The ENFORCER Wave-To-Open Sensors use IR technology to request egress from a protected area or activate a device with the simple wave of a hand. Since no touch is required, this sensor is ideal for use in hospitals, clinics, labs, cleanrooms (to reduce the risk of contamination), schools, factories, or offices. The SD-927PKC-NEVQ adds a manual override button.
Also available with Spanish (SD-927PKC-NSQ, SD-927PKC-NSVQ) or French (SD- 927PKC-NFQ, SD-927PKC-NFVQ) faceplates.
Features:
- Dual voltage, 12~24 VAC/VDC
- Range adjustable from 2 3/8-8″ (6~20 cm)
- Stainless-steel single-gang plate
- 3A relay, adjustable from 0.5~30 sec, toggle as long as the hand is near the sensor
- LED-illuminated sensor area for easy identification
- Quick connect screw-less terminal block
- Selectable LED colors (turns from red to green or green to red) when activated
SD-927PKC-NEVQ
- Adds manual override button as a backup to the sensor
Parts List:
1x Wave-To-Open Sensor
2x Mounting screws
3x 6″ (15cm) wire connectors*
1x Manual
*For override button, SD-927PKC-NEVQ only
Specifications:
Model | SD-927PKC-NEQ | SD-927PKC-NEVQ |
---|---|---|
Operating voltage | 12-24 VAC/VDC | |
Current draw (max.) | 120mA@12VDC | |
Relay type | Form C dry contact, 3A@24VDC | |
Override button | Switching capacity | N/A |
Mechanical life | N/A | 500,000 cycles |
Response time | 10ms | |
LEDS | Standby | Red* |
Triggered | Green* | |
Output time | Adjustable, 0.5-30 sec.. toggle, or as long as sensor is |
triggered
Sensing range| Adjustable, 2318″-8″ (6-20 cm)
Operating temperature| -4°-131° F (-20°-55° C)
Weight| 3-oz (85g)| 1 3.9-oz (110g)
*Default, reversible by jumper
Installation:
- Run four wires through the wall to a single-gang back-box.
- Connect the four wires from the back-box to the quick connect screw-less terminal according to Fig. 1.
- Screw the plate into the back-box, taking care not to crimp the wires.
- Remove clear protective film from the sensor before use.
Fig. 1 Connections (under the back cover)
Adjusting the LED Color:
- The LED color factory default setting is red (standby) and green (triggered).
- To reverse the LED color visual indicator to green (standby) and red triggered), remove the jumper located at the right side of the terminal block as shown in Fig. 2.
Adjusting the Sensor Range and Output Timer
- To adjust the sensor’s range, turn the trim pot counterclockwise (decrease) or clockwise (increase).
- To adjust the output time, turn the trim pot counterclockwise (decrease) r clockwise (increase). To set to toggle, turn the trim pot all the way counterclockwise.
Sample Installations:
-
Installation with Electric Lock
-
Installation with Electromagnetic Lock and Keypad
-
Override Button Wiring (SD-927PKC-NEVQ only)
The manual override button serves as a backup to the sensor
Care and Cleaning for the SD-927PKC Series Wave-To-Open Sensor:
The SD-927PKC Series is designed for indoor use to match most interiors. The sensor requires special care to ensure reliability and long operating life.
- Use a soft, clean cloth for cleaning.
- Be careful not to spray liquids directly on the unit.
- When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit.
- Be sure to wipe off any excess liquid from the sensor. Wet spots or areas may affect the sensor’s performance.
Overview:
IMPORTANT: Users and installers of this product are responsible for
ensuring that the installation and configuration of this product comply with
all national, state, and local laws and codes related to locking and egress
devices. SECO-LARM will not be held responsible for the use of this product in
violation of any current laws or codes.
IMPORTANT WARNING: Incorrect mounting which leads to exposure to rain or
moisture inside the enclosure could cause a dangerous electric shock, damage
the device, and void the warranty.
WARRANTY: This SECO-LARM product is warranted against defects in material
and workmanship while used in normal service for one (1) year from the date of
sale to the original customer. SECO-LARM’s obligation is limited to the repair
or replacement of any defective part if the unit is returned, transportation
prepaid, to SECO-LARM. This Warranty is void if the damage is caused by or
attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair or alteration, improper or abnormal usage, or faulty installation, or
if for any other reason SECO-LARM determines that such equipment is not
operating properly as a result of causes other than defects in material and
workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive
remedy shall be limited to the replacement or repair only, at SECO-LARM’s
option. In no event shall SECO-LARM be liable for any special, collateral,
incidental, or consequential personal or property damage of any kind to the
purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and
improvement. For that reason, SECO-LARM reserves the right to change
specifications without notice. SECO-LARM is also not responsible for
misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their
respective owners. Copyright © 2020 SECO- LARM U.S.A., Inc. All rights
reserved.
SECO-LARM®U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Phone:
949-261-2999 |
800-662-0800
Website: www.seco-larm.com
Email: sales@seco-larm.com
MI_SD-927PKC-NExQ_200805.docx
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>