SUNSUN CET-8000 Adjustable SuperECO Pond Pump User Manual
- June 5, 2024
- SUNSUN
Table of Contents
SUNSUN CET-8000 Adjustable Super ECO Pond Pump
Read and follow the operating instructions and safety information before using
for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical
data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities,
please contact us.
The information contained in this document may alter at any time without
previous notice. It is prohibited to copy or spread any parts of this document
in any way without prior written allowance. All rights re-served.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible
mistakes in this operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible
efforts to ensure that the operating manual is complete, faultless, and up to
date, mistakes cannot be entirely avoided. If you should find a mistake or
wish to make a suggestion for improvement, we look forward to hearing from
you.
Send an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in
our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
Do you wish to pick goods up? Our pick-up address is:
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany
To shorten the waiting time and allow for a rapid on-site transaction, we ask
you to call us previously or placing your order via the web shop.
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
To return orders for exchange, repair, or other purposes, please use the
following address. Attention! To allow for a smooth execution of your
complaint or return, it is important to contact our customer service team
before returning the goods.
Returns Department
WilTec Wild anger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
Introduction
Thank you for purchasing this quality product. To minimize the risk of injury
we urge that our clients take some basic safety precautions when using this
device. Please read the operation instructions carefully and make sure you
have understood its content.
Keep these operation instructions safe.
Unpacking
If the article is visibly damaged, please contact the vendor.
Safety regulations
- For your own safety, please contact an electrical specialist in case of questions and problems.
- Do not connect the power supply until all parts are installed.
- Only plug the pump in a power receptacle with ground contact. This type of outlet must have been set up according to the respective national directives. Ensure that the PE conductor goes all the way to the pump.
- Make sure that the voltage in the pump is the same as the actual power supply.
- Electrical installations on garden ponds must correspond to the national and international instal-lation directives.
- Only operate the pump if there is no one in the water.
- Do not carry or pull the pump by the connecting cord. The cable must not get in contact with heat or grease; it must not touch sharp angles.
- The pump may not be operated if the cable or the casing are defective.
- Never transport any liquids other than water.
- Attention : The pump will automatically stop working if overloaded or running without wa-ter.
- The controller is not water-proof; put it in a dry and well-ventilated place.
- Do not inspect the electrical parts of the pressure pond filter in a wet or damp environment or when you are wet yourself, and protect it from direct sunlight.
- Install this device in a safe location so that nobody can step on, fall over, or damage the cable.
- Disconnect the power plug before cleaning, and use only a damp cloth for cleaning. Avoid using cleaning agents and make sure that no liquid enters the electric parts of the pump.
- The electric parts of the device contain no parts that can be inspected or serviced by the user. Leave the maintenance, adjustment, and repair to qualified technical personnel. In case of un-authorised intervention, the 2-year warranty is no longer valid!
Use
Applies to ponds, rockery, aquarium tanks, and seafood tanks.
Features
-
Multi-function intelligent control, can adjust flow and power
-
New electronic frequency conversion technology, energy saving 60 %
-
Centrifugal impeller design, improves H-max and output
-
Super silence, usable both in fresh and sea water
-
New and generous design, rotary handle, easy to carry
-
Rotary footings, can work both vertical or horizontal
-
Ceramic shaft, wear and rust resistance
-
Long service life, no copper element
-
Multistage outlet, suitable for a variety of pipe diameter connection
-
Electric drive, safe and stable
-
External aluminium alloy radiator of the controller can dispatch well heat well
-
With anti-blocking and anti-idling function (cuts off power immediately and automatically if impeller is blocked, immediately and automatically cuts off power if pump is idling)
-
With alarm function, warns you of various abnormal problems
Installation
-
Notify your dealer immediately if there are external damages.
-
Compare the voltage and frequency of your electrical circuit with the data on the model plate, these data must correspond.
-
Connect the pipeline if needed. (Attention: The piping system must not contain bubbles.) Hose connection diagram is as follows:
This product disposes of a variety of outlets, you can select one according to the size. Loosen the nut in clockwise direction, connect the hose, tighten the nut in anti-clockwise direction. -
Attention : the pump must be installed below the water level 20 cm at least; the water surface must be stale and horizontal.
-
Do not place the pump directly in muddy pond floors, place it on a raised surface.
-
Connect the pump with the controller of four core wire , lock the nut۔
Controller unit
The controller consists of hook, panel, touch buttons and fixed foot.
- Switch function
After the power is switched on, touch “START-STOP,” control the pump switch.
Attention : please cut off the power if you do no use the pump for a long time.
- Adjust the gear level
Touch “DOWN” or “UP” to adjust pump gear. Consult the detailed performance data below:
50982 (CET-8000)
Power supply
| Gear level| Power (W)| Flow rate (ℓ⁄h)|
Max. lifting head (m)
---|---|---|---|---
220–240 V, 50 Hz
|
SP01
| 18| 3500| 1.6
SP02| 23| 4000|
1.9
SP03
| 28| 4600| 2.3
SP04| 35| 5000|
2.7
SP05
| 42| 5400| 0.1
SP06| 51| 5800|
3.5
SP07
| 60| 6200| 3.9
SP08| 66| 6700|
4.5
|
SP09
| 73| 7200| 4.8
---|---|---|---|---
SP10| 80| 8000|
5.4
51192 (CET-15000)
Power supply| Gear level| Power (W)| Flow rate (ℓ⁄h)|
Max. lifting head (m)
---|---|---|---|---
220–240 V, 50 Hz
|
SP01
| 37| 7500| 2,3
SP02| 47| 8500|
2,7
SP03
| 61| 9200| 3,2
SP04| 77| 10.000|
3,7
SP05
| 97| 11.000| 4,3
SP06| 110| 11.500|
4,9
SP07
| 124| 12.000| 5,4
SP08| 142| 12.700|
6,0
SP09
| 157| 13.500| 6,5
SP10| 180| 15.000|
7,0
-
Feeding function
Long press “UP” until the buzzer sounds twice; delay start is activated. You have 10 min to feed the fish. Operation is the same if you want to cancel this delay start. -
Lock/unlock function
With the correct gear, you need to press “down” until the buzzer sounds twice. The pump is now locked. To unlock proceed in the same way. -
Automatic memory function
When the controller power is cut off suddenly, it keeps its memory. The pump will automatically recover its operation state as before when the power is switched on another time. -
Alarm function
The pump will cut off power immediately and automatically if the pump idles. It will re-start au-tomatically to work again after 5 s. If still idling, the pump will automatically cut the power off again. After five times of repeated activation, the pump will power off until re-connect the power. Meanwhile, the alarm buzzer will sound. -
The pump will cut off power automatically and immediately if the impeller is blocked, and the alarm buzzer will sound until the pump is re-connected to the power supply.
-
Code definition and troubleshooting
Code|
Definition
|
Status
|
Solution
---|---|---|---
P000
| Power| Normal| ―
SP00
|
Gear
|
Normal
FEE0| Delayed start|
Normal
ER05
| Short-circuit current display| Abnormal| Check controller unit.
ER04| overheat flicker| Abnormal|
Clean pump.
ER03
| Pump works without water| Abnormal|
Check the pump if working without water.
ER02
| Pump block| Abnormal| Check the impeller if blocked.
ER01| Over-/under voltage display| Abnormal|
Check voltage.
Maintenance/cleaning
Please clean the filter casing, impeller, rotor, and shaft part regularly. Please cut off the power before you clean it.
- Turn and take off the filter casing
- Press the security clasp vertically , and take off the impeller cover
- Take off the rotor set , then you can clean or change.
- Installation position of the O-ring
- If the pump is not used for a long time, please run the pump in clean water for a short time. Then rinse it with clean water. After that, dry it and keep it in a secure place.
- If the temperature is below 0 ℃, the water in the pump should be discharged immediately to prevent a freezing damage.
Troubleshooting
Problem
| Cause|
Solution
---|---|---
Pump does not run| No power supply| Connect the power
Burning machine| Change pump
Impeller stall| Clean and re-link to power
Runs without water| Fill with water and re-link to power
Not connected with the controller unit| Re-link to the controller unit
The controller is damaged| Change the controller
Pump noise| Dirt inside| Clean pump
Shaft break or wear| Change shaft
Pump water short- age| Damage of the impeller| Change impeller
Inlet or outlet obstruction| Clean inlet and outlet
Filter case obstruction| Clean filter case
Low voltage| Adjust voltage
Exploded view
№ | Name | № | Name |
---|---|---|---|
1 | Bottom foot | 8 | Ceramic bearing |
2 | Filter case | 9 | Motor with cable |
3 | Outlet | 10 | Rear cover |
4 | Seal circle | 11 | Handle |
5 | Impeller cover | 12 | Rubber foot |
6 | Rotor set | 13 | Gear box with cable |
7 | O-Ring |
Disposal regulations
- EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were implemented in the law related to electrical and electronic equipment and appliances.
- All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.
- The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEE-registration number DE45283704.
- Disposal of used electrical and electronic appliances (intended for use in the countries of the European Un-ion and other European countries with a separate col-lection system for these appliances).
- The logo on the article or on its packaging points out that this article must not be treated as normal house-hold waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal.
- Material recycling helps reduce the consumption of raw materials.
- Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities, or the store where you purchased the article.
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in
part, of this instruction manual require the written permission of WilTec
Wildanger Technik GmbH.
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
References
- Aoyue.de
- Teichtip.de
- WilTec - Ihr Online Shop für Haus, Garten, Werkstatt, Freizeit
- Unternehmen: WilTec Wildanger Technik GmbH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>