Lenovo Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex Owner’s Manual
- October 27, 2023
- Lenovo
Table of Contents
Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex
Owner’s Manual (withdrawn product)
Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex
Chelsio single-port and dual-port adapters for IBM System Cluster 1350 and IBM
iDataPlex are 10 Gigabit Ethernet adapters with PCI Express host bus interface
optimized for virtualization, high performance computing, and storage
applications. The third generation technology from Chelsio provides the
highest 10GbE performance that is available and dramatically lowers host
system CPU communications overhead.
With on-board hardware that off-loads TCP/IP, iSCSI, and iWARP RDMA processing
from its host system, these adapters free up host CPU cycles for business
applications and result in increased bandwidth, lower latency, and lower
power. This combination makes it practical to converge other networks that
traditionally used niche technologies onto 10GbE. High bandwidth and extremely
low latency make 10GbE with protocol offload the best technology for high-
performance cluster computing (HPCC) fabrics.
![Lenovo Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex
- Figure 1](https://manuals.plus/wp-content/uploads/2022/11/Lenovo-Chelsio- 10GbE-Adapters-for-IBM-System-Cluster-1350-and-IBM-iDataPlex-Figure-1.jpg)
Did you know?
These Chelsio adapters enable the concept of unified wire, the convergence of
server networking, storage networking, and cluster computing interconnects
onto a single platform and a single fabric.
These Chelsio adapters are part of the IBM System Cluster 1350 solution. The
Cluster 1350 is your key to a fully integrated HPC solution. IBM clustering
solutions include servers, storage, and industry-leading interconnects that
are factory-integrated, fully tested, and delivered to your door, ready to
plug into your data center, all with a single point of contact for support.
Click here to check for updates
Part number information
Table 1. Ordering part number and feature code
Description| IBM part number| Feature code| Chelsio part
number
---|---|---|---
Chelsio S310E Single-port 10GbE PCIe x8 Adapter| 59Y1952| 5761| S310E-CR
Chelsio S310E Single-port 10GbE PCIe x8 Adapter (SFP+ connector)| 46M1809|
5493| S310E-SR+
Chelsio S310E Single-port 10GbE PCIe x8 Adapter (CX4 connector)| 46M1813|
5494| S310E-CXA
Chelsio S320E Dual-port 10GbE PCIe x8 Adapter| 59Y1956| 5762| S320E-CR
Chelsio 10GbE Expansion Card (CFFh) for BladeCenter| 46M1817| 5495| S320EM-BCH
![Lenovo Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex
- Figure 2](https://manuals.plus/wp-content/uploads/2022/11/Lenovo-Chelsio- 10GbE-Adapters-for-IBM-System-Cluster-1350-and-IBM-iDataPlex-Figure-2.jpg)
Features
These Chelsio single-port and dual-port adapters for IBM System 1350 and iDataPlex have following features:
- Unified Wire interconnect solution for server networking, storage networking, and clustering on asingle platform
- Very low latency Ethernet
- Reduces host CPU utilization by up to 90% compared to NICs without full offload capabilities
- PCI Express 1.1 x8 host bus interface
- Line-rate 10Gbps full-duplex performance
- Integrated traffic manager, QoS, and virtualization capabilities
- TCP sockets, SCSI, RNIC-PI, kDAPL, and Open Fabrics 1.3 software interfaces
- Ideal fit for scale up servers and NAS systems
- Consolidate LAN, SAN, and cluster networks
- Enable high performance NAS systems and Ethernet-based IP SANs
- Deploy Ethernet-only IP SANs throughout the enterprise beyond the data center
- Develop shared-storage systems providing both file- and block-level services
- Deploy Ethernet-only networking for cluster fabric, LAN, and SAN
- Full TCP offload, iSCSI, and iWARP RDMA plus direct data placement (DDP)
- Increase cluster fabric bandwidth and deploy Ethernet-only networking for cluster fabric, LAN, and SAN
Table 2 compares the adapters.
Table 2. Comparison of the adapter cards
Feature| Single-port CR| Single-port SR+| Single-port CXA|
Dual-port CR| Dual-port CFFh
---|---|---|---|---|---
Part number| 59Y1952| 46M1809| 46M1813| 59Y1956| 46M1817
Form factor| Low profile PCIe card| Low profile PCIe card| Low profile PCIe
card| Half-length PCIe card| BladeCenter CFFh
Ports| 1| 1| 1| 2| 2
Connector(s)| SFP+ cage| SFP+| CX4| SFP+ cage| CFFh connector
Power consumption| 16.7W| 17W| 16W| 21.7W| 16W
- These cards support the use of SFP+ transceivers or twinax direct-attach cables (DACs)
Specifications
The Chelsio single-port and dual-port adapters for Cluster 1350 and iDataPlex
have the following features:
Network Interfaces:
- 10GBASE-SR short-reach optics (850nm)
- 10GBASE-LR long-reach optics (1310nm)
- 10GBASE-CX short-reach copper
Ethernet:
- IEEE 802.3ae (10GbE)
- IEEE 802.1p Priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- IEEE 802.3ad link aggregation
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo Frames up to 9.6 KB
Stateless Offloads:
- TCP checksum offload for IPv4 & IPv6
- TCP Segmentation Offload (TSO) for IPv4 & IPv6
- Large Receive Offload (LRO) for IPv4 & IPv6
- Large Send Offload (LSO) for IPv4 & IPv6
- UDP checksum offload for IPv4 & IPv6
- Receive Side Scaling and packet steering
- Line rate packet filtering and attack protection
TCP/IP Full Offload:
- Full TCP implementation including exceptions
- High performance even during packet loss
- Extensive RFC compliance, fully featured stack
- Zero copy on Tx and Rx
- Direct Data Placement (DDP)
- Up to 64 K simultaneous connections capacity
Integrated Traffic Manager:
- Multiple Tx & Rx queues with QoS
- Simultaneous low latency and high bandwidth
- Per-connection and per-class rate control
- Packet loss avoidance
Virtualization and Firewall:
- Rule-based packet steering and filtering capability
iSCSI Acceleration:
- Full iSCSI initiator and target mode stack
- Header and Data Digest (CRC) generation and checking
- PDU recovery
- Direct Data Placement (DDP)
High Performance RDMA:
- Ultra-low latency, line rate bandwidth
- IETF RDDP and RDMAC iWARP compliance
- APIs: RNIC-PI, kDAPL and OpenFabrics 1.3
Physical specifications
The three single-port adapters have the following physical specifications:
- Width: 168 mm (6.60 in)
- Height: 64 mm (2.52 in)
- Depth: 18 mm (0.69 in)
The S320E dual-port 10GbE adapter has the following physical specifications:
- Width: 168 mm (6.60 in)
- Height: 107 mm (2.52 in)
- Depth: 18 mm (0.69 in)
![Lenovo Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex
- Figure 4](https://manuals.plus/wp-content/uploads/2022/11/Lenovo-Chelsio- 10GbE-Adapters-for-IBM-System-Cluster-1350-and-IBM-iDataPlex-Figure-4.jpg)
Operating environment
This adapter is supported in the following environment:
- Temperature (operating): 0° to 55° C (32° to 131° F)
- Humidity (operating): 5 to 95%, non-condensing
- Airflow: 200 lf/m
Supported servers
The Chelsio single-port and dual-port adapters are supported in the IBM
servers that are listed in Table 3.
Table 3. Supported servers in the 1350 program
| | x3550 M2| x3650 M2| x3755| iDataPlex dx360 M2|
HS22| LS22| LS42| JS23/JS43
---|---|---|---|---|---|---|---|---|---
Chelsio S310E Single-port 10GbE PCIe x8 Adapter| 59Y1952| Y| Y| Y| Y| N| N| N|
N
Chelsio S310E Single-port 10GbE PCIe x8 Adapter (SFP+ connector)| 46M1809| Y|
Y| Y| Y| N| N| N| N
Chelsio S310E Single-port 10GbE PCIe x8 Adapter (CX4 connector)| 46M1813| Y|
Y| Y| Y| N| N| N| N
Chelsio S320E Dual-port 10GbE PCIe x8 Adapter| 59Y1956| Y| Y| Y| Y| N| N| N| N
Chelsio 10GbE Expansion Card (CFFh) for BladeCenter| 46M1817| N| N| N| N| Y|
Y| Y| Y
Supported operating systems
The Chelsio adapters support the following operating systems (including
support for both TOE and NIC mode, unless otherwise stated):
- FreeBSD
- Kernel.org Linux-2.6.9, 2.6.12, and 2.6.20
- Red Hat Enterprise Linux 3 base kernel (NIC only, no TOE support).
- Red Hat Enterprise Linux 4 U3, U4, U5, U6, U7, and U8
- Red Hat Enterprise Linux 5 base, U1, U2, U3, and U4
- Solaris and Open Solaris
- SUSE Linux Enterprise Server 9 SP3 (NIC only, no TOE support)
- SUSE Linux Enterprise Server 10 base, SP1, SP2 and SP3
- SUSE Linux Enterprise Server 11 base
- Microsoft Windows Server 2003 SP2 (x64)
- Microsoft Windows Server 2008 R2 (x64)
- VMware ESX/ESXi 3.5
- VMware ESX/ESXi 4.0
See Chelsio driver README file for the latest information about the specific versions and service packs that are supported, available from: http://www.chelsio.com/support
Related publications
For more information, refer to these resources:
-
Chelsio Adapters driver download, Installation, Configuration, troubleshooting, support
http://service.chelsio.com/ibm.html -
IBM iDataplex and Cluster 1350 – Drivers, Firmware, and Software (Red Hat 5.3)
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5082806 -
IBM Announcement Letter
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS108-880 -
IBM Announcement Letter
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS109-722 -
IBM System Cluster 1350 Information Center
http://publib.boulder.ibm.com/cluster/
Related product families
Product families related to this document are the following:
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only that Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications
covering subject matter described in this document. The furnishing of this
document does not give you any license to these patents. You can send license
inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimer of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time
without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS0767, was created or updated on March 26, 2010.
Send us your comments in one of the following ways:
-
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/TIPS0767 -
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at
https://lenovopress.lenovo.com/TIPS0767.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo
in the United States, other countries, or both. A current list of Lenovo
trademarks is available on the Web at
https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
BladeCenter®
iDataPlex®
The following terms are trademarks of other companies:
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft
Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of
others.
References
- IBM Support
- The Linux Kernel Archives
- Page Redirection
- Support | Chelsio Communications
- 10 Gb Ethernet Connectivity > Lenovo Press
- Ethernet Adapters > Lenovo Press
- Chelsio 10GbE Adapters for IBM System Cluster 1350 and IBM iDataPlex Product Guide (withdrawn product) > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>