Lenovo Converged HX Series Nutanix Appliances User Guide
- June 3, 2024
- Lenovo
Table of Contents
Converged HX Series Nutanix Appliances
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances
Product Guide (withdrawn product)
Lenovo Converged HX Series Nutanix Appliances are designed to help you
simplify IT infrastructure, reduce costs, and accelerate time to value. These
hyperconverged appliances from Lenovo combine industryleading hyperconvergence
software from Nutanix with Lenovo enterprise platforms that feature Intel Xeon
processor E5-2600 v4 product family.
Several common uses for the Lenovo Converged HX3000 Series appliances for
compute-heavy workloads include virtual desktop infrastructure (VDI), server
virtualization, private/hybrid clouds, enterprise applications, light
databases, and remote office and branch office workloads. Starting with as few
as three nodes to keep your acquisition costs down, the HX Series is capable
of immense scalability as your needs grow.
The Lenovo Converged HX3000 Series include Lenovo Converged HX3310 and
HX3310-F (1U rackmount), HX3510-G (2U rack mount), and HX3710 and HX3710-F (2U
4-node [2U4N] rack-mount) appliances that are shown in the following figure.
Figure 1. Lenovo Converged HX3310/HX3310-F (top), HX3510-G (middle), and
HX3710/HX3710-F (bottom)
Did you know?
The Lenovo Converged HX Series appliances are built on industry-leading Lenovo
servers that feature enterprise-class reliability, management, and security.
The Lenovo Converged HX Series appliances deliver the industry’s most feature-
rich hyperconverged infrastructure to enterprise datacenters, bringing the
benefits of web-scale technologies to enterprise applications through
enterprise storage, data protection, infrastructure resilience, management and
analytics, and security.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
1
Key features
The Lenovo Converged HX Series Nutanix Appliances deliver the industry’s most
feature-rich hyperconverged infrastructure to enterprise datacenters (shown in
the following figure). Nutanix brings the benefits of web-scale technologies
to enterprise applications through enterprise storage, data protection,
infrastructure resilience, management and analytics, and security.
Figure 2. HX Series hyperconverged infrastructure
The Lenovo Converged HX Series appliances offer the following key features:
Enterprise storage
The Lenovo Converged HX Series Nutanix Appliances deliver enterprise data
storage as an ondemand service by employing highly distributed software
architecture. The Nutanix Software eliminates the need for traditional SAN and
NAS solutions, and delivers a rich set of software-defined services that are
entirely VM-centric, including snapshots, high availability, disaster
recovery, deduplication and more.
Inline and post-process compression at the sub-block level increase effective
storage capacity by up to four times.
Redirect-on-write snapshots and writeable clones at the granularity of a
single VM increase efficiency.
Distributed caching of VM data improves performance in multi-reader scenarios,
such as VDI with linked clones.
Inline deduplication in the read cache and post-process deduplication in the
capacity tier improve performance and effective capacity.
Powerful acceleration capabilities such as caching, automatic data tiering and
data locality speed storage performance.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
2
Data protection
The Nutanix Software offers a natively integrated solution for data protection
and continuous availability at VM granularity. It gives administrators an
affordable range of options to meet the recovery point objectives (RPO) and
recovery time objectives (RTO) for different applications.
Unlimited local backups using VM-centric snapshots and integrated workflows
delivering RPO in minutes.
Natively integrated solution for disaster recovery enables simple VM-centric
backup, recovery and replication with application-level consistency.
Built-in Cloud Connect hybrid cloud technology enables seamless backup of data
to public cloud services.
Metro availability feature provides continuous availability of data across
different sites during planned maintenance or disasters through synchronous
replication.
Support for Microsoft Volume Shadow Services (VSS), VMware vStorage API for
Data Protection (VADP), and seamless integration with third-party backup
providers.
Infrastructure resilience
The platform for the Lenovo Converged HX Series Nutanix Appliances is fault
resistant, with no single point of failure and no bottlenecks. The system uses
a shared-nothing architecture, where all data, metadata and services are
distributed to all nodes within the cluster, and is built to detect, isolate
and recover from failures anywhere in the system. Lenovo hyperconverged
appliances deliver always-on operation, and can survive system hardware,
software and hypervisor issues and maintain 100% availability to applications
and data.
Intelligent data placement in different physical failure domains, or
availability domains, (for example, separate racks or power sources) delivers
greater fault tolerance.
Data and metadata replicated across multiple nodes provide user-defined
resilience against hardware failures.
Multiple copies of data ensure 100% data availability in the event that a
Nutanix controller VM is unavailable due to failure or maintenance.
Automatic integrity checks during reads and silent at-rest error detection for
data consistency.
Management and analytics
The platform for the Lenovo Converged HX Series Nutanix Appliances marries
web-scale capabilities with an intuitive user-centric management experience to
simplify every aspect of the IT infrastructure lifecycle. Nutanix Prism
provides a single pane of glass to monitor and control one or more Nutanix
clusters, with simplified workflows and rich automation for common
administrative tasks.
Elegantly simple management framework with intuitive workflows delivers
radical simplicity and powerful control to IT management.
Single pane of glass delivers centralized visibility and management of
multiple Nutanix clusters across the world.
Rich automation and intuitive workflows simplify deployment, provisioning,
orchestration and maintenance of Nutanix clusters.
End-to-end visibility of VMs, nodes and disks and the ability to visually
diagnose potential issues gives administrators total infrastructure control.
Programmatic control of every aspect of cluster management, including
deployment, upgrades, data protection, and performance management enables
powerful automation.
Streamlined management for hypervisor and virtual machines on Nutanix.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
3
Security Nutanix software combines powerful features, such as two-factor
authentication and data-at-rest encryption, with a security development
lifecycle that is integrated into product development to help customers meet
the most stringent security requirements.
Security incorporated into every step of the software development process
enables verifiably secure software releases. Encryption of sensitive data with
self-encrypting drives (SEDs) that are FIPS 140-2 Level 2 conformant supports
stringent encryption requirements. Two-step authentication using a client
certificate and username/password, along with cluster lockdown, provides
protection against unauthorized access.
Components and connectors
The following figure shows the front view of the HX3310 or HX3310-F appliance.
Figure 3. HX3310 or HX3310-F front view The following figure shows the front
view of the HX3510-G appliance.
Figure 4. HX3510-G front view
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
4
The following figure shows the front view of the HX Series Enclosure with up
to four HX3710 or HX3710-F appliance nodes.
Figure 5. HX Series Enclosure with up to four HX3710 or HX3710-F appliances
front view The following figure shows the rear view of the HX3310 or HX3310-F
appliance.
Figure 6. HX3310 or HX3310-F rear view
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
5
The following figure shows the rear view of the HX3510-G appliance.
Figure 7. HX3510-G rear view The following figure shows the rear view of the
HX Series Enclosure with up to four HX3710 or HX3710-F appliance nodes.
Figure 8. HX Series Enclosure with up to four HX3710 or HX3710-F appliances rear view
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
6
System specifications
The following table lists the system specifications of the Converged HX3310
and HX3310-F appliances.
Table 1. HX3310 and HX3310-F appliance specifications
Attribute Form factor Processor
Chipset Memory
Memory capacity Memory protection Drive bays Storage capacity
Specification 1U Rack-mount (Machine Type 8693). Two processors of the Intel
Xeon processor E5-2600 v4 product family:
Up to 22 cores per processor (2.2 GHz core speeds) Up to 2.4 GHz core speeds
(14 cores per processor) Two QPI links up to 9.6 GT/s each per processor Up to
55 MB cache per processor Up to 2400 MHz memory speed Intel C612. 24 DIMM
sockets. Support for 16 GB and 32 GB RDIMMs or 64 GB LRDIMMs. Memory speed up
to 2400 MHz. Up to 1536 GB with 24x 64 GB LRDIMMs.
ECC and Chipkill.
8x 2.5-inch SAS/SATA hot-swap HX3310: Up to 12 TB (HDD) + 3.2 TB (SSD)
HX3310-F: Up to 30.72 TB (SSDs)
Storage controller Network interfaces
Boot drive I/O expansion slots
Ports
Cooling
Power supply Video
Hot-swap parts Systems management Security features Software
1x N2215 (12 Gbps SAS/6 Gbps SATA)
One or two dual-port 10 GbE SFP+ (Intel X520) or 10GBASE-T (Intel X550-T2)
adapters. 4x integrated RJ-45 Gigabit Ethernet 1000BASE-T ports (BCM5719). 1x
Ethernet (RJ-45) for systems management. 1x Embedded 64 GB SSD (6 Gbps SATA
DOM) connected to the onboard PCH SATA controller. Four slots. The slots are
as follows: Slot 1: PCIe 3.0 x16; low profile, half-length (for the first 10
GbE network adapter) Slot 2: PCIe 3.0 x16; low profile, half-length (for the
second 10 GbE network adapter) Slot 3: PCIe 3.0 x16; low profile, half-length
(not used) Slot 4: PCIe 3.0 x8 (dedicated for an internal storage controller)
Front: 2x USB 2.0 and 1x DB-15 VGA. Rear: 2x USB 3.0 and 1x DB-15 VGA.
Calibrated Vectored Cooling with seven redundant hot-swap system fans; two fan
zones with N+1 fan redundancy. Two redundant hot-swap 900 W (100 – 240 V) High
Efficiency Platinum AC power supplies. Matrox G200eR2 with 16 MB memory
integrated into the IMM2.1. Maximum resolution is 1600×1200 at 75 Hz with 16 M
colors. SSDs, HDDs, power supplies, and fans. UEFI, Integrated Management
Module II (IMM2.1) (based on Renesas SH7758) with Advanced Upgrade, Predictive
Failure Analysis, light path diagnostics, Lenovo XClarity, and Nutanix Prism.
Power-on password, administrator’s password, Trusted Platform Module (TPM)
2.0-ready.
Nutanix Acropolis: Starter, Pro, and Ultimate editions.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
7
Attribute Hypervisors
Hardware warranty Software maintenance Dimensions Weight
Specification
Nutanix Acropolis Hypervisor (default factory preload).
VMware ESXi 5.5 Update 3, 6.0 Update 1, and 6.0 Update 2 (optional factory
preload).
Optional support for Microsoft Windows Server 2012 R2 Datacenter Edition
(Hyper-V) (field-installable option only). Three-year or five-year customer-
replaceable unit and onsite limited warranty with selectable service levels:
9×5 next business day (NBD), 24x7x4, and 24x7x2. Three-year or five-year
software support and subscription (matches the duration of the selected
warranty period). Height: 43 mm (1.7 in), width: 434 mm (17.1 in), depth: 734
mm (28.9 in) Maximum configuration: 19.3 kg (42.5 lb)
The following table lists the system specifications of the Converged HX3510-G Series appliances.
Table 2. HX3510-G system specifications
Attribute Form factor Processor
Chipset Memory
Memory capacity Memory protection Drive bays Storage capacity Storage
controller Network interfaces
Boot drive I/O expansion slots
Specification
2U Rack-mount (Machine Type 8695). Two processors of the Intel Xeon processor
E5-2600 v4 product family:
Up to 18 cores (2.3 GHz core speeds) Up to 2.4 GHz core speeds (14 cores) Two
QPI links up to 9.6 GT/s each Up to 45 MB cache Up to 2400 MHz memory speed
Intel C612. 24 DIMM sockets. Support for 16 GB and 32 GB RDIMMs or 64 GB
LRDIMMs. Memory speed up to 2400 MHz. Up to 1536 GB with 24x 64 GB RDIMMs.
ECC and Chipkill.
8x 2.5-inch SAS/SATA hot-swap Up to 12 TB (HDD) + up to 3.2 TB (SSD); or Up to
30.72 TB (SSD)
1x N2215 (12 Gbps SAS/6 Gbps SATA)
One or two dual-port 10 GbE SFP+ (Intel X520) or 10GBASE-T (Intel X550-T2)
adapters. Four integrated RJ-45 Gigabit Ethernet 1000BASE-T ports (BCM5719).
One RJ-45 GbE systems management port. 1x Embedded 64 GB SSD (6 Gbps SATA DOM)
connected to the onboard PCH SATA controller. Seven slots. The slots are as
follows: Slot 1: PCIe 3.0 x16; full-height, full-length (for the first GPU
adapter) Slot 3: PCIe 3.0 x8; full-height, half-length (not used) Slot 4: PCIe
3.0 x8; low profile (for the first 10 GbE network adapter) Slot 5: PCIe 3.0
x8; low profile (for the second 10 GbE network adapter) Slot 6: PCIe 3.0 x16;
full-height, full-length (for the second GPU adapter) Slot 8: PCIe 3.0 x8;
full-height, half-length (not used) Slot 9: PCIe 3.0 x8 (for the N2215 storage
controller)
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
8
Attribute Ports
Cooling
Power supply Video
Hot-swap parts Systems management Security features Software Hypervisors
Hardware warranty Software maintenance Dimensions Weight
Specification Front: 3x USB 2.0. Rear: 2x USB 3.0, 1x DB-15 VGA.
Calibrated Vectored Cooling with six redundant hot-swap system fans; two fan
zones with N+1 fan redundancy. Two redundant hot-swap 1300 W (200 – 240 V)
High Efficiency Titanium AC power supplies. Matrox G200eR2 with 16 MB memory
integrated into the IMM2.1. Maximum resolution is 1600×1200 at 75 Hz with 16 M
colors. SSDs and HDDs, power supplies, and fans. UEFI, Integrated Management
Module II (IMM2.1) (based on Renesas SH7758) with Advanced Upgrade, Predictive
Failure Analysis, light path diagnostics, Lenovo XClarity, Nutanix Prism.
Power-on password, administrator’s password, Trusted Platform Module (TPM)
2.0-ready.
Nutanix Acropolis: Starter, Pro, and Ultimate editions. Nutanix Acropolis
Hypervisor (default factory preload). VMware ESXi 5.5 Update 3, 6.0 Update 1,
and 6.0 Update 2 (optional factory preload). Optional support for Microsoft
Windows Server 2012 R2 Datacenter Edition (Hyper-V) (field-installable option
only).
Three-year or five-year customer-replaceable unit and onsite limited warranty
with selectable service levels: 9×5 next business day (NBD), 24x7x4, and
24x7x2. Three-year or five-year software support and subscription (matches the
duration of the selected warranty period). Height: 87 mm (3.4 in), width: 446
mm (17.5 in), depth: 800 mm (31.5 in) Maximum configuration: 34 kg (75 lb)
The following table lists the system specifications of the Converged HX3710 and HX3710-F appliances.
Table 3. HX3710 and HX3710-F appliance specifications
Attribute Form factor
Processor
Chipset Memory Memory capacity Memory protection Drive bays Storage capacity
Specification HX Series enclosure: 2U Four-node (2U4N) rack-mount.
HX3710/HX3710-F: Half-wide, 1U node (Machine Type 8689); up to four nodes per
enclosure. Two processors of the Intel Xeon processor E5-2600 v4 product
family:
Up to 20 cores per processor (2.2 GHz core speeds) Up to 2.4 GHz core speeds
(14 cores per processor) Two QPI links up to 9.6 GT/s each per processor Up to
50 MB cache per processor Up to 2400 MHz memory speed Intel C612. 16 DIMM
sockets. Support for 16 GB and 32 GB RDIMMs. Memory speed up to 2400 MHz. Up
to 512 GB with 16x 32 GB RDIMMs.
ECC and Chipkill.
6x 2.5-inch SAS/SATA hot-swap drive bays per node in the enclosure (24 drives
per enclosure). HX3710: Up to 8 TB (HDD) + 3.2 TB (SSD). HX3710-F: Up to 9.6
TB (SSD).
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
9
Attribute Storage controller Network interfaces
Boot drive I/O expansion slots
Ports Cooling Power supply
Video
Hot-swap parts Systems management Security features Software Hypervisors
Hardware warranty Software maintenance Dimensions
Weight
Specification 1x H701-L (6 Gbps SAS/SATA)
2x 10 GbE SFP+ ports (Intel X520 mezz card) or 2x 10 GbE RJ-45 ports (Intel
X550-T2 PCIe adapter). 1x Ethernet RJ-45 port for systems management. 1x
Embedded 64 GB SSD (6 Gbps SATA DOM) connected to the onboard PCH SATA
controller. Three PCIe slots. The slots are as follows: Slot 1: PCIe 3.0 x16;
low profile (not used) Slot 2: PCIe 3.0 x8; OCP form factor (for the 10 GbE
mezzanine card) Slot 3: PCIe 3.0 x8; mezzanine slot (dedicated for an internal
storage controller) Rear: 2x USB 3.0 and 1x DB-15 VGA. Five simple-swap speed-
controlled system fans in the enclosure Two redundant hot-swap 1600 W AC (200
– 240 V) 80 PLUS Platinum-certified power supplies in the enclosure. Onboard
VGA controller with 16 MB memory integrated into the service processor (ASPEED
AST2400). Maximum resolution is 1920×1200 at 60 Hz with 32 bits per pixel.
SSDs, HDDs, and power supplies. UEFI, system LEDs, ThinkServer Management
Module (TMM) (ASPEED AST2400) with remote presence (keyboard, video, mouse,
and remote drive), Lenovo XClarity, and Nutanix Prism. Power-on password,
administrator’s password.
Nutanix Acropolis: Starter, Pro, and Ultimate editions. Nutanix Acropolis
Hypervisor (default factory preload). VMware ESXi 5.5 Update 3, 6.0 Update 1,
and 6.0 Update 2 (optional factory preload). Optional support for Microsoft
Windows Server 2012 R2 Datacenter Edition (Hyper-V) (field-installable option
only).
Three-year or five-year customer-replaceable unit and onsite limited warranty
with selectable service levels: 9×5 next business day (NBD), 24x7x4, and
24x7x2. Three-year or five-year software support and subscription (matches the
duration of the selected warranty period).
Enclosure: Height: 87 mm (3.4 in), width: 442 mm (17.4 in), depth: 835 mm
(32.9 in) Node: Height: 41 mm (1.6 in), width: 216 mm (8.5 in), depth: 659 mm
(25.9 in) Enclosure: Maximum configuration: 36.9 kg (81 lb) Node: Maximum
configuration: 6.2 kg (13.6 lb)
Factory-integrated models
Factory-integrated models of the Converged HX Series appliances are configured
by using one of the following configuration tools:
Lenovo Enterprise Solutions Configurator (LESC): http://lesc.lenovo.com
System x and Cluster Solutions Configurator (x-config):
http://lesc.lenovo.com/products/hardware/configurator/worldwide/bhui/asit/
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
10
During the configuration process, you are selecting one of the base models
first, and then you are adding components (processors, memory, drives, and
network adapters) to the selected model according to the output from the
Nutanix Sizer tool: http://services.nutanix.com/
Note: You are required to engage a Lenovo representative in the project that
includes the Lenovo Converged HX Series appliances.
The following table lists the base models of the Lenovo Converged HX3000
Series appliances.
Product availability: HX3710 and HX3710-F appliances are withdrawn from
marketing and no longer available for ordering.
Table 4. Base models of the Lenovo Converged HX3000 Series appliances
Description HX3310 Nutanix Appliance HX3310-F Nutanix Appliance HX3510-G
Nutanix Appliance HX3710 Nutanix Appliance HX3710-F Nutanix Appliance
Machine TypeModel 8693-AC2 8693-AC3 8695-AC3 8689-AC1 8689-AC2
The following table lists the default configurations of each appliance.
Table 5. Default configurations
Model HX3310
Intel Xeon processor
2x E5-2650 v4
HX3310-F 2x E5-2680 v4
HX3510-G 2x E5-2680 v4
HX3710 2x E5-2650 v4
HX3710-F 2x E5-2680 v4
Memory
512 GB (16x 32 GB RDIMMs)
512 GB (16x 32 GB RDIMMs)
256 GB (8x 32 GB RDIMMs)
256 GB (8x 32 GB RDIMMs)
256 GB (8x 32 GB RDIMMs)
Storage controller 1x N2215
1x N2215
1x N2215
1x H701-L
1x H701-L
Drives
6x 1 TB 2.5″ HDDs 2x 800 GB 2.5″ SSDs 1x 64 GB Embedded SSD (hypervisor)
8x 800 GB 2.5″ SSDs 1x 64 GB Embedded SSD (hypervisor)
6x 1 TB 2.5″ HDDs 2x 800 GB 2.5″ SSDs 1x 64 GB Embedded SSD (hypervisor)
4x 1 TB 2.5″ HDDs 2x 800 GB 2.5″ SSDs 1x 64 GB Embedded SSD (hypervisor)
6x 800 GB 2.5″ SSDs 1x 64 GB Embedded SSD (hypervisor)
NIC 2x 10 GbE 4x 1 GbE
2x 10 GbE 4x 1 GbE
2x 10 GbE 4x 1 GbE
2x 10 GbE
2x 10 GbE
The Lenovo Converged HX3310 and HX3310-F appliances ship with the following
items:
System documentation Gen II Universal Slides Kit Enterprise 1U Cable
Management Arm (CMA) Two 2.8 m IEC 320-C13 to C14 rack power cables
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
11
The Lenovo Converged HX3310-G appliances ship with the following items:
System documentation Enterprise Slides Kit Enterprise 2U Cable Management Arm
(CMA) Two 2.8 m IEC 320-C13 to C14 rack power cables
The Lenovo Converged HX3710 and HX3710-F appliances ship with the following
items:
System documentation Rail kit (enclosure only) One 2 m 2x IEC 320-C13 to C14
rack power cable (Y-cable) (enclosure only)
It is possible to perform a hardware upgrade after the initial deployment,
such as adding more memory or network adapters, by purchasing the hardware
upgrade option listed in the following table.
Table 6. Hardware upgrade option
Description Nutanix HW Upgrade
Part number Quantity
01KT971 1
Configuration note: You should request a quote for the Nutanix HW Upgrade part number from Lenovo and provide additional details on the existing installation and planned upgrade.
TopSeller models
TopSeller models of the Converged HX Series appliances are pre-configured
bundles that cannot be upgraded with additional options. TopSeller models are
region-specific; that is, each region may define their own models, and not all
models are available in every region.
Product availability: HX Series TopSeller models are available only in North
America.
Note: You are required to engage a Lenovo representative in the project that
includes the Lenovo Converged HX Series appliances.
The following table lists the TopSeller models of the Lenovo Converged HX3000
Series appliances.
Table 7. TopSeller models
Model Intel Xeon number processor
Storage Memory controller Drives
Software
NIC
edition
HX3310
8693E1U 2x E5-2630 v4 128 GB 1x N2215 6x 1 TB 2.5″ HDDs
2x 10 GbE Pro
(8x 16 GB
2x 480 GB 2.5″ SSDs
4x 1 GbE
RDIMMs)
1x Embedded 64 GB SSD (hypervisor)
The HX3310 TopSeller models ship with the following items:
System documentation Gen II Universal Slides Kit Enterprise 1U Cable
Management Arm (CMA) Two 2.8 m IEC 320-C13 to C14 rack power cables
Processors
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
12
Processors
The Lenovo Converged HX3000 Series appliances ship with two processors. The
following table lists the processor options that are available for selection.
Table 8. Processor options
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Description Intel Xeon Processor E5-2620 v4 8C 2.2GHz 20MB Cache 2133MHz 85W Intel Xeon Processor E5-2630 v4 10C 2.2GHz 25MB Cache 2133MHz 85W Intel Xeon Processor E5-2650 v4 12C 2.2GHz 30MB Cache 2400MHz 105W Intel Xeon Processor E5-2680 v4 14C 2.4GHz 35MB Cache 2400MHz 120W Intel Xeon Processor E5-2697 v4 18C 2.3GHz 45MB Cache 2400MHz 145W Intel Xeon Processor E5-2698 v4 20C 2.2GHz 50MB Cache 2400MHz 135W Intel Xeon Processor E5-2699 v4 22C 2.2GHz 55MB Cache 2400MHz 145W
Quantity
2
YNNYN
2
YNYYN
2
YYYYY
2
YYYYY
2
YYYNN
2
NNNYY
2
YYYNN
Memory
The Lenovo Converged HX3000 Series appliances support Lenovo TruDDR4 memory.
TruDDR memory is selected, tested and tuned to maximize performance and
reliability, and it enables extended memory performance features to support
memory speeds that exceed industry standards.
The HX3310, HX3310-F, and HX3510-G appliances support up to 24 DIMMs (12 DIMMs
per processor). Each processor has four memory channels, and there are three
DIMMs per channel.
The HX3710 and HX3710-F appliances support up to 16 DIMMs (8 DIMMs per
processor). Each processor has four memory channels, and there are two DIMMs
per channel.
The appliances support ECC and Chipkill memory protection technologies.
The following table lists the memory options that are available for selection.
Table 9. Memory options
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Selection option Description
RDIMMs
128 GB 16GB TruDDR4 (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM
256 GB 32GB TruDDR4 (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM
384 GB 16GB TruDDR4 (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM
512 GB 32GB TruDDR4 (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM
768 GB 32GB TruDDR4 (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM
Quantity
8
YYYYY
8
YYYYY
24
YYYNN
16
Y Y Y Y Y
24
YYYNN
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
13
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Selection option Description
LRDIMMs
1024 GB 64GB TruDDR4 (4Rx4, 1.2V) PC4-19200 PC4 2400MHz LP LRDIMM
1536 GB 64GB TruDDR4 (4Rx4, 1.2V) PC4-19200 PC4 2400MHz LP LRDIMM
Quantity
16
YYYNN
24
YYYNN
- Not allowed for selection if the Intel Xeon processor E5-2698 v4 is selected.
The following table lists supported memory configurations and maximum operating speeds for the HX3310, HX3310-F, and HX3510-G appliances.
Note: Cells highlighted with a gray background indicate when the number of DIMMs per channel allows the DIMMs to operate faster than Intel specifications define, while still maintaining world-class reliability.
Table 10. HX3310, HX3310-F, and HX3510-G maximum memory speeds
Memory DIMMs per capacity channel RDIMMs 128 GB 1 256 GB 1 384 GB 3 512 GB 2 768 GB 3 LRDIMMs 1024 GB 2 1536 GB 3
Maximum memory speed
2133 MHz memory controller 2400 MHz memory controller
(E5-2620 v4, E5-2630 v4)
(E5-2650 v4, E5-2680 v4, E5-2697 v4, E5-2699 v4)
2133 MHz 2133 MHz 1866 MHz 2133 MHz 1866 MHz
2400 MHz 2400 MHz 1866 MHz 2400 MHz 1866 MHz
2133 MHz 2133 MHz
2400 MHz 2133 MHz
The following table lists supported memory configurations and maximum operating speeds for the HX3710 and HX3710-F appliances.
Table 11. HX3710 and HX3710-F maximum memory speeds
Memory capacity
128 GB 256 GB 512 GB
DIMMs per channel
1 1 2
Maximum memory speed
2133 MHz memory controller (E5-2620 v2, E5-2630 v4)
2400 MHz memory controller (E5-2650 v4, E5-2680 v4, E5-2698 v4)
2133 MHz
2400 MHz
2133 MHz
2400 MHz
2133 MHz
2133 MHz
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
14
Internal storage
The HX3000 Series appliances support the internal drive bay configurations
listed in the following table.
Table 12. Internal drive bay configurations
Model
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Hot-swap front drive bays (main storage)
Quantity, form factor, drive types
Storage controller
8x 2.5-inch: 6x NL SATA HDDs + 2x SATA SSDs
1x N2215
8x 2.5-inch: 8x SATA SSDs
1x N2215
8x 2.5-inch: 8x SATA SSDs; or 6x NL SATA HDDs + 2x SATA SSDs
6x 2.5-inch: 4x NL SATA HDDs + 2x SATA SSDs
6x 2.5-inch: 6x SATA SSDs
1x N2215 1x H701-L 1x H701-L
Hypervisor boot drive
Quantity, form factor, drive type
1x Embedded 64 GB SSD (6 Gbps SATA DOM)
1x Embedded 64 GB SSD (6 Gbps SATA DOM)
1x Embedded 64 GB SSD (6 Gbps SATA DOM)
1x Embedded 64 GB SSD (6 Gbps SATA DOM)
1x Embedded 64 GB SSD (6 Gbps SATA DOM)
Storage controller
Onboard 6 Gbps SATA
Onboard 6 Gbps SATA
Onboard 6 Gbps SATA
Onboard 6 Gbps SATA
Onboard 6 Gbps SATA
The following table summarizes features of the storage controllers.
Table 13. Storage controller features and specifications summary
Feature Form factor Controller chip Host interface Port interface Number of ports Port connectors Drive interface Drive type Drive form factor RAID level Cache
N2215 PCIe low profile LSI SAS3008 PCIe 3.0 x8 12 Gbps SAS 8 2x Mini-SAS HD x4 (SFF-8643) SAS, SATA HDD, SSD SFF, LFF None None
- The H701-L supports up to six drives.
H701-L Mezzanine card LSI SAS2308 PCIe 3.0 x8 6 Gbps SAS 8* 2x Mini-SAS x4 (SFF-8087) SAS, SATA HDD, SSD SFF None (JBOD mode), 0, 1, 10 None
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
15
The following table lists the hard drive options that are available for selection. Table 14. Hard drive options
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Selection option Description
Hard drives without encryption
4 TB
1TB 7.2K 6Gbps NL SATA 2.5″ G3HS HDD
6 TB
1TB 7.2K 6Gbps NL SATA 2.5″ G3HS HDD
8 TB
2TB 7.2K 6Gbps NL SATA 2.5″ G3HS 512e HDD
12 TB 2TB 7.2K 6Gbps NL SATA 2.5″ G3HS 512e HDD
Self-encrypting hard drives
8 TB
2TB 7.2K 12Gbps NL SAS 2.5” G3HS 512e FIPS 140-2 SED
12 TB 2TB 7.2K 12Gbps NL SAS 2.5” G3HS 512e FIPS 140-2 SED
Quantity
4
NNNYN
6
YNYNN
4
NNNYN
6
YNYNN
4
NNNYN
6
YNYNN
The following table lists the solid-state drive options that are available for selection. Table 15. Solid-state drive options
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Selection option Description
Quantity
Solid-state drives without encryption
960 GB Intel S3610 480GB Enterprise Mainstream SATA G3HS 2.5″ SSD 2
YNYYN
1600 GB Intel S3610 800GB Enterprise Mainstream SATA G3HS 2.5″ SSD 2
YNYYN
2400 GB Intel S3610 1.2TB Enterprise Mainstream SATA G3HS 2.5″ SSD 2
YNYYN
2880 GB Intel S3610 480GB Enterprise Mainstream SATA G3HS 2.5″ SSD 6
NNNNY
3200 GB Intel S3610 1.6TB Enterprise Mainstream SATA G3HS 2.5″ SSD 2
YNYYN
3840 GB Intel S3610 480GB Enterprise Mainstream SATA G3HS 2.5″ SSD 8
NYYNN
4800 GB Intel S3610 800GB Enterprise Mainstream SATA G3HS 2.5″ SSD 6
NNNNY
6400 GB Intel S3610 800GB Enterprise Mainstream SATA G3HS 2.5″ SSD 8
NYYNN
7200 GB Intel S3610 1.2TB Enterprise Mainstream SATA G3HS 2.5″ SSD 6
NNNNY
9600 GB Intel S3610 1.2TB Enterprise Mainstream SATA G3HS 2.5″ SSD 8
NYYNN
9600 GB Intel S3610 1.6TB Enterprise Mainstream SATA G3HS 2.5″ SSD 6
NNNNY
12800 GB Intel S3610 1.6TB Enterprise Mainstream SATA G3HS 2.5″ SSD 8
NYYNN
30720 GB PM1633a 3.84TB Enterprise Capacity 12Gb SAS G3HS 2.5″ SSD 8
NYYNN
Self-encrypting solid-state drives
800 GB HGST SSC+ 400GB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 2
YNYYN
1600 GB HGST SSC+ 800GB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 2
YNYYN
2400 GB HGST SSC+ 400GB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 6
NNNNY
3200 GB HGST SSC+ 400GB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 8
NYYNN
3200 GB HGST SSC+ 1.6TB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 2
YNYYN
4800 GB HGST SSC+ 800GB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 6
NNNNY
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
16
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Selection option Description
Quantity
6400 GB HGST SSC+ 800GB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 8
NYYNN
9600 GB HGST SSC+ 1.6TB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 6
NNNNY
12800 GB HGST SSC+ 1.6TB 12Gb SAS FIPS SED 3.5″ Enterprise HS SSD 8
NYYNN
Note: Self-encrypting drives and drives without encryption (HDDs and SSDs)
cannot be intermixed in the same appliance, that is, all drives in the
appliance (HDDs and SSDs) should be either self-encrypting or without
encryption.
Network connectivity
The Lenovo Converged HX3310, HX3310-F, and HX3510-G appliances provide two- or
four-port 10 GbE network connectivity by selecting one or two Intel X520
adapters that provide two 10 GbE ports with SFP+ connectors each, or Intel
X550-T2 adapters that provides two 10 GbE ports with RJ-45 connectors each.
10 GbE ports are bonded with the 1 GbE ports on the system board. The onboard
1 GbE network interface controller (NIC) that is based on the Broadcom BCM5719
chip provides four 10/100/1000 Mb Ethernet ports with RJ-45 connectors.
The Lenovo Converged HX3710 and HX3710-F appliances provide two-port 10 GbE
network connectivity. The Intel X520 10 GbE mezzanine card that is based on
the Intel 82599 NIC chip provides two 10 GbE ports with SFP+ connectors.
Alternatively, two-port 10 GbE network connectivity can be configured by
selecting the Intel X550-T2 PCIe adapter that provides two 10 GbE ports with
RJ-45 connectors.
The following table lists the 10 GbE network adapter options that are
available for selection.
Note: The Intel X520 and X550-T2 adapters cannot be intermixed in the same
appliance, that is, either X520 or X550-T2 adapters can be selected for the
appliance, but not both adapter types.
Table 16. Network adapter options
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Description Intel X520 Dual Port 10GbE SFP+ OCP Mezz (SFP+ connectors) Intel X520 Dual Port 10GbE SFP+ Adapter (SFP+ connectors) Intel X550-T2 Dual Port 10GBase-T Adapter (RJ-45 connectors)
Quantity (min / max)
1 / 1
NNNYY
1 / 2
YYYNN
1 / 2*
Y Y Y Y Y
- The maximum number of adapters supported in the HX3710 or HX3710-F appliances is one.
The following table summarizes features of the 10 GbE network adapters.
Table 17. 10 GbE network adapter features and specifications summary
Feature Form factor Controller chip Host interface Port interface
X520 PCIe low profile or OCP Mezzanine Intel 82559 PCIe 2.0 x8 10 GbE
X550-T2 PCIe low profile Intel X550 PCIe 3.0 x4 10 GbE
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
17
Feature Number of ports Port connector Port speeds
X520 2 SFP+ 10 Gbps
X550-T2 2 RJ-45 100 Mbps, 1 Gbps, 10 Gbps
The SFP+ adapters require SFP+ transceivers or direct-attach copper (DAC) cables that must be ordered separately (two SFP+ transceivers or DAC cables per adapter). The following table lists supported SFP+ transceiver and cable options.
Table 18. SFP+ transceivers and cable options
Description SFP+ transceivers – 10 GbE Lenovo 10GBASE-SR SFP+ Transceiver
QLogic 10Gb SFP+ SR Optical Transceiver Optical cables for 10 GbE SFP+ SR
transceivers Lenovo 0.5m LC-LC OM3 MMF Cable Lenovo 1m LC-LC OM3 MMF Cable
Lenovo 3m LC-LC OM3 MMF Cable Lenovo 5m LC-LC OM3 MMF Cable Lenovo 10m LC-LC
OM3 MMF Cable Lenovo 15m LC-LC OM3 MMF Cable Lenovo 25m LC-LC OM3 MMF Cable
Lenovo 30m LC-LC OM3 MMF Cable SFP+ passive direct-attach cables – 10 GbE
Lenovo 0.5m Passive SFP+ DAC Cable Lenovo 1m Passive SFP+ DAC Cable Lenovo
1.5m Passive SFP+ DAC Cable Lenovo 2m Passive SFP+ DAC Cable Lenovo 3m Passive
SFP+ DAC Cable Lenovo 5m Passive SFP+ DAC Cable Lenovo 7m Passive SFP+ DAC
Cable
Part
Feature Quantity
number code
per adapter
46C3447 5053
2
49Y4218 0064
2
00MN499 ASR5
2
00MN502 ASR6
2
00MN505 ASR7
2
00MN508 ASR8
2
00MN511 ASR9
2
00MN514 ASRA 2
00MN517 ASRB 2
00MN520 ASRC 2
00D6288 A3RG 2
90Y9427 A1PH
2
00AY764 A51N
2
00AY765 A51P
2
90Y9430 A1PJ
2
90Y9433 A1PK
2
00D6151 A3RH 2
GPU adapters
The HX3510-G appliance supports GPU adapter selection options listed in the
following table.
Table 19. GPU adapter selection options
HX3310 HX3310-F HX3510-G HX3710 HX3710-F
Description NVidia Tesla M60 GPU, PCIe (active)
Quantity (min / max)
2 / 2
NNYNN
Hypervisors
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
18
Hypervisors
The Lenovo Converged HX3000 Series appliances support the following
hypervisors:
Nutanix Acropolis Hypervisor (AHV) VMware ESXi 5.5 Update 3 VMware ESXi 6.0
Update 1 VMware ESXi 6.0 Update 2 Microsoft Windows Server 2012 R2 DataCenter
Edition (Hyper-V)
Notes:
The HX Series appliances ship with Nutanix AHV (default) or VMware ESXi
(optional) preloaded. Microsoft Hyper-V is supported as a field-installable
option only.
Software
The Lenovo Converged HX3000 Series appliances can be configured with one of
the Nutanix Software editions that are listed in the following table. The
Starter edition is factory-preloaded and the appropriate license can be
downloaded from the Nutanix website to match the serial number of the
appliance.
Table 20. Nutanix software options
Description Nutanix Starter Edition Nutanix Pro Edition (default selection)
Nutanix Ultimate Edition
Quantity 1 1 1
The Starter edition offers the core set of Nutanix software functionality.
This edition is ideal for small-scale deployments with a limited set of
workloads.
The Pro edition offers rich data services, along with resilience and
management features. This edition is ideal for enterprises running multiple
applications on a Nutanix cluster or with large-scale single workload
deployments.
The Ultimate edition offers the full suite of Nutanix software capabilities to
tackle complex infrastructure challenges. This edition is ideal for multi-site
deployments.
It is possible to upgrade a software edition after the installation by
purchasing one of the software upgrade options listed in the following table.
Table 21. Nutanix software upgrade options
Description Nutanix Starter to Pro Upgrade Nutanix Starter to Ultimate Upgrade
Nutanix Pro to Ultimate Upgrade
Part number 01GU985 01GU986 01GU987
Configuration note: You should request a quote for the selected Nutanix SW Upgrade part number from Lenovo and provide additional details on the existing installation and planned upgrade.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
19
The following table compares features of the Nutanix software editions.
Table 22. Nutanix software editions feature comparison
Feature Enterprise storage Cluster size Heterogeneous clusters VM-centric snapshots and clones Volume groups Data tiering Online cluster grow/shrink Acropolis container services Inline compression Inline performance deduplication MapReduce compression MapReduce deduplication Erasure Coding (EC-X) Acropolis block services Acropolis file services VM Flash Mode (Pin to SSD) Infrastructure resilience Data path redundancy Redundancy factor Availability domains Data protection Asynchronous replication and disaster recovery (DR) Application-consistent snapshots Time Stream (Converged local backups) VSS integration Cloud Connect (Backup to public clouds) Self-service restore Multiple site DR (many to many) Metro availability Synchronous replication and disaster recovery Security Client authentication Cluster lockdown Data-at-rest encryption Management and analytics Prism Starter (Single- and multi-cluster management) Pulse (Automated service agent) Cluster health
Nutanix software edition
Starter
Pro
Ultimate
12 nodes max Yes Yes Yes Yes Yes Yes Yes Yes No No No No No No
Unlimited Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No
Unlimited Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes 2 (Fixed) No
Yes 2 or 3 (Tunable) Yes
Yes 2 or 3 (Tunable) Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
No
No
Yes
Yes
Yes
No
Yes
No
No
Yes Yes Yes*
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
20
Nutanix software edition
Feature
Starter
Pro
One-click upgrades (Nutanix OS and Hypervisor)
Yes
Yes
Rest APIs
No
Yes
Virtualization
VMware vSphere support
Yes
Yes
Microsoft Hyper-V support
Yes
Yes
Built-in Acropolis Hypervisor
Yes
Yes
VM operations
Yes
Yes
Intelligent VM placement
Yes
Yes
Virtual network configuration
Yes
Yes
Host profiles
Yes
Yes
VM high availability
Yes
Yes
Self-service portal
Yes
Yes
- Data-at-rest encryption requires self-encrypting drives (SEDs).
Ultimate Yes Yes
Yes Yes Yes Yes Yes Yes Yes Yes Yes
Systems management
The Lenovo Converged HX3310, HX3310-F, and HX3510-G appliances support the
following systems management tools:
Integrated Management Module Light path diagnostics Lenovo XClarity Nutanix
Prism Lenovo XClarity Energy Manager
The Lenovo Converged HX3710 and HX3710-F appliances support the following
systems management tools:
ThinkServer Management Module Lenovo XClarity Nutanix Prism
Integrated Management Module (HX3310, HX3310-F, HX3510-G)
The Lenovo Converged HX3310, HX3310-F, and HX3510-G appliances contain
Integrated Management Module II (IMM2.1), which provides advanced service-
processor control, monitoring, and an alerting function. If an environmental
condition exceeds a threshold or if a system component fails, the IMM2 lights
LEDs to help you diagnose the problem, records the error in the event log, and
alerts you to the problem. The Integrated Management Module Advanced Upgrade
comes standard with the appliances, and it provides a virtual presence for
remote management capabilities of the appliances.
The IMM provides remote appliance management through industry-standard
interfaces:
Intelligent Platform Management Interface (IPMI) Version 2.0 Simple Network
Management Protocol (SNMP) Version 3 Common Information Model (CIM) Web
browser
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
21
The remote presence feature provides the following functions:
Remotely viewing video with graphics resolutions up to 1600×1200 at 75 Hz with
up to 23 bits per pixel colors, regardless of the system state
Remotely accessing the appliance using the keyboard and mouse from a remote
client
Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote
client, and mapping ISO and diskette image files as virtual drives that are
available for use by the appliance
Uploading a diskette image to the IMM memory and mapping it to the appliance
as a virtual drive
ThinkServer Management Module (HX3710, HX3710-F)
The Lenovo Converged HX3710 and HX3710-F appliances have an integrated
ThinkServer Management Module (TMM), also known as a baseboard management
controller (BMC), for configuration, systems management, and remote control.
The remote presence (remote KVM and media) is a standard function of the TMM.
The remote presence feature provides the following functions:
Remotely viewing video with graphics resolutions up to 1024 x 768, regardless
of the system state
Remotely accessing the server, using the keyboard and mouse from a remote
client
Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote
client, and mapping ISO and diskette image files as virtual drives that are
available for use by the server
Uploading a diskette image to the TMM memory and mapping it to the server as a
virtual drive
The HX3710 and HX3710-F appliances also support IPMI 2.0 for out-of-band
management through the dedicated RJ-45 systems management port. Supported
interfaces include:
Command-line interface (IPMI Shell) The command-line interface provides direct
access to server management functions through the IPMI 2.0 protocol. Use the
command-line interface to issue commands to control the server power, view
system information, and identify the server. You can also save one or more
commands as a text file and run the file as a script.
Serial over LAN Establish a Serial over LAN (SOL) connection to manage servers
from a remote location. You can remotely view and change the UEFI settings,
restart the server, identify the server, and perform other management
functions. Any standard Telnet client application can access the SOL
connection.
Light path diagnostics (HX3310, HX3310-F, HX3510-G)
The Lenovo Converged HX3310, HX3310-F, and HX3510-G appliances include basic
light path diagnostics, which includes system LEDs on the front of the
appliance and LEDs near the monitored components (for example, the DIMM error
LED on the system board).
The Lenovo Converged HX3310, HX3310-F, and HX3510-G appliances also include a
next-gen light path diagnostics LCD display panel. With LCD display, customers
have quick access to system status, firmware, network, and health information.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
22
Lenovo XClarity
Lenovo XClarity is a centralized systems management solution that helps
administrators deliver infrastructure faster. This solution integrates easily
with Lenovo System x M5 and X6 rack servers, Converged HX Series appliances,
and Flex System, providing automated agent-less discovery, monitoring,
firmware updates, configuration management, and bare metal deployment of
operating systems and hypervisors across multiple systems.
Lenovo XClarity is an optional software component for the Lenovo Converged HX
Series appliances which can be used to manage firmware upgrades outside of the
Nutanix Prism software.
Notes:
Lenovo XClarity Administrator can be downloaded and used at no charge to
discover and monitor HX Series appliances and manage firmware upgrades for
them. Optional Lenovo XClarity Pro subscription license that can be selected
in the configurator provides software support for XClarity Administrator and
XClarity Integrators for the duration of the selected warranty period. If
Lenovo XClarity software support is required, the XClarity Pro option must be
selected. For the HX3710 and HX3710-F, Lenovo XClarity only supports
discovery, inventory, and monitoring. Other functions, including firmware
updates and secure connectivity, are not supported.
Lenovo XClarity Administrator is available from Lenovo at no charge, and it
offers the following features:
Auto-discovery, inventory, and monitoring of Converged HX Series appliances
Firmware updates and compliance enforcement External alerts and notifications
via SNMP traps, syslog remote logging, and e-mail Secure connections to
managed endpoints NIST 800-131A or FIPS 140-2 compliant cryptographic
standards between the management solution and managed endpoints Integration
into existing higher level management systems such as cloud automation and
orchestration tools through REST APIs, providing extensive external visibility
and control over hardware resources An intuitive, easy-to-use GUI Scripting
support with Windows PowerShell, providing command-line visibility and control
over hardware resources
In addition, Lenovo XClarity Administrator offers two software plug-in modules
(Lenovo XClarity Integrators) at no charge:
Lenovo XClarity Integrator for Microsoft System Center Lenovo XClarity
Integrator for VMware vCenter
Lenovo XClarity Integrators allow administrators to manage physical
infrastructure from leading external virtualization management software tools
from Microsoft and VMware.
Note: The HX3710 and HX3710-F appliances do not support Lenovo XClarity
Integrators.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
23
Lenovo XClarity Integrators offer the following additional features:
Ability to discover, manage, and monitor Lenovo server hardware from VMware
vCenter or Microsoft System Center
Deployment of firmware updates to Converged HX Series appliances from the
virtualization management tool
Non-disruptive server maintenance in clustered environments that reduces
workload downtime by dynamically migrating workloads from affected hosts
during rolling server updates or reboots
Greater service level uptime and assurance in clustered environments during
unplanned hardware events by dynamically triggering workload migration from
impacted hosts when impending hardware failures are predicted
Nutanix Prism
Nutanix Prism gives administrators a simple and elegant way to manage virtual
environments. Powered by advanced data analytics and heuristics, Prism
simplifies and streamlines common workflows within a datacenter eliminating
the need to have disparate management solutions.
Nutanix Prism is a part of the Nutanix software preloaded on the appliances,
and it includes the following components:
Prism Starter (included in Starter, Pro, and Ultimate Nutanix software
editions): Provides ability to configure, manage, and monitor a Nutanix
cluster and centralized management of multiple local and remote Nutanix
clusters.
Prism Pro (Selectable software license; optional): Enables efficiency
evaluation, capacity planning, expansion recommendations, custom dashboards,
and advanced search capabilities.
The Prism Pro software license can be selected during the initial purchase.
Also, Prism Starter can be upgraded to Prism Pro after the initial deployment
by purchasing one of the software license options listed in the following
table.
Table 23. Prism Pro software license options
Description Nutanix Prism Pro with 1Yr Support Nutanix Prism Pro with 2Yr
Support Nutanix Prism Pro with 3Yr Support Nutanix Prism Pro with 4Yr Support
Nutanix Prism Pro with 5Yr Support
Part number Quantity 01GU988 1 01GU989 1 01GU990 1 01GU991 1 01GU992 1
Configuration note: You should request a quote for the selected Prism Pro part number from Lenovo and provide additional details on the existing installation.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
24
Nutanix Prism offers the following features:
Single point of control Accelerates enterprise-wide deployment Manages
capacity centrally Adds nodes in minutes Supports non-disruptive software
upgrades with zero downtime Integrates with REST APIs and PowerShell
Monitoring and alerting Tracks infrastructure utilization (storage, processor,
memory) Centrally monitors multiple clusters across multiple sites Monitors
per-VM performance and resource usage Checks system health Generates alerts
and notifications
Integrated data protection Offers customizable RPO/RTO and retention policies
Supports configurable per-VM replication (1:1, 1:many and many:1) Provides
efficient VM recovery Deploys affordable DR and backup to the cloud
Diagnostics and troubleshooting Provides time-based historical views of VM
activity Performs proactive alert analysis Correlates alerts and events to
quickly diagnose issues Generates actionable alerts and reduces resolution
times Analyzes trending patterns for accurate capacity planning
Lenovo XClarity Energy Manager (HX3310, HX3310-F, HX3510-G)
Lenovo XClarity Energy Manager provides a stand-alone, web-based agent-less
power management console that provides real time data and enables you to
observe, plan and manage power and cooling for Lenovo servers. Using built-in
intelligence, it identifies server power consumption trends and ideal power
settings and performs cooling analysis so that you can define and optimize
power-saving policies.
Lenovo XClarity Energy Manager offers the following capabilities:
Reports vital server information, such as power, temperature and resource
utilization Monitors inlet temperature to locate hot spots, reducing the risk
of data or device damage Provides finely-grained controls to limit platform
power in compliance with IT policy Generates alerts when a user-defined
threshold is reached
Lenovo XClarity Energy Manager is an optional, separately orderable software
component for the Lenovo Converged HX Series appliances that is licensed on a
per managed node basis; that is, each managed system requires a license.
The following table lists the geo-specific Lenovo XClarity Energy Manager
software license options.
Note: Lenovo XClarity Energy Manager does not support HX3710 and HX3710-F
appliances.
Table 24. Lenovo XClarity Energy Manager software options
Description Lenovo XClarity Energy Manager, 1 Node w/ 1 Yr S&S Lenovo XClarity
Energy Manager, 5 Nodes w/ 1 Yr S&S Lenovo XClarity Energy Manager, 50 Nodes
w/ 1 Yr S&S * NA = North America; AP = Asia Pacific ** EMEA = Europe, Middle
East, Africa; LA = Latin America
Part number (NA, AP, Japan)*
01DA225 01DA226 01DA227
Part number (EMEA, LA)**
01DA228 01DA229 01DA230
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
25
Physical specifications
The Lenovo Converged HX3310 and HX3310-F appliances have the following
dimensions and weight (approximate):
Height: 43 mm (1.7 in.) Width: 434 mm (17.1 in.) Depth: 734 mm (28.9 in.)
Weight (maximum): 19.3 kg (42.5 lb)
The Lenovo Converged HX3510-G appliances have the following dimensions and
weight (approximate):
Height: 87 mm (3.4 in.) Width: 446 mm (17.5 in.) Depth: 800 mm (31.5 in.)
Weight (maximum): 34 kg (75 lb)
The Lenovo Converged HX3710 and HX3710-F appliances have the following
dimensions and weight (approximate):
Enclosure Height: 87 mm (3.4 in.) Width: 442 mm (17.4 in.) Depth: 835 mm (32.9
in.) Weight (maximum): 36.9 kg (81 lb)
Node Height: 41 mm (1.6 in.) Width: 216 mm (8.5 in.) Depth: 659 mm (25.9 in.)
Weight (maximum): 6.2 kg (13.6 lb)
Operating environment
The HX3310, HX3310-F, and HX3510-G appliances are supported in the following
environment:
Air temperature: System on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to
950 m (3,117 ft); decrease the maximum system temperature by 1 °C for every
175-m increase in altitude above 950 m. System off: 5 °C to 45 °C (41 °F to
113 °F) Shipment: -40 °C to +60 °C (-40 °F to 140 °F) at up to 10,700 m
(35,105 ft)
Maximum altitude: 3,050 m (10,000 ft) at 5 °C to 28 °C (41 °F to 82 °F)
Humidity: System on: 8% to 85%, maximum dew point 24 °C, maximum rate of
change 5 °C/hr System off: 8% to 85%, maximum dew point 27 °C
Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with
relaxed support: Supports cloud-like workload with no performance degradation
acceptable (Turbo-Off). Under no circumstance can any combination of worst-
case workload and configuration result in system shutdown or design exposure
at 40 °C. The worst-case workload (like Linpack, Turbo-On) might have
performance degradation.
Electrical: HX3310 and HX3310-F: 100 to 127 (nominal) V AC; 50 Hz or 60 Hz;
10.4 A 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 5.0 A Input kilovolt-amperes
(kVA) (approximately): 1.192 kVA HX3510-G: 200 to 240 (nominal) V AC; 50 Hz or
60 Hz; 7.2 A Input kilovolt-amperes (kVA) (approximately): 1.671 kVA
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
26
BTU output (maximum): HX3310 and HX3310-F: 4026 Btu/hr (1180 watts) HX3510-G:
5643 Btu/hr (1654 watts)
Noise level: 6.6 bels (operating) 6.4 bels (idle)
The HX3710 and HX3710-F appliances are supported in the following environment:
Air temperature: System on: 10 °C to 35 °C (50 °F to 95 °F); altitude: 0 to
950 m (3,117 ft); decrease the maximum system temperature by 1 °C for every
300-m increase in altitude above 950 m. System off: 5 °C to 45 °C (41 °F to
113 °F) Shipment: -40 °C to +60 °C (-40 °F to 140 °F) at up to 10,700 m
(35,105 ft)
Maximum altitude: 3,050 m (10,000 ft) at 10 °C to 28 °C (50 °F to 82 °F)
Humidity: System on: 20% to 80%, maximum dew point 21 °C (70 °F), maximum rate
of change 20 °C/hr System off: 8% to 80%, maximum dew point 27 °C (80.6°F)
Shipment: 5% to 100%, maximum dew point 29 °C (84.2°F)
Electrical: 200 to 240 (nominal) V AC; 50 Hz or 60 Hz; 9.6 A Input kilovolt-
amperes (kVA) (approximately): 1.916 kVA
BTU output (maximum): 6473 Btu/hr (1897 watts)
Noise level: 6.8 bels (operating) 6.2 bels (idle)
Regulatory compliance
The Lenovo Converged HX3000 Series appliances conform to the following
regulations:
AS/NZS CISPR 22, Class A (Australia/New Zealand) BSMI CNS 13438, Class A; CNS
14336 (Taiwan) CCC GB 4943.1, GB 17625.1, GB 9254 Class A (China) CE Mark
(European Union) CISPR 22, Class A EAC (Russia) EN 55022, Class A EN 55024
EN/IEC 61000-3-2 EN/IEC 61000-3-3 EN/IEC/CSA/UL 60950-1 Energy Star 2.0 FCC
Part 15, Class A (United States) GS/TUV (Germany) ICES-003/NMB-03, Class A
(Canada) MSIP (Korea) NOM-019 (Mexico) Reduction of Hazardous Substances
(ROHS) TUV S (Argentina) VCCI, Class A (Japan)
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
27
Hardware warranty
The Lenovo Converged HX3000 Series appliances can be configured with a three-
year or five-year hardware warranty and software support with standard call
center support and various levels of coverage with a well-defined scope of
services, including service hours, response time, term of service, and service
agreement terms and conditions.
The Lenovo local support centers perform problem determination and resolution
for hardware-related issues and escalate to Nutanix, on behalf of the
customer, for software-related problem determination. Nutanix will contact the
customer and will own the software-related problem resolution until closure.
Note: Lenovo warranty service coverage levels are region-specific. Not all
warranty service levels are available in every region.
The following table explains warranty service definitions in more detail.
Table 25. Warranty service definitions
Term
Description
Onsite Service
If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location.
Parts Delivered
If a problem with your product cannot be resolved via telephone and a CRU part is required, Lenovo will send a replacement CRU to arrive at your location. If a problem with your product cannot be resolved via telephone and a FRU part is required, a Service Technician will be dispatched to arrive at your location.
Technician If a problem with your product cannot be resolved via telephone, a Service Technician will be Installed dispatched to arrive at your location. Parts
Hours of coverage
9×5: 9 hours per day, 5 days per week, during normal business hours, excluding local public and national holidays
24×7: 24 hours per day, 7 days per week, 365 days per year.
Response 2 hours, 4 hours, or Next Business Day: The time period from when the
telephone based time target troubleshooting is completed and logged, to the
delivery of the CRU or arrival of a Service Technician
and part at the Customer’s location for repair.
Committed 6 hours: The time period between the service request registration in Lenovo’s call management
Repair
system and the restoration of the product to conformance with its specification by a Service
Technician.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
28
In general, the following Lenovo warranty service levels are available for the
Converged HX Series appliances:
Three or five years of 9×5 or 24×7 service coverage
Parts delivered or technician installed parts from next business day to 4 or 2
hours
Committed Service Repair Committed Service Repair (CSR) enhances the level of
Warranty Service Upgrade or Post Warranty/Maintenance Service offering
associated with the selected systems. Offerings vary and are available in
select regions.
Priority handling to meet defined time frames to restore the failing machine
to good working condition 24x7x6 committed repair: Service performed 24 hours
per day, 7 days per week, within 6 hours
YourDrive YourData Lenovo’s YourDrive YourData service is a multi-drive
retention offering that ensures your data is always under your control,
regardless of the number of drives that are installed in your Lenovo server.
In the unlikely event of a drive failure, you retain possession of your drive
while Lenovo replaces the failed drive part. Your data stays safely on your
premises, in your hands. The YourDrive YourData service can be purchased in
convenient bundles with Lenovo warranty upgrades and extensions.
Software maintenance
The Lenovo Converged HX3000 Series appliances include a three-year or five-
year software support and subscription (matches the duration of the selected
hardware warranty period) that entitles you to submit service requests to
troubleshoot Nutanix software issues and receive code updates, including
fixes, patches, and new software releases.
The Lenovo local support centers perform problem determination and resolution
for hardware-related issues and escalate to Nutanix, on behalf of the
customer, for software-related problem determination. Nutanix will contact the
customer and will own the software-related problem resolution until closure.
Software support that is provided by Nutanix includes 24×7 phone and web
coverage with the following target response times (priorities are assigned by
Nutanix based on the impact on productivity):
Priority 1 (Emergency: Productivity halted): 2 hours Priority 2 (Critical:
Significant impact on productivity): 4 hours Priority 3 (Normal: Minimal
impact on productivity): 8 hours (by next business day)
Ethernet LAN switches
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
29
Ethernet LAN switches
The following table lists the Ethernet LAN switches that are offered by Lenovo
that can be used in Lenovo Converged HX Series solutions.
Table 26. Ethernet LAN switches
Description
Part
Feature
number code
1 Gb Ethernet switches (IPMI management and 1 GbE host connectivity)
Lenovo RackSwitch G7028 (Rear to Front)
7159BAX AT09
Lenovo RackSwitch G7052 (Rear to Front)
7159CAX AT0A
Lenovo RackSwitch G8052 (Rear to Front)
7159G52 ASY2
10 Gb Ethernet switches (10 GbE host connectivity)
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159A1X AU3A
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7159B1X AU38
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159C1X AU36
Lenovo RackSwitch G8124E (Rear to Front)
7159BR6 AT0B
Lenovo RackSwitch G8272 (Rear to Front)
7159CRW ASRD
Lenovo RackSwitch G8296 (Rear to Front)
7159GR6 ASVM
40 Gb Ethernet switches (40 GbE aggregation layer; 10 GbE breakout host connectivity)
Lenovo RackSwitch G8332 (Rear to Front)
7159BRX ASY4
100 Gb Ethernet switches (40 GbE/100 GbE aggregation layer; 10 GbE breakout host connectivity)
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)
7159D1X AV17
For more information, see the list of Product Guides in the Top-of-rack Switches category: http://lenovopress.com/servers/options/switches
Rack cabinets
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
30
Rack cabinets
The following table lists the rack cabinets that are offered by Lenovo that
can be used in Lenovo Converged HX Series solutions.
Table 27. Rack cabinets
Description 25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 25U
Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) 42U S2
Standard Rack (1000 mm deep; 6 sidewall compartments) 42U 1100mm Enterprise V2
Dynamic Rack (6 sidewall compartments) 42U 1100mm Enterprise V2 Dynamic
Expansion Rack (6 sidewall compartments) 42U 1200mm Deep Dynamic Rack (6
sidewall compartments) 42U 1200mm Deep Static Rack (6 sidewall compartments)
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) 42U Enterprise
Expansion Rack (1105 mm deep; 4 sidewall compartments)
Part
Feature
number code
93072RX 1042
93072PX 6690
93074RX 1043
93634PX A1RC
93634EX A1RD
93604PX 7649
93614PX 7651
93084PX 5621
93084EX 5622
For more information, see the list of Product Guides in the Rack Cabinets category: http://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in Lenovo Converged HX Series solutions.
Table 28. Power distribution units
Description 0U Basic PDUs 0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord 0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord 0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 cord 0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord Switched and Monitored PDUs 0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P cord 0U 20 C13/4 C19 Switched / Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 cord 0U 18 C13/6 C19 Sw. / Mon. 32A/200-240/346-415V/3Ph PDU w/ IEC60309 532P6 cord 0U 12 C13/12 C19 Switched / Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 cord 1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) 1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord 1U 12 C13 Switched and Monitored DPI PDU (without line cord) 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) Ultra Density Enterprise C19/C13 PDU Module (without line cord) Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord
Part
Feature
number code
00YJ776 00YJ777 00YJ778 00YJ779
ATZY ATZZ AU00 ATZX
00YJ781 AU03 00YJ780 AU01 00YJ782 AU02 00YJ783 AU04 46M4002 5896 46M4003 5897 46M4004 5894 46M4005 5895
71762NX 6050 71763NU 6051
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
31
Description C13 Enterprise PDUs (12x IEC 320 C13 outlets) DPI C13 Enterprise PDU+ (without line cord) DPI Single Phase C13 Enterprise PDU (without line cord) C19 Enterprise PDUs (6x IEC 320 C19 outlets) DPI Single Phase C19 Enterprise PDU (without line cord) DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord Front-end PDUs (3x IEC 320 C19 outlets) DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord Universal PDUs (7x IEC 320 C13 outlets) DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) NEMA PDUs (6x NEMA 5-15R outlets) DPI 100-127V PDU with fixed NEMA L5-15P line cord Line cords for PDUs that ship without a line cord DPI 30a Line Cord (NEMA L6-30P) DPI 32a Line Cord (IEC 309 P+N+G) DPI 32a Line Cord (IEC 309 3P+N+G) DPI 60a Cord (IEC 309 2P+G) DPI 63a Cord (IEC 309 P+N+G) DPI Australian/NZ 3112 Line Cord (32A) DPI Korean 8305 Line Cord (30A)
Part
Feature
number code
39M2816 6030 39Y8941 6010
39Y8948 6060 39Y8923 6061
39Y8938 39Y8939 39Y8934 39Y8940 39Y8935
6002 6003 6005 6004 6006
00YE443 5950
39Y8905 5900
40K9614 40K9612 40K9611 40K9615 40K9613 40K9617 40K9618
6500 6502 6504 6501 6503 6505 6506
For more information, see the list of Product Guides in the Power Distribution Units category: http://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
32
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that
are offered by Lenovo that can be used in Lenovo Converged HX Series
solutions.
Table 29. Uninterruptible power supply units
Description RT1.5kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-15R 12A outlets) RT1.5kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A outlets) RT2.2kVA 2U Rack or Tower UPS (100-125VAC) (8x NEMA 5-20R 16A outlets) RT2.2kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x C19 16A outlets) RT3kVA 2U Rack or Tower UPS (100-125VAC) (6x NEMA 5-20R 16A, 1x L5-30R 24A outlets) RT3kVA 2U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 1x C19 16A outlets) RT5kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x C19 16A outlets) RT6kVA 3U Rack or Tower UPS (200-240VAC) (8x IEC 320 C13 10A, 2x C19 16A outlets) RT8kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) RT11kVA 6U Rack or Tower UPS (200-240VAC) (4x IEC 320-C19 16A outlets) RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets) RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) (4x IEC 320-C19 16A outlets)
Part
Feature
number code
55941AX A53S
55941KX A53T
55942AX A53U
55942KX A53V
55943AX A53W
55943KX A53X 55945KX A540 55946KX A541 55948KX A543 55949KX A544 55948PX A546 55949PX A547
For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category: http://lenovopress.com/servers/options/ups
Lenovo Financial Services
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
33
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering
products and services that are recognized for their quality, excellence, and
trustworthiness. Lenovo Financial Services offers financing solutions and
services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers
like you who want to maximize your purchase power by obtaining the technology
you need today, protect against technology obsolescence, and preserve your
capital for other uses.
We work with businesses, non-profit organizations, governments and educational
institutions to finance their entire technology solution. We focus on making
it easy to do business with us. Our highly experienced team of finance
professionals operates in a work culture that emphasizes the importance of
providing outstanding customer service. Our systems, processes and flexible
policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle
everything you need from hardware and software to service contracts,
installation costs, training fees, and sales tax. If you decide weeks or
months later to add to your solution, we can consolidate everything into a
single invoice.
Our Premier Client services provide large accounts with special handling
services to ensure these complex transactions are serviced properly. As a
premier client, you have a dedicated finance specialist who manages your
account through its life, from first invoice through asset return or purchase.
This specialist develops an in-depth understanding of your invoice and payment
requirements. For you, this dedication provides a high-quality, easy, and
positive financing experience.
For your region specific offers please ask your Lenovo sales representative or
your technology provider about the use of Lenovo Financial Services. For more
information, see the following Lenovo website: http://www.lenovofs.com
Related publications and links
For more information, see these resources:
Lenovo Converged HX Series appliances product page
http://www3.lenovo.com/us/en/p/WMD00000036
Lenovo Enterprise Solutions Configurator (LESC): http://lesc.lenovo.com
System x and Cluster Solutions Configurator (x-config)
http://lesc.lenovo.com/products/hardware/configurator/worldwide/bhui/asit/
Nutanix documentation http://portal.nutanix.com/#/page/docs
Lenovo Data Center Support http://datacentersupport.lenovo.com
Lenovo Converged HX Series TCO Calculator http://lenovo-hx.esgcalculator.com
Lenovo Hyperconverged Decision Tool http://www.lenovo.com/hxdecisiontool
Related product families
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
34
Related product families
Product families related to this document are the following: ThinkAgile HX
Series for Nutanix Nutanix Alliance Hyperconverged Infrastructure
Hyperconverged Infrastructure
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
35
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only that Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc. 8001 Development Drive Morrisville, NC 27560
U.S.A. Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, LP0505, was created or updated on October 8, 2018.
Send us your comments in one of the following ways:
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/LP0505
Send your comments in an e-mail to: comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/LP0505.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
36
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both: Lenovo® Flex System RackSwitch System x® ThinkAgile®
ThinkServer® ThinkSystem® TopSeller TruDDR4 XClarity®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries.
Hyper-V®, Microsoft®, PowerShell, Windows PowerShell®, Windows Server®, and
Windows® are trademarks of Microsoft Corporation in the United States, other
countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances (withdrawn product)
37
References
- Home - Data Center Support - Lenovo Support US
- Power Distribution Units > Lenovo Press
- Rack Cabinets > Lenovo Press
- Top-of-Rack Switches > Lenovo Press
- Uninterruptible Power Supplies > Lenovo Press
- System x and Cluster Solutions configurator (x-config)
- Nutanix Support & Insights
- Nutanix Sizer
- Lenovo Financial Services | Lenovo US
- Lenovo Converged HX3310, HX3310-F, HX3510-G, HX3710, and HX3710-F Appliances Product Guide (withdrawn product) > Lenovo Press
- Hyperconverged Infrastructure > Lenovo Press
- ThinkAgile HX Series for Nutanix > Lenovo Press
- Nutanix Alliance > Lenovo Press
- Hyperconverged Infrastructure > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>