ULINE H-6555 Ceiling Fan Installation Guide

June 7, 2024
ULINE

Ceiling Fan H-6555

ceiling fan

H-5655 CEILING FAN
1-800-295-5510
uline.com

TOOLS NEEDED

parts tools
PARTS

ceiling parts

REPLACEMENT PARTS LIST

#

|

DESCRIPTION

---|---

1

|

18″ Downrod with Rubber Support

2

|

Lower Canopy

3

|

J Hook

4

|

Upper Canopy

5

|

Blade

6

|

Capacitor

7

|

Motor Housing With Yoke

NOTE: After opening carton, look for concealed damage. If concealed damage is found, immediately file claim with carrier.

SAFETY

WARNING! Disconnect power supply before wiring connections are made to prevent possible electric shock or damage to equipment.
WARNING! Do not operate any fan with a damaged cord or plug. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
WARNING! Read and follow instructions carefully. Failure to comply with instructions could result in fire, electric shock, injury to persons and/or damage to equipment.
WARNING! Do not use an extension cord with this fan.
CAUTION! Follow all maintenance procedures enclosed.

DANGER! Failure to properly ground unit could result in severe electrical shock or death.
1. All wiring should conform to the National Electrical Code ANSI/NFPA 70-1999 (NEC) in the United States, CEC and local regulations.
2. Do not mount in an area that will allow the ceiling fan to come in contact with moisture.
3. Make certain the entire installation is grounded as a precaution against possible electrical shock.
4. Do not exceed maximum amperage rating of the ceiling fan, as overloading can result in damage to ceiling fan.
5. When wiring an electrical appliance or device, follow all electrical and safety codes, as well as the most recent NEC, CEC and local regulations and the Occupational Safety and Health Act (OSHA).
6. Suitable for use with solid state speed control.
0521 IH-5655

INSTALLATION

This model is manufactured with a cord and a molded three prong electrical plug, which can be installed directly into an electrical outlet.
NOTE: For installation to open web steel joist, use the threaded J hook as supplied. For wood joist construction, use J hook with lag threads (not included). For attachment in concrete, drill concrete anchors into the concrete, as applicable to NEC, CEC and local regulation.
WARNING! To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

  1. Prior to installation, ensure all pre-installed set screws, cotter pins and locknuts are tight and secure.
  2. Slide lower canopy (2) down to the rubber gasket to create a tight seal. Tighten set screw.
  3. Wind one nut down to bottom of J hook (3) towards the curve. Add a lock washer and then flat washer on top of the nut.

WARNING! Make certain crimps on safety loop are secure (See Figure 1). Make certain safety cable is attached properly to hook or structural member. Failure to comply with instructions could result in personal injury and/or property damage.

safety fan

4. Drill a 5/32″ pilot hole for safety hook (See Figure 1) within a 12″ radius of J hook (3) for fan. Wind one nut down to bottom of safety hook towards the loop. Add a lock washer and slide safety hook through pilot hole. Slide lock washer on top side of the safety hook and add nut. Tighten so lock washers on top and bottom of the structure are secure.

J Hook Support Support Bracket

5. Drill a 1/2″ pilot hole for J hook. Put J hook (3) through pilot hole in joist. Add flat washer and then lock washer and nut. Do not tighten completely until fan is put in place on J hook.
NOTE: A lubricant should not be used on the single mounting screw. Pilot hole should be drilled no larger than the minor diameter of the mounting screw threaded. At least 1/” (38mm) of the threaded part of the mounting screw should be secured into a structural joist to provide secure mounting.
IMPORTANT! If a shorter down rod is required, read steps on page 3.
6. Loosen set screw on upper canopy (4) on fan down rod (1) and lower the canopy to make room to place rubber grommet onto mounting J hook.
7. Tighten top nut on J hook to raise fan into proper installation position.
WARNING! When installed properly, the blades will hang 10′ above the floor level. It is critical that the J hook and nut adjustment are done so that the blades will be a minimum 12″ from the ceiling. If your ceiling is less than 12′, then the hook and down rod must be recessed into the ceiling so that the blades are mounted 10′ above the floor level to meet OSHA standards.
8. Raise upper canopy (4) up the down rod to cover hook. Leave 1/8″ gap between upper canopy (4) and hanging surface so down rod does not move off center, which could make fan wobble or vibrate and transmit motor noise to ceiling surface. Tighten set screw on upper canopy (4).
9. Attach blades (5) to motor housing (7) with blade bolts already installed in motor housing. The blade should be positioned below the blade arm bracket when attaching to the motor to get proper air flow and direction. (See Figure 2)

get proper

INSTALLATION CONTINUED

CHANGING TO SHORTER DOWNROD:

  1. Loosen and remove bolt, cotter pin and nut on the fan downrod support bracket. (See Figure 1)

  2. Slide upper canopy (4) and lower canopy (2) off of the downrod (1) and over the wires and safety cable.

  3. Loosen set screw and remove cotter pin at the motor and slide the downrod (1) over the wires and safety cable. (See Figure 3)
    cotter pin

  4. Take the shorter downrod and start to reverse steps three to one.

  5. Slide the shorter downrod over the wire and safety cable and insert into yoke.

  6. Insert bolt through the yoke and downrod, making certain you do not damage the wires. Once the bolt is in place, re-insert the cotter pin and bend the longer side backwards so it will not slide out.

  7. Tighten the set screws to 10 foot/lbs. of torque.

  8. Slide the lower canopy (2) over the wires, safety cable and downrod (1) until it sits on top of the yoke, and tighten the set screw.

  9. Slide the upper canopy (4) over the wires, safety cable and downrod, and do not tighten the set screw.

  10. Attach rubber grommet and support bracket to the top of the downrod using bolt, cotter pin and nut. Make certain you do not damage the wires inside the downrod. Tighten the nut to 10 foot/lbs. of torque, re-insert the split pin and bend the longer side backwards so the pin will not slide out.

  11. Return to the installation instructions.
    NOTE: The shorter downrod, when installed properly, is a minimum 10′ above the floor level. It is critical that the J hook and nut adjustment are done so that the blades will be a minimum 12″ from the ceiling. If your ceiling is less than 12′, then the hook and downrod must be recessed into the ceiling so that the blades are mounted 10′ above the floor level to meet OSHA standards.

MAINTENANCE

DANGER! Always disconnect the power supply before servicing the ceiling fan or working with the unit for any reason.
WARNING: Parts replacement and troubleshooting should be performed only by qualified personnel.
WARNING: Do not place fingers or objects in the ceiling fan while motor is connected to the power source.

WARNING: Do not attach foreign objects to the blades of the ceiling fan.
WARNING: Do not use gasoline, benzene, thinner, harsh cleaners, etc., which are dangerous and will damage the ceiling fan.
CAUTION! If you see noticeable vibration, wobbling or wear, the fan should be removed from service and repaired or replaced by a qualified maintenance technician or electrician.

TROUBLESHOOTING

DANGER! Always disconnect the power supply before servicing the ceiling fan or working with the unit for any reason.

WARNING: Parts replacement and troubleshooting should be performed only by qualified personnel.

TROUBLESHOOTING

OPERATING ISSUE Fan will not start. Fan is too fast/slow. Fan makes noise.
Fan wobbles.

OPERATING ISSUE

|

RECOMMENDATIONS

---|---

Fan will not start.

|

a) Check fuses and circuit breakers.
b) Check wire connections to fan.
c) Check wiring connection in lower canopy.
d) Check voltage at fan connection.

Fan is too fast/slow.

|

a) Check voltage at fan connection.
b) Blades must be attached to motor to reduce the speed.
c) Adjust the trim set screw in fan wall control if using optional wall control.  If minimum setting is too low the fan may shut off with voltage fluctuations.  Increase minimum.

Fan makes noise.

|

a) Check motor case to make certain all visible screws are snug.
b) Check to make certain that all blade bracket screws are tight.
c) Check for labels or wire nuts that could be rubbing.
d) All ceiling fans may have a slight motor noise known as the “60 cycle hum” when  used with solid state infinite speed controls, especially on lower speeds. This hum  will not affect the fan performance.
e) Make certain upper canopy is at least 1/8″ from ceiling.
f) Allow a 30 day break-in period, which normally eliminates any residual noise other  than a), b), c), d) or e).

Fan wobbles.

|

a) Check that all blade brackets are screwed firmly to motor case.
b) Check distance from tip of blades to ceiling. If blades get bent during installation,  you must re-adjust them so that all blades travel on same plane. Gently bend up  or down until all distances are the same.
c) Make certain upper canopy is 1/8″ from ceiling.
d) Make certain that hanging hooks are secured tightly to ceiling.
e) Run fan without blade. If motor does not wobble, then motor is not defective, but the blades may be bent.