Wireless Z-Wave Vision siren powered AC / DC with backup battery Instruction Manual
- June 7, 2024
- VISION
Table of Contents
Wireless Z-Wave Vision siren powered AC / DC with backup battery
Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instruction, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try and correct the interference by one of the
following measures:
– Reorient or relocate the receiving antenna,
– Increase the separation between the equipment and receiver,
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help. This device
complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that
may cause undesired operation. FCC Caution: Any changes or modifications not
expressly approved by the party responsible for compliance could void the
user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless siren & strobe alarm is free from
physical defects in material and workmanship under normal usage for one year
from the date of purchase. If the product proves defective during this one-
year warranty period, Vision will replace it free of charge. Vision does not
issue any refunds. This warranty is extended to the original end-user
purchaser only and is not transferable. This warranty does not apply to (1)
damage to units caused by accident, dropping or abuse in handling, or any
negligent usage; (2) units that have been repaired, taken apart, or modified
by unauthorized personnel; (3) units not used in accordance with instruction;
(4) damages exceeding the cost of the product; (5) transit damage, initial
installation costs, removal cost, or reinstallation cost.
For information on additional devices, please visit us at www.visionsecurity.com.tw
Installation & Operation Manual
ZM 1602 IN-5
ZM 1602 MY-5
ZM 1602 EU-5
ZM 1602 RU-5
ZM 1602 US-5
ZM 1602 IL-5
ZM 1602 KR-5
ZM 1602 HK-5
ZM 1602 BR-5
ZM 1602 JP-5
DC/AC Power Siren
Introduction
Thanks for choosing the Vision’s wireless siren & strobe alarm of the home
security device. This sensor is a Z-WaveTM enabled device (interoperable, two-
way RF mesh networking technology) and is fully compatible with any Z-WaveTM
enabled network and its security framework. Every main powered Z-WaveTM
enabled device acts as a signal repeater and multiple devices result in more
possible transmission routes which helps eliminate “RF dead-spots”. Z-WaveTM
enabled devices displaying the Z-WaveTM logo can also be used with it
regardless of the manufacturer, and ours can also be used in other
manufacturer’s Z-WaveTM enabled networks. This product will sound a loud siren
and flash a strobe light when an alarm message or alert is received on any
Z-WaveTM enabled network. When ZM 1602 main power has dropped out, the backup
batteries will automatically install. When the device is securely included in
the Z-Wave network, the above communication will be encrypted.
Product Description and Specification
For indoor use only
Z-Wave Command Class: COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SWITCH_BINARY (Mapping COMMAND_CLASS_BASIC) COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_ZWAVEPLUS_INFO
Installation
Notice: If you are installing the entire Z-WaveTM system for the first time,
please refer to the installation guide of the Z-WaveTM Interface Controller
before installing ZM1602.
1. Remove the bracket from the siren by press the locking tab, and then
gently slide up the siren.
2. Remove two screws and pull out the plastic case as below. Pull out the
short head & put it back into the position where two pinheads are
covered.
3. Knock out the thin wall on the bracket. The power line goes through the
hole on the bracket and connects to the screw terminal on ZM1602.
4. Using the screws or adhesive tape to affix the bracket to the chosen
location.
5. LED Status for Z-Wave Network: After power on, the LED Setting Light will
flash if the siren has not been included yet. After power on, the LED Setting
Light will go off if the siren has been included.
6. Slide back the cover and screw fastening with the front cover.
7. For “ Inclusion ” in (adding to) a network: Put the Z-WaveTM Interface
Controller into “inclusion” mode, and following its instruction to add the ZM
1602 to your controller. To get in the “inclusion” mode, the distance between
siren and controller is suggested to be in one meter. Open the bracket and
press the program switch of ZM 1602 for 1 second at least & release to be
included. After setting, the LED Setting Lighting should go off, if not,
please try again. (After sending one time’s
Z-Wave NIF and not be included then it will send 4 times NWI in every 4 ~ 6
seconds for auto inclusion. The LED Setting Light will flash again if the
siren has not been included or the LED Setting Light will go off after
inclusion.)
For “ Exclusion ” from (removing from) a network: Set up the Z-WaveTM
Interface Controller into “exclusion” mode, and following its instruction to
delete the ZM 1602 from your controller. Press the Tamper Switch of ZM 1602
for 1 second at least &
release to be excluded.
Note :
a. LED setting light will flash continuously in Exclusion condition.
b. All user and network settings will be cleared and the device reset to
factory defaults when the device is excluded.
c. ZM 1602 can only connect to DC 9-24V, AC 9-18V Power adapter
d. ZM 1602 is extremely LOUD, please don’t near your ear when you test!
For “ Association “: removing the back cover of the ZM1602 to get into “Awake” mode, then put the Z-Wave Interface Controller into “association”, and following its instruction to the association the ZM1602 with another device. Close the back cover after “association” done, afterward, the ZM1602 will get into “Sleep” mode for power saving. Support one association group (5 nodes).
8. Configuration command class:
(Parameter 1) Siren/Strobe Mode: The user can change the value from 0 to
2 to turn either Siren sound, Strobe light, or both when triggered.
(Parameter 2) Alarm Auto Stop Time : The user can change the duration of
siren time when triggered.
9. Support OTA Firmware update from the controller. Please refer to your
controller manual. We recommend excluding the device & inclusive again before
using the device.
10. Repeater Function: This device acts as a repeater for the Z-Wave mesh
network functionality.
11. All the rest commands depend on the Z-Wave standard.
Operation
1. Normal operation, the LED light will not on.
2. Alarm Mode:
Active: It will active the Alarm Mode after receiving Basic Set (ON) or Binary
Switch (ON). The LED Strobe Light & SIREN will be active according to the
Configuration’s setting value.
Stop: It will stop the Alarm Mode after receiving Basic Set (OFF) or Binary
Switch (OFF) which depends on Configuration’s setting value.
Auto Stop: After stopping the alarm, it will send Binary Switch Report (0x00)
3. Self-Protection Mode: After put back the bracket over 5 seconds, ZM
1602 will enter the Self-Protection Mode which will active “LED Strobe Light &
SIREN at the same time. The Alarm Mode will be triggered If the back cover has
been opened during the Self-Protection Mode The Stop method is the same as the
Alarm Mode. It will send a notification when the bracket was put back after
the strobe and siren has stopped
4. This device can’t be reset manually. It is reset to factory defaults when
it is excluded.
5. Security Enabled: Z-Wave controller must be used to fully utilize the
product.
6. Lifeline group used command :
{COMMAND_CLASS_NOTIFICATION_V4,NOTIFICATION_REPORT_V4}
{COMMAND_CLASS_DEVICE_RESET_LOCALLY,DEVICE_RESET_LOCALLY_N OTIFICATION}
7. Support Explorer Frame Function.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>