simx ARIA Settable Passive Ventilation Kit Installation Guide

June 7, 2024
Simx

simx ARIA Settable Passive Ventilation Kit

Product Information

Specifications

  • Product Name: ARIA Settable Passive Ventilation Kit
  • Application: Supply air ventilator for bedrooms and living rooms
  • Features: Variable opening damper, insect filter, rigid wall-duct sections, weatherproof dome cowl
  • Dimensions: 48mm (Valve blade), 80-350mm (Pipe section), 50mm (Moisture control dam)

Specifications are subject to change without notice. Distributed by Simx Limited. For warranty details, refer to the warranty information provided.

FAQ

Q: Can the damper blade be completely removed for maximum airflow?

A: Yes, for highest effective aerodynamic opening areas, the damper blade can be easily removed completely.

Q: What should I do if there is a defect in the Goods during the Warranty Period?

A: To claim under the warranty, return the Goods to the Supplier with the original proof of purchase including specific details as mentioned in the warranty information.

Thank you for choosing the Manrose ARIA 90mm settable passive ventilation kit with knock-outs for minimum closure applications. Supply air ventilator for installation in bedrooms and living rooms etc. The recommended placement is high on the wall and preferably diagonally opposite the door opening that the air will be drawn through. The ventilator consists of an internal vent, fitted with a variable opening damper and insect filter, rigid wall-duct sections and outer weatherproof dome cowl. The valve is adjusted via a slide control unit located on the underside of the ventilator. The minimum open area is obtained by removing the centre knock-out rings of the valve blade. For highest effective aerodynamic opening areas, the damper blade can be easily removed completely.

Description

Description Product Code
ARIA Settable Passive Ventilation DCT0102
Replacement External Typhoon Dome Cowl DCT4572

simx-ARIA-Settable-Passive-Ventilation-Kit-fig-1

INSTALLATION

  1. Penetration
    The minimum distance to the ceiling is approx 10 cm.
    Cut a Ø105 mm hole through the wall with a slight outward angle, approx. 1 mm/90 mm. Use a holesaw or drill a ring of small holes.

  2. Installing the external Typhoon dome cowl.
    Press the outer sleeve onto the Typhoon dome cowl.
    Fit the required number of rigid duct sections to extend through the wall. Insert the Typhoon dome cowl, sleeve, and fitted rigid duct tube through the wall from the outside, and screw the Typhoon dome cowl into position. Seal the façade using silicone sealant.

  3. 3 & 4. Installing the inner section
    Fit the seal onto the ventilator’s pipe section. Remove the cover from the chassis. Apply sealant on the back of the inner section, see illustration 3. Push the ventilator into the pipe and screw the inner section into position. Refit the cover and then set
    the required flow using the control unit.

simx-ARIA-Settable-Passive-Ventilation-Kit-fig-2

DIMENSIONS (mm)

simx-ARIA-Settable-Passive-Ventilation-Kit-fig-3

Simx Warranty Information

In this warranty:

  • We means Simx;
  • You means the consumer of the Goods
  • Supplier means the authorised distributor or retailer that sold you the
  • Goods in New Zealand or Australia; and Goods means the Simx product accompanied by this warranty and purchased in New Zealand or Australia.

The benefits provided to you under the following warranty are in addition to any other rights and remedies available to you under the law:

  1. If, during the time from the date of purchase (Warranty Period), there is a defect in the Goods due to improper workmanship or material, we will replace or repair the Goods without charge. Any replacement product is warranted only for the time remaining on the original Warranty Period.

  2. We are not obliged to replace or repair the Goods under clause 1 if the Goods have been improperly stored, installed, connected, used, operated, repaired, damaged, abused, tampered with, altered (without our written approval), or not maintained in accordance with our recommended installation, connection and operating instructions.

  3. We exclude liability for:

    • a) consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever;
    • b) damage to consumable items such as lamps and starters; and
    • c) damage arising from normal wear and tear.
  4. In order to claim under this warranty you must, within the Warranty Period, return the Goods to the Supplier, together with the original proof of purchase including the details below:
    Supplier Name
    Date of Purchase

    Model Number
    Invoice/Receipt No.

  5. This warranty does not cover the cost of claiming under the warranty or transporting the Goods to and from the Supplier.
    Our Goods come with guarantees that cannot be excluded under the New Zealand and Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the Goods repaired or replaced if the Goods fail to be of acceptable quality and the failure does not amount to a major failure.
    To speak to someone about your Simx product or claiming under this warranty, please contact:

Simx Ltd New Zealand
p: +64 9 259 1660
www.simx.co.nz

Installation Instructions
sales@simx.co.nz | www.manrose.co.nz

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Simx User Manuals

Related Manuals