Honeywell Local Air Conditioner User Manual
- June 7, 2024
- Honeywell
Table of Contents
- SAFETY
- SMART PORTABLE AIR CONDITIONER WITH WIFI CONNECTIVITY & VOICE CONTROL
- USER TIPS
- PARTS DESCRIPTION
- INSTALLATION
- USE AND OPERATION
- CLEANING AND MAINTENANCE
- WATER CONDENSATION DRAINAGE
- TROUBLESHOOTING GUIDE
- ERROR CODE GUIDE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Honeywell Local Air Conditioner User Manual
www.honeywellaircomfort.com
info@honeywellaircomfort.com
SAFETY
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND KEEP FOR FUTURE REFERENCE.
IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND
ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH
VERSION SHALL PREVAIL.
The refrigerant used in the mobile air conditioners is the environmentally friendly hydrocarbon R290. This refrigerant is odorless. Compared to the alternative refrigerant, the R290 is an ozone-free refrigerant and its influence is very low.
The drawings provided in this manual may not be the same as the physical objects. Please refer to the physical objects. Please read the instructions before use and repair.
WARNING:
-
DO NOT use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
-
The appliance shall be stored in a room without continuously operating ignition sources like open flames, an operating gas appliance or an operating electric heater.
-
Do not pierce or burn the unit.
-
Be aware that refrigerants may not contain an odor.
-
Appliance shall be installed, operated and stored in a room with a floor area larger than 15 m².
-
Keep any required ventilation openings clear of obstruction.
-
Servicing shall be performed only as recommended by the manufacturer.
-
This appliance should be used in a room that allows for good ventilation between the unit and any walls/furniture or other objects. The room size should correspond to the room area as specified for operation by the manufacturer and the appliance should be well kept to prevent mechanical damage.
-
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
-
Only persons authorized by an accredited agency certifying their competence to handle refrigerants in compliance with sector legislation should work on refrigerant circuits.
-
Maintenance and repairs requiring the assistance of other qualified personnel must be carried out under the supervision of specialists in the use of inflammable refrigerants.
-
All working procedure that affects safety means shall only be carried by competent persons.
-
This appliance can not be used by children, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
Follow local grid interconnection rules while installing the air conditioning and ensure that it is properly grounded. If you have any question on electrical installation, follow the instructions of the manufacturer, and if necessary, ask a professional electrician to install it.
-
Place the machine in a flat and dry place and keep a distance of above 50cm between the machine and the surrounding objects or walls.
-
After the air conditioning is installed, ensure that the power plug is intact and firmly plugged into the power outlet, and place the power cord orderly to prevent someone from being tripped or pulling out the plug.
-
When drainage pipes are installed, ensure that the drainage pipes are properly connected, and are not distorted or bended. While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently to avoid damaging wind-guide strips.
-
The appliance should be transported upright or on its side.
-
DO NOT use the device in the following cases:
– in a room with continuously operating sources of ignition (eg. open flames, an operating gas appliance or an operating electrical heaters.
– In areas where gasoline, Sulphur, oil, paint or other flammable goods are stored.
– In an area where the water can be projected. -
DO NOT touch the plug or the device with wet hands.
-
Flammable substances or pressurized containers (eg. aerosol cans) should be kept a minimum of 50cms away.
-
Do not turn on the appliance for at least one hour before starting it.
-
DO NOT operate the unit with a damaged plug or loose wall outlet. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
-
DO NOT cover the air intake and exhaust when in use.
-
DO NOT place objects, especially heavy or hot objects, on top of unit. DO NOT sit on the unit.
-
DO NOT use the appliance if it is damaged.
-
DO NOT modify this appliance in any way to avoid danger.
-
DO NOT pull or carry the appliance by the power cord.
-
DO NOT pinch the power cord in the door and DO NOT pull it along edges or sharp corners.
-
Do not pierce or burn the refrigerants.
-
A warning to keep ventilation openings clear of obstruction.
-
Always turn off and unplug the unit when cleaning or servicing. Unplug the unit when stored or not in use.
-
Refrigerant gas may be odorless.
-
Stagnation of possible leaks of refrigerant gas in unventilated rooms could lead to fire or an explosion hazard should the refrigerant come in contact with electric heaters, stoves or other sources of ignition.
-
Use care when storing the appliance to prevent mechanical faults.
-
Use only implements recommended by the manufacturer for defrosting or cleaning.
-
DO NOT use an extension cord with this unit.
-
Never insert your fingers or rods into the air outlet. Take special care to warn children of these dangers.
-
DO NOT operate your air conditioner in a wet room such as a bathroom or laundry room.
-
The manufacturer is not liable for injury caused to persons or property damage due to non-compliance with maintenance instructions and improper use of the appliance.
-
Basic safety precautions should always be followed when using electrical appliances.
-
Electrical equipment and installations regulated by national legislation must be followed.
-
Only use the installation kit provided to install this unit. DO NOT attempt to extend the hose or install this unit using other methods other than that shown in this manual. Improper installation will void any existing warranties.
-
If service is needed contact an authorized service agent. Repairs must only be undertaken by authorized service centers of the manufacturer. Failure to comply may be dangerous.
-
Transport of equipment containing flammable refrigerants Compliance with the transport regulations.
-
Marking of equipment using signs Compliance with local regulations.
-
Disposal of equipment using flammable refrigerants Compliance with national regulations.
-
The storage of equipment should be in accordance with the manufacturer’s instructions.
-
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Repair must be performed based on the recommendations from the manufacturer. Maintenance and repair that requires the assistance of other qualified personnel must be performed under the supervision of specialists in the use of flammable refrigerants.
SMART PORTABLE AIR CONDITIONER WITH WIFI CONNECTIVITY & VOICE CONTROL
For Models: HJ12CESV/HJ14CESV/HJ16CESV Smart Portable Air Conditioner with WiFi Connectivity**
The Smart Portable Air Conditioner has added features to allow you to operate the Air Conditioner remotely using a smart device, and to use voice commands through an an Amazon Echo / google home device, to control the unit.
Set up the Honeywell Air Comfort App on your smart phone or tablet to connect the Honeywell Smart Portable Air Conditioner for WiFi and Voice control (only available for Smart Portable Air Conditioner models).
1. Download the Honeywell Air Comfort App User Manual from the below link:
HJSmartPACAppManual [PDF]
2. Download the Honeywell Air Comfort App on your smartphone or tablet.
SEARCH “HONEYWELL AIR COMFORT”
IMPORTANT: A 2.4 GHz Wi-Fi network is required for proper connection and operation between the Portable Air Conditioner and the App.
NOTE: The Smart Portable Air Conditioner does not have to be connected to the Honeywell Air Comfort App to function. You can still operate manually using the unit’s control panel.
THANK YOU
Congratulations on your purchase of this Honeywell Local Air Conditioner.
Regarding the information pertaining to the installation, handling, servicing,
cleaning and disposal of the appliance, please refer to the below paragraph of
the manual.
USER TIPS
Local Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is dehumidified and cooled while a flexible hose sends heat outside. The Local Air Conditioner includes a window venting kit. No permanent installation is needed. The unit is easy to move from room to room and offers a truly flexible air conditioning solution. Auto Evaporation System – The unit automatically evaporates the condensate through the hose. There is no need to empty the drainage tank except in humid conditions. Read and follow the instructions carefully. To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation.
Important: Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize. Air outlet automatically opens when the unit is turned on, and automatically closes when the unit is turned off. Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
- Follow installation instructions to set up the unit.
- Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
PARTS DESCRIPTION
- Control Panel
- Air Outlet
- Handle
- Casters
- Remote Control
- Hose Connector
- Cord Winder
- Upper Dust Filter
- Upper Rubber Drain Plug (Dehumidifying Mode)
- Lower Dust Filter
- Drain Tube (For Continuous Drain)
- Drain Plug Cap
- Lower Rubber Drain Plug (Air Conditioning Mode)
- Power Supply Cord
INSTALLATION
It is important that the installation instructions below are followed for successful installation of this Local Air Conditioner. Please call Customer Support if you have any difficulties or queries regarding these installation procedures.
Installation Kit:
- Window Bracket Kit (1 Set)
- Window Bracket Panel Adapter (1 Piece)
- Exhaust Hose Connector (1 Piece)
- Exhaust Hose (1 Piece)
- Drain Tube (1 Piece)
- Butterfly Screws (1 Piece)
Installation Steps:
1. Exhaust Hose Connector, Exhaust Hose and window bracket panel adapter are pre-assembled inside the package.
Hose: Length: 10.23” to 47” (26cm to 120cm)
Window Bracket Kit:
This window kit is designed to fit most standard sliding windows. If your window is outside of the size parameters as outlined above, the window bracket can be cut shorter to fit by bringing it to a nearby hardware store.
Note: After setting the window bracket to the size of your window, please remove it from the window and follow the instructions below.
2. Connect the hose to the rear exhaust outlet on the back of the unit. Slide-in the hose connector then rotate clockwise until it is locked in place.
3. Connect the window bracket to the window bracket panel adapter. Ensure that all connections are tight and installed properly.
4. Connect the window bracket to the window.
5. The Local Air Conditioner is now ready to use. EN 5
IMPORTANT: Do not replace or lengthen the hose as this could cause the
unit to malfunction. The length of the hose is scientifically determined by
the specifications and airflow of the air conditioner. Extending the hose
beyond the specified dimensions can cause heat to collect or flow back into
the air conditioner causing the unit to malfunction.
WARNING: Any warranties included with this product will be voided if an extra extension hose is added to the originally provided installation kit or if the installation is performed differently than the manufacturer’s instructions, without proper consultation. Please contact Customer Support for help with installation procedures if needed.
- The supplied hose has a diameter of 5.9″ (15 cm) and can be extended from 10.23” to 47” (26cm to 120cm).
- Do not bend (to the extent shown above) the hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off.
- Make sure the back of the unit is at least 20″ (50 cm) away from the wall. Do not place the unit in front of curtains or drapes as this could obstruct the airflow.
USE AND OPERATION
CONTROL PANEL
- Indicator Lights
- Power Control
- Swing Control
- Fan Speed Control
- Timer / Temperature Set Controls
- Sleep Mode
- Mode Control
- Timer Control
- ^Wi-Fi Connectivity and Voice Activated Control
^THIS IS ONLY FOR MODEL HJ12CESV / HJ14CESV /HJ16CESV WITH WIFI SMART
FEATURES
NOTE: For detailed instructions to set up your Portable Air Conditioner for
connected operation from your smart phone or tablet, separate user manual can
be downloaded at:**
FUNCTION BUTTONS
POWER CONTROL
Press to turn ON/OFF the unit. The air vent will automatically swing open when
the unit is turned ON and automatically close when the unit is turned OFF.
RESTART DELAY
If the unit turns OFF while operating in COOL mode, there will be an approx.
3-minute delay to restart the air conditioner in COOL mode. This is a safety
feature and added to help protect and extend the life of the compressor. After
3 minutes, you will be able to turn ON the unit as usual.
FAN SPEED CONTROL
3 settings: High, Medium, and Low.
Note: Fan Speed cannot be adjusted in Sleep Mode and Dehumidifying Mode.
MODE CONTROL
Settings: Air Conditioning, Dehumidifying, Fan, Heating*. The corresponding
indicator light will illuminate to indicate the current mode setting.
-
Air Conditioning Mode (COOL)
Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 61°F – 88°F (16°C -31°C). -
Dehumidifying Mode (DRY)
Air is dehumidified as it passes through the unit, without being in full cooling mode. The fan speed is preset as LOW speed and can NOT be adjusted.
Note: If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose. Continuous drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode).
IMPORTANT: The Dehumidifier Mode is used to support moisture reduction but should not be expected to dehumidify to the same degree as a standard dehumidifier only appliance. The built-in dehumidifier automatically adjusts dehumidification based on ambient room temperatures. It is not possible to adjust to a desired humidity percentage. The front display only shows the current and desired temperatures. It does not show humidity levels. -
Fan Mode
For air circulation without air conditioner cooling. -
Heating Mode*
When heating mode is selected the indicator light will shine. Heating is activated only when the ambient temperature is below 77°F (25°C). In this mode, the desired temperature can be set between 61°F – 88°F (16°C -31°C).
Note: The exhaust hoses must vent outside the room when using heating mode.
IMPORTANT: The Heat pump draws moisture from the air which then condenses into the internal water tank. The unit will pause operation when the tank is full and will restart when the tank has been emptied. It is recommended to use the Heating Mode in a room with 50% humidity or lower. Avoid operating moisture-producing products or appliances such as a humidifier or a kettle when using the unit in Heating Mode. See the “Draining Water Condensation in Heat Mode” section for more information on draining the water tank.
TIMER / TEMPERATURE SET CONTROLS
The – and + buttons can be used to adjust and set your desired
temperature in Cooling or Heating modes. They can also be used to set the
Timer (see “Timer Control” below).
Applicable for models with Heating feature only.
SLEEP MODE
Sleep Mode is for energy-saving comfort during the night. When Sleep Mode
**is ON in Air Conditioning Cooling Mode, the fan will automatically stay on
LOW Speed and the set temperature will increase by 1°F (1°C) on the first
hour. It will increase another 1°F (1°C) on the second hour, and remain at
this temperature for the rest of the night, until Sleep Mode is deactivated.
Note:* The control panel lights will turn OFF after 10 seconds and light
up again when any button is pressed. When Sleep Mode is ON in Heating Mode,
the fan will automatically stay on LOW Speed and the set temperature will
decrease by 1°F (1°C) on the first hour. It will decrease another 1°F (1°C) on
the second hour, and remain at this temperature for the rest of the night,
until Sleep Mode is deactivated.
TIMER CONTROL
While the unit is turned on, press the timer button then press the – or
+ to select the number of hours you would like the unit to continue to
run. The unit will turn on/off automatically.
AUTO TURN OFF:
While unit is running, press the – or + button to select the number of
hours you want the unit to run in air conditioning mode.
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light on), then press
the – or + button to select the number of hours until you want the
unit to automatically start running.
SWING CONTROL
Press ****to activate automatic oscillation of louvers. Press again to stop
swing when louvers reached a desired angle.
WATER FULL LIGHT
Condensation may accumulate in the unit. If the internal tank becomes full,
the Water Full Light ****will illuminate and unit will beep 5 times for 5
seconds. The unit will not operate until the unit has been drained (refer to
Water Condensation Drainage).
WI-FI MODE^
When the Smart Portable Air Conditioner is connected to the wifi function, the
****indicator light will be illuminated.
^THIS IS ONLY FOR MODEL HJ12CESV / HJ14CESV / HJ16CESV WITH WI-FI SMART FEATURES**
ADDITIONAL FEATURES:
AUTOMATIC DEFROST FEATURE
Sometimes when the unit is operating in cooling mode in lower room
temperatures (e.g. lower than 60°F), the internal cooling coils may become too
cold and sometimes frost may develop on the cooling coils. When this happens,
the unit will automatically pause operation and defrost the cooling coils to
protect the unit. The air conditioner will restart automatically when the
system has defrosted and returns to standard operational temperatures.
*Applicable for models with Heating feature only.
REMOTE CONTROL
All key functions can be accessed from the remote control.
Note:
- Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with + and – pointing in the proper direction according to the polarity markings.
Caution:
- Use only two AAA or IEC R03 1.5V batteries.
- Remove the batteries if the remote control is not in use for a month or longer.
- All batteries should be replaced at the same time, do not mix with old batteries.
- Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
- Properly dispose of used batteries.
This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment info an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
*Applicable for models with Heating feature only.
CLEANING AND MAINTENANCE
Appliance Maintenance:
- Turn off the appliance before disconnecting the power supply.
- Only clean the appliance with a soft dry cloth.
Dust Filter Maintenance:
The dust filter is to be cleaned every two weeks to maintain air cooling
efficiency. Please follow the below instructions for cleaning the dust
filters:
-
Switch off and unplug the Local Air Conditioner from the electrical outlet.
-
Remove the Upper Filter/ Grill, unscrew the Lower Filter/ Grill and carefully remove.
-
Gently wash using water and/ or diluted liquid dishwashing detergent. Rinse thoroughly and gently shake excess water from the filters. Make sure the filters are dry before reinstalling.
Note: You may use a vacuum cleaner to remove dust. -
Replace the Upper Grill onto the unit, and reinstall the Lower Grill with the screw.
WARNING: DO NOT power or operate the Local Air Conditioner when cleaning or when the Dust Filter is removed from the unit, or if there is a loose- fitting Dust Filter. DO NOT attempt to handle or touch any of the parts or wiring inside the Rear Grill after the Dust Filter has been removed from the unit. Doing so can cause serious injury or electrical shock.
End of Season Storage and Maintenance:
If the appliance will not be used for a long time, follow these steps:
-
Be sure to drain the left-over water condensation. Remove the lower drain plug and use a drain pan to collect the water (make sure to replace the deain plug cap when finished).
-
To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
-
Turn off and unplug the Local Air Conditioner from the power supply.
-
Remove the dust filter and clean with water. Dry the dust filter and then reinstall.
-
Disconnecting the Window Installation Kit:
• Remove the Hose from the unit by rotating anti-clockwise then pulling away.
• Remove the Window Bracket, Window Bracket Panel Adapter and Hose Connector.
• It is recommended to store the Window Kit parts in a bag together with the Remote Control, Drain Tube and placing them together with the Local Air Conditioner unit.
• If needed, you can clean the Window Kit with a damp cloth and water before storing. Make sure all parts of the Window Kit are dry before storage. -
Cover the Local Air Conditioner with a cloth/ plastic bag before storage, to protect from dust and scratches collecting on the surface of the unit.
-
It is recommended to coil the power cord before storing to ensure the cord is protected from bents and creases.
-
Store the Local Air Conditioner in a cool, dry place, away from direct sunlight.
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (the WATER FULL indicator illuminates with a red light). This indicates that the water condensation needs to be drained using the following procedures:
Manual Draining in Cooling, Dehumidifying Modes
Water may need to be drained in high humidity areas.
- Unplug the unit from power source.
- Place a drain pan under the lower rubber drain plug. See diagram.
- Remove the drain plug cap.
- Water will drain out and collect in the shallow pan.
- After the water is drained, replace the drain plug cap.
- You can now turn on the unit.
Continuous Draining in Dehumidifier Mode
While using the unit in dehumidifier mode, continuous drainage is recommended.
- Unplug the unit from power source.
- Remove the upper drain plug cap. Some residual water may spill so please have a pan to collect the water.
- Connect the drain tube to the upper drain plug. See diagram.
- The water can be continuously drained through the drain tube into a floor drain or bucket.
- Replace the drain plug cap.
- You can now turn on the unit.
IMPORTANT: It is NOT recommended to connect the drain hose for continuous
drainage while the unit is switched ON in air conditioning cooling mode. Doing
so will reduce the cooling efficiency of the Local Air Conditioner. Only drain
the water condensation when the unit is switched off. Continuous drainage is
only suitable when the unit is set up in Dehumidifier mode.
The water cannot be drained using the continuous drain option in heating
mode. In Heating mode, the internal water tank collects condensation faster
and may require more frequent emptying of the tank in more humid rooms. It is
recommended to use the heating mode in a room with 50 % humidity or lower.
Avoid operating moisture-creating products or appliances such as a humidifier
or a kettle when using the unit in heating mode.
Applicable for models with Heating feature only.
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call customer support. Unplug and disconnect the appliance from the power source before attempting to troubleshoot.
ERROR CODE GUIDE
Made in China
© 2021 JMATEK Limited. All rights reserved.
The Honeywell Trademark is used under license from Honeywell International
Inc. Honeywell International Inc.makes no representations or warranties with
respect to this product. This product is manufactured by Airtek Int’l Corp.
Ltd. (subsidiary of JMATEK Ltd.).
JMATEK UK Limited
Keizersgracht 62 1015 CS Amsterdam Netherlands
Tel: +31 20 5207422
Support.eu@jmatek.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>