WARNING
To reduce the risk of injury, the user must read and understand the operator’s
manual.
GENERAL POWER TOOL SAFETY WARNINGS
WARNING
Read all safety warnings, instructions, illustrations and specifications
provided with this power tool. Failure to follow all instructions listed below
may result in electric shock,
fire and/or serious injury. Save all warnings and in- instructions for future
reference. The term “power tool” in the warnings refers to your mains-operated
(corded) power tool or battery-operated (cordless) power tool.
WORK AREA SAFETY
- Keep work area clean and well lit. Cluttered or dark areas invite accidents.
- Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks that may ignite dust or fumes.
- Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control.
ELECTRICAL SAFETY
-
Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock.
-
Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
-
Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
-
Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts.
Damaged or entangled cords increase the risk of electric shock. -
When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
-
If operating a power tool in a damp location is unavoidable, use a ground fault circuit interrupter (GFCI) protected supply. The use of a GFCI reduces the risk of electric shock.
PERSONAL SAFETY
- Stay alert, watch what you are doing, and use common sense when operating a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury.
- Use personal protective equipment. Always wear eye protection. Protective equipment such as a dust mask, non-skid safety shoes, hard hat or hearing protection used for appropriate conditions will reduce personal injuries.
- Prevent unintentional starting. Ensure the switch is in the off-position before connecting to a power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents.
- Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
- Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations.
- Dress properly. Do not wear loose clothing or jewelry. Keep your hair and clothing away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
- If devices are provided for the connection of dust extraction and collection facilities, ensure these are connected and properly used. Use of dust collection can reduce dust-related hazards.
- Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles. A careless action can cause severe injury within a fraction of a second.
POWER TOOL USE AND CARE
- Do not force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed.
- Do not use the power tool if the switch does not turn it on and off. Any power tool that cannot be controlled with the switch is dangerous and must be repaired.
- Disconnect the plug from the power source and/ or remove the battery pack, if detachable, from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
- Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users.
- Maintain power tools and accessories. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools.
- Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
- Use the power tool, accessories and tool bits etc. in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.
- Keep handles and grasping surfaces dry, clean and free from oil and grease. Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations.
BATTERY TOOL USE AND CARE
- Recharge only with the charger specified by the manufacturer. A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack.
- Use power tools only with specifically designated battery packs. Use of any other battery packs may create a risk of injury and fire.
- When the battery pack is not in use, keep it away from other metal objects, like paper clips, coins, keys, nails, screws or other small metal objects, that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fire.
- Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
- Do not use a battery pack or tool that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury not expose a battery pack or tool to fire or excessive temperature. Exposure to fire or temperature above 130°C (265°F) may cause an explosion.
- Follow all charging instructions and do not charge the battery pack or tool outside the temperature range specified in the instructions. Charging improperly or at temperatures outside the specified range may damage the battery and increase the risk of fire.
SERVICE
- Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
- Never service damaged battery packs. Service of battery packs should only be performed by the manufacturer or authorized service providers.
NAILER SAFETY WARNINGS
-
Always assume that the tool contains fasteners. Careless handling of the nailer can result in the unexpected firing of fasteners and personal injury.
-
Do not point the tool owards yourself or anyone nearby. Unexpected triggering will discharge the fastener causing an injury.
-
Do not actuate the tool unless the tool is placed firmly against the workpiece. If the tool is not in contact with the workpiece, the fastener may be deflected away from your target.
-
Disconnect the tool from the power source when the fastener jams in the tool. While removing a jammed fastener, the nailer may be accidentally activated if it is plugged in.
-
Use caution while removing a jammed fastener. The mechanism may be under compression and the fastener may be forcefully discharged while attempting to free a jammed condition.
-
Do not use this nailer for fastening electrical cables. It is not designed for electric cable installation and may damage the insulation of electric cables thereby causing electric shock or fire hazards.
-
Prior to each use, check workpiece contact and trigger for correct operation. Do not disassemble or clamp parts of the workpiece contact, trigger, or driving
mechanism. This will cause unexpected actuation, resulting in serious injury. -
Do not engage in horseplay. The discharged fasteners are projectiles capable of causing serious injury.
-
Do not remove, tamper with, or otherwise cause the tool operating controls to become inoperable. This will cause unexpected actuation, resulting in serious injury.
-
Do not operate a tool if any portion of the tool operating controls is inoperable, disconnected, altered, or not working properly. This will cause unexpected actuation, esulting in serious injury.
-
Always keep hands and body away from the discharge area of the tool. Never attempt to clear a jammed workpiece contact by grasping the discharge area of the tool. Fasteners discharged from tools can cause serious injury if they contact hands or the body.
-
Do not drive fasteners close to the edge of the workpiece. Fasteners can slip off corners and edges or penetrate through thin material, making them projectiles capable of causing serious injury.
-
Use the tool only for the intended purpose. Do not abuse the tool. Do not use as a hammer, stamp oren- grave information onto parts, drop or impact the tool or otherwise, apply excessive force to the tool in use. Do not mount the tool to stands or modify it for stationary use.
-
Maintain labels and nameplates. These carry important information. If unreadable or missing, contact ® a MILWAUKEE service facility for a replacement.
WARNING
Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contain chemicals known to cause cancer, birth defects
or other reproductive harm. Some examples of these chemicals are:
- lead from lead-based paint
- crystalline silica from bricks and cement and other masonry products, and
- arsenic and chromium from chemically treated lumber.
Your risk from these exposures varies, depending on how often do you do this
type of work. To reduce your exposure to these chemicals: work in a well-
ventilated area, and work with approved safety equipment, such as those dust
masks that are specially designed to filter out microscopic particles.
Additional safety warnings
WARNING The power tool is under high pressure and the striker has been
lifted to the ready-to-fire position. If a battery is placed on the power tool
and the trigger and workpiece contact are actuated, the tool could fire.
ADDITIONAL BATTERY SAFETY RULES
To reduce the risk of fire, persona injury , and product damage due to a short
circuit, never immerse your tool, battery pack, or charger in fluid or allow a
fluid to flow inside them. Corrosive or conductive fluids, such as seawater ,
certain industrial chemicals, and bleach or bleach-containing products, etc.,
can cause a short circuit.
SPECIFICATIONS
Volts ……………………………………………………. 18 DC
Battery Type ………………………………………….M18™
Charger Type ………………………………………..M18™
Cat. No……. M18CN16GS-0C
16 Ga Straight Finish Nailer
Fastener Length ………………………. min. 19mm (0.75″) ………………………. max. 63mm (2.5″)
Collation Angle ………………………………………………… 0Fastener Size (Diameter) ………………. 16 Ga /
1.6 mm
Magazine Capacity ………………………………….110 nails
Cat. No ……..M18CN16GA-0C
16 Ga Angled Finish Nailer
Fastener Length ………………………. min. 31mm (1.25″) ………………………. max. 63mm (2.5″)
Collation Angle ………………………………………………. 20°
Fastener Size (Diameter) ………………. 16 Ga / 1.6 mm
Magazine Capacity ………………………………… 110 nails
Cat. No ……..M18CN15GA-0C
15 Ga Angled Finish Nailer
Fastener Length ………………………. min. 32mm (1.25″) ………………………. max. 63mm (2.5″)
Collation Angle ………………………………………………. 34°
Fastener Size (Diameter) ………………. 15 Ga / 1.8 mm
Magazine Capacity ………………………………… 110 nails
FUNCTIONAL DESCRIPTION
|
---|---
1. Hook
2. Trigger
3. Handle
4. Power / Actuation
selection
5. Nail slot
6. LED
7. Magazine
8. Pusher
9. Pusher release
button| 10. Workpiece contact
11. Depth adjustment
12. Jam latch
13.Nails
(M18CN16GA-0C)
14.Nails
(M18CN16GS-0C)
15.Nails
(M18CN15GA-0C)
ASSEMBLY
WARNING
Recharge only with the charger specified for the battery. For specific
charging instructions, read the operator’s manual supplied with your charger
and battery. Removing/Inserting the Battery To remove the battery, push in
the release buttons and pull the battery pack away from the tool.
WARNING
Always remove the battery pack before changing or removing accessories. To
insert the battery, slide the pack into the body of the tool. Make sure it
latches securely into place.
Installing/Removing Fastener Strips (Cat. No. M18CN16GS-0C, M18CN16GA-0C, and
M18CN15GA-0C)
WARNING
Always remove the battery pack before changing or removing fasteners. Always
wear safety goggles or glasses with side shields.
Keep fingers clear of fastener track of magazine.
Pusher could pinch fingers, causing injury.
To install fastener strips:
- Remove the battery pack.
- WARNING! Always point the tool away from yourself and others when installing fasteners. Failure to do so could result in injury.
- Slide the fastener strip into the nail slot and down toward the front of the tool. Be sure the point of the fasteners is pointed downward. WARNING! Use only recommended fasteners of the correct size, length, collation angle and head type as indicated on the tool’s nameplate. Other fasteners could result in tool malfunction, leading to injury.
- Press and hold the pusher release button and slide the pusher back past the end of the fastener strips.
- Continue to hold the pusher, but release the button. Slowly slide the pusher forward until it rests against the fastener strip.
To remove fastener strips:
- Remove the battery pack.
- WARNING! Always point the tool away from yourself and others when installing fasteners. Failure to do so could result in injury.
- Press and hold the pusher release button and slide the pusher towards the front of the tool. Release the pusher.
- Slide the nails back and out of the nail slot.
OPERATION
WARNING
To reduce the risk of injury, always wear safety goggles or glasses with side
shields. The operator and other people in the work, area must wear eye
protection in accordance
with ANSI Z87.1.
Eye protection does not fit all operators in the same way. Make sure the eye
protection chosen has side shields or provides protection from flying debris
both from the front end ides. The employer is responsible for enforcing the
use of eye protection by the operator and other people in the work area. When
required, wear head protection in accordance ith ANSIZ89.1. To reduce the risk
of injury to yourself and others, test the tool before beginning work each day
according to the “Required DailyTesting” section.
Do not use the tool unless you thoroughly understand the actuation mode
selected. Remove the battery pack and fasteners beforeleaving the work area,
moving the tool to another location, or handing the tool to another person.
Failure to do so could result in serious injury. Do not use this tool for
fastening electrical cables.
It is not designed for electric cable installation and may damage the
insulation of electric cables thereby causing electric shock or fire hazards.
NEVER wedge or hold back the workpiece contact
mechanism during the operation of the tool. Never attempt to clear a jammed
workpiece contact by grasping the discharge area of the tool. Doing so could
result in serious injury. To avoid serious injury, do not attempt to prevent
the recoil by holding the tool too firmly against the work. Keep face and body
away from the tool. During normal use, the tool will recoil immediately after
driving a fastener. This is a normal function of the tool. Restriction to the
recoil can result in a second fastener being driven when the tool is in
Contact Actuation mode. Grip the handle firmly,let the tool do the work, and
do not place a second hand on top of the tool.
Power/Actuation Selection
-
Install battery pack.
-
Press and hold the Power/Actuation button to turn on the tool.
-
Press the Power/Actuation button again to toggle between single sequential actuation mode and contact (bump) actuation mode.
WARNING! Understand the actuation process before use.
Single Sequential Actuation –
Solid Light – The workpiece contact and then the trigger must be activated in a
specific sequence to drive a fastener.
Contact (Bump) Actuation –
Flashing Light – The workpiece contact and the trigger can be activated in any sequence to drive a fastener. -
Press and hold the Power/Actuation button turn off the tool.
Single Sequential Actuation Operation
- Grip the handle firmly.
- Push the tool against the work surface, compressing the workpiece contact.
- Pull the trigger to drive the fastener. WARNING! To avoid serious injury, do not attempt to prevent the recoil by holding the tool too firmly against the work.
- Remove your finger from the trigger and remove the tool from the workpiece.
Contact (Bump) Actuation Operation
Contact Actuation can follow two different sequences, depending on your use.
Multiple actions:
- Grip the handle firmly.
- Pull and hold the trigger.
- Push the tool against the work surface, compress- ing the workpiece contact to drive the fastener. WARNING! To avoid serious injury, do not attempt to prevent the recoil by holding the tool too firmly against the work.
- Continue to hold the trigger and repeat workpiece contact.
Single actuation:
- Grip the handle firmly.
- Push the tool against the work surface, compressing the workpiece contact.
- Pull the trigger to drive the fastener. WARNING! To avoid serious injury, do not attempt to prevent the recoil by holding the tool too firmly against the work.
- Remove your finger from the trigger and remove the tool from the workpiece.
Reload Indicator
To indicate that the magazine is almost empty of fasteners (about 4-5 left),
the workpiece contact will not compress, preventing operation under usual
pressure. Install more fasteners to continue working.
WARNING
NEVER wedge or hold back the workpiece contact mechanism during the
operation of the tool. Never attempt to clear a jammed workpiece contact by
grasping the discharge area of the tool. Doing so could result in serious
injury.
To avoid serious injury, do not attempt to prevent the recoil by holding
the tool too firmly against the work. Keep face and body away from the tool.
During normal use, the tool will recoil immediately after driving a fastener.
This is a normal function of the tool. Restriction to the recoil can result In
a second fastener being driven when the tool is in Contact Actuation mode.
Grip the handle firmly, let the tool do the work, and do not place a second
hand on top of the tool.
Setting the Depth of Drive
The depth of drive can be adjusted to account for the size of the fastener and
the workpiece material.
WARNING
Know what is behind your workpiece. A fastener could travel through the
workpiece and out the other side, striking a bystander and causing serious
injury. Lower the depth of drive to prevent the fastener from being pushed all
the way through the workpiece.
- Drive a test fastener.
- Remove the battery pack.
- WARNING! Always point the tool away from yourself and others when making adjustments. Failure to do so could result in injury.
- Turn the depth selector left or right to increase or decrease the driving depth.
- Repeat until the desired depth is reached.
Clearing a Jammed Fastener
Most jams are caused by a fastener or part of a fastener wedging between the
driver blade and the nail guide. Fastener strips with an incorrect collation
angle or the wrong fastener gauge may cause continuous jamming. To clear the
jam:
- Remove the battery pack.
- WARNING! Always point the tool away from yourself and others when installing or removing fasteners. Failure to do so could result in injury.
- Remove the fastener strip from the magazine.
- Pull down on the jam latch and pull away from the tool.
- Remove the fastener and other debris (use needlenose pliers if necessary).
- Close jam latch.
- Follow the steps under “Required Daily Testing” before restarting the work.
USER APPLICATIONS
M18CN16GA-0C: Window and door casings, baseboard, crowns, stairs, chair
rail, door frames and exterior moldings
M18CN15GA-0C: Window and door casings, baseboard, crowns, stairs, chair
rail, door frames and exterior moldings
M18CN16GS-0C: Window and door casings, baseboard, crowns, paneling, chair
rail, and door frames
WARNING
The M18CN16GA-0C, M18CN15GA-0C, and M18CN16GS-0C should not be used on metal
studs. Doing so will inhibit the natural operation of the tool.
REQUIRED DAILY TESTING
WARNING
To reduce the risk of injury to yourself and others, test the tool before
beginning work each day or if the tool is dropped, received a sharp blow, been
run over, etc. Complete the following checklist IN ORDER. If the tool does not
work as it should contact a MILWAUKEE ® service facility immediately.
Always point tools away from yourself and others.
-
Remove the battery pack.
-
WARNING! Always point the tool away from yourself and others when installing fasteners. Failure to do so could result in injury.
-
Check all screws, bolts, nuts, and pins on the tool.
Any loose fasteners must be tightened. -
Pull back the fastener pusher on the magazine (to override the Reload Indicator) and press the workpiece contact against a workpiece. It must move smoothly.
-
With the workpiece contact pressed against the workpiece, pull the trigger. It must move smoothly.
-
Insert the battery pack.
-
Select the Single Sequential Actuation Operation. Without pulling the trigger, pull back the fastener pusher on the magazine (to override the Reload Indicator) and press the orkpiece contact against a workpiece. The tool must not operate. Holding the workpiece contact away from the workpiece, pull back the fastener pusher on the magazine (to override the Reload Indicator). Pull and hold the trigger for 5 seconds. The tool must not operate. Continue to pull and hold the trigger and push the workpiece contact against a workpiece. The tool must not operate. Without pulling the trigger, pull back the fastener pusher on the magazine (to override the Reload Indicator) and press the workpiece contact against a workpiece. Pull the trigger. The tool must operate. Release the trigger. The driver must move up.
-
Select the Contact Actuation Operation. Holding the workpiece contact away from the workpiece, pull back the fastener pusher on the magazine (to override the Reload Indicator) and pull the trigger. The tool must not operate. Continue to pull and hold the trigger and push the workpiece contact against a workpiece. The tool must operate.
-
If all previous tests work properly, set the tool for your work. Select the operation and load fastener strips. The M18CN16GA-0C, and
-
et the depth of drive according to the “Setting the Depth of Drive” section. 11. If all tests operate properly, the tool is ready for use. Repeat these tests before use each day if the tool is dropped, received a sharp blow, been run over, jammed, etc.
MAINTENANCE
WARNING
To reduce the risk of injury, always unplug the charger and remove the battery
pack from the charger or tool before performing any maintenance. Never
disassemble the tool, battery pack or charger. Contact a MILWAUKEE ® service
facility for ALL repairs. Maintaining Tool Keep your tool, battery pack, and
charger in good repair by adopting a regular maintenance program. Inspect your
tool for issues such as undue noise, misalignment or binding of moving parts,
breakage of parts, or any other condition that may affect the tool operation.
Return the tool, battery pack, and charger to a MILWAUKEE ® service facility
for repair. After six months to one year, depending n use, return the tool,
battery pack and charger to a MILWAUKEE ® service facility for inspection. If
the tool does not start or operate at full power with a fully charged battery
ack, clean the contacts on the battery pack. If the tool still does not work
properly, return the tool, charger, and battery pack, to the Milwaukee ®
service facility for repairs.
WARNING
To reduce the risk of personal injury and damage, never immerse your tool,
battery pack or charger in liquid or
Cleaning
Clean dust and debris from vents. Keep handles clean, dry, and free of oil or
grease. Use only mild soap and a damp cloth to clean, since certain cleaning
agents and solvents
are harmful to plastics and other insulated parts. Some of these include
gasoline, turpentine, lacquer thinner, paint thinner, chlorinated cleaning
solvents, ammonia and household detergents containing ammonia. Never use
flammable or combustible solvents around tools.
Repairs
For repairs, return the tool, battery pack, and charger to the nearest service center.
ACCESSORIES
WARNING
Use only recommended accessories. Others may be hazardous. For a complete
listing of accessories, go online to
milwaukeetool.com.au/milwaukeetool.co.nz
or contact a distributor.
SYMBOLOGY
| Volts
---|---
| Direct Current
| Solid Light –
Single Sequential Actuation
| Flashing Light –
Contact (Bump) Actuation
| Read Operator’s Manual
| Wear Eye Protection
| Keep Hands Away
| Regulatory Compliance Mark (RCM). This product meets applicable regulatory
requirements.
WARRANTY – AUSTRALIA and NEW ZEALAND
Please refer to Australian and New Zealand warranty supplied with the tool.
This warranty applies only to products sold in Australia and New
Zealand.SERVICE – AUSTRALIA and NEW ZEALAND
MILWAUKEE®prides itself in producing a premium quality product that is Nothing
But Heavy Duty®.
Your satisfaction with our products is very important to us! If you encounter
any problems with the operation of this tool, please contact your authorized
MILWAUKEE® dealer.
For a list of MILWAUKEE® dealers, guarantee or service agents please contact
MILWAUKEE®
Customer Service or visit our website.
(Australia Toll-Free Telephone Number 1300 645 928)
(New Zealand Toll-Free Telephone Number 0800 645 928)
or visit
milwaukeetool.com.au/milwaukeetool.co.nz.
Milwaukee Electric Tool Corporation
13135 West Lisbon Road, Brookfield, Wisconsin U.S.A. 53005
Milwaukee Tool (Australia)
21 Kellett’s Road, Rowville, VIC 3178
Melbourne, Australia
Milwaukee Tool (New Zealand)
274 Church Street, Penrose,
Auckland, 1061, New Zealand
Designed by Milwaukee Electric Tool Corp.
Professionally Made in China for Milwaukee Tool (Australia) / Milwaukee Tool
(New Zealand)
Printed in China
961016185-02(A)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>