Unmanaged Desktop PoE Switch
Switches Explanation
Extend (1–4) (for TL-SF1008LP/TL-SF1008P)
Off: Port 1–4 run at 10/100 Mbps and support PoE power supply up to 100 m
away.
On: Port 1–4 run at 10 Mbps and support PoE power supply up to 250 m away.
Priority (1–2)/Priority (except TL-SL1210MP)
Off: All the ports transmit data with the same priority.
On/On (1-2): Port 1–2 transmit data with a higher priority than other ports.
Extend (for TL-SF1009P and TL-SL1210MP)
Off: Port 1–8 run at 10/100 Mbps and support PoE power supply up to 100 m
away.
On (1-4): Port 1–4 run at 10 Mbps and support PoE power supply up to 250 m
away.
On (1-8): Port 1–8 run at 10 Mbps and support PoE power supply up to 250 m
away.
Isolation (for TL-SF1009P and TL-SL1210MP)
Off: Port 1–8 can transmit data with every port.
On (1-8): Port 1–8 cannot transmit data with each other. They can transmit
data only with the uplink port.
LED Explanation
Power
On: Power on
Off: Power off
PoE Status
Port 1–4 (for TL-SF1008LP/TL-SF1008P)/
Port 1–8 (for TL-SF1009P/TL-SL1210MP)
On: PoE power provided
Flashing: Current-overload/ Short-circuit
Off: No PoE power provided
Link/Act
Port 1–8/Port 1–9 (for TL-SF1009P)/
Uplink 1, Uplink2 (for TL-SL1210MP)
On: Link present but no activity
Flashing: Transmitting/receiving data
Off: No link
PoE MAX
TL-SF1008LP
On: 34 W ≤ Total power supply < 41 W
Flashing: Total power supply = 41 W
Off: Total power supply < 34 W TL-SF1008P
On: 59 W ≤ Total power supply < 66 W
Flashing: Total power supply = 66 W
Off: Total power supply < 59 W TL-SF1009P
On: 58 W ≤ Total power supply < 65 W
Flashing: Total power supply = 65 W
Off: Total power supply < 58 W TL-SL1210MP
On: 117 W ≤ Total power supply < 124 W
Flashing: Total power supply = 124 W
Off: Total power supply < 117 W
Note : For simplicity, we will take TL-SF1008P for example throughout the Guide.
Connection
Note :
-
TL-SL1210MP has two uplink ports, which typically connect to uplink devices like routers.
Uplink 1 is an SFP port and works with a 1000 Mbps SFP module. Uplink 2 is an RJ45 port. -
PoE ports can also connect to non-PoE devices, but only transmit data.
-
TL-SF1008LP can supply up to 15.4 W for each PoE port and 41 W for all PoE ports.
TL-SF1008P can supply up to 30 W for each PoE port and 66 W for all PoE ports.
TL-SF1009P can supply up to 30 W for each PoE port and 65 W for all PoE ports.
TL-SL1210MP can supply up to 30 W for each PoE port and 124 W for all PoE ports.
Frequently Asked Questions (FAQ)
Q1. The Power LED is not lit.
The Power LED should be lit when the power system is working normally. If the
Power LED is not lit, please check as follows:
A1: Make sure the AC power cord is connected the switch with power source
properly.
A2: Make sure the voltage of the power supply meets the requirements of the
input voltage of the switch.
A3: Make sure the power source is on.
Q2. The Link/Act LED is not lit when a device is connected to the corresponding port.
It is recommended that you check the following items:
A1: Make sure that the cable connectors are firmly plugged into the switch and
the device.
A2: Make sure the connected device is turned on and working well.
A3: The cable must be less than 100 meters long (328 feet). If Extend Mode is
enabled, it should be less than 250 meters (820 feet).
Q3. Why are PoE ports not supplying power for PoE devices?
When the total power consumption of connected PoE devices exceeds the maximum,
the PoE port with a smaller port number has a higher priority. The system will
cut off power to the ports with larger port numbers to ensure supplying to
other ports.
Take TL-SF1008P as an example. If port 1, 2, and 4 are consuming 15.4 W
respectively, and an additional PoE device with 20 W is inserted to port 3,
the system will cut off the power of port 4 to compensate for the overload.
Specifications
General Specifications
Standard| IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3af,
IEEE802.3at (Except TL-SF1008LP)
IEEE 802.3ab (Only for TL-SL1210MP)
IEEE 802.3z (Only for TL-SL1210MP)
---|---
Protocol| CSMA/CD
Interface| TL-SF1008LP/TL-SF1008P:
8 10/100 Mbps RJ45 Ports
Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–4
TL-SF1009P:
9 10/100 Mbps RJ45 Ports
Auto-Negotiation/Auto MDI/MDIX
PoE Ports: Port 1–8
TL-SL1210MP:
8 10/100 Mbps RJ45 Ports
Auto-Negotiation/Auto MDI/MDIX
1 10/100/1000 Mbps RJ45 Port
1 1000 Mpbs SFP Port
PoE Ports: Port 1–8
Network Media (Cable)| 10BASE-T:
UTP category 3, 4, 5 cable (maximum 100 m)
EIA/TIA-568 100Ω STP (maximum 100 m)
100BASE-TX:
UTP category 5, 5e cable (maximum 100 m)
EIA/TIA-568 100Ω STP (maximum 100 m)
1000BASE-T (Only for TL-SL1210MP):
UPT category 5e cable or above (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100 m)
1000BASE-SX/LX/LX10/BX10 (Only for TL-SL1210MP):
MMF, SMF
Switching Capacity| TL-SF1008LP/TL-SF1008P: 1.6 Gbps
TL-SF1009P: 1.8 Gbps
TL-SL1210MP: 5.6 Gbps
MAC Address Table| 2K
Transfer Method| Store-and-Forward
MAC Address Learning| Automatically learning, automatically aging
Power Supply| External Power Adapter
Input: 100-240 VAC, 50/60 Hz
Output:
TL-SF1008LP: 53.5 VDC/0.81 A
TL-SF1008P/TL-SF1009P: 53.5 VDC/1.31 A
TL-SL1210MP: 53.5 VDC/2.43 A
Wall Mountable| Yes
Distance Between
Mounting Holes| TL-SF1008LP/TL-SF1008P/TL-SF1009P: 105 mm
TL-SL1210MP: 150 mm
|
Environmental and Physical Specifications
Certificatio | FCC, CE, RoHS |
---|---|
Operating Temperature | 0˚C to 40˚C (32˚F to 104˚F) |
Storage Temperature | -40˚C to 70˚C (-40˚F to 158˚F) |
Operating Humidity | 10% to 90% non-condensing |
Storage Humidity | 5% to 90% non-condensing |
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
For technical support and other information, please visit https://www.tp-
link.com/support, or simply scan the QR code.
If you have any suggestions or needs on the product guides, welcome to email
techwriter@tp-link.com.cn.
http://www.tp-link.com/support
PoE Disclaimer
The speed of the ports in extend mode will downgrade to 10 Mbps. The actual
transmission distance may vary due to power consumption of PoE-powered
devices or the cable quality and type.
PoE budget calculations are based on laboratory testing. Actual PoE power
budget is not guaranteed and will vary as a result of client limitations and
environmental factors.
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of directives 2014/30/EU,
2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-
link.com/en/ce.
Safety Information
- Keep the device away from water, fire, humidity or hot environments.
- Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
- Do not use damaged charger or USB cable to charge the device.
- Do not use any other chargers than those recommended.
- Adapter shall be installed near the equipment and shall be easily accessible.
- Place the device with its bottom surface downward.