ENFORCER SECO-LARM SLI Wave-To-Open Sensors User Manual

June 7, 2024
ENFORCER

ENFORCER logo SECO-LARM SLI logo

Wave-To-Open Sensors

Manual

ENFORCER SECO-LARM SLI Wave-To-Open Sensors

The ENFORCER Wave-To-Open Sensors use IR technology to request egress from a protected area or activate a device with the simple wave of a hand. Since no touch is required, this sensor is ideal for use in hospitals, clinics, labs, cleanrooms (to reduce the risk of contamination), schools, factories, or offices. The SD-927PKC-NEVQ adds a  manual override button.

Also available with Spanish (SD-927PKC-NSQ, SD-927PKC-NSVQ) or French (SD- 927PKC-NFQ, SD-927PKC-NFVQ) faceplates.

Features:

  • Dual voltage, 12~24 VAC/VDC
  • Range adjustable from 2 3/8-8″ (6~20 cm)
  • Stainless-steel single-gang plate
  •  3A relay, adjustable from 0.5~30 sec, toggle as long as the hand is near the sensor
  • LED-illuminated sensor area for easy identification
  •  Quick connect screw-less terminal block
  •  Selectable LED colors (turns from red to green or green to red) when activated

SD-927PKC-NEVQ

  • Adds manual override button as a backup to the sensor

Parts List:

1x Wave-To-Open Sensor
2x Mounting screws
3x 6″ (15cm) wire connectors*
1x Manual

*For override button, SD-927PKC-NEVQ only

Specifications:

Model SD-927PKC-NEQ SD-927PKC-NEVQ
Operating voltage 12-24 VAC/VDC
Current draw (max.) 120mA@12VDC
Relay type Form C dry contact, 3A@24VDC
Override button Switching capacity N/A
Mechanical life N/A 500,000 cycles
Response time 10ms
LEDS Standby Red*
Triggered Green*
Output time Adjustable, 0.5-30 sec.. toggle, or as long as sensor is

triggered
Sensing range| Adjustable, 2318″-8″ (6-20 cm)
Operating temperature| -4°-131° F (-20°-55° C)
Weight| 3-oz (85g)| 1       3.9-oz (110g)

*Default, reversible by jumper

Installation:

  1. Run four wires through the wall to a single-gang back-box.
  2. Connect the four wires from the back-box to the quick connect screw-less terminal according to Fig. 1.
  3.  Screw the plate into the back-box, taking care not to crimp the wires.
  4. Remove clear protective film from the sensor before use.

Fig. 1 Connections (under the back cover)ENFORCER SECO-LARM SLI Wave-
To-Open Sensors - Fig. 1

Adjusting the LED Color:

  1. The LED color factory default setting is red (standby) and green (triggered).
  2. To reverse the LED color visual indicator to green (standby) and red triggered), remove the jumper located at the right side of the terminal block as shown in Fig. 2.

ENFORCER SECO-LARM SLI Wave-To-Open Sensors - Fig. 2 Adjusting the Sensor Range and Output Timer

  1. To adjust the sensor’s range, turn the trim pot counterclockwise (decrease) or clockwise (increase).
  2.  To adjust the output time, turn the trim pot counterclockwise (decrease)  r clockwise (increase). To set to toggle, turn the trim pot all the way counterclockwise.

Sample Installations:

  1. Installation with Electric Lock

  2. ENFORCER SECO-LARM SLI Wave-To-Open Sensors - Electric LockInstallation with Electromagnetic Lock and KeypadENFORCER SECO-LARM SLI Wave-To-Open Sensors - Lock and Keypad

  3. Override Button Wiring (SD-927PKC-NEVQ only)
    The manual override button serves as a backup to the sensorENFORCER SECO-
LARM SLI Wave-To- backup to the sensor

Care and Cleaning for the SD-927PKC Series Wave-To-Open Sensor:

The SD-927PKC Series is designed for indoor use to match most interiors. The sensor requires special care to ensure reliability and long operating life.

  1. Use a soft, clean cloth for cleaning.
  2.  Be careful not to spray liquids directly on the unit.
  3.  When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit.
  4.  Be sure to wipe off any excess liquid from the sensor. Wet spots or areas may affect the sensor’s performance.

Overview:

ENFORCER SECO-LARM SLI Wave-To-Open Sensors -Overview

IMPORTANT: Users and installers of this product are responsible for ensuring that the installation and configuration of this product comply with all national, state, and local laws and codes related to locking and egress devices. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or codes.
IMPORTANT WARNING: Incorrect mounting which leads to exposure to rain or moisture inside the enclosure could cause a dangerous electric shock, damage the device,  and void the warranty.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This  Warranty is void if the damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and the purchaser’s exclusive remedy shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
NOTICE: The SECO-LARM policy is one of continual development and improvement. For that reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners. Copyright © 2020 SECO- LARM U.S.A., Inc. All rights reserved.

SECO-LARM®U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Phone: 949-261-2999 | 800-662-0800
Website: www.seco-larm.com
Email: sales@seco-larm.com
PICPN3
MI_SD-927PKC-NExQ_200805.docx

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ENFORCER User Manuals

Related Manuals