Lenovo Brocade Converged 10GbE Switch Module for BladeCenter Owner’s Manual

October 27, 2023
Lenovo

Lenovo Brocade Converged 10GbE Switch Module for BladeCenter Owner’s Manual

Introduction

The Brocade Converged 10GbE Switch Module and Brocade 2-Port 10Gb Converged Network Adapter are part of a leading Converged Ethernet solution for BladeCenter that offers Fibre Channel investment protection, maximum bandwidth and performance, and simplicity in a converged environment. The Brocade Converged 10GbE Switch Module also features Dynamic Ports on Demand capability through the Port Upgrade Key. This capability allows you to enable any combination of Fibre Channel and Ethernet ports based on your infrastructure requirements, and to experience Converged Ethernet benefits without significant investment.

With the base model Converged 10GbE Switch Module, you can enable 16 of the 30 ports on the switch (eight 10Gb CEE external ports, eight 8Gb FC external ports, and 14x 10Gb CEE internal ports). If you purchase the Port Upgrade Key, you can enable all 30 ports on the Switch Module for a fully realized Converged Ethernet solution.

Figure 1 shows the switch module.
Product Overview
Figure 1. Brocade Converged 10GbE Switch Module for BladeCenter

Did you know?

The Brocade CNAs and Brocade Converged 10GbE Switch Modules for BladeCenter are the industry’s first truly converged FCoE BladeCenter solution with native Fibre Channel and Ethernet ports built into a single switch module. The converged switch module provides up-front reduction in SAN/LAN cost and complexity. It requires fewer adapters, switch modules and cabling, which means an up-front reduction in your network investment.

Part number information

Table 1 lists the part numbers to order these modules and additional options for them.
Table 1. IBM part numbers and feature codes for ordering

Description

| IBM part number|

IBM feature code

---|---|---
Brocade Converged 10GbE Switch Module for BladeCenter| 69Y1909| 7656
Brocade 10Gb SFP+ SR Optical Transceiver| 49Y4216| 0069
Brocade 8Gb SFP+ SW Optical Transceiver| 44X1962| 5084
Brocade 14-port Converged 10GbE Switch Port Upgrade| 69Y1917| 2425
Brocade ISL Trunking software upgrade| 26K5607| 4247
Brocade Fabric Watch software upgrade| 45W0504| 4398
Brocade Performance Monitor upgrade| 45W0508| 4248

Part number 69Y1909 include the following items:

  • One Brocade Converged 10GbE Switch Module for BladeCenter (includes two 10GbE SFP+ modules standard)
  • IBM Important Notices document
  • IBM Warranty and Support Guide
  • One mini-USB console cable with serial connectors
  • BC-HT interposer gasket kit (used if the switch module is inserted in  the BladeCenter HT chassis)
  • DB9 to RJ45 adapter
  • The IBM Documentation CD which contains the following documents:
    • Brocade Converged 10GbE Switch Module for BladeCenter Installation and Users Guide
    • IBM Safety Information document (multilingual)
    • IBM Environmental Notices and Users Guide
    • Brocade EULA
    • Brocade CEE Admin guide
    • Brocade CEE CLI guide
    • Brocade MIBS manual

The base model of the Brocade Converged 10GbE Switch Module, 69Y1909, ships with 16 licensed ports. This module supports the Dynamic Ports on Demand (DPOD) feature, where ports are licensed as they come online independent of the port type. In the base model, two external CEE ports (ports 15 and 16) are pre-licensed and are pre-installed with two 10GbE optical transceivers. The remaining 14 licenses are available to be assigned to other internal or external ports. The 16 licensed ports may be any combination of external CEE ports, external FC ports, or internal CEE ports. After all the licenses have been assigned, you can manually move licenses from one port to another.

Additional ports can be activated by purchasing the Brocade Converged 10GbE Switch Port Upgrade, part number 69Y1917. This upgrade option activates the license for the remaining 14 ports. All internal and external ports will then be licensed and can be used. The switch ships standard with two small form- factor pluggable plus (SFP+) modules. Additional SFP+ transceivers can be ordered separately if required. Table 1 lists the transceivers that are supported.

Benefits and features

The Brocade Converged 10GbE Switch Module with a supported converged network adapter (CNA) provides these benefits:

  • Highly integrated BladeCenter switch module
    The Brocade Converged 10GbE Switch Module offers one of the industry’s best integrated I/O solutions. The compact design incorporates Ethernet and Fibre Channel switching and provides a total of 30 ports: eight external 10Gb Ethernet CEE ports for LAN connectivity and eight external 8Gb Fibre Channel ports for storage and SAN connectivity. With the high integration of this module, you can achieve all of your networking and storage I/O needs with a single module.

  • Unique flexible ports and server deployment
    The Dynamic Port on Demand (DPoD) feature of the Brocade Converged 10GbE Switch Module lets you activate any combination of internal or external ports. This means you can to balance server and I/O port assignments to accommodate the workloads of applications and satisfy business needs. DPoD gives you the ability to enable only 10GbE ports for networking needs, only Fibre Channel ports for storage support, or any combination of Ethernet and Fibre Channel ports

  • Support for Data Center Fabric Manager
    IBM System Storage Data Center Fabric Manager (DCFM) is available for use with the switch. DCFM is fully integrated with IBM Systems Director for end-to-end data center management. A 75-day trial version and can be downloaded from:
    http://www.ibm.com/systems/storage/san/b-type/dcfm/

  • Highest bandwidth and low latency
    The total available bandwidth of 144 Gbps (80 Gbps Ethernet and 65 Gbps Fibre Channel) accessible through external ports means the switch module can support high demanding applications and storage solutions. In addition to the high bandwidth available on external ports, the switch module supports an additional 140 Gbps on 14 internal 10GbE ports. The switch module uses cut- through and non blocking to deliver high performance and low latency for demanding virtual applications and high speed environments.

  • Low total cost of ownership
    The highly integrated design delivers the lowest total cost of ownership (TCO). The Brocade Converged 10GbE Switch Module is two switches in one, Ethernet and Fibre Channel, which reduces the cost of acquisition. The switch module is built around a pay-as-you-go model that gives you a lower price entry point and lets you add ports as your business needs dictate. The switch module ships with two 10GbE SFP+ transceivers to further lower initial investments. Because it is designed for seamless integration into existing networking and storage environments, this module truly protects existing investments. Overall, with this integrated switch module, your server infrastructure will use fewer hardware components with lower costs and higher reliability, which further drives a lower TCO.

The converged switch modules have the following features:

  • Eight external 10 Gb Converged Enhanced Ethernet ports
  • Eight external auto-negotiated Fibre Channel ports (2 Gbps, 4 Gbps, or 8 Gbps)
  • 14 internal auto-negotiated 10 GbE ports (1 Gbps or 10 Gbps)
  • Two internal full-duplex 100 Mbps Ethernet interfaces for management purposes
  • One external RS232 console port with a mini-USB interface for serial console management
  • One external 10/100/1000 Mb RJ45 Ethernet copper port for  management
  • CEE features
    • Priority-based Flow Control (PFC): IEEE 802.1Qbb
    • Enhanced Transmission Selection (ETS): IEEE 802.1Qaz
    • Data Center Bridging eXchange (DCBX)
  • Layer 2 features
    • Layer 2 Virtual Local Area Networks (VLANs): 4096
    • VLAN Encapsulation 802.1Q
    • Rapid Spanning Tree Protocol (RSTP)
    • Multiple Spanning Tree MSTP (802.1s): 16 instances
    • Link Aggregation Control Protocol (LACP) IEEE- 802.3ad
    • Brocade enhanced frame-based trunking
    • Advanced PortChannel hashing based on Layer 2, 3, and 4 information
    • Pause Frames (802.3x)
    • Storm Control (unicast, multicast, and broadcast)
    • Address Resolution Protocol (ARP) RFC 826
  • Layer 2 security
    • Ingress Access Control Lists (ACLs)
    • Standard and extended Layer 2 ACLs
    • VLAN-based ACLs (VACLs)
    • Port-based ACLs (PACLs)
    • ACL statistics
    • Port-based Network Access Control: IEEE 802.1X
  • Layer 2 Quality of Service (QoS)
    • Eight priority levels for QoS
    • IEEE 802.1p Class of Service (CoS)
    • Eight hardware queues per port
    • Per-port QoS configuration
    • CoS trust: IEEE 802.1p
    • Per-port Virtual Output Queuing
    • CoS-based egress queuing
    • Egress strict priority queuing
    • Egress port-based scheduling: Weighted Round-Robin (WRR)
  • Layer 3 features
    • Static IP routes
  • External Fibre Channel ports that can operate as F_ports (fabric ports),
  • FL_ports (fabric loop ports), or
  • E_ports (expansion ports)
  • FC fabric services
    • Simple Name Server (SNS)
    • Registered State Change Notification (RSCN)
    • Dynamic Path Selection (DPS)
    • Enhanced Group Management (EGM)
    • ISL Trunking (optional)
    • Fabric Watch (optional)
    • Advanced Performance Monitor (optional)
  • Power-on self-test diagnostics and status reporting

The following software features come with the switch modules:

  • Brocade Web Tools
  • 16-port licensing

The switch supports the following fabric management (all management connections go through the management module except direct serial connection, which goes through the mini USB port):

  • Web interface through Web Tools
  • Command-line interface (CLI) through the Telnet program
  • A terminal emulation program connection to the mini-USB port interface
  • IBM System Storage Data Center Fabric Manager (DCFM) application
  • Switch’s SNMP agent Supported BladeCenter chassis and expansion cards

The Brocade Converged 10GbE Switch Module is supported in the BladeCenter H and HT chassis as listed in Table 2.

Table 2. BladeCenter chassis that support the Brocade Converged 10GbE Switch Module

| | Blade Center S| Blade Center E| Blade Center H| Blade Center T| Blade Center HT| MSIM| MSIM-HT
---|---|---|---|---|---|---|---|---
Brocade Converged 10GbE Switch Module| 69Y1909| N| N| Y| N| Y| N| N

The Brocade Converged 10GbE Switch Module supports the expansion cards listed in Table 3. This table also lists the chassis bays in which the switch module must be installed when used with each expansion card.

Table 3. Brocade Converged 10GbE Switch Module and BladeCenter chassis I/O bays support

| | Bay 1 (Standart)| Bay 2 (Standart)| Bay 3 (Standart)| Bay 4 (Standart)| Bay 5 (Bridge)| Bay 6 (Bridge)| Bay 7 (High-speed)| Bay 8 (High-speed)| Bay 9 (High-speed)| Bay 10 (High-speed)
---|---|---|---|---|---|---|---|---|---|---|---
Gigabit Ethernet integrated in the server| None| N| N| N| N| N| N| N| N| N| N
Ethernet Expansion Card (CFFv)| 39Y9310| N| N| N| N| N| N| N| N| N| N
Ethernet Expansion Card (CIOv)| 44W4475| N| N| N| N| N| N| N| N| N| N
QLogic Ethernet and 4Gb FC Card (CFFh)| 39Y9306| N| N| N| N| N| N| N| N| N| N
2/4 Port Ethernet Expansion Card (CFFh)| 44W4479| N| N| N| N| N| N| N| N| N| N
QLogic Ethernet and 8Gb FC Card (CFFh)| 44X1940| N| N| N| N| N| N| N| N| N| N
NetXen 10Gb Ethernet Expansion Card (CFFh)| 39Y9271| N| N| N| N| N| N| N| N| N| N
Broadcom 2-port 10Gb Ethernet Expansion Card (CFFh)| 44W4466| N| N| N| N| N| N| N| N| N| N
Broadcom 4-port 10Gb Ethernet Expansion Card (CFFh)| 44W4465| N| N| N| N| N| N| N| N| N| N
QLogic 2-port 10Gb Converged Network Adapter (CFFh)| 42C1830| N| N| N| N| N| N| Y| N| Y| N
Emulex Virtual Fabric Adapter (CFFh)| 49Y4245| N| N| N| N| N| N| N| N| N| N
Intel 2-port 10Gb Ethernet Expansion Card (CFFh)| 42C1810| N| N| N| N| N| N| N| N| N| N
Brocade 2-port 10GbE Converged Network Adapter| 81Y1650| N| N| N| N| N| N| Y| N| Y| N

  • One Brocade Converged 10GbE Switch Module occupies two adjacent high-speed bays, and the ports on supported cards are physically routed to the bays 7 and 9.

The BladeCenter chassis have the following bays:

  • BladeCenter S, E, and T have four standard I/O bays (1, 2, 3, and 4)
  • BladeCenter H has four standard I/O bays (1, 2, 3, and 4), two bridge bays (5 and 6), and four high-speed bays (7, 8, 9, and 10)
  • BladeCenter HT has four standard I/O bays (1, 2, 3, and 4) and four high-speed bays (7, 8, 9, and 10)

The Brocade Converged 10GbE Switch Module fits in one of the high speed I/O bay (bays 7-10).

Popular configurations

Figure 2 shows the use of Brocade Converged 10GbE Switch Modules to route two 10 Gb Converged Enhanced Ethernet ports from a Brocade 2-port 10GbE Converged Network Adapter installed into each server. Two Brocade Converged 10GbE Switch Modules are installed in bays 7/8 and bays 9/10 of the BladeCenter H chassis. All connections between the controller, card, and the switch modules are internal to the chassis. No internal cabling is needed.
Product Configurations

Figure 2. A converged 20 Gb solution using redundant Brocade Converged 10GbE Switch Modules

The components used in this configuration are listed in Table 4.

Table 4. Components used when connecting Brocade 2-port 10GbE Converged Network Adapter to two Brocade Converged 10GbE Switch Modules

Diagram reference

| Part number/machine type| Description|

Quantity

---|---|---|---
1| Varies| BladeCenter HS22 or other supported server| 1 to 14 or 1 to

12

2| 81Y1650| Brocade 2-port 10GbE Converged Network Adapter| 1 per server
3| 8852 or 8740/8750| BladeCenter H or BladeCenter HT| 1
4| 69Y1909| Brocade Converged 10GbE Switch Module| 1 to 2
5| 49Y4216| Brocade 10Gb SFP+ SR Optical Transceiver| Up to 6
6| 44X1962| Brocade 8Gb SFP+ SW Optical Transceiver| Up to 6

*The Brocade Converged 10GbE Switch Module has 16 external ports – eight 10 Gb CEE ports and eight 8 Gb Fibre Channel ports. You must have one transceiver for each port in an I/O module (every switch module comes standard with two 10Gb Ethernet SFP+ transceivers).

Refer to the IBM System Storage Interoperability Center web link for information about the compatibility of Brocade Converged 10GbE Switch Modules with storage systems and fabrics: http://www.ibm.com/systems/support/storage/config/ssic

Connectors and LEDs

Figure 3 shows the front panel of the Brocade Converged 10GbE Switch Module.
LED Descriptions
Figure 3. Front panel of the Brocade Converged 10GbE Switch Module

Table 5 explains the components shown in Figure 3.

Table 5. Key to components in Figure 3

Diagram reference|

Description

---|---

1

| Status/Fault LED (amber)
2|

Power LED (green)

3

| Ethernet port (RJ45)
4|

Console port (mini-USB)

5

| Fibre Channel ports (23-30 – right to left)
6|

CEE ports (15-22 – right to left)

7

| CEE port fault status LED (amber)
8|

CEE port link status LED (green)

9

| FC port fault status LED (amber)
10|

FC port Tx/Rx link status LED (green)

11

| Ethernet port speed LED (green)
12|

Ethernet port Link LED (green)

13

|

Release levers (2)

The front panel contains the following components:

  • LEDs that display the following information:
    • The status of the switch module and its network connection
    • The status of the external connections to the switch module
  • Eight FC SFP+ port connectors to attach SFP+ modules. They are numbered 23-30 right to left.
  • Eight FCoE/CEE SFP+ port connectors to attach SFP+ modules.  They are numbered 15-22 right to left.
  • One RJ-45 Ethernet port connector for debug and field support.
  • One mini-USB console port connector used for switch management. This port requires a mini-USB plug on the serial cable.

Network cabling requirements

The following network cables are supported for the Brocade Converged 10GbE Switch Module:

  • 10GBASE-SR for 10Gb CEE ports
    • 850 Nm wavelength, multimode fiber, 50 µ or 62.5 µ (300 meters maximum), with LC duplex connector
  • 8 Gb FC ports when operating at 8 Gbps speed
    • 850 Nm wavelength, multimode fiber, 50 µ (150 meters maximum) or  62.5 µ (21 meters maximum), with LC duplex connector
  • 1000BASE-T for RJ-45 port
    • UTP Category 6 (100 meters maximum)
    • UTP Category 5e (100 meters maximum)
    • UTP Category 5 (100 meters maximum)
    • EIA/TIA-568B 100-ohm STP (100 meters maximum)

Operating environment

The switch module has the following physical specifications:

  • Dimensions:
    • Approximate height: 4.10 cm (1.61 inches)
    • Approximate width: 29.38 cm (11.57 inches)
    • Approximate depth: 25.70 cm (10.12 inches)
    • Approximate weight: 2.13 kg (4.7 lb)
  • Operating:
    • 0° to 40° C (32° to 104° F) at 0 to 3,048 m (0 to 10,000 ft) operating
  • Non-operating:
    • -20° to 70° C (-4°F to 158° F) at 0 to 10,688 km (0 to 35,000 ft) non operating
  • Humidity:
    • 10% to 90% (non-condensing) at 29° C operating
    • 5% to 95% (non-condensing) at 38° C non-operating

Related publications
For more information refer to these documents:

Related product families
Product families related to this document are the following:

  • 10 Gb Embedded Connectivity
  • Blade Networking Modules

Notices

Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:

Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing

LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.

Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

© Copyright Lenovo 2022. All rights reserved.

This document, TIPS0789, was created or updated on August 7, 2011.

Send us your comments in one of the following ways:

This document is available online at https://lenovopress.lenovo.com/TIPS0789.

Trademarks

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
BladeCenter Interoperability Guide
BladeCenter®

The following terms are trademarks of other companies:

Intel® is a trademark of Intel Corporation or its subsidiaries.

Other company, product, or service names may be trademarks or service marks of others.

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lenovo User Manuals

Related Manuals