OPERATING INSTRUCTIONS ****

Changing Parts

Replacing Heating Element Wire
Changing parts

REMOVE PLUG FROM OUTLET BEFORE INSTALLATION

  1. Remove plastic cover from front post.
  2. Remove Teflon® tape on both the top and bottom sealing arms.
  3. Remove screw attaching heating element to post, located under plastic cap.
  4. Remove heating element.
  5. Remove rear top cover plate to expose rear post.
  6. Attach new heating element to front post with screw.
  7. Feed heating element through channel.
  8. Use flathead screwdriver to compress spring on rear post.
  9. Attach heating element to rear post.
  10. Replace top cover.
  11. Replace plastic cover on front post.
  12. Cut new Teflon® tapes in half to create four, 18 Place two on the top sealing arms and two over the bottom sealing wires.