Honeywell Lyric C2 Wi-Fi Security Camera Installation Guide

June 7, 2024
Honeywell

logo

Honeywell Lyric C2 Wi-Fi Security Camera

product

Download the Honeywell Lyric app

NOTE : Have your Wi-Fi password available and confirm your router is dual-band and communicates at 2.4/5 GHz before installation.

  1. Make sure bluetooth is enabled on your mobile device.
  2. Search for Honeywell Lyric in the App Store or Google Play.
  3. Download the Honeywell Lyric app.

Installation

Launch the Lyric app

1 Launch the Lyric app.
2 Select the Lyric C2 Wi-Fi Camera to install, then create an account (if necessary), or sign in to your Lyric account.
3 Follow the instructions in the Lyric app to name the camera and its location.

Connect the power cord
  1. Plug the power cord’s USB end into the wall outlet adapter.
  2. Plug your camera into a power outlet.
  3. Wait until the LED on the camera blinks blue (about 1 minute), then tap NEXT.

image 1

NOTE: If the LED turns solid red, it means the connection mode timed out. Unplug the camera and plug it back in.

Connect

Connect to mobile device
  1. Enable bluetooth on your mobile device.
  2. The app will look for the camera.
    • For one camera, it will connect automatically.
    • For more than one camera, the app will prompt you to select one camera at a time. Each camera has a unique MAC ID printed on the back. Use that ID to select the camera you want to connect.
  3. A QR code will display in the app. To connect your camera to the app, hold the QR code approximately 3-6 inches (7-15 cm) from the camera lens.
  4. The camera LED turns purple and the camera beeps.
Connect to Wi-Fi

Be sure you are on the same Wi-Fi network you wish to connect your camera to.

  1. Choose your Wi-Fi network from the list. Tap NEXT.
  2. Enter your Wi-Fi password, if necessary. Tap DONE.

NOTE: The camera will beep during some steps in this process.

Wi-Fi connection LEDs

During Wi-Fi connection, the LED indicates the following.

LED Camera state
Blinking Green Connecting to Wi-Fi network.
Solid Green Connected to Wi-Fi network.
Solid Red (for 2 seconds) Connection failed. LED will then turn solid purple.
Solid Purple QR Code scan complete.

Re-start “Connect to Wi-Fi” on page 3.
Blinking Blue| Camera has lost bluetooth connection. Unplug camera and plug it back in. See “Connect the power cord” on page 2 for instructions.

Placement

With stand
Place the camera in a desired location for viewing and recording.image
2

On the wall
You can also mount the camera directly to the wall without the stand.image 3

Operation

Lyric app experience
When you launch the application, live video from your camera is displayed.
If you have multiple cameras, a list of them is displayed. Select a camera from the list to view live video from that camera.

Testing smoke/CO alarm detection
If your smoke or carbon monoxide alarm goes off and your camera is on, it will send you an alert that a smoke or CO alarm has been detected.
To test this feature, press and hold the Test button on your smoke/CO detector for at least 5 seconds or 3 cycles of the detector’s alarm. A shorter test might not trigger a sound event.

Camera overview

image 4

Reset
If your Wi-Fi connection fails or you need to connect to a different Wi-Fi network, insert one end of a paperclip into the reset hole. Press and hold it for 10 seconds until you hear a chirp.

SD card
The camera comes with an encrypted 8GB SD card installed. It stores images if the camera’s connection to the cloud is lost. You can replace it with any compatible SD card.

Status LED

The camera has an LED that gives device status.

LED Camera state

During installation
Blinking Blue| Powered up. Ready to begin setup.
Solid Blue| Connected to App. Ready to complete setup.
Solid Purple| QR Code scan complete. Re-start Connect to Wi-Fi process.
Blinking Green| Connecting to Wi-Fi network.
Solid Green| Connected to Wi-Fi and operating.
Solid Red| Setup timed out. Unplug camera, plug it back in, and restart the process.
During operation
Blinking Green| Connecting to Wi-Fi network.
Solid Green| Connected to Wi-Fi and operating.
Blinking Red| Not connected to Wi-Fi.

FCC Regulations

§ 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

§ 15.21
Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment.

§ 15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

IC Regulations

This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:
(1)this device may not cause interference, and (2)this device must accept any interference, including interference that may cause undesired operation of the device.

IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Need help?
Web: yourhome.honeywell.com
Email: MyLyric@honeywell.com
Phone: 1-800-633-3991

logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals