Table of Contents
General Safety ……………………………………………………………………………………………………. 2 Preparation for
Installation ……………………………………………………………………………………………. 3 Parts List
………………………………………………………………………………………………………………. 4 Extra
Parts…………………………………………………………………………………………………………4 Accessories Parts (Included in
some models, refers to the actual package) …………………………………… 5 Optional
Accessories Parts List (Available at TOPENS Store) ……………………………………………………… 5
Technical Specifications & Features ……………………………………………………………………………. 5
Installation Overview …………………………………………………………………………………………………. 6 Installation of
the Opener ………………………………………………………………………………………………6 Manual Operation
……………………………………………………………………………………………………. 7 Fit The Rack
………………………………………………………………………………………………………….. 8 Installation of the Magnets
………………………………………………………………………………..9 Connecting of AC Main Power Supply
…………………………………………………………………………… 9 Connecting of the Batteries & Solar Panels &
Solar Controller ………………………………………………. 10 Connecting of the Control Board
………………………………………………………………………………… 11 Setting of the Control Board
………………………………………………………………………………………. 13 Test the Reversing Sensitivity
……………………………………………………………………………………….. 15 How to Program or Erase the Remote
…………………………………………………………………………… 15 How to Use the Remote to Operate Your Gate
Opener ……………………………………………………….. 16 Wireless Keypad Programming
………………………………………………………………………………….. 16 Trouble Shooting
………………………………………………………………………………………………… 17 Maintenance
………………………………………………………………………………………………… 18
1
Thank you for purchasing our sliding gate opener. We are sure that the
products will be greatly satisfying as soon as you start to use it. The
product is supplied with a user’s manual which encloses installation and
safety precautions. These should be read carefully before installation and
operation as they provide important information about safety, installation,
operation and maintenance. This product complies with the recognized technical
standards and safety regulations.
General Safety
WARNING! An incorrect installation or improper use of the product can cause
damage to persons, animals or properties. · Scrap packing materials (plastic,
cardboard, polystyrene etc.) according to the provisions set out by current
standards. Keep nylon or polystyrene bags out of children’s reach. · This
product was exclusively designed and manufactured for the use specified in the
present documentation. Any other use not specified in this documentation could
damage the product and be dangerous. · The factory declines all responsibility
for any consequences resulting from improper use of the product, or use which
is different from that expected and specified in the present documentation. ·
Do not install the product in explosive atmosphere. · The factory declines all
responsibility for any consequences resulting from failure to observe Good
Technical Practice when constructing closing structures (door, gates etc.), as
well as from any deformation which might occur during use. · Disconnect the
electrical power supply before carrying out any work on the installation. Also
disconnect any buffer batteries, if fitted. · Fit an omnipolar or
magnetothermal switch on the mains power supply, having a contact opening
distance equal to or greater than 3,5 mm. · Make sure a residual current
circuit breaker with a 30mA threshold is fitted before the power supply mains.
· Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an earth
terminal. · Fit all the safety devices (photocells, electric edges etc.) which
are needed to protect the area from any danger caused by squashing, conveying
and shearing. · Position at least one visible indication device (Alarm lamp),
and fix a Warning sign to the structure.
· The factory declines all responsibility with respect to the automation
safety and correct operation when other supplier’s components are used. · Only
use original parts for any maintenance or repair operation. · Do not modify
the automation components, unless explicitly authorized by the factory. ·
Instruct the product user about the control systems provided and the manual
opening operation in case of emergency.
2
· Do not allow persons or children to remain in the automation operation area.
· Keep radio control or other control devices out of children’s reach, in
order to avoid unintentional automation activation. · The user must avoid any
attempt to carry out work or repair on the automation system, and always
request the assistance of qualified personnel. · Anything which is not
expressly provided for in the present instructions is not allowed. · Before
installing the gate opener, check that all moving part as well as the sliding
gate is in good mechanical condition, correctly balanced and opens and closes
properly. · Save these instructions for future use.
Preparation for Installation
Before proceeding to your opener installation, check if your gate structure is
in accordance with the current standards, especially as follows: The gate
sliding track is linear and horizontal. The wheels are suitable for use. The
gate should be mounted and moved freely. Check that the structure is
sufficiently strong and rigid, and that its dimensions and weights conform to
those listed in the specifications table of this document. Make sure that the
gate is plumb and level. The fence posts must be mounted in concrete. The gate
does not bind or drag on the ground. · The gate manual operation can be
carried out smoothly along its entire run, and there is no excessive side
slipping. · The opening and closing gate stops are positioned.
WARNING: Remember that control devices are intended to facilitate gate
operation, but can not solve problems due to any defects or deficiency
resulting from failure to carry out correct installation or maintenance. Take
the product out of its packing and inspect it for damage. Should it be
damaged, contact your dealer. Remember to dispose of its components
(cardboard, polystyrene, nylon, etc.) according to the current prescriptions.
Refer to the following Figures for gate installation.
In sake of safety, a positive stop must be mounted on the two end of ground
track.
3
Parts List
Extra Parts
4
Rev 20a
Accessories Parts (Included in some models, refers to the actual package) Optional Accessories Parts List (Available at TOPENS Store)
Technical Specifications & Features
Model: Power supply: Motor voltage: Absorbed power: Gate moving speed: Max
gate weight:
Max torque: Environmental conditions:
Protection class:
Specifications
DK1000(S/Y/T) 110V~120V/60Hz or 220~240V/50Hz
24VDC 350W 20 cm/s (8 in/s) 800kg (1800lbs) 16Nm
-20~ +50 (-4°F to 122°F)
IP44
5
Rev 20a
Features:
·Soft start and soft stop ·Midway mode. ·Quick selection for the gate
open/close direction ·Reliable rolling code technology for remote control
·Emergency release key in case of power failure ·Stop in case of obstruction
during gate opening ·Reverse in case of obstruction during gate closing ·Built
in adjustable auto-close (none, 30, 60, 90 seconds) ·Built in max. Motor
Running Time (MRT) for multiple safety protection (90 seconds) ·Reliable
electromagnetism limit for easy adjustment ·Can be equipped with a wide range
accessories ·Easy to install, and minimum maintenance requirement
Installation Overview
Installation of the Opener
Caution: *Be sure that the opener is installed in a horizontal and paralleled position and is properly secured. Improper installation could result in property damage, severe injury, and/or death.
6
Rev 20a
- Before starting installation, ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailment. * Ensure that the Warning Signs are present. Necessary Tools: The following tools may be necessary to install the Gate opener. You will need screwdrivers, an electric drill, wire cutters and a wire stripper, a socket set, and possibly access to a welder. When install the opener, you should build a concrete pad to support the base plate of opener in order to maintain proper stability. The installation proceeds are as follows: 1.Dig a hole for a concrete pad which should be approximately 600 x 320 x 350mm (24 x 13x 14). It may protrude 100mm (4″) above ground and 250mm (10″) in depth underground. Increase the pad height if necessary to protect the system from flooding, heavy snow etc. 2. Prepare one or more conduits for the electrical cables before pouring concrete. Remember that cable conduits have to pass through the hole in the base plate. 3. Pour concrete and before it starts to harden, check that it is parallel to the gate leaf and perfectly level. 4. The four anchor bolts must be set into the concrete when it is poured, make sure the position of anchor bolts was placed according to the position of mounting holes on the base plate before concrete become harden. 5. Mount the base plate to the concrete pad. 6. Place the opener onto base plate. Check that it is perfectly parallel to the gate, and then screw the four bolts and washers supplied. It’s only temporary installation. Further adjustment will be required when install the rack.
Manual Operation
The opener should be put in the manual (emergency release) position before fitting the rack, installing the opener and limit switch. The process is as follows: 1) Take off the rubber stopple. 2) Insert the Release Keyprovidedand turn it in counter-clockwise 180° to disengage the clutch between the gear shaft and power output. Now the opener is in the manual operation.
7
Fit the Rack
There are two kinds of rack available as per your options, which are steel
reinforced plastic rack and galvanized steel rack. The galvanized steel rack
is usually used for the heavy duty gate.
A. Fit the plastic rack reinforced with steel
1. Start with gate in closed position 2. There are four sections of plastic
rack which is one meter length. (you can order extra rack from dealer if
necessary) 3. Put one end of rack section on the gear of opener as a temporary
support. Make rack level and mark the rack’s mounting holes (four holes for
light duty or six holes for heavy duty) on the gate. 4. Fit the rack by self-
threading screws. This kind of plastic rack is quieter and allows height
adjustments to be made even after it has been fixed. Please keep 1.0mm space
between the rack and the gear to avoid the weight of the gate effect on the
opener.
B. Fit the galvanized steel rack
1. Start with gate in closed position 2. There are four sections of steel
rack which is one meter length. (you can order extra rack from dealer if
necessary)
8
3. Put one end of rack section on the gear of opener as a temporary support.
Make rack level and mark the rack’s mounting holes (three holes) on the gate.
4. Weld the rack nut on the gate as mark and connect the rack to the gate
using the bolt provided. Before weld, please keep 1.0mm space between the rack
and the gear to avoid the weight of the gate effect on the opener.
Installation of the Magnets
Before install limit switch, make sure the gate opener is put in manual
operation. (the clutch connected with gear shaft is disengaged) and the mains
power supply is disconnected. Position the S&N Magnet Components approximately
on the gate and move the gate by hand to fix them in place.
Fit magnets bracket
Push the gate fully closed by hand. Locate and install the magnet bracket so
that the opener will stop at the desired close position when the close limit
switch approaches it. Push the gate fully open by hand. Locate and install the
magnet bracket so that the opener will stop at the desired open position when
the open limit switch approaches it. The magnet component with S pole outside
must be installed at left side and the magnet component with N pole outside
must be installed at right side from the view inside of property. Ensure
magnet center to align with the marked line above ! The magnets should be
20~30mm away from the Limit Switch Box. If it is too near or too far, the
switches will fail to work. Adjust the position of the magnets until the
positions of the opening and closing meet the requirement.
Warning: Improper magnets installation may cause the gate crash into end
barrier, which is very dangerous !
Important:
- Check that the rack teeth must engage the gear teeth throughout their full thickness. If not, adjust the position of the opener or/and place a few shims between the rack and gate. Manually slide the gate leaf to ensure the rack is proper on the gear of opener. Repeat same steps of first rack section to install the rest rack sections until proper length is reached. Cut away any excess of the rack (Note: rack length must be longer than actual travel of the gate) Thoroughly fasten the four nuts as well as spring washers onto expansion bolts tightly, enabling the opener is firmly secured on the concrete pad during the whole gate travel.
Connecting of AC Main Power Supply
WARNING: NEVER connect the gate opener to the power outlet before all the installations have been done. The power supply cord should be at least 3×0.75mm2 (3C×18AWG). Connect the live wire, neutral wire and earth wire to the “L”, “N” and “PE” terminals respectively. It is strongly recommended that an emergency stop switch (NOT PROVIDED IN PACKAGE) is installed in the electrical system which can be used in case of the remote control failure. You can connect the switch by the following steps:
9
1. Cut off the wire which has been connected between terminal 4 and 5 in
factory to deactivate the existed short circuit of terminal 4 and 5. 2. Solder
the two wires to the terminals of the switch respectively. NOTE: The power
supply cord is not included in the package. NOTE: Make sure a residual current
circuit breaker with a 30mA threshold is fitted before the power supply mains.
NOTE: The protection class of the emergency stop switch should be at least
IP44.
Connecting of the Batteries & Solar Panels & Solar Controller
WARNING: NEVER connect the gate opener to the power outlet before all the
installations have been done. NOTE: 1. The batteries (ONLY included in Y
Series) can be used as back-up power or main power. The wire connection is
different for the two conditions. 2. If batteries as are chosen as the power
source, Marine or Automotive Type Battery is required. The batteries should be
waterproof type, or be placed in water proof circumstance. 3. 2 PCS 12VDC
batteries can be connected in series to function as 24VDC. The following
diagram shows on how to connect 2 PCS batteries in series. Charging mode for
the battery could be only by the solar panel OR both of the solar panel and
the AC electricity at the same time. 4. Please note that the wire connection
of the power supply system is very important. Incorrect wire connection will
damage the control board.
1. Using with the AC electricity at the same time
The gate opener can be powered by the AC electricity and the batteries at the
same time. The batteries are used as back-up power source in case of AC power
failure. In this situation, 5AH batteries are enough if the power failure time
is less than 8 hours per day. Please connect the batteries & the solar panels
& solar controller refer to the following illustration.
10
2. Using without AC electricity
The gate opener also can be powered by 2 PCS 12VDC batteries (ONLY included in
Y Series) as the main power supply with a 24VDC solar panel to charge it. The
capacity of the batteries should be at least 12AH and the power of the solar
panel should be at least 30W if there is totally no AC electricity. The gate
opener can run for 10 cycles per day without connecting any other accessories
except pushbutton & alarm lamp if the local average sunshine time is more than
6 hours per day. The power of the solar panel and the capacity of the
batteries should be enlarged if the local average sunshine time is less than 6
hours per day or using one of the accessories (photocell, external receiver,
exit wand and keypad). Please provide us with more details of the local
sunshine condition and accessories needs which we can calculate the
configuration of the solar panel and the batteries. Please connect the
batteries & the solar panels & solar controller refer to the following
illustration if you want use the gate opener totally without the AC
electricity.
Connecting of the Control Board
1. Motor
The YELLOW wire of the motor should be connected into the “1” terminal. The
RED wire of the motor should be connected into the “2” terminal.
2. Limit Switches
The YELLOW wire of the limit switches should be connected into the “3”
terminal. The BLACK wire of the limit switches should be connected into the
“4” terminal. The RED wire of the limit switches should be connected into the
“5” terminal.
3. Warning Light (Included in some models, refers to the actual package)
The WHITE wire of the warning light should be connected into the “6” terminal.
The RED wire of the warning light should be connected into the “7” terminal.
4. Photocell Beam System (PBS) (Included in some models, refers to the actual
package)
11
Use a 2-core cable to connect the “- ~” terminal of the photocell’s emitter to
the “19” terminal, the “+ ~” terminal to the “18” terminal. Also the “- ~” and
“+ ~” terminals of the photocell’s receiver should be connected to the “19”
and “18” terminals in parallel. Use another 2-core cable to connect the “NC”
terminal of the receiver to the “13” terminal, the “COM” terminal to the “12”
terminal.
5. Push Button (optional)
The push button should be wired to the “16 and “17” terminals. No matter the
polarity. The gate operator works alternately by pressing the button (open-
stop-close-stop-open).
6. Exit Wand (optional)
The BLACK wire of the exit wand should be connected into the “14” terminal.
The BLUE wire of the exit wand should be connected into the “15” terminal. The
RED wire of the exit wand should be connected into the “18” terminal. The
GREEN wire of the exit wand should be connected into the “19” terminal. The
sensitivity adjustment board should be wired to the GREEN wire and the YELLOW
wire of the wand. No matter the polarity.
12
7. Battery (ONLY included in Y Series)
The “24V+” of the battery should be wired to the BAT+ (11) terminal, “24V-”
should be wired to “-BAT” (10) terminal. If the battery has been used with
solar panel, please connect the batteries and the solar panel &solar
controller refers to the chapter “Connecting of the Batteries & the Solar
Panel & Solar Controller”.
8. External Receiver (optional)
The BROWN wire of the external receiver should be connected into the “16”
terminal. The BLACK wire of the external receiver should be connected into the
“17” terminal. The RED wire of the external receiver should be connected into
the “18” terminal.
9. Wired Keypad (24VDC) (optional)
The RED wire of the wired keypad should be connected into the “18” terminal.
The BLACK wire of the wired keypad should be connected into the “17” terminal.
The BLUE wire of the wired keypad should be connected into the “16” terminal.
The PURPLE wire of the wired keypad should be connected into the “17”
terminal. NOTE: Using of the photocell, exit wand, keypad and external
receiver would cause the battery exhausted quickly. Big capacity of batteries
and big power of solar panel is required if you want to use any one of them
(If the batteries and solar panel is used as main power supply).
Setting of the Control Board
WARNING: Ensure the gate opener is Power Off when you make any adjustment of
the gate opener. Keep away from the path of the gate during you set the gate
opener system in case of the unexpected gate moving. Carefully adjust the DIP
switches to avoid the risk of machine damage and injury or death. Always ask
the help of professional technician /electrician if you have any question.
1. DIP Switches The DIP switches are used to set the running time of the
motor in midway mode, fine adjust the soft stop period of the motor, auto
close time of the gate opener and fast change the open/close direction which
is determined by the position of the gate opener installed. DIP Switch #1#2:
Running time of the motor in Midway Mode DIP Switch #1: ON 2 Seconds OFF 0
13
DIP Switch #2: ON 4 Seconds OFF 0 NOTE: The midway mode function would be disabled if both DIP switches are turned off. Factory default setting is disabled. The midway mode could be activated by pressing button B of the remote control when the gate is in the full closed position.
E.g.
Running time of the opener in midway mode is 2+4=6 seconds.
DIP Switch #3#5: Fine adjust the soft stop period of the motor DIP Switch #3: ON 1 Second OFF 0 DIP Switch #4: ON 2 Seconds OFF 0 DIP Switch #5: ON 3 Seconds OFF 0 NOTE: Every time you restart the gate opener after power off, you should use the access control device (such as remote, push button and etc.) to operate the gate opener to run for a complete opening cycle and a complete closing cycle to get the full opening time and the full closing time. You would achieve the soft stop in your next opening/closing cycle. Factory default soft stop time is 3 Second. You can turn the DIP switches on/off to fine adjust the soft stop time to meet your actual needs.
E.g.
The soft stop period of the motor is 1+2=3 seconds.
DIP Switch #6#7: Auto close time of the gate opener DIP Switch #6: ON 30 Seconds OFF 0 DIP Switch #7: ON 60 Seconds OFF 0 NOTE: The auto close function would be disabled if both DIP switches are turned to off (factory default setting).
E.g.
Auto close time of the gate opener is 30+60=90 seconds.
DIP Switch #8: Left/Right open
14
2. Potentiometers Potentiometer A is used to adjust the close stall force the
gate operator. Turn clockwise to increase the stall force, and turn it
counter-clockwise to decrease the stall force. Potentiometer B is used to
adjust the open stall force the gate operator. Turn clockwise to increase the
stall force, and turn it counter-clockwise to decrease the stall force.
WARNING: Photocell is highly recommended to be installed with the gate opener
as entrapment protection for safety when you set stall force to maximum.
Test the Reversing Sensitivity
For the sake of safety, it is very important to test the reversing sensitivity
as soon as the control board set is finished. The reversing sensitivity
adjustment is inverse correlation with stall force adjustment in potentiometer
A and B. In other word, the stall force level is higher; the reversing
sensitivity level is lower. Put an immobile object along the gate path, and
then operate the gate to strike it during the close cycles. The gate must
reverse as soon as object is struck with it. If the gate doesn’t reverse,
please increase the reversing sensitivity by turning the potentiometer in
counter-clockwise direction. (Turning the stall force potentiometer toward to
MIN position to increase the reversing sensitivity) Note 1: If the sensitivity
setting is too higher, the gate will stop or reverses very easy by itself
while there is little obstruction or resistance such as strong wind or heavy
snow sometimes. Note 2: Always check the gate reversing function every each
time of control board set or restart after power off.
How to Program or Erase the Remote
The remote MUST be programed to the opener BEFORE OPERATING. Please follow the
steps to program the remote.
Activate the opener only when gate is in full view, free of obstruction and
properly adjusted. No one should enter or leave gate area while gate is in
motion. DO NOT ALLOW CHILDREN to operate push button or remote. DO NOT ALLOW
CHILDREN TO PLAY NEAR THE GATE.
If you purchase additional remote controls, the gate opener must be programmed
to accept the new remote code.
If you lose one of any remote control, please erase and reprogram all other
remote controls to have a new code for safety.
Program the remote Press and release the learn button, the REM LED light will
be on, then press the key in the remote twice in 2 seconds, the REM LED light
will flash for 4 seconds. Now the remote has been programmed successfully.
Erase all the remote codes Press and hold the learn button until the REM LED
light is off. Now all remote codes have been erased. NOTE: Max. 8 remotes can
be programmed for the opener. An External Receiver (optional) allows up to
15
250pcs remotes to be programmed for the opener. TOPENS ERM12 Universal
External Receiver is available at TOPENS Store. TOPENS ERM12 Universal
External Receiver is also compatible with other brand swing gate opener,
sliding gate opener and garage door opener.
How to Use the Remote to Operate Your Gate Opener
Each remote has four buttons, from top to bottom are separately A, B, C and D.
You may use this remote to operate as many as 4 sets TOPENS swing gate openers
or 1 set TOPENS sliding gate opener and 2 sets TOPENS swing gate openers. 1.
Use this remote to only operate TOPENS swing gate opener A, B, C and D four
buttons share same function once they are programmed with TOPENS swing gate
opener. You may choose any button to program it with our swing gate opener.
Every press of the button is able to active the gate opener to work
alternately (open-stop-close-stop-open). 2. Use one remote to operate TOPENS
swing gate opener & sliding gate opener at the same time All of TOPENS sliding
gate opener have midway mode. Button B is designed to realize midway function
(refer to more details in our TOPENS sliding gate opener manual). So it is
must program button A with sliding gate opener, while you may program either C
button or D button with TOPENS swing gate opener.
Wireless Keypad Programming
You can follow the below steps to program wireless keypad to the opener. Press
the Learn button until the REM LED is ON, and then releases the button. Then
press “OK” button on keypad and REM LED will flash for 3 seconds and then be
OFF which indicates the keypad has been programmed successfully. You can use
the default password “888888” to operate the opener after programming. You can
press “PIN” “8 8 8 8 8 8” and then press “OK” to confirm to operate the
opener. Also you can change the password of the keypad follow the below steps.
Press “PIN” and then input the six digits old password and then press “PIN”
again, the REM LED will be ON. Input the six digits new password and then
press the “PIN” to confirm the new setting, REM LED will flash for 3 seconds
and then be OFF which indicates the password has been changed successfully.
You can press “PIN” “6 digits new password” and then press “OK” to confirm to
operate the opener.
NOTE: Every step for pressing button during program must be finished within 1
second to ensure successful programming.
16
Troubleshooting
Have a multi-meter to check voltage and continuity. Use caution when checking
high voltage terminals.
Symptom
Possible Solution(s)
The opener does not run. Power LED is OFF.
1. Make sure that the power cord is properly plugged into the mains outlet. 2. Check if the output voltage of the transformer is 24VAC. If the voltage measures 0, the transformer may be overheated or damaged. Turn power off and allow board to cool for several minutes then reset. Replace the transformer if the symptom still exists. 3. Check the fuse in the control board. Replace the fuse if it was burnt out. 4. Check the status of the over-discharged LED on the solar controller, the voltage of the batteries is too low to power the gate opener if the LED is ON. Please wait the batteries are charged to full. 5. The solar controller could be faulty if the over-discharged LED is ON when the voltage of the batteries is normal (>24VDC). 6. Check the control board. Replace the control board if necessary.
The opener does not run. Power LED is ON.
1. Check to be sure the beam is not blocked if a photocell is used as a secondary entrapment prevention device. If a photocell is not used, photocell terminal of the control board should be shorted by a jumper wire. 2. Check the motor. Release the clutch then disconnect the wires of the motor from terminal 1 and 2. Connect the wires to 24V battery directly, the motor should run, and then exchange the wires, the motor should run in the opposite direction. If the motor runs in both directions, please check the other parts listed below. 3. Check the limit switch. Use a jumper wire to short terminal 4 with terminal 3 and 5, and then use a keying device to operate the opener, replace the limit switch if the motor could run in both directions. 4. Check the control board. Replace the control board if necessary.
Remote control does not work.
1. The indicator light of remote control is not on. Check the battery in your remote control. Replace the battery if necessary. 2. The distance you use the remote is too far away from the opener. Try it again closer. 3. Remote control is not suitable for receiver. After making sure the codes are correct, erase remote controls and then re-program the codes in the device. 4. Check the control board. Replace the control board if necessary.
The gate starts but it is immediately stop or reverse
1. Check the HALL sensor board in the side of the gear box has been connected to the control board tightly. 2. Check that the clutch is adjusted properly and is not slipping. 3. The opening force or closing force is adjusted too small. Turn the Potentiometer A&B to increase the force. 4. Disconnect the gate from the gate opener and check that the gate slides freely without any binding. 5. Check the control board. Replace the control board if necessary.
17
The gate opens, but stops and will not return.
1. Please note the two limit magnets are different: one is N pole and another is S pole. Please try to exchange the two magnets. 2. Please try to exchange the limit switch wires CL (close) and OP (open). 3. Maybe the magnet was installed in the wrong position so it inducts both switches. Adjust the magnets to the correct position refer to the manual. 4. Check the control board. Replace the control board if necessary.
The gate can open, but fails to close.
1. Photocell is obstructed. Remove obstruction. 2. The limit switch is failed. Use a jumper wire to short terminal 4 with terminal 3 and 5, and then use a keying device to operate the opener, replace the limit switch if the motor could run in both directions. 3. Check the control board. Replace the control board if necessary.
Maintenance
Every six months check the following items for proper operation of the unit.
Lubricate shafts and gears. Keep opener clean at all times. Check and
tighten anchors bolts. Check for loose or corroded wire Ensure the opener
is well earthed, and correctly terminated. Always check the Stop/Reverse in
case of obstruction function when performing any maintenance. If this function
can’t be made operable, remove this opener from service until the cause of the
malfunction is identified and corrected.
18
TOPENS Website
http://www.topenstool.com/
Any question, please do not hesitate to contact us: E-mail:
support@topenstool.com
Kindly include your Product Model, Purchasing Date & Site, Order #, and your
contact information. All your concerns will be replied within 24 hours.
Tel: +86 (571) 8908 0213 (China) Mon-Fri 9:00AM-5:30PM (UTC +08:00)
19
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>