ULINE H-4377 Rotary Drum Pump Instruction Manual

June 7, 2024
ULINE

H-4377 ROTARY DRUM PUMP

1-800-295-5510

uline.com

ULINE H-4377 Rotary Drum Pump

TOOLS NEEDED

Wrench          Flathead
Screwdriver

1/2″ (13 mm) Wrench       Flathead Screwdriver

SPECIFICATIONS

Pump Type                                 Rotary – Vane
Flow                                           8 GPM (12 oz / Stroke)
Maximum Fluid Temperature    130°F / 54°C
Bung Adapter                            2″ Male
Suction Tube Length                 40″ Maximum
Inlet                                           1¼” O.D.
Outlet                                        1″ O.D. Curved Spout
Wetted Parts                               PP, PVDF, PTFE, 304SS & EPDM
Maximum Viscosity                    1,000 cps

OPERATING INSTRUCTIONS

IMPORTANT! This pump is made out of polypropylene, PVDF, PTFE, 304 stainless steel and EPDM. Use chemicals compatible with these materials and follow OSHA guidelines when using this pump, including proper grounding and protective gear as required. Unit not UL or FM approved.

  1. Rotate handle clockwise several times to prime. If unit does not prime after a few turns, pouring some fluid into pump inlet may help free pump.
  2. For siphoning, position handle straight down.
  3. To stop siphoning, rotate handle 1/4 turn (leave handle in horizontal position).
  4. After using pump, position handle straight down. Liquid will drain back into the container.
  5. If pump is removed from drum, rinse it thoroughly in a liquid that is compatible with both the pump and the fluid being pumped.
  6. Regularly check pump and suction tubes for leaks. Leaks in the suction line or in pump housing will cause inefficient pumping and loss of prime.

ASSEMBLY AND INSTALLATION

ULINE H-4377 Rotary Drum Pump ASSEMBLY AND INSTALLATION
A ULINE H-4377 Rotary Drum Pump
ASSEMBLY AND INSTALLATION B

#   DESCRIPTION             QTY.
1     Pump Body                          1
2     Rear Cover                           1
3     Front Cover                         1
4     Rotor                                   1
5     Vane                                    2
6     Spring                                  1
7     Spring Rod                           1
8     Lip Seal                                1
9     Discharge Spout                  1
10   Cap Screw                           4
11   Cap Screw                           6
12   O-Ring                                2
13   Hex Bridge                          2
14   Crank Arm                          1
15   Set Screw                             1
16   Handle                                 1
17   Handle Shaft                        1
18   Hex Nut                               1
19   Bung Adapter                       1
20   Suction Tube                        3
21   Tube Connector                   2
22   Suction Filter                        1

1. Check to see if all parts are included.
2. Screw discharge spout (9) into pump body (1) outlet using PTFE sealant tape provided.

CAUTION! Do not use pipe sealant.

3. In order to avoid leakage, use PTFE sealant tape (included) to seal three suction tubes (20) with two tube connectors (21).
4. Attach bung adapter (19) onto the top of the assembled suction tube. Screw assembled suction tube into pump body (1).
5. Insert handle shaft (17) through handle (16). Turn hex nut (18) onto handle shaft until handle rotates freely.
6. Screw assembled handle to crank arm (14). Keep handle shaft from turning. Tighten hex nut (18) against crank arm. Then insert crank arm assembly onto rotor (4), taking care to align set screw (15) to indent in rotor shaft.
7. Insert assembled pump into drum and hand tighten the fixed screw onto bung adapter (19). Be sure to set pump and assembled suction tube so that the suction tube is at the desired depth in the drum and is not blocked.

1-800-295-5510
uline.com