POLAR GE769 Triple Door Upright Display Chiller Instruction Manual

June 3, 2024
Polar

POLAR GE769 Triple Door Upright Display Chiller

Safety Instructions

Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your POLAR product.

  • Position on a flat, stable surface.

  • A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components or service panels on this product.

  • Consult Local and National Standards to comply with the following:
    – Health and Safety at Work Legislation
    – BS EN Codes of Practice
    – Fire Precautions
    – IEE Wiring Regulations
    – Building Regulations

  • DO NOT immerse in water, or use steam/jet washers to clean the unit.

  • DO NOT cover the appliance when it is operating.

  • Always carry, store and handle the appliance in a vertical position.

  • Never tilt the appliance more than 45° from the vertical.

  • Not suitable for outdoor use.

  • Keep all packaging away from children. Dispose of the packaging in accordance with the regulations of local authorities.

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

  • Children should be supervised to ensure that they do not play with the appliance.

  • POLAR recommend that this product is connected to a circuit protected by an appropriate RCD (Residual Current Device).

  • POLAR recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing.

Warning: Risk of Fire

  • Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.

Warning: Keep all ventilation openings clear of obstruction. Unit should not be boxed in without adequate ventilation.

  • Warning: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • Warning: Do not damage the refrigerant circuit.
  • Warning: Do not use electrical appliances inside the food storage compartments of the appliance, unless they are the type recommended by the manufacturer.

Pack Contents

The following is included:

  • Display Chiller
  • Instruction manual

POLAR prides itself on quality and service, ensuring that at the time of packaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your POLAR dealer immediately.

Installation

| Note: If the unit has not been stored or moved in an upright position, let it stand upright for approximately 12 hours before operation. If in doubt allow to stand.
---|---

  1. Remove the appliance from the packaging and the protective film from all surfaces.
  2. Avoid positioning the cooler in direct sunlight or damp areas.
  3. To optimize performance and longevity, ensure a minimum clearance of 2.5cm is maintained between the unit and walls and other objects, with a minimum 5cm clearance on the top. NEVER LOCATE NEXT TO A HEAT SOURCE.
  4. Set the brakes on the castors to keep the appliance in position.

| Note: Before using the appliance for the first time, clean the shelves and interior with soapy water.
---|---

Operation

Turn On
  1. Close the doors of the appliance.
  2. Connect the appliance to a mains power supply.
  3. Turn the light switches On [I] or Off [O] as desired.
Control Panel

Set the Operating Temperature
  1. Hold the SET button for 3 seconds. The display will flash.
  2. Press the or buttons to display the required temperature.
  3. Press the SET button to store the temperature.
Manual Defrost
  • The appliance will automatically run a defrost cycle every 4 hours.
  • To manually defrost the appliance: Press and hold the defrost button “ ” for 2 seconds to begin a manual defrost. The defrost light illuminates.

Cleaning, Care & Maintenance

  • Switch off and disconnect from the power supply before cleaning.
  • Clean the interior of the appliance as often as possible.
  • Do not use abrasive cleaning agents. These can leave harmful residues.
  • Always wipe dry after cleaning.
  • If left unused for any length of time, store the appliance with the door ajar.

Condensation will form in refrigeration with frequent opening of the doors and on hot humid days, please ensure condensation is allowed to drain properly or is wiped dry.

Troubleshooting

A qualified technician must carry out repairs if required.

Fault Probable Cause Solution
The appliance is not working The unit is not switched on Check the unit is

plugged in correctly and switched on
Plug or lead is damaged| Replace plug or lead
Fuse in the plug has blown| Replace the fuse
Mains power supply fault| Check mains power supply
Appliance is noisy or works intermittently| Appliance is not level| Check installation position and change if necessary
The appliance is touching a neighboring object| Check installation position and change if necessary
Cooler cabinet is not cold enough| Temperature set incorrectly| Check temperature and reset if necessary
External environment may require colder temperature| Check temperature and reset if necessary
The door is opened too often| Only open when necessary
Door seal is worn| Call POLAR agent or qualified technician
Condensation| Condensation may occur when the humidity is high and water particles in the air contact with cold surfaces. This is normal, just wipe away with a dry cloth

Technical Specifications

Model| Voltage| Power| Current| Temperature Range| Refrigerant| Dimensions H x W x D mm| Weight (kg)| Shelf load (Max.)
---|---|---|---|---|---|---|---|---
GE769| 220-240V~

50Hz

| 750W| 4.1A| 2°C-10°C| R290, 95gx2| 2036 x 1560 x 730| 174| 20kg

Electrical Wiring

POLAR appliances are supplied with a 3 pin BS1363 plug and lead. The plug is to be connected to a suitable mains socket. POLAR appliances are wired as follows:

  • Live wire (coloured brown) to terminal marked L
  • Neutral wire (coloured blue) to terminal marked N
  • Earth wire (coloured green/yellow) to terminal marked E

This appliance must be earthed.

If in doubt consult a qualified electrician

Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.

Disposal

EU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses, metal and plastic components.
Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally.
Alternatively call the POLAR helpline for details of national disposal companies within the EU.

Compliance

| The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.
---|---

POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent,  and federal authorities.

POLAR products have been approved to carry the following symbol:

DECLARATION OF CONFORMITY

Equipment Type

|

Model

---|---

G-Series Upright Display Chiller – Triple Door

|

GE769 (-E & -A)

Application of Territory Legislation &
Council Directives(s)| Machinery Directive 2006/42/EC
Supply of Machinery (Safety) Regulations 2008
EN 60335-1:2012 +A11:2014 +A13:2017
EN 60335-2-89:2010 +A1:2016 +A2:2017
EN 62233:2008
Electro-Magnetic Compatibility (EMC) Directive 2014/30/EU – recast of 2004/108/EC
Electromagnetic Compatibility Regulations 2016
(S.I. 2016/1091)
EN 55014-1: 2017
EN 55014-2:2015
EN 61000-3-2: 2014
EN 61000-3-3:2013 +A1:2017
Regulation (EU) 2019/2024 – Ecodesign direct sales refrigerators
EN 16902:2016
Restriction of Hazardous Substances Directive (RoHS) 2015/863 amending Annex II to Directive 2011/65/EU
Restriction of the Use of Certain Hazardous
Substances in Electrical and Electronic
Equipment Regulations 2012 (S.I. 2012/3032)| Electrical Safety
EN 60335-1:2012 +A11:2014 +A13:2017
EN 60335-2-89:2010 +A1:2016 +A2:2017
EN 62233:2008
Electromagnetic Compatibility
EN 55014-1: 2017
EN 55014-2:2015
EN 61000-3-2: 2014
EN 61000-3-3: 2013 +A1:2017
Producer Name| Polar

I, the undersigned, hereby declare that the equipment specified above conforms to the above Territory Legislation, Directive(s) and Standard(s).

Date 3rd December 2021
Signature
Full Name Ashley Hooper
Position Technical & Quality Manager

Commercial Manager/ Responsible Supplier
Producer Address| Fourth Way,
Avonmouth, Bristol, BS11 8TB United Kingdom| 42 North Point Business Park New Mallow Road Cork Ireland| 15 Bagdally Road, Campbelltown NSW 2560

UK| ****


+44 (0)845 146 2887

---|---
Eire
NL| 040 – 2628080
FR| 01 60 34 28 80
BE-NL| 0800-29129
BE-FR| 0800-29229
DE| 0800 – 1860806
IT| N/A
ES| 901-100 133


 http://www.polar-refrigerator.com/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals