JOHN LEWIS Lucca 3lt Spotlight User Manual
- June 7, 2024
- John Lewis
Table of Contents
JOHN LEWIS Lucca 3lt Spotlight
Thank you for purchasing this Lucca 3lt spot light. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product.
Warnings!
This is a Class 1 product and must be earthed
Please read these instructions carefully before commencing any work. It is
recommended that this fitting is installed by a qualified electrician. Install
in accordance with the IEE Wiring regulations and the Building Regulations.
To prevent electric shock switch off at mains supply before installing or
maintaining this fitting.
Ensure other persons cannot restore the electrical supply without your
knowledge.
This light fitting should be connected to a 5 amp fused circuit.
If replacing an existing fitting, make a note of the connections.
This product is suitable for installation on surfaces with normal flammability
e.g. wood, masonry. It is not suitable for use on highly flammable surfaces
(e.g. polystyrene, textiles).
The light must not be positioned any closer than 0.3m (30cm) to the
illuminated surface.
For your safety, always switch off the supply before cleaning or adjusting.
If you are in any doubt, please consult a qualified electrician.
This product has special protection against the ingress of moisture and is IP44 rated. This product is suitable for use in Zone 1, Zone 2, and outside Zones of a bathroom. See diagram. If installing in a bathroom a 30mA RCD must be used in accordance with IEE Wiring Regulations and the Building Regulations.
The
glass shades must be replaced if they become cracked or damaged. Do not use
product without glass shades attached.
Parts List
Light Fitting
| |
1
|
Screws
| | 2
---|---|---|---|---|---
Wall Plugs
| |
2
Assembly
Refer to assembly drawing opposite. Carefully unpack the carton, making sure all the parts are present before assembly.
Step 1
Before removing the existing fitting, carefully note the position of each
set of wires. Where a ring/loop circuit exists there will be a fourth set of
wires (usually red) that are not connected to the L, N, or E. of the fitting.
This circuit must be kept together in the 4th terminal of the connection
block, and insulated from the fitting and the other wires. The ring/loop will
remain live unless isolated at the mains or circuit breaker regardless of
the position of the wall switch.
Step 2
Remove the fixing bracket (A) from the ceiling cover by removing the side
screws **(B). See Fig. 1.
**
Step 3
Attach to the ceiling using the screws provided. Refer to Fig. 2. Ensure
there is a joist at the point of fixing to support the weight of the product.
Take care to avoid damaging any concealed wiring and pipes.
Step 4
Having identified the household wiring from your existing light fitting,
connect to the connection block inside the product in the following way:
Check that…..
You have correctly identified the house wires.
The connections are tight.
No loose strands have been left out of the connection block.
The lid is fitted back onto the terminal block
Step 5
Referring back to Figure 1 , reattach the product to the fixing strap.
This product has “L” shaped fixing slots to allow easy fixing to the ceiling
strap. Locate the “L” slots (C) around the small screws (B) on the
ceiling strap (A). Rotate the ceiling cover to attach the product to the
strap. Tighten the screws to secure. Take care not to trap any wiring.
Step 6
See Fig. 3. Screw clear glass shade (B) on to the lamp holder (A).
Ensure the shade is fully tightened. Fit the bulb (C) as listed overleaf,
then place rubber washer (D) over bulb and screw on small shade (E).
Ensure both shades are properly seated to form a watertight seal. Do not
overtighten either of the shades.
The glass shades must be replaced if they become cracked or damaged. Do
not use product without the glass shades attached. This is the symbol that
denotes this requirement:
Step 7
Replace fuse or circuit breaker and switch on. Your light is now ready for
use.
Care Instructions
We recommend cleaning with a soft dry cloth. Do not use abrasive materials as these will damage the finish.
Recommended bulb
3 x 5-7W LED Energy efficient G9
When changing a bulb, always switch off at the mains and allow the bulb to cool before handling.
Dispose of used bulbs carefully. Do not exceed the wattage stated or use a different shape bulb from that indicated on the fitting. Use a cloth when handling bulbs as contact with bare hands will reduce the bulb life. Some energy saving bulbs are not suitable for use with a dimmer switch.
Specifications
Maximum Power: 3 x 4W
Voltage: 240V, 50Hz
IP Rating: IP44
Weight: 0.96kg
Please keep these instructions for future reference.
This symbol indicates that this product should not be treated as normal household waste and it should be recycled. John Lewis do not operate instore take back, but as members of the Distributor Trade Back scheme have funded the development and upgrade of recycling facilities across the UK. Please take it to your nearest collection facility or for further details contact your local council or visit www.recycle-more.co.uk.
We have taken great care to ensure that this product reaches you in perfect
condition.
However, should any parts be damaged or missing please contact our Product
Helpline on (01202) 690945.
John Lewis Partnership
171 Victoria Street
London SW1E 5NN
johnlewis.com
Documents / Resources
| JOHN
LEWIS Lucca 3lt
Spotlight
[pdf] User Manual
Lucca 3lt Spotlight
---|---
References
- John Lewis & Partners | Department Store | Home, Fashion, Tech & More
- Everything you need to know to Recycle More
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>