ACURITE 01097 Deluxe Wireless Weather Center Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
DESIGNED TO WORK FOR YOU
Wireless Weather Center
with aromatic pressure charting
ITM./ART.433981
Instruction Manual
B.
Wireless Sensor
A. Main Unit
Package Contents:
- Main Unit [Alwith stand
- Wireless Sensor [Bl
- Instruction Manual
Thank You for purchasing this ACURITE® product. Please read this manual in
it’s entirety to fully enjoy the benefits and features of this product. Please
keep this manual for future reference.
NOTE: A clear film is applied to the LCD at the factory that must be
removed prior to using this product. Locate the clear tab and simply peel to
remove.
OVERVIEW OF FEATURES
SECTION 2 • SETUP
Battery Choice & Temperature Range
Extended periods of cold temperatures below -4°F / -20°C I can cause alkaline
batteries to function improperly. This will cause the outdoor wireless sensor
to stop transmitting temperature readings. Use lithium batteries in these low-
temperature conditions to ensure continued operation for wireless sensors
placed outdoors.
NOTE: Rechargeable batteries are not recommended due to higher operating
voltages.
Install Batteries
A. Wireless Sensor
Remove the battery compartment cover. Install 2 fresh “AA” batteries as shown
here.
B. Main Unit
Remove the battery compartment cover and install 2 fresh “AA” batteries as
shown here.
A/8/C Wireless Selection
To allow for more than one weather station and wireless sensor network to be
used in close proximity, the main unit, and the wireless sensor have a small
switch labeled “A B C” within the battery compartments. This switch selects
one of 3 wireless modes to use, and both switches MUST be set in matching
positions (either A, B, or C) for wireless communication to take place
successfully.
About the Self Setting Clock
Your new wireless thermometer is equipped with Intelli-Time® technology which
is pre-programmed with the correct time and date. Intelli-Time® technology
instructs the clock to self-set itself once batteries are installed. All you
need to do is select your Time Zone and Daylight Saving Time preferences.
The clock will automatically set itself and change automatically for Daylight
Saving Time.
Main Unit: Basic Setup
Press and hold the “SET” button for 3 seconds to enter into SET MODE. Once in
set mode, the preference you are currently setting will blink on the display.
To adjust the currently selected (flashing) preference item, press the or
buttons (press and HOLD to fast adjust).
To save your adjustments, press the “SET” button again to move on to adjusting
the next preference. The preference set order is as follows:
TIME ZONE ( PST MST CST EST AST HAST AKST)
DST(Daylight Saving Time ON OR OFF)
CLOCK HOUR
CLOCK MINUTE
CALENDAR DATE
CALENDAR MONTH
CALENDAR YEAR
TEMPERATURE SCALE (°F or °C)
BAROMETRIC PRESSURE SCALE (in Hg or hPa)
You will automatically exit SET MODE if no buttons are depressed for 30
seconds. You may enter basic setup mode again at any time by pressing the
“SET” button.
Basic Setup is Now Complete
The wireless sensor will soon send a signal to the main unit and the two units
will be synchronized. It may take a few minutes for synchronization to be
complete. If both or one of the units appears to be functioning improperly,
refer to the troubleshooting section in this manual.
SECTION 3 • PLACEMENT
Now that setup is complete, you must choose a location to place the wireless
sensor and the main unit. The wireless sensor MUST be placed less than 330
feet (100 meters] away from the main unit.
This wireless thermometer uses radiofrequency for communication, which is
susceptible to interference from other electronic devices and large metallic
items or thick walls. Always place both units at least 3 feet 1.91 ml away
from appliances ITV, microwave, radios, etc. I or objects that may interfere
with the wireless communication I large metal surfaces, thick stone walls,
etc.
Placement of Main Unit
Place the main unit in a dry area free of dirt and dust. To help ensure an
accurate indoor temperature measurement, be sure to place the main unit out of
direct sunlight, and away from any heat sources or vents in your home. There
are 2 placement options for the main unit. You may hang the main unit on a
wall using the integrated hang hole. Alternatively, you may place the main
unit on a tabletop or other flat surface using the included detachable
tabletop display stand.
Placement of Sensor
The wireless sensor MUST BE PLACED OUTDOORS to observe outdoor temperatures.
The wireless sensor must be placed less than 330 feet (100 ml from the main
unit. The wireless sensor is water-resistant and is designed for general
outdoor use. However, to extend the life of the product, place the wireless
sensor in an area protected from direct weather elements. To ensure an
accurate outdoor temperature measurement, be sure the wireless sensor is
placed out of direct sunlight and away from any heat sources.
There are 2 placement options for the wireless sensor. You may hang it on a
wall using one of the two integrated hang holes, or use string (not included]
to hang it from a suitable location like a well-covered tree branch.
SECTION 4 • OPERATION
After the main unit and the wireless sensor are both powered on and wireless synchronized, no further input is required. This section outlines some of the main features of this weather station.
A.14 Day Learning Mode
This weather station has a patented “fourteen-day learning mode” calibration
process. During this learning mode, the weather station will make altitude
calculations that may affect the accuracy of the forecast. Once the 14-day
learning mode process is complete, the learning mode icon will disappear and
the weather forecast should be ready for superior operation.
B . Forecast Icon
This feature gives you the predicted weather forecast for the next 12 to 24
hours based on an advanced algorithm that includes barometric pressure and
temperature. This weather station will provide the most accurate forecast that
a single station weather instrument can provide.
C. Barometric Pressure: Current and History
This weather station has a pressure graph that tracks and displays the barometric pressure 12 hours ago as well as the current barometric pressure. Additionally, the graph will automatically display the “FALLING”, “STEADY” or “RISING” icon and a curve to represent the rate of change over the previous 12 hour time period.
D. Wireless Signal Reception icons
The main unit has a signal reception icon near the outdoor temperature display
area. If there are a low number of “bars” present, you may experience no
temperature display ( .. –” I or inaccuracy. In either case, you may need to
relocate one or both of the units. If most or all 4 of the bars are present,
wireless reception is good and no action is required.
Troubleshooting
Problem | Possible Solution |
---|
Bad Wireless Sensor Reception
no bars| Relocate the main unit and/or the wireless sensor. Both units must be
within 330 feet [100 ml from each other. Make sure both units are placed at
least 3 feet [.91 ml from other electronic appliances and devices that may
interfere with the wireless communication [such as TV’s, microwaves,
computers, etc].
NOTE: I t may take up to 20 minutes for the main unit to re-synchronize
with the sensor when batteries are replaced. Use lithium batteries in the
sensor when the temperature is below -4°F [-20°C].
No Wireless Sensor Data [no communication] no bars and flashing — ” data| If
wireless reception is bad [no bars]. see the “Bad Reception” section above.
The wireless ID setting on each unit must match for all units to communicate
properly. See ··set Wireless ID” on the next page.
Main Unit Display Not Working| Make certain that the batteries are installed
correctly.
The batteries may need replacing.
Please DO NOT return the product to the retail store.
For technical assistance and product return information, please call
Customer Care: 877-221-1252 Mon. – Fri.
8:00 A.M. to 4:45 P.M. (CST)
www.chaneyinstrument.com
Imported by:
Costco Wholesale Corporation
P.O. Box 34535
Seattle, WA 98124-1535
The U.S.A.
1-800- 77 4-2678
Shop at www.costco.com
Set Wireless ID
This wireless thermometer uses a long-range 433mhz radio frequency for
communication.
In the event that you have reception problems due to interference, both the
main unit and the wireless sensor have a selectable wireless ID. The ID
switches are located within the battery compartments of the main unit and the
wireless sensor.
You may choose A.B or C; but both the main unit and the wireless sensor ID’s
must match for successful synchronization.
SECTION 5 • PRODUCT SPECIFICATIONS
Measurement Ranges
Temperature
Main Unit: 32°F to 122°F / o0c to 50°C
Wireless Sensor: -40°F to 158°F / -40°C to 70°C
Specifications
Power Requirements
Main Unit: 3 x “AA’ alkaline or lithium batteries
Wireless Sensor: 2 x “AA” alkaline or lithium batteries
Wireless Communication 433 MHz Radio Frequency-Transmission every 16seconds
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior
to battery installation. Remove batteries from equipment that is not to be
used for an extended period of time. Follow the polarity(+/-) diagram in the
battery compartment. Promptly remove dead batteries from the device. Dispose
of used batteries properly. Only batteries of the same or equivalent type as
recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose
of batteries in fire, as batteries may explode or leak. DO NOT mix old and new
batteries or types of batteries (alkaline/standard). DO NOT use rechargeable
batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit
the supply terminals.
To receive product information, register your product online. It’s quick and
easy
Log on to http://www.chaneyinstrument.com/product_reg.htm
LIMITED ONE YEAR WARRANTY
Chaney Instrument Company warrants that all products it manufactures to be of
good material and workmanship and to be free of defects if properly installed
and operated for a period of one year from the date of purchase. REMEDY FOR
BREACH OF THIS WARRANTY IS EXPRESSLY LIMITED TO REPAIR OR REPLACEMENT OF
DEFECTIVE ITEMS. Any product which, under normal use and service, is proven to
breach the warranty contained herein within ONE YEAR from date of sale will,
upon examination by Chaney, and at its sole option, be repaired or replaced by
Chaney. In all cases, transportation costs and charges for returned goods
shall be paid for by the purchaser. Chaney hereby disclaims all responsibility
for such transportation costs and charges. This warranty will not be breached,
and Chaney will give no credit for products it manufactures which shall have
received normal wear and tear, been damaged, tampered with, abused, improperly
installed, damaged in shipping, or repaired or altered by others than
authorized representatives of Chaney.
THE ABOVE-DESCRIBED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED,
INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE
IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. CHANEY EXPRESSLY
DISCLAIMS ALL LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES,
WHETHER ARISING IN TORT OR BY CONTRACT FROM ANY BREACH OF THIS WARRANTY. SOME
STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO
YOU. CHANEY FURTHER DISCLAIMS ALL LIABILITY FROM PERSONAL INJURY RELATING TO
ITS PRODUCTS TO THE EXTENT PERMITTED BY LAW. BY ACCEPTANCE OF ANY OF CHANEY’S
EQUIPMENT OR PRODUCTS, THE PURCHASER ASSUMES ALL LIABILITY FOR THE
CONSEQUENCES ARISING FROM THEIR USE OR MISUSE. NO PERSON, FIRM OR CORPORATION
IS AUTHORIZED TO ASSUME FOR CHANEY ANY OTHER LIABILITY IN CONNECTION WITH THE
SALE OF ITS PRODUCTS. FURTHERMORE, NO PERSON, FIRM OR CORPORATION IS
AUTHORIZED TO MODIFY OR WAIVE THE TERMS OF THIS PARAGRAPH, AND THE PRECEDING
PARAGRAPH, UNLESS DONE IN WRITING AND SIGNED BY A DULY AUTHORIZED AGENT OF
CHANEY. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE
OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
For in-warranty repair, please contact:
Customer Care Department
Chaney Instrument Company
965 Wells Street
Lake Geneva, WI 53147
Chaney Customer Care
877-221-1252
Mon-Fri 8:00 a.m. to 4:45 p.m. CST
www.chaneyinstrument.com
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions:
1- This device may NOT cause harmful interference, and
2- This device must accept any interference received, including interference
that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
Patent numbers: 5,978,738; 6,076,044; 6,597,990
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>