tp-link Unmanaged Desktop PoE+Switch Installation Guide
- June 7, 2024
- tp-link
Table of Contents
Installation Guide
Unmanaged Desktop PoE+ Switch
Switches Explanation (Only for TL-SG1210MP)
Note: The numbers in brackets indicate the ports where the feature takes
effect. For example, when Extend(1-4) is toggled to On, the Extend mode will
be enabled for ports 1-4.
Extend
Off: Ports run at 10/100/1000 Mbps and support PoE power supply up to 100 m
away.
On: Ports run at 10 Mbps and support PoE power supply up to 250 m away.
Priority
Off: All the ports transmit data with the same priority.
On: The specific ports transmit data with a higher priority than other ports.
Recovery
Off: The PoE Auto Recovery function is disabled.
On: The switch will constantly detect the working status of a PoE-powered
device (PD).
When the switch finds that the PD works abnormally, the switch will reboot it.
Isolation
Off: Ports can transmit data with each other.
On: Specific ports cannot transmit data with other downlink ports. They can
transmit data only with the uplink ports.
LED Explanation
Power
On: Power on
Off: Power off
Link/Act; Uplink 1, Uplink 2
Green On:
Running at 1000 Mbps, but no activity.
Green Flashing:
Running at 1000 Mbps and is transmitting or receiving data.
Yellow On:
Running at 10/100 Mbps, but no activity.
Yellow Flashing:
Running at 10/100 Mbps and is transmitting or receiving data.
Off:
No device is linked to the corresponding port.
PoE Status
On: Providing PoE power
Flashing: PoE fault
Off: Not providing PoE power
PoE Max
For TL-SG1008P:
On: 57 W≤Total power supply < 64 W
Flashing: Total power supply ≥ 64 W
Off: Total power supply < 57 W
For TL-SG1210P:
On: 56 W≤Total power supply < 63 W
Flashing: Total power supply ≥ 63 W
Off: Total power supply < 56 W
For TL-SG1210MP:
On: 116 W≤Total power supply < 123 W
Flashing: Total power supply ≥ 123 W
Off: Total power supply < 116 W
Note: For simplicity, we will take TL-SG1008P for example throughout the Guide.
Connection
Note: PoE ports can also connect to non-PoE devices, but only transmit data.
Frequently Asked Questions (FAQ)
Q1. The Power LED is not lit.
The Power LED should be lit when the power system is working normally. If the
Power LED is not lit, please check as follows:
A1: Make sure the AC power cord has connected the switch with the power source
properly.
A2: Make sure the voltage of the power supply meets the requirements of the
input voltage of the switch.
A3: Make sure the power source is on.
Q2. The Link/Act LED is not lit when a device is connected to the
corresponding port.
It is recommended that you check the following items:
A1: Make sure that the cable connectors are firmly plugged into the switch and
the device.
A2: Make sure the connected device is turned on and working well.
A3: The cable must be less than 100 meters long (328 feet). If Extend Mode is
enabled, it should be less than 250 meters (820 feet).
Q3. Why is PoE/PoE+ Port not supplying power for PoE devices?
When the total power consumption of connected PoE devices exceeds the maximum,
the PoE port with a smaller port number has a higher priority. The system will
cut off power to the ports with larger port numbers to ensure supply to other
ports.
Take TL-SG1008P as an example. If ports 1, 2, and 4 are consuming 15.4 W
respectively, and an additional PoE device with 20 W is connected to port 3,
the system will cut off the power of port 4 to compensate for the overload.
Q4. What should I notice before using the PoE Auto Recovery feature?
A1: Before upgrading a connected PoE-powered device (PD), disable PoE Auto
Recovery to avoid the PD’s damage.
A2: When a PD does not send data packets to the switch for a long period in
certain scenarios (e.g. an IPC in sleep mode), disable PoE Auto Recovery to
avoid the PD repeatedly rebooting.
Environmental and Physical Specifications
Operating Temperature | 0˚C to 40˚C (32˚F to 104˚F) |
---|---|
Storage Temperature | -40˚C to 70˚C (-40˚F to 158˚F) |
Operating Humidity | 10% to 90%RH non-condensing |
Storage Humidity | 5% to 90%RH non-condensing |
Specifications
General Specifications
Standard| IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x,
IEEE 802.3af, IEEE 802.3at, IEEE 802.1p
IEEE 802.3z (Only for TL-SG1210P/TL-SG1210MP)
---|---
Protocol| CSMA/CD
Interface| For TL-SG1008P:
8 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX;
PoE Ports: Port 1-4
For TL-SG1210P:
9 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX;
1 1000 Mbps SFP port;
PoE Ports: Port 1-8
For TL-SG1210MP:
10 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX;
1 1000 Mbps SFP port (Combo);
PoE Ports: Port 1-8
Network Media (Cable)| 10BASE-T: UTP category 3, 4, 5 cable (maximum 100 m);
EIA/TIA-568 100 Ω STP (maximum 100 m)
100BASE-TX: UTP category 5, 5e cable (maximum 100 m);
EIA/TIA-568 100 Ω STP (maximum 100 m)
1000BASE-T: UTP category 5e cable or above (maximum 100 m);
EIA/TIA-568 100 Ω STP (maximum 100 m)
1000BASE-SX/LX/LX10/BX10: MMF, SMF (Only for
TL-SG1210P/TL-SG1210MP)
Switching Capacity| TL-SG1008P: 16 Gbps
TL-SG1210P/TL-SG1210MP: 20 Gbps
MAC Address Table| 4K
Transfer Method| Store-and-Forward
MAC Address Learning| Automatically learning, automatically aging
Power Supply| Input: 100-240 VAC, 50/60 Hz
Output: 53.5 V DC/2.43 A (For TL-SG1210MP)
53.5 V DC/1.31 A (For TL-SG1008P/TL-SG1210P)
PoE Budget| TL-SG1008P: 64 W (up to 30 W for each PoE port)
TL-SG1210P: 63 W (up to 30 W for each PoE port)
TL-SG1210MP: 123 W (up to 30 W for each PoE port)
Wall Mountable| Yes
Distance Between
Mounting Holes| TL-SG1008P: 105 mm
TL-SG1210P/TL-SG1210MP: 150 mm
PoE Disclaimer
The speed of the ports in extends mode will downgrade to 10 Mbps. The actual
transmission distance may vary due to the power consumption of PoE-powered
devices or the cable quality and type.
PoE budget calculations are based on laboratory testing. The actual PoE power
budget is not guaranteed and will vary as a result of client limitations and
environmental factors.
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of directives 2014/30/EU,
2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-
link.com/en/support/ce/
UKCA Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential
requirements and other relevant provisions of the Electromagnetic
Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations
2016.
The original UK Declaration of Conformity may be found at https://www.tp-
link.com/support/ukca
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
For technical support and other information, please visit https://www.tp-
link.com/support, or simply scan the QR code.
If you have any suggestions or needs on the product guides, welcome to email
techwriter@tp-link.com.cn.
http://www.tp-link.com/support
Safety Information
- Keep the device away from water, fire, humidity or hot environments.
- Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
- Do not use a damaged charger or USB cable to charge the device.
- Do not use any other chargers other than those recommended.
- The adapter shall be installed near the equipment and shall be easily accessible.
- Use only power supplies which are provided by the manufacturer and in the original packing of this product. If you have any questions, please don’t hesitate to contact us.