INSTALLATION
REMOVE PLUG FROM OUTLET BEFORE INSTALLATION
- Remove the upper Teflon cloth by unscrewing and removing Fixed Plate #1. Loosen screws on fixed plate #2. Slide Teflon strip out from under Plate #2. The Heating Element is now exposed.
- Remove the Heating Element wire by unscrewing each
- Once wire is removed, peel off the old Lower Teflon Strip and attach the new strip after removing its adhesive backing.
- Connect the new Heating Element to posts and tighten screws. Do not bend or twist the Heating Element wire.
- Insert new Upper Teflon Strip under Plate #2 and tighten screws.
- Reinstall Fixed Plate #1 and tighten screws.
BLADE REPLACEMENT
- To replace the cutter blade, loosen the screws on Cutter Bracket
- Pull the Cutter Bracket back, and remove the Blade handle.
- Unscrew the Blade from the Blade Handle and insert new Blade. Tighten the Blade screw.
- Insert the Blade Handle back into its orginal position and tighten all screws on the Cutter Bracket.