Honeywell Programmable Digital Thermostat
PRO 4000 Series Programmable Digital Thermostat
Read and save these instructions.
Your new thermostat is pre-programmed. Just set the time and day. For help
please visit yourhome.honeywell.com
Thermostat controls
Display screen
Set the time and day
1. Press the SET button, then press ▲ or ▼ to set the clock time.
2. Press the SET button, then press ▲ or ▼ to select the day of the week.
3. Press RUN to save & exit
Note: If the display flashes Set Clock, the thermostat will follow your settings for the weekday “Wake” time period until you reset the time and day.
Save money by setting program schedules
| Set to the time you
awaken and the temperature you want during the morning, until you leave for
the day.
---|---
| Set to the time you
leave home and the temperature you want while you are away (usually an energy-
saving level).
| Set to the time you
return home and the temperature you want during the evening, until bedtime.
| Set to the time you
go to bed and the temperature you want overnight (usually an energy-saving
level).
This thermostat is pre-set with energy-saving program settings. We recommend
these settings, since they can reduce your heating/cooling expenses. If you
need to create a new schedule follow the steps on the next page.
To adjust program schedules
- Press SET until Set Schedule is displayed.
- Press ▲ or ▼ to set your weekday Wake time (Mon-Fri), then press SET.
- Press ▲ or ▼ to set the temperature for this time period, then press SET.
-
Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
-
Press SET to set weekend time periods (Sat-Sun), then press RUN to save & exit.
Note: Make sure the thermostat is set to the system you want to program
(Heat or Cool).
Note: To cancel an unwanted time period (except Wake), press and hold ▲
+ HOLD for 4 seconds while in the Set Schedule mode.
Program schedule override (temporary)
Press ▲ or ▼ to immediately adjust the temperature. This will temporarily
override the temperature setting for the current time period.
The new temperature will be maintained only until the next programmed time period begins. For example, if you want to turn up the heat early in the morning, it will automatically be lowered later, when you leave for the day.
To cancel the temporary setting at any time, press RUN.
Note : Make sure the thermostat is set to the system you want to control (heat or cool).
Program schedule override (permanent)
Press HOLD to permanently adjust the temperature. This will override the
temperature settings for all time periods.
The “Hold” feature turns off the program schedule and allows you to adjust the
thermostat manually, as needed.
Whatever temperature you set will be maintained 24 hours a day, until you
manually change it, or press RUN to cancel “Hold” and resume the program
schedule.
This feature helps prevent damage to the compressor in your air conditioning
or heat pump system.
Note : Make sure the thermostat is set to the system you want to control (heat or cool).
Adaptive Intelligent Recovery™ (AIR)
Adaptive Intelligent Recovery eliminates guesswork when setting your schedule.
It allows the thermostat to “learn” how long your furnace and air conditioner
take to reach the temperature you want.
Just set your program schedule to the time you want the house to reach your
desired temperature. The thermostat then turns on the heating or cooling at
just the right time to reach your scheduled temperature at your scheduled
time.
For example: Set the Wake time to 6 am and the temperature to 70°. The heat
will come on before 6 am, so the temperature is 70° by the time you wake at 6.
Built-in compressor protection
Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait for a few minutes before restarting.
During the wait time, the display will flash the message Cool On (or Heat On
if you have a heat pump). When the safe wait time has elapsed, the message
stops flashing and the compressor turns on.
Battery replacement
Batteries are optional (for backup power) if your thermostat was wired to run on AC power when installed. Install fresh batteries when the REPLACE BATT warning begins flashing. The warning flashes about two months before the batteries are depleted.
Replace batteries once a year, or before leaving home for more than a month.
If batteries are inserted within one minute, the time and day will not have to
be reset. All other settings are permanently stored in memory, and do not
require battery power.
Quick Reference
Grasp and pull to see basic operating instructions at a glance.
Customer assistance
For assistance with this product, please visit www.yourhome.honeywell.com. Or call Honeywell Customer Care toll-free at 1-800-468-1502.
CAUTION
Equipment damage hazard
To prevent possible compressor damage, do not operate cooling system when
outdoor temperature is below 50°F (10°C).
Troubleshooting
If you have difficulty with your thermostat, please try the following
suggestions.
Most problems can be corrected quickly and easily.
Display is blank|
- Check circuit breaker and reset if necessary.
- Make sure power switch at heating & cooling system is on.
- Make sure furnace door is closed securely.
- Make sure fresh AA alkaline batteries are correctly installed ( Check above )
---|---
Heating or cooling system does not respond|
- Set system switch to Heat ( Check above ). Make sure the temperature is set higher than the Inside temperature.
- Set system switch to Cool ( Check above ). Make sure the temperature is set lower than the Inside temperature.
- Wait 5 minutes for the system to respond.
Temperature settings do not change| Make sure heating and cooling temperatures are set to acceptable ranges:
- Heat: 40° to 90°F (4.5° to 32°C).
- Cool: 50° to 99°F (10° to 37°C).
Cool On” or “Heat On” is flashing|
- Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor ( Check above ).
“Heat On” is not displayed|
- Set the System switch to Heat, and set the temperature level above the current room temperature ( Check above ).
“Cool On” is not displayed|
- Set the System switch to Cool, and set the temperature level below the current room temperature ( Check above ).
5-year limited warranty
Honeywell warrants this product, excluding battery, to be free from defects in
the workmanship or materials, under normal use and service, for a period of
five (5) years from the date of purchase by the consumer. If at any time
during the warranty period the product is determined to be defective or
malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the
place from which you purchased it; or
(ii) call Honeywell Customer Care at
1-800-468-1502. Customer Care will make
the determination whether the product should be returned to the following
address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley,
MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty
shall not apply if it is shown by Honeywell that the defect or malfunction was
caused by damage which occurred while the product was in the possession of a
consumer.
Honeywell’s sole responsibility shall be to repair or replace the product
within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR
IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT.
THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE
FIVE-YEAR DURATION OF THIS WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts, so
the above limitation may not apply to you. This warranty gives you specific
legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Honeywell
Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call
1-800-468-1502. In Canada, write Retail
Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive,
Toronto, Ontario M1V4Z9.
Automation and Control Solutions
Honeywell International Inc. Honeywell Ltd
1985 Douglas Drive North 705 Montrichard Avenue
Golden Valley, MN 55422 Saint-Jean-sur-Richelieu, Québec
yourhome.honeywell.com J2X 5K8
® U.S. Registered Trademark.
© 2013 Honeywell International Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>