ULINE Heavy Duty Stationary Pedestal Fan Instructions
- June 7, 2024
- ULINE
Table of Contents
H-6438, H-6439 HEAVY DUTY STATIONARY PEDESTAL FAN
1-800-295-5510
TOOLS NEEDED
Flathead Screwdriver Pliers Wire Cutter
PARTS
3-Port Electrical Chain Switch x 1 Rope Pull Chain Extension x 1
Knurled Screw x 1 Wire Nut x 1
INSTRUCTIONS
REMOVAL OF BAD CHAIN SWITCH
- Unplug fan from power source.
- Remove electrical box cover on motor with a 1/4″ nut driver or flathead screwdriver.
- Remove chain switch nut with fingers or pliers by softly turning. Save the knurled screw knob, as it may be used during installation of new switch.
- Using a wire cutter, cut the existing wires connected to the bad chain switch close to the switch. This ensures the wires are still long enough to connect the new switch.
CONNECTING NEW CHAIN SWITCH
1. Strip about 1/4″ of insulation off of wire ends for a clean connection to
new switch.
2. Connect white wire from the motor and white wire from power cord together
with a wire nut. If the existing motor already has white wires connected, skip
this step and leave white wires connected. (See Figure 1)
3. Push orange wire from motor into port number one (high speed). It should
lock into place.
4. Push blue wire from motor into port number two (low speed). It should lock
into place.
5. Push black wire from power cord to port “L” (line). It should lock into
place.
6. Reassemble fan by reversing steps #1 through #4 of the removal
instructions.
NOTE: Lines to ports one and two are interchangeable. Ports one and two control speeds and the above instructions explain how to wire the replacement switch to factory specifications, but it can be changed per user’s desire.
0521 IH-6438