SLOAN Integral Spout Temperature Mixer Installation Guide
- June 7, 2024
- SLOAN
Table of Contents
- PRIOR TO INSTALLATION
- Tools Required for Installation
- FAUCET ROUGH-IN
- INSTALL FAUCET
- SLIDE GASKET OVER FLEX HOSE(S) AND SECURE
- REMOVE LABEL FROM SENSOR
- ACTIVATE FAUCET
- SET AND FIX TEMPERATURE
- BATTERY REPLACEMENT
- SETTINGS
- SENSOR RANGE ADJUSTMENT
- 12/24 LINE PURGE FEATURE
- HOT LIMIT STOP ADJUSTMENT
- OPERATION
- CARE AND CLEANING
- TROUBLESHOOTING GUIDE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC,
BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS
Faucet Variations
-ISM
Integral Spout Temperature Mixer
Limited Warranty
Unless otherwise noted, Sloan Valve Company warrants its products,
manufactured and sold for commercial or industrial uses, to be free from
defects of material and workmanship for a period of three (3) years (one (1)
year for SF faucets, special finish and PWT electronics and 30 days on PWT
software) from the date of first purchase. During this period, Sloan Valve
Company will, at its option, repair, replace, or refund the purchase price of
any product which fails to conform with this warranty under normal use and
service. This shall be the sole and exclusive remedy under this warranty.
Products must be returned to Sloan Valve Company, at the customer’s cost. No
claims will be allowed for labor, transportation or other costs. This warranty
extends only to persons or organizations that purchase
Sloan Valve Company’s products are directly from Sloan Valve Company for
purpose of resale. This warranty does not cover the life of batteries.
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL
DAMAGES OF ANY MEASURE WHATSOEVER.
PRIOR TO INSTALLATION
Prior to installing the Sloan OPTIMA Plus® EAF-350 Series faucets, install the items listed below. Also, refer to rough-in illustrations.
- Lavatory/sink
- Drain line
- Hot/Cold water supply lines or pre-tempered water supply line
IMPORTANT:
- ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
- FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
- KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON COMPRESSION FITTINGS.
Trim Plates
When the EAF faucet is installed on a sink that has three (3) hole punching, a
trim plate should be used. Trim plates must be specifi ed and ordered
separately.
ETF-312-A Trim Plate for 4” (102 mm) Centerset Sink
ETF-510-A Trim Plate for 8” (203 mm) Centerset Sink
Tools Required for Installation
- 13mm open wrench or nut driver for faucet retainer nut
- 3/4” open-end wrench for female end of flex hose
FAUCET ROUGH-IN
Side View
Front View
INSTALL FAUCET
A. Remove nut, faucet retainer, and gasket. DO NOT remove the o-ring
from the base of the faucet.
DO NOT remove sensor label until step.4
B. Install faucet with o-ring into the center hole in deck or lavatory –
1-5/16” (33 mm) minimum hole required.
NOTE: if installing the faucet on a three (3) hole sink, a trim plate
should be installed at this time.
SLIDE GASKET OVER FLEX HOSE(S) AND SECURE
INSTALL STRAINER AND FLEX HOSE ONTO SUPPLY STOP. OPEN SUPPLY STOPS.
IMPORTANT: Flush dirt, debris, and sediment from supply line(s) before connecting flex hose(s).
A. Install strainer and flex hose(s) onto supply stop.
B. Tighten the flex hose(s) (with strainer in place) securely to the
supply stop(s).
C. Open
supply stop(s).
Note:
If water flows immediately after turning water stop to open position, then
proceed to step 4 (leave the water running; there is a ‘water off’ signal when
the faucet is first activated).
REMOVE LABEL FROM SENSOR
A.Remove Label from Sensor Window.
ACTIVATE FAUCET
A. Activate Faucet by holding installation instructions approximately
1-1/2” (38 mm) in front of the sensor window until the red light appears, then
remove the instruction sheet. The faucet will run for four (4) seconds and the
range will automatically adjust to its environment. Wait ten (10) seconds
after water shuts off before using the faucet.
B. Activate Faucet and check for leaks. If the faucet does not function,
refer to the Troubleshooting section of this instruction manual.
SET AND FIX TEMPERATURE
A. Adjust lever to set temperature.
B. Optional
– To fi x temperature, set lever to the desired position, then remove lever
and plug hole with cap.
BATTERY REPLACEMENT
Note: Replace the battery when RED LED indicator flashes each time faucet
is in use or when the faucet stops functioning.
A. Close supply stop(s). ****
B. Loosen screws with hex wrench and remove the cap.
C. Move battery retainer tab away from
the battery. Remove the old battery. Dispose of properly Wait 15 seconds
before installing the new battery.
D. Insert a new 6V type CR-P2 lithium battery. The RED LED will flash for
one (1) minute. Reinstall the battery cover. If LED doesn’t flash or if it
just lights up, removes and then reinserts the battery. If water flows
continuously after inserting the new battery and opening the supply stops,
wait for 15 seconds, remove and then reinsert the battery.
E. Replace the cover and tighten the screw with a hex wrench.
F. Open supply stop(s).
G. Wait ten
(10) seconds before using the faucet.
SETTINGS
IR-Click Feature
The IR-Click is a detector located in the sensor window of the faucet spout
that allows the user to place the faucet into the following function modes:
continuous Run, Temporary Off, and Auto Set Range Adjustment. To use the IR-
Click, cover the bottom half of the sensor with a finger wait 2 seconds for
Green ight, then remove finger. When in programming mode, each touch of IR-
Click will produce a quick Green flash.
Function | Press Button | LED Signal |
---|
Temporary OFF
(2 min)| 1.1 time for 2 seconds
2. 2 times (double push)| 1.LED Green (1)
2.LED Red pulsating flashes
reset:| 1 time or will reset
automatically after 2 mins|
Continuous Run
2 min default setup
(adjustable from 1-20 min)| 1.1 time for 2 seconds
2. 1 time for 3-5 seconds| 1.LED Green (1)
2.Water flows after releasing
reset:| 1 time or will reset
automatically after 2 mins|
Auto Set Range
Adjustment
Details Shown in Next
Section| 1.1 time for 2 seconds
2.2 times (double touch)
3.1 time for 4 seconds then
hold till the requested range is reached
4.Release| 1.LED Green (1)
2.LED Red blinks
3.LED Red (1-8)
4.LED Green (1)
SENSOR RANGE ADJUSTMENT
FACTORY SETTING IS APPROPRIATE FOR THE MAJORITY OF APPLICATIONS AND SHOULD NOT REQUIRE RESETTING UNLESS UNDER EXTREME SITUATIONS.
A. IR activation (see page 5). To enter programming mode place finger on IR-Click (covering the bottom half of sensor) 1 time for 2 seconds and remove, REEN light will come on. Then, place finger 2 times then remove. The light on the sensor should blink RED to indicate programming mode.
B. Cover IR-Click (bottom half of the sensor) until LED flashes RED 4 times – hold IR- Click until LED flashes 1 to 8 times from minimum to maximum range. See diagram below. Release when the requested range is reached.
C.
D. Wait until LED flashes GREEN
SENSOR RANGE ADJUSTMENT DIAGRAM
.
12/24 LINE PURGE FEATURE
This feature will operate the faucet every 12 or 24 hours since last use, or
if not used, to prevent stagnant water conditions.
The default purge duration is two minutes.
Consult factory regarding other timing options.
Steps to activate purge line feature:
- Activate IR: cover the lower part of the sensor window with a white card/paper until LED flashes GREEN to confirm program mode is active.
- Cover the lower part of the sensor window once more with a white card/paper for approximately 24 seconds (ignore LED indications during this period). Release when the requested program is reached. (See LED indications to right.)
Deactivate
Activate 12HR
Activate 24HR
Activate 48HR
HOT LIMIT STOP ADJUSTMENT
Activate 48HR
OPERATION
As the user’s hands enter the beam’s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water 10 Sec. to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time-out setting.
CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with a clean cloth or towel. While cleaning the bathroom tile, protect the faucet from any splattering of cleaner. Acids and cleaning fl uids will discolor or remove chrome plating.
TROUBLESHOOTING GUIDE
- Problem: Faucet does not function.
Cause: Adhesive packaging label affixed over sensor eye.
Solution: Remove the adhesive label from the sensor eye.
Cause: Permanent Off Activated showed by RED flashing LED.
Solution: Touch button on sensor window for 2 seconds, RED flashing
LED will stop and confi rmed with GREEN LED.
2. Problem: Faucet delivers water in an uncontrolled manner.
Cause: The faucet is defective.
Solution Contact Sloan Technical Support (see below).
3. Problem: Faucet does not deliver any water with hands in sensor range.
Indicator: Solenoid valve produces an audible “click.”
Cause: Water supply stop(s) closed.
Solution: Open water supply stop(s).
Cause: Water supply stop strainer(s) clogged.
Solution: Turn off water at supply stop(s). Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s), if required.
Turn on the water at supply stop(s).
Indicator: Solenoid valve does not produce an audible “click.”
Cause: Battery low.
Solution: Replace the battery (refer to battery replacement).
Solution Contact Sloan Technical Support (see below)
4. Problem: After removing label water does not flow.
Use this installation guide as a target by placing it in front of the sensor (approx. 1-1/2” away) until water begins fl owing, then remove installation instruction from the sensor.
Water will stop fl owing, wait 10 seconds before using faucet.
5. Problem: Faucet delivers only a slow flow or dribble when the sensor is
activated.
Cause: Water supply stop(s) are partially closed.
Solution: Completely open water supply stop(s).
Cause: Water supply stop strainer(s) clogged.
Solution: Turn off water at supply stop(s). Remove, clean, and reinstall
water supply stop strainer(s). Replace strainer(s), if required.
Turn on the water at supply stop(s).
Cause: Spray head is clogged.
Solution Remove, clean, and reinstall spray head. Replace spray head, if
required.
Cause: Faucet is defective.
Solution Contact Sloan Technical Support (see below).
6. Problem: Faucet does not stop delivering water or continues to drip
after the user is no longer detected.
Cause: Faucet is defective.
Solution Contact Sloan Technical Support (see below).
7. Problem LED indicator blinks RED when the faucet is in use.
Cause: Battery low.
Solution: Replace battery (refer to battery replacement)
8. Problem: The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines.
Cause: Supply stops are not adjusted properly.
Solution: Adjust supply stops.
Cause: For models with an integral mixing valve – The mixing valve is set
improperly for the water temperature desired.
Solution: Rotate the mixing valve handle clockwise to decrease water
temperature or counterclockwise to increase the water temperature.
When assistance is required, please contact Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614)
REPAIR PARTS LIST
Item Part No. No. | Description |
---|---|
1 | EAF-60 |
2 | EAF-61 |
3 | EFX-1015-A |
4A | EAF-22 |
4B | EAF-63 |
5A | EAF-1021-A |
(0.5 gpm only)
5B| EAF-1018-A| Electronic Sensor (7 Second Shut-off) with Fixing Clip Kit
(1.5 gpm only)
6| EAF-1019-A| Mixer Handle Assembly and Cartridge Kit
7| EAF-2| Solenoid Valve Cartridge (10 Faucet)
8| EAF-1020-A| Integral Side Mixer Handle Kit
9| EAF-8| Back Check (2 required for ISM models)
10| EAF-1| Faucet Mounting Kit
11| EAF-1008| 13″ (330 mm) Flexible Supply Hose (2 required for ISM models)
12| EAF-9| Filter (2 required for ISM models)
When assistance is required, please contact Sloan Technical Support at:
1-888-SLOAN-14 (1-888-756-2614)
Sloan
10500 Seymour Avenue
Franklin Park, IL 60131
P: 847-671-4300 / 800-9-VALVE-9
F: 847-671-4380 /
800-447-8329
customer.service@sloanvalve.com
www.sloanvalve.com
© 2015 SLOAN VALVE COMPANY
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>