PowerWalker User Manual

June 7, 2024
PowerWalker

PowerWalker VI 500/750 R1U User Manual

IMPORTANT SAFETY INSTRUCTIONS

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)

CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.

CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.

CAUTION! Do not plug the UPS input into its own output.

CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.

CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.

CAUTION! Do not attach a power strip or surge suppressor to the UPS.

CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.

INSTALLING YOUR UPS SYSTEM

UNPACKING

The box should contain the following:

  1. UPS Unit x 1;
  2. User Manual x 1;

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

  1. Ensure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit’s rated capacity (500VA/300W for VI500R1U, 750VA/450W for VI750R1U). If rated unit capacities are exceeded, an overload condition may occur and cause the UPS unit to shut down or the fuse blow.
  2. There are many factors that can affect the amount of power that your computer system will require. For optimal system performance keep the load below 80% of the unit’s rated capacity.

HARDWARE INSTALLATION GUIDE

  1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
  2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device.
  3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands.
  4. Depress the power switch to turn the unit on. The LCD indicator light will illuminate and the unit will “beep”.
  5. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  6. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three
    months to ensure battery life.

ROUTINE MAINTENANCE AND STORAGE

ROUTINE MAINTENANCE

  1. Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent that contains alcoholic ingredient.
  2. The expected lifetime of the battery is around 3 years. Improper operation and harsh environment will reduce the actual lifetime.
  3. Unplug the UPS from power inlet if the UPS will not operate for long period of time.

STORAGE

  1. First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables connected the UPS to avoid battery drain.
  2. The UPS should be stored in a cool dry location.
  3. Make sure the battery is fully charged before the UPS is stored.
  4. For extended storage in moderate climates, the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat it every 2 months in high temperature locations.

BASIC OPERATION

FRONT AND TOP PANEL DESCRIPTION

FRONT AND TOP PANEL DESCRIPTION

VI 500/750 R1U

  1. AC Inlet
    Connect to utility power through the input power cord.

  2. Input Circuit Fuse
    The fuse provides optimal overload protection.

  3. AC outlet
    The UPS provides outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes.

  4. SNMP/HTTP Network Port
    The SNMP/HTTP port provides remote monitoring and management of your UPS over a network.

  5. Serial Port
    This port allows connection and communication from the DB9 serial on the computer to the UPS unit. The UPS communicates its status to the software.

  6. EPO Port
    Enables an emergency UPS Power-Off from a remote location. EPO terminal open, the UPS will turn off and the output shutdown immediately.

  7. Setting Button
    The audible alarm can be turned off/on by pressing this button.

  8. Power On/Off Switch
    Press the power switch to turn the UPS ON or OFF.

  9. LCD Display
    The LCD will display the UPS status including input voltage, output voltage, runtime, percentage of load and battery, etc.

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

DEFINITIONS FOR ILLUMINATED LCD INDICATORS

LCD Indication

LCD Indication

Line mode & Batt. Mode

Line mode & Batt. Mode

TROUBLE SHOOTING

TROUBLE SHOOTING

All rights reserved. Reproduction without permission is prohibited.