Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved! Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly. Updating the documentation If you have suggestions for improvement or have found any irregularities, please contact us.
The information contained in this document may alter at any time without previous notice. It is prohibited to copy or spread any parts of this document in any way without prior written allowance. All rights reserved. The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this operating manual, nor in the diagrams and figures shown. Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided. If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing from you.
Send an e-mail to: service@wiltec.info
or use our contact form: https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via: https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12 52249 Eschweiler
Germany
To return orders for exchange, repair, or other purposes, please use the following address. Attention! To allow for a smooth execution of your complaint or return, it is important to contact our customer service team before returning the goods.
Returns Department WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592­0
Fax: +49 2403 55592­15

Introduction

Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Keep these operation instructions safe.

Security notes

ATTENTION: In stagnant waters, garden ponds, swimming ponds, and the surrounding areas, the device can only be used with a residual current circuit breaker and a triggering nominal current up to 30 mA (according to VDE 0100 part 702 and 738).
The device is not suitable for use in swimming pools, any kind of paddle ponds and the like that are used by humans during the operation of the device. Operating the device during the stay of humans in the danger zone is not permitted. Ask your electrician!
The device must not be used by persons (including children) with reduced physical, sensory, or mental capabilities and/or lack of experience or knowledge, unless they are instructed by a person responsible for their safety or given instruction how to use the device. Children should be supervised so that one can be sure that they do not play with the device.
ATTENTION:

  • Perform a visual inspection before each use of the device. Do not use the device if the safety equipment is damaged or worn. Never override the safety equipment.
  • Only use the device for the purpose as specified in this manual.
  • You are responsible for the safety in the work area.
  • If the power cord or the plug is damaged by external influences, the cord must not be repaired! It must be replaced with a new one. This operation must be carried out only by a qualified electrician.
  • The voltage of 230 V AC as indicated on the nameplate must meet the mains voltage.
  • Never lift, transport, or fix the device by using the power cord as a means for this purpose
  • Make sure that the electrical connectors are protected from flood and moisture.
  • Pull the power plug before working on the device.
  • The device must not be exposed to a direct stream of water or rain.
  • The user is responsible for the compliance with local safety and installation regulations (ask an electrician in case of doubts).
  • Consequential damage due to flooding caused by faults of the device is to be prevented by the user who takes the appropriate measures therefore (e.g., installation of an alarm system, reserve pump).
  • In case of a failure, the device may only be repaired by a qualified electrician.
  • The device must never run dry or be operated with the suction tube fully closed.
  • The device must not be used for the operation inside swimming pools.
  • The device must not be installed in the portable water cycle.

WARNING:

  • Read all safety warnings and instructions. Any failure due to disrespect of the safety instructions may result in electric shock, fire, and/or serious injury.
  • Keep all warnings and instructions for the future.

Resistance

  • During continuous operation, the maximum temperature of the liquid to deliver should not exceed +35 .
  • The delivery of aggressive liquids (such as acids, alkalis, silo seepage, etc.) as well as liquids containing abrasive materials (sand etc.) is to be avoided.

Electrical connection

  • The electrical connection is made to a grounded socket 230 V ~ 50 Hz. Hedging at least 6 A.
  • The engine is protected from overload and blockage by an integrated thermal motor protection.

Mains connection

The acquired pond pump is already equipped with a grounded socket. The pump is intended for a connection to a grounded socket with 230 V ~ 50 Hz. Make sure that the socket is adequately secured and in a good condition. Run the pump plug into the socket. The pump is ready for operation.
Unpacking
Unpack the delivered parts and check them for completeness and intactness. If you discover a defect, contact your specialist dealer immediately. Keep the packaging and the operating instructions so that you can safely store and pass on the product in the future. Dispose of packaging material that is no longer required in an environmentally friendly manner.
Conventional use

  • The device can displace pond water with a temperature of +4 to +35 (the particulates size must be less than 5 mm).
  • You can use the pump for the following purposes: to operate a filter for garden ponds; to operate a water course; to serve as an aquarium filter to operate a fountain; to serve as circulation pump for swimming pools; to operate an aquaculture.

Safety instructions

  • For your own safety, please contact an electrical specialist in case of questions and problems.
  • Before reaching in the water, always unplug all power cords of devices in the water.
  • Plug in the pump only to a power receptacle with ground contact. This type of outlet must have been set up according to the respective national directives. Ensure that the PE conductor goes all the way to the pump.
  • Never use installations, adapters, extension cords, or connecting cords without ground contact.
  • Ensure that the pump is supplied via a residual current device (FI or ECD) with a measured residual current of not more than 30 mA.
  • Electrical installations on garden ponds must correspond to the national and international installation directives.
  • Only operate the pump if no one is in the water.
  • Do not carry or pull the pump by the connecting cord.
  • Keep the power plug and all connecting parts dry.
  • The pump may not be operated if the cable or the housing are defective.
  • If the power cord of the pump is damaged, it must be replaced by the manufacturer or by a similarly qualified person to avoid hazard.
  • Never displace any liquids other than water.
  • Caution: The pump will stop automatic if working without water or overloading; it will work again after having been re-plugged in.

Installation

  1. Compare the voltage and frequency of your electrical circuit with the data on the item. The data must meet each other.
  2. Make the necessary hose connections (if required) or install a fountain attachment. After the installation, ensure that there are no air bubbles in the hose system (lay hose lines on an incline).
  3. Install the pump horizontally on a fixed support at least 20 cm under the water surface. Comply with maximum permitted immersion depth (see the information on the model plate).
  4. Lay the power cord in a protected manner to exclude the possibility of damage.
  5. Connect the pump to the electrical circuit.

CAUTION: This pump does not have filter basket, so the particulate size in the water must be less than 5 mm. Otherwise the impeller may block.

Explosion view and parts list

Name
1 Inlet and outlet
2 O-ring 1
3 Screw
4 Pump housing
5 Rotor sub-assembly
6 O-ring 2
7 Bearing
8 Bearing seal
9 Press nut
10 Motor body
11 Rubber feet

Technical specifications

Item number| Model| Energy supply| Power (W)| Delivery head (m)| Flow rate (K)| Connexions (mm)
---|---|---|---|---|---|---
50964| CPP-5000| 220-240 V
5o Hz| 3o| 3.| 5000| 19/25/33
(3/4″/1″/11/4″)
50965| CPP-6000| 40| 4.| 6000
50966| CPP-7000| 50| 5.| 7000
50967| CPP-8000| 7o| 6.| 8000
50972| CPP-10000| 8o| 6.o| 10000| 25/33/38/51
(3/a”-2″)
50973| CPP-12000| 100| 7.| 12000
50974
50975| CPP-14000| 120| 7.0| 14000
CPP-16000| 140| 8.| i6000

Cleaning instructions

  1. Use the screwdriver to unscrew the pump housing (pic. 1).
  2. Turn the motor body in the direction as indicated by the arrow, then take it out (pic. 2).
  3. Clean and change the impeller after taking out (pic. 3).
  4. Make sure to put the O-ring at the right place as show in the pic. 4.

Maintenance/cleaning the pump

  1. Please clean the pump every four weeks or when the performance decreases.
  2. Take the pump apart, and open the impeller housing via the screw.
  3. Brush the pump, impeller, and rotor with a banister brush.

Winter care

  1. Take the pump out of the water.
  2. Thoroughly clean the pump.
  3. Check the pump for damage.
  4. Store the pump frost-free, and, if possible, in a container with water.

Disposal regulations

EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were implemented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEEregistration number DE45283704.
Disposal of used electrical and electronic appliances (intended for use in the countries of the European Union and other European countries with a separate collection system for these appliances). The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities, or the store where you purchased the article.
Address: WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction manual require the written permission of WilTec Wildanger Technik GmbH.

© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
Item 50964­50967, 50972­50975

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals