Getting Started
Turn off computer’s power before connecting the scanner, then power up the
computer once the scanner is fully connected. When the base is connected and
powered up, put the scanner in the base to establish a link. The green LED on
the base flashes to indicate the scanner’s battery or charge pack is charging.
**Power Supply Assembly (if included)
Note:** The power supply must be ordered separately, if needed.
Connecting the Base USB:
Note: If you are charging the scanner using the USB cable, the current
available for charging is reduced and charge times are increased. Charging via
the power supply is faster.
Keyboard Wedge:
RS232 Serial Port:
Reading Techniques
The view finder projects an aiming beam that should be centered over the barcode, but it can be positioned in any direction for a good read. Note: If the scanner beeps 3 times when scanning a barcode, the link has not been established. If the scanner beeps once, the link has been established.
SR Models:
**XR Models:
**
Standard Product Defaults
The following barcode resets all standard product default settings.
Standard Product Defaults
USB Serial
If you are using a Microsoft® Windows® PC, you must download a driver from the
Honeywell website. The driver will use the next available COM Port number.
Scan the following code to program the scanner to emulate a regular
RS232-based COM Port. Apple® Macintosh computers recognize the scanner as a
USB CDC class device and automatically use a class driver.
USB Serial
Note: No extra configuration (e.g., baud rate) is necessary.
USB PC Keyboard Scan the following code to program the scanner for a USB
PC Keyboard.
USB PC Keyboard
Keyboard Country
Scan the appropriate country code below to program the keyboard layout for
your country or language. By default, national replacements are used for the
following characters: #$@[\]^`{|}~. Refer to the ISO 646 Character
Replacements chart in your User Guide to view the character replacements for
each
country.
USA (Default)
**Denmark
France
Belgium
Finland
Germany/Austria
Great Britain
Italy
Norway
Spain
Switzerland
Note:** For a complete list of country codes, see the User Guide for your
product.
Locked Link
If you link a scanner to a base using the Locked Link Mode, other scanners are
blocked from being linked if they are inadvertently placed into the base. If
you do place a different scanner into the base, it will charge the scanner,
but the scanner will not be linked.
Locked Link Mode (Single Scanner) To use a different scanner, you need to
unlink the original scanner by scanning the Unlink Scanner barcode.
Override Locked Scanner
If you need to replace a broken or lost scanner that is linked to a base,
scan the Override Locked Scanner barcode with a new scanner, and place that
scanner in the base. The locked link will be overridden; the broken or lost
scanner’s link with the base will be removed, and the new scanner will be
linked.
Override Locked Scanner
Unlinking the Scanner If the base has a scanner linked to it, that scanner
must be unlinked before a new scanner can be linked. Once the previous scanner
is unlinked, it will no longer communicate with the base. Scan the Unlink
Scanner barcode to unlink a scanner.
Unlink Scanner
Trigger
The following barcodes will allow you to use the scanner in Manual Trigger –
Normal Mode (need to press the trigger to read) or Presentation mode (the
scanner is activated when it “sees” a barcode). Note: Presentation Mode
continuously draws power, so use of
the external power supply is recommended for this mode.
Manual Trigger – Normal (Default)
Presentation Mode
Streaming PresentationTM
When in Streaming Presentation mode, the scanner leaves the scan illumination on all the time and continuously searches for barcodes.
Streaming Presentation Mode
Suffix
If you want a carriage return after the barcode, scan the Add CR Suffix barcode. To add a tab after the barcode, scan the Add Tab Suffix barcode. Otherwise, scan the Remove Suffix barcode to remove the suffixes.
**Add CR Suffix
Add Tab Suffix
Remove Suffix
Add Code ID Prefix to all Symbologies Scan the following barcode if you
wish to add a Code ID prefix to all symbologies at once.
Add Code ID Prefix To All Symbologies (Temporary)
Note:** For a complete list of Code IDs, see the User Guide for your
product.
Function Code Transmit
When this selection is enabled and function codes are contained within the
scanned data, the scanner transmits the function code to the terminal. Charts
of these function codes are provided in your User Guide. When the scanner is
in keyboard wedge mode, the scan code is converted to a key code before it
is transmitted.
Enable (Default)
Disable
Support
To search our knowledge base for a solution or to log into the Technical Support portal and report a problem, go to www.hsmcontactsupport.com.
User Documentation
For the user guide and other documentation, go to www.honeywellaidc.com.
Limited Warranty
For warranty information, go to www.honeywellaidc.com and click Resources > Product Warranty
Patents
For patent information, see www.hsmpats.com.
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in
specifications and other information contained in this document without prior
notice, and the reader should in all cases consult HII to determine whether
any such changes have been made. The information in this publication does not
represent a commitment on the part of HII. HII shall not be liable for
technical or editorial errors or omissions contained herein; nor for
incidental or consequential damages resulting from the furnishing,
performance, or use of this material. HII disclaims all responsibility for the
selection and use of software and/or hardware to achieve intended results.
This document contains proprietary information that is protected by copyright.
All rights are reserved. No part of this document may be photocopied,
reproduced, or translated into another language without the prior written
consent of HII. Copyright 2020 Honeywell International Inc. All rights
reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>