Wall Switch. It’s recommended to use wires with a cross-section of 1.5 – 2 mm²

Do not connect more than 3 kW load to Wall Switch. When connecting the load, strictly observe the connection diagram since an incorrect connection may cause the device to malfunction and/or damage the property.

When installing Wall Switch in the box, lead out the antenna and place it under the plastic frame of the socket. The bigger the distance between the antenna and metal structures, the lower the risk of interfering (and impairment) of the radio signal.

  1. recommended antenna location
    Recommended antenna location

 Do not shorten the antenna! Its length is optimal for operation within the used radio frequency range

During the installation and operation of Wall Switch, follow the general electrical safety rules and the requirements of electrical safety regulatory acts.

 It is strictly forbidden to disassemble the device. Do not use the device with damaged power cables.

Do not install the relay:

  1. Outdoors.
  2. In metal wiring boxes and electrical panels.
  3. In places with temperature and humidity exceeding the permissible limits.
  4. Closer than 1 m to a hub.

Maintenance

The device does not require maintenance.

Tech specs

Actuating element Electromagnetic relay
The service life of the relay 200,000 switching-ons
Supply voltage 110 – 230 V AC ± 10% 50/60 Hz
Voltage protection For 230 V mains: max — 253 V, min — 184 V For 110 V mains:

max — 126 V, min — 77 V
Maximum load current| 13 А
Maximum current protection| Yes, 13 A
Power output (resistance load 230 V)| Up to 3 kW
Operating modes| Pulse and bistable (firmware version is
5.54.1.0 or higher. Manufacture date from March 5, 2020)
Only bistable (firmware version is lower than 5.54.1.0)
Pulse duration| 0.5 to 255 seconds (firmware version is 5.54.1.0 or higher)
Electricity meter function| Yes
Power consumption| Yes: current, voltage,
parameters control| consumed power
The power consumption of the device in the standby mode| Less than 1 W⋅h
Frequency band| 868.0 – 868.6 MHz or 868.7 – 869.2 MHz
depending on the region of sale
Compatibility| Operates with all Ajax hubs, and range extenders
Maximum RF output power| Up to 25 mW
Modulation| GFSK
Radio signal range| Up to 1,000 m (any obstacles absent)
Shell protection rating| IP20
Operating temperature range| From 0°С to +64°С
Maximum temperature protection| Yes, 65°C
Operating humidity| Up to 75%
Overall dimensions| 39 × 33 × 18 mm
Weight| 30 g

Complete Set

  1. WallSwitch
  2. Connecting wires — 2 pcs
  3. User Manual

References