maintronic CBA UP Casambi blind actuator User Manual
- June 7, 2024
- maintronic
Table of Contents
maintronic CBA UP Casambi blind actuator
General information
About this Document
Congratulations and thank you for choosing this maintronic product and the
trust you have placed in us. We, the team of maintronic, wish you a lot of fun
with this product.
Due to continuous product development, some of the information may not be
complete and up-to-date.
The information in this document is subject to change without prior notice.
Please check our website www.maintronic.de, if
there is a newer version.
Service and contact
You can find information, onlinehelp as well as downloads for the product on
our website. Con-tact us if you have any problems or questions about your
device.
Legals
The division building automation and all associated products are products of
MTC maintronic® GmbH (hereafter maintronic). All rights reserved, as well as
mistakes and typing errors.
The trademarks and trade names mentioned in this document are the property of
their respective owners.
The content in this document is for product information purposes only. Product
features may vary during continuous product development and may change at any
time without notice.
maintronic assumes no liability or warranty regarding this document or the
products described.
Safety information
For your own safety, read all instructions and in-formation in this manual
carefully before initial operation. Keep this manual for future reference.
The instructions are an integral part of the pro-duct and must be handed to
the end customer.
All information and instructions in this manual must be observed completely
and in detail. The manufacture is not responsible for any direct or
consequential damage that results from disregar-ding any information in this
manual.
Waste disposal
In accordance with European Directive 2002/96/EC (it`s) not longer usable
electronic devices and defective or used batteries (European Directive
2006/66EG) must collected separately and disposed by an environmentally sound
recycling.
This symbol indicates that electrical and electronic equipment must be
disposed of separately from normal waste at the end of its operational
lifetime.
Should these product are no longer be useable, the user is required by law to
dispose of old appliances separately from their household waste e. g. at a
local authority collection point or recycling center.
The unit must only be installed and serviced by a proven electrician
specialist, in accordance of all relevant regulations, safety and accident
prevention directives of the country.
Be sure that the existing mains voltage corresponds with the specified
operating voltage before operating the device.
Risk of electric shock. Do not operate the device without a cover. Even when
switched off, voltage may be present at the outputs. When working on the
device or connected loads, always disconnect the upstream fuse from the power
supply.
Apply the „Five Safety Rules“
(DIN VDE 0105, EN 50110):
- Disconnect
- Secure against being switched on again
- Determine absence of voltage
- Ground and short circuit
- Cover or isolate nearby live parts
Only install the device in places with a good ventilation and without humidity
or high tempe-ratures. Do not expose the unit to rain or snow. Do not operate
the unit near heat sources, e.g. radiators.
If any of the following occurs, do not operate the device without first
checking it:
- if objects have fallen or liquid has been spilled into the unit.
- if the device has been exposed to rain.
- if the device does not operate normally or with altered characteristics.
- if the device has been dropped or has a bro-ken housing.
For cleaning only use a dry, soft cloth, by no me-ans liquids.
Product description
Intended Use
Casambi blind actuator for control of blind, shutter, gate, or awning
motors. Control by Casambi Bluetooth via APP or local control using standard
blind pushbuttons
Functions
The blind actuator CBA UP Casambi has a Bluetooth Casambi interface and can be
opera-ted via smartphone with the Casambi APP.
Casambi App automatically identifies the device and can be integrated into
existing networks.
The device has different operating modes (so-called Casambi profiles) with the
profiles the functionality and the parameters are determined. Casambi profile
must be selected in the Casambi APP when pairing a device in order to select a
specific operating mode.
As soon as the device is added to your network, it can be operated. Groups can
be formed, scenes and timers can be created.
These functions allow e.g. to group 5 blinds on one side of a building and to
operate them together. In addition, automated up and down movements can be
programmed as a time-controlled scene.
If you need help with configuration and operation of Casambi please refer to
the official Casambi help at: https://support.casambi.com
Operating notes
There are different methods to operate the blind actuator.
Driving over driving time
In the case of driving over the driving time, a sin-gle impulse (e.g. pressing
a button or starting a time-controlled scene) triggers the blind/shutter etc.
to move once to the zero point(OT) 0% or end point(UT) 100%.
This driving time is stored in the parameters of the actuator once and then
recalled (see 4.4).
Driving to an absolute position
With a drive to an absolute position, any hori-zontal position can be
approached. The absolute position is controlled by a slider (from OT 0% to UT
100%), which determines the position of the connected blind / shutter, etc..
Slat adjustment
A slider can be used to adjust the angle of the slats for venetian blinds.
Furthermore, the slat position is stored when moving to an absolute position
and the set value is automatically readjusted after re-aching the driving
position.
For example, if the blind shall be moved down only a little bit and the slats
are set to 5%. Then after reaching the target position, the slats are set to
5% again.
Installation and dimensions
Even though the device has very compact dimensions, it is strongly recommended
to use the deepest junction boxes possible.
Depending on which pushbutton attachments are used, up to 30 mm of additional
installation space is required.
For installation in cavity or switch boxes, the side flaps have to be removed. Install the device with the labeling, LED and device buttons facing for- wards.
Connections and elements
- N Neutral conductor
- N Neutral conductor
- L Input Voltage 230V AC
- Relay up
- Relay down
- L‘ Release phase for standard blind button
- T1 Pushbutton input 1
- T2 Pushbutton input 2
Note: The relay outputs are mutually locked to ensure that only one drive path is active at a time (motor protection).
Commissioning
To make sure that the functionality of the device is up to date, first of all you have to check if a new firmware is available.
Update firmware
- Go to nearby devices
- Scroll down
- Check for updates
- If an update is available, please install
Choose application profiles
The device has different operating modes (so-called Casambi profiles) with the
profiles the functionality and the parameters are determined. Before
programming, a Casambi profile must be selected (by default, the profile – CBA
Blind + But-tons is set).
Select a suitable profile for your application on the following pages.
Profiles for venitian blinds
CBA Blind| • Operation via APP
• Move blind to absolute position
• Adjust slat angle
---|---
CBA Blind
+ Buttons
| • Move blind to absolute position
• Adjust slat angle
• Additional controls for activation via external pushbuttons or scenes
Profiles for roller blind
CBA Shutter| • Operation via APP
• Move roller blind to absolute position
---|---
CBA Shutter
+ Buttons
| • Move roller blind to absolute position
• Additional controls for activation via external pushbuttons or scenes
Select profile and learn into a network
If you have selected a suitable profile for your ap-plication from the following pages, the device will be added to a Casambi network.
Profile A: CBA Blind
Drive blind | Adjust slats
Casambi profile name| Fixture Id| Control element name|
Function| Control element type
---|---|---|---|---
CBA Blind| 17801| Position| Position| Slider (0% – 100%)
| | Angle| Slat angle| Slider (0% – 100%)
Profile parameter
Parameter Casambi| Description parameter| Value| Default |
Notes
---|---|---|---
Drive Time| Drive time for blind operation| 0 … 255s (seconds)| 60s default
Angle Time| Drive time for slat adjustment| 0 … 65535ms (milliseconds)| 2000ms
default
Swap Controls Up/
Down
| Logical invert of drive direction| No | Yes| Reverse driving direction
Push Button mode| Behavior of the pushbutton inputs| Description see 5.3|
Profile B: CBA Blind + Buttons
Drive blind | Adjust slats | additional switches
Casambi profile name| Fixture Id| Control element name|
Function| Control element type
---|---|---|---|---
CBA Blind + Buttons| 17802| Position| Position| Slider (0% – 100%)
| | Angle| Slat angle| Slider (0% – 100%)
| | Up| Single drive Up| ON/OFF Toggle
| | Down| Single drive Down| ON/OFF Toggle
| | Angle| Slat angle| Push Button
Profile parameter
Parameter Casambi| Description parameter| Value| Default |
Notes
---|---|---|---
Drive Time| Drive time for blind operation| 0 … 255s (seconds)| 60s default
Angle Time| Drive time for slat adjustment| 0 … 65535ms (milliseconds)| 2000ms
default
Swap Controls Up/
Down
| Logical invert of drive direction| No | Yes| Reverse driving direction
Push Button mode| Behavior of the pushbutton inputs| Description see 5.3|
Profile C: CBA Shutter
Roller blind drive
Casambi profile name| Fixture Id| Control element name|
Function| Control element type
---|---|---|---|---
CBA Shutter| 17803| Position| Position| Slider (0% – 100%)
Profile Parameter
Parameter Casambi| Description parameter| Value| Default |
Notes
---|---|---|---
Drive Time| Drive time for roller blind| 0 … 255s (soconds)| 60s Default
Swap Controls Up/
Down
| Logical invert of drive direction| No | Yes| Reverse driving direction
Push Button mode| Behavior of the pushbutton inputs| Description see 5.3|
Profile D: CBA Shutter + Buttons
Roller blind drive | Operation additional switches
Casambi profile name| Fixture Id| Control element name|
Function| Control element type
---|---|---|---|---
CBA Shutter + Buttons| 17804| Position| Position| Slider (0% – 100%)
| | Up| Single drive Up| ON/OFF Toggle
| | Down| Single drive Down| ON/OFF Toggle
Profile parameter
Parameter Casambi| Description parameter| Value| Default |
Notes
---|---|---|---
Drive Time| Drive time for roller blind operation| 0 … 255s (seconds)| 60s
default
Swap Controls Up/
Down
| Logical invert of drive direction| No | Yes| Reverse driving direction
Push Button mode| Behavior of the pushbutton inputs| Description see 5.3|
Profile E: CBA Buttons
Roller blind drive | with buttom operation elements in App
Casambi profile name| Fixture Id| Control element name|
Function| Control element type
---|---|---|---|---
CBA Buttons| 14343| Up| Single drive Up| ON/OFF Toggle
| | Down| Single drive Down| ON/OFF Toggle
| | Function A| Function for button A| Push Button
| | Function B| Function for button B| Push Button
Profile parameter
Parameter Casambi| Description parameter| Value| Default |
Notes
---|---|---|---
Drive Time| Drive time for roller blind operation| 0 … 255s (seconds)| 60s
default
Function A
Function B
| Function for button A
Function for button B
| Not in Use| Not in Use
Blind Up| Roller blind ▲ Up
| | Blind Down| Roller blind ▼ Down
| | Toggle direction| ▲ .. Stop .. ▼ .. Stop
Change direction
| | Blind Up with Time| Rollo ▲ up with time
| | Blind Down with Time| Rollo ▼ down with time
| | Toggle direction with Time| ▲ (t) Stop .. ▼ (t) Stop
Reverse direction by time
Swap Controls Up/
Down
| Logical invert of drive direction| No | Yes| Reverse driving direction
Push Button mode| Behavior of the pushbutton inputs| Description see 5.3|
Calibration
Once the device is added into a Casambi network, a calibration can be performed..
Perform calibration drive (Drive time)
To ensure proper operation, a calibration drive must be performed during
initial startup.
- Therefore, run a complete cycle (0% fully open to 100% fully closed) and measure the drive time.
- In order to take into effect deviations in the travel time from bottom to top, the cycle (from 100% completely closed to 0% completely open) can be measured again.
- Enter the measured time plus approx. 1 se-cond (as a buffer) in the device settings under parameter „Drive Time“.
Setting the slat position (Angle time)
The „Angle Time“ is the aperture angle of the blind slats, this time must be
measured and set in the parameters
- Move the blind up a little until the slats are in a horizontal position.
- Now move the blind downwards and stop the time until the slats are closed.
- Set the measured time in ms in the parameters under „Angle Time“.
Set drive direction
If the drive direction is not correct, the parameter „Swap Controls Up/Down“
can be used to swap the direction.
Operation
Operation with device button
The device button 1 has the same priority as the Casambi APP, the last one wins.
Operation with pushbutton input T1 / T2 (only 10.752)
Enabled with 2 programmable inputs, local con-trol is so much easier. These inputs can used as a direct preconfigured Up-Down pushbutton or control any casambi enabled device over Casambi input control. It‘s just a change of an parameter in the app.
Push Button mode
In order to change the Push Button mode, proceed as shown on the right. The functionality of the push button inputs is defi-ned by a parameter. Before the button inputs are configured, a push button mode must be selected.
- Open Casambi app
- Double tap on the device
- Scroll to the item parameter
- Tap on Push Button mode
- Select parameters (See the list below)
Configure pushbutton inputs
Pushbutton inputs can be individually assigned with desired functions. In order to do this, the following steps are necessary:
- Open Casambi app and tap on „… More“
- Open item „Switch“
- Select device
- For example program switch with single function
a) Select not active
b) Select not active
c) Select controls an element
d) Select element
e) Select CBA Buttons UP
Operation with pushbutton over L‘ release phase
Pin 6 (L’) is an release phase to where an external blind pushbutton can be connected.
WARNING: Please note that the pin for enabling phase L‘ (pin 6) is always connected to the mains voltage as long as no active movement is being performed via the Casambi control level.
All movements via the „L‘ path“ control are not detected by Casambi. If you
use profiles A,B,C or D, the indication of the horizontal position is no
longer correct. Only a travel to one of the end points (OT/UT) via the control
from Casambi „synchronizes“ the display with the real position again.
As soon as a travel command or an automation object is sent, the manual travel
is interrupted. If the device is operated in automated mode, the key inputs T1
and T2 (only 10.752) must be used.
www.maintronic.de
info@maintronic.de
References
- Forsiden | Item
- MTC maintronic GmbH - Business Solutions - Gebäudeautomation - Pro Audio - MTC maintronic GmbH
- Support : Casambi Support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>